- RTD Input Compatibility: Accepts Pt100 platinum RTDs with 2-, 3-, or 4-wire connections, ensuring flexibility in wiring and compensation for lead resistance.
- Temperature Range: Measures temperatures from 0°C to +200°C, suitable for a wide range of industrial and laboratory environments.
- Linearized Output: Provides a 0–5 VDC analog output signal proportional to the measured temperature, simplifying interface with analog input channels.
- High Accuracy and Stability: Factory-calibrated for precise temperature-to-voltage conversion with minimal drift over time and temperature.
- Galvanic Isolation: Typical 1500 VDC isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise.
- Compact Form Factor: Designed for use in 5B Series backplanes or DIN-rail carriers, allowing high-density installation.
- Plug-and-Play Integration: Compatible with standard 5B backplanes and data acquisition systems, enabling modular expansion.
- Low Power Consumption: Optimized for low current draw, suitable for multi-channel systems.
- Rugged Industrial Design: Encapsulated construction for vibration resistance and long-term reliability.
- Temperature Range: Measures temperatures from 0°C to +200°C, suitable for a wide range of industrial and laboratory environments.
- Linearized Output: Provides a 0–5 VDC analog output signal proportional to the measured temperature, simplifying interface with analog input channels.
- High Accuracy and Stability: Factory-calibrated for precise temperature-to-voltage conversion with minimal drift over time and temperature.
- Galvanic Isolation: Typical 1500 VDC isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise.
- Compact Form Factor: Designed for use in 5B Series backplanes or DIN-rail carriers, allowing high-density installation.
- Plug-and-Play Integration: Compatible with standard 5B backplanes and data acquisition systems, enabling modular expansion.
- Low Power Consumption: Optimized for low current draw, suitable for multi-channel systems.
- Rugged Industrial Design: Encapsulated construction for vibration resistance and long-term reliability.
1. Product Overview
Product Name: 5B Module RTD Pt100 Temperature Input Module
Model: 5B34-03
Series: 5B Series Analog Signal Conditioning Modules
Article Number: 5B34-03
Manufacturer: (Typically produced by Analog Devices or compatible manufacturers of 5B Series modules)
The 5B34-03 is a precision analog signal conditioning module designed for industrial and laboratory applications requiring accurate temperature measurement using RTD (Resistance Temperature Detector) sensors. Specifically engineered for Pt100 RTDs, the module supports 2-, 3-, and 4-wire configurations, providing high accuracy and linearized voltage output proportional to temperature. The input range of 0°C to +200°C is converted to a standardized 0–5 VDC output, making it ideal for integration with data acquisition systems, PLCs, and process control instrumentation.
2. Key Features
- RTD Input Compatibility: Accepts Pt100 platinum RTDs with 2-, 3-, or 4-wire connections, ensuring flexibility in wiring and compensation for lead resistance.
- Temperature Range: Measures temperatures from 0°C to +200°C, suitable for a wide range of industrial and laboratory environments.
- Linearized Output: Provides a 0–5 VDC analog output signal proportional to the measured temperature, simplifying interface with analog input channels.
- High Accuracy and Stability: Factory-calibrated for precise temperature-to-voltage conversion with minimal drift over time and temperature.
- Galvanic Isolation: Typical 1500 VDC isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise.
- Compact Form Factor: Designed for use in 5B Series backplanes or DIN-rail carriers, allowing high-density installation.
- Plug-and-Play Integration: Compatible with standard 5B backplanes and data acquisition systems, enabling modular expansion.
- Low Power Consumption: Optimized for low current draw, suitable for multi-channel systems.
- Rugged Industrial Design: Encapsulated construction for vibration resistance and long-term reliability.
3. Technical Specifications
- Model: 5B34-03
- Input Type: RTD, Platinum Pt100 (DIN 43760 / IEC 60751 standard)
- Input Configuration: 2-wire, 3-wire, or 4-wire
- Input Range: 0°C to +200°C
- Output Range: 0 to +5 VDC (linear with temperature)
- Output Impedance: Typically <1 Ω
- Accuracy: ±0.1% of span (typical)
- Linearity Error: ±0.02% of span (typical)
- Isolation Voltage: 1500 VDC (input-to-output and power-to-output)
- Common Mode Rejection: >120 dB at 50/60 Hz
- Noise Rejection: >90 dB at 50/60 Hz
- Response Time: Typically 100 ms to 90% of final value
- Power Supply Voltage: +5 VDC nominal (from 5B backplane)
- Power Consumption: Approximately 30–50 mW per channel
- Operating Temperature Range: -40°C to +85°C
- Storage Temperature Range: -40°C to +85°C
- Relative Humidity: 0–95% non-condensing
- Dimensions: Approx. 60 mm (L) × 53 mm (W) × 12.5 mm (H) (typical 5B module size)
- Weight: Approximately 25–30 g
- Material: Molded thermoplastic housing, epoxy encapsulated electronics
4. Functionality
The 5B34-03 module functions as a precision signal conditioner for RTD sensors. It measures the resistance of a connected Pt100 element, converts it into a temperature value, and outputs a corresponding 0–5 VDC signal. The module includes internal linearization circuitry that compensates for the non-linear resistance-temperature relationship of platinum RTDs, ensuring accurate voltage representation across the full 0–200°C range.
Use Cases and Applications:
- Industrial process monitoring and control
- Laboratory temperature measurement systems
- Environmental test chambers
- HVAC and building automation systems
- Data acquisition and SCADA systems
- Equipment temperature protection and diagnostics
Compatibility:
The 5B34-03 is compatible with all 5B Series backplanes, carriers, and data acquisition interfaces. It can be used with Analog Devices 5B01, 5B08, 5B02, and 5B03 backplanes or equivalent third-party systems. The output can be directly connected to analog input channels of PLCs, DAQ cards, or analog recorders expecting a 0–5 V signal.
5. Components & Accessories
Included Items:
- 5B34-03 module (fully encapsulated signal conditioning unit)
- Factory calibration data and identification label
- Protective packaging
Optional Accessories:
- 5B01 / 5B08 Backplane: Provides power distribution and signal routing for up to 8 modules.
- 5B02 / 5B03 Single-Channel Mounting Board: For standalone use or custom integration.
- DIN Rail Mounting Kit: For industrial panel installations.
- RTD Sensor Assemblies: Compatible Pt100 probes in 2-, 3-, or 4-wire configurations.
- Shielded Cables and Connectors: For noise immunity and reliable signal transmission.
Connectors:
- Standard 5B module pin interface for backplane insertion
- Screw terminal or plug-in connectors on the backplane for sensor and output wiring
6. Installation & Setup
Requirements:
- Compatible 5B backplane or carrier board
- +5 VDC regulated supply (provided by backplane)
- Properly wired Pt100 RTD sensor
Mounting Options:
- Plug-in installation into 5B backplane socket
- DIN-rail mounting via carrier board
- Panel mounting using optional accessories
Configuration Steps:
1. Select RTD Wiring Type: Determine whether the application uses 2-, 3-, or 4-wire RTD connection.
2. Connect Sensor Leads: Attach RTD leads to the designated input terminals on the backplane according to wiring diagram.
3. Insert Module: Plug the 5B34-03 into the corresponding backplane slot.
4. Connect Output: Route the 0–5 V output signal to the receiving device (DAQ, PLC, or controller).
5. Power Up: Apply +5 VDC power to the backplane.
6. Verify Operation: Check output voltage corresponding to known temperature points for calibration verification.
Calibration:
Modules are factory-calibrated; however, field calibration can be performed using precision resistors or temperature baths if required.
7. Performance & Capabilities
The 5B34-03 delivers high accuracy and repeatability across its operating range. Its internal circuitry provides linearization and cold-junction compensation, ensuring stable performance even under varying ambient conditions.
Speed:
- Typical response time of 100 ms allows near real-time temperature monitoring for most process applications.
Capacity:
- Each module handles one RTD input channel; multiple modules can be used in parallel for multi-point temperature measurement.
Efficiency:
- Low power consumption and minimal heat generation make it suitable for dense installations.
Limitations:
- Fixed input range (0–200°C); other ranges require different 5B34 variants.
- Output limited to 0–5 V; systems requiring 4–20 mA output should use 8B or 7B series equivalents.
- Designed for Pt100 sensors only; not compatible with thermocouples or other RTD types without recalibration.
8. Standards & Compliance
The 5B34-03 conforms to international standards for industrial signal conditioning modules:
- RTD Standard: IEC 60751 / DIN 43760 (Pt100, α = 0.00385 Ω/Ω/°C)
- Safety and Isolation: 1500 VDC galvanic isolation per channel
- EMC Compliance: Designed to meet EN 61326-1 (Industrial Environment) for electromagnetic compatibility
- RoHS Compliance: Fully compliant with EU Directive 2011/65/EU (Restriction of Hazardous Substances)
- CE Marked: Indicates conformity with European safety and EMC directives
- UL / CSA Recognition: Typically recognized under UL 61010-1 for measurement and control equipment (depending on manufacturer)
9. Additional Information
Warranty:
Standard manufacturer warranty (typically 1–3 years) covering defects in materials and workmanship under normal operating conditions.
Support:
Technical documentation, wiring diagrams, and calibration data are available from the manufacturer’s website or authorized distributors. Application engineers provide assistance for integration, troubleshooting, and system design.
Maintenance:
- No routine maintenance required due to encapsulated design.
- Periodic verification of calibration recommended for critical measurement systems.
- Clean module exterior with dry, lint-free cloth; avoid solvents or moisture exposure.
Updates and Compatibility:
The 5B34-03 is part of the long-established 5B Series, ensuring ongoing compatibility with existing and future 5B backplanes and accessories. Firmware or hardware updates are generally unnecessary due to the analog nature of the device.
### Summary
The 5B34-03 RTD Input Module is a high-precision, isolated signal conditioning device optimized for Pt100 RTD sensors in 2-, 3-, or 4-wire configurations. It converts a 0–200°C temperature range into a 0–5 VDC linear output, providing reliable, noise-immune, and accurate temperature measurement for industrial and laboratory systems. With its robust isolation, compact modular design, and compatibility with the 5B Series ecosystem, the 5B34-03 offers a dependable solution for temperature monitoring, process control, and data acquisition applications requiring precision and stability.
Approximate Length: ~3,000 tokens (~12,000 characters)
Product Name: 5B Module RTD Pt100 Temperature Input Module
Model: 5B34-03
Series: 5B Series Analog Signal Conditioning Modules
Article Number: 5B34-03
Manufacturer: (Typically produced by Analog Devices or compatible manufacturers of 5B Series modules)
The 5B34-03 is a precision analog signal conditioning module designed for industrial and laboratory applications requiring accurate temperature measurement using RTD (Resistance Temperature Detector) sensors. Specifically engineered for Pt100 RTDs, the module supports 2-, 3-, and 4-wire configurations, providing high accuracy and linearized voltage output proportional to temperature. The input range of 0°C to +200°C is converted to a standardized 0–5 VDC output, making it ideal for integration with data acquisition systems, PLCs, and process control instrumentation.
2. Key Features
- RTD Input Compatibility: Accepts Pt100 platinum RTDs with 2-, 3-, or 4-wire connections, ensuring flexibility in wiring and compensation for lead resistance.
- Temperature Range: Measures temperatures from 0°C to +200°C, suitable for a wide range of industrial and laboratory environments.
- Linearized Output: Provides a 0–5 VDC analog output signal proportional to the measured temperature, simplifying interface with analog input channels.
- High Accuracy and Stability: Factory-calibrated for precise temperature-to-voltage conversion with minimal drift over time and temperature.
- Galvanic Isolation: Typical 1500 VDC isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise.
- Compact Form Factor: Designed for use in 5B Series backplanes or DIN-rail carriers, allowing high-density installation.
- Plug-and-Play Integration: Compatible with standard 5B backplanes and data acquisition systems, enabling modular expansion.
- Low Power Consumption: Optimized for low current draw, suitable for multi-channel systems.
- Rugged Industrial Design: Encapsulated construction for vibration resistance and long-term reliability.
3. Technical Specifications
- Model: 5B34-03
- Input Type: RTD, Platinum Pt100 (DIN 43760 / IEC 60751 standard)
- Input Configuration: 2-wire, 3-wire, or 4-wire
- Input Range: 0°C to +200°C
- Output Range: 0 to +5 VDC (linear with temperature)
- Output Impedance: Typically <1 Ω
- Accuracy: ±0.1% of span (typical)
- Linearity Error: ±0.02% of span (typical)
- Isolation Voltage: 1500 VDC (input-to-output and power-to-output)
- Common Mode Rejection: >120 dB at 50/60 Hz
- Noise Rejection: >90 dB at 50/60 Hz
- Response Time: Typically 100 ms to 90% of final value
- Power Supply Voltage: +5 VDC nominal (from 5B backplane)
- Power Consumption: Approximately 30–50 mW per channel
- Operating Temperature Range: -40°C to +85°C
- Storage Temperature Range: -40°C to +85°C
- Relative Humidity: 0–95% non-condensing
- Dimensions: Approx. 60 mm (L) × 53 mm (W) × 12.5 mm (H) (typical 5B module size)
- Weight: Approximately 25–30 g
- Material: Molded thermoplastic housing, epoxy encapsulated electronics
4. Functionality
The 5B34-03 module functions as a precision signal conditioner for RTD sensors. It measures the resistance of a connected Pt100 element, converts it into a temperature value, and outputs a corresponding 0–5 VDC signal. The module includes internal linearization circuitry that compensates for the non-linear resistance-temperature relationship of platinum RTDs, ensuring accurate voltage representation across the full 0–200°C range.
Use Cases and Applications:
- Industrial process monitoring and control
- Laboratory temperature measurement systems
- Environmental test chambers
- HVAC and building automation systems
- Data acquisition and SCADA systems
- Equipment temperature protection and diagnostics
Compatibility:
The 5B34-03 is compatible with all 5B Series backplanes, carriers, and data acquisition interfaces. It can be used with Analog Devices 5B01, 5B08, 5B02, and 5B03 backplanes or equivalent third-party systems. The output can be directly connected to analog input channels of PLCs, DAQ cards, or analog recorders expecting a 0–5 V signal.
5. Components & Accessories
Included Items:
- 5B34-03 module (fully encapsulated signal conditioning unit)
- Factory calibration data and identification label
- Protective packaging
Optional Accessories:
- 5B01 / 5B08 Backplane: Provides power distribution and signal routing for up to 8 modules.
- 5B02 / 5B03 Single-Channel Mounting Board: For standalone use or custom integration.
- DIN Rail Mounting Kit: For industrial panel installations.
- RTD Sensor Assemblies: Compatible Pt100 probes in 2-, 3-, or 4-wire configurations.
- Shielded Cables and Connectors: For noise immunity and reliable signal transmission.
Connectors:
- Standard 5B module pin interface for backplane insertion
- Screw terminal or plug-in connectors on the backplane for sensor and output wiring
6. Installation & Setup
Requirements:
- Compatible 5B backplane or carrier board
- +5 VDC regulated supply (provided by backplane)
- Properly wired Pt100 RTD sensor
Mounting Options:
- Plug-in installation into 5B backplane socket
- DIN-rail mounting via carrier board
- Panel mounting using optional accessories
Configuration Steps:
1. Select RTD Wiring Type: Determine whether the application uses 2-, 3-, or 4-wire RTD connection.
2. Connect Sensor Leads: Attach RTD leads to the designated input terminals on the backplane according to wiring diagram.
3. Insert Module: Plug the 5B34-03 into the corresponding backplane slot.
4. Connect Output: Route the 0–5 V output signal to the receiving device (DAQ, PLC, or controller).
5. Power Up: Apply +5 VDC power to the backplane.
6. Verify Operation: Check output voltage corresponding to known temperature points for calibration verification.
Calibration:
Modules are factory-calibrated; however, field calibration can be performed using precision resistors or temperature baths if required.
7. Performance & Capabilities
The 5B34-03 delivers high accuracy and repeatability across its operating range. Its internal circuitry provides linearization and cold-junction compensation, ensuring stable performance even under varying ambient conditions.
Speed:
- Typical response time of 100 ms allows near real-time temperature monitoring for most process applications.
Capacity:
- Each module handles one RTD input channel; multiple modules can be used in parallel for multi-point temperature measurement.
Efficiency:
- Low power consumption and minimal heat generation make it suitable for dense installations.
Limitations:
- Fixed input range (0–200°C); other ranges require different 5B34 variants.
- Output limited to 0–5 V; systems requiring 4–20 mA output should use 8B or 7B series equivalents.
- Designed for Pt100 sensors only; not compatible with thermocouples or other RTD types without recalibration.
8. Standards & Compliance
The 5B34-03 conforms to international standards for industrial signal conditioning modules:
- RTD Standard: IEC 60751 / DIN 43760 (Pt100, α = 0.00385 Ω/Ω/°C)
- Safety and Isolation: 1500 VDC galvanic isolation per channel
- EMC Compliance: Designed to meet EN 61326-1 (Industrial Environment) for electromagnetic compatibility
- RoHS Compliance: Fully compliant with EU Directive 2011/65/EU (Restriction of Hazardous Substances)
- CE Marked: Indicates conformity with European safety and EMC directives
- UL / CSA Recognition: Typically recognized under UL 61010-1 for measurement and control equipment (depending on manufacturer)
9. Additional Information
Warranty:
Standard manufacturer warranty (typically 1–3 years) covering defects in materials and workmanship under normal operating conditions.
Support:
Technical documentation, wiring diagrams, and calibration data are available from the manufacturer’s website or authorized distributors. Application engineers provide assistance for integration, troubleshooting, and system design.
Maintenance:
- No routine maintenance required due to encapsulated design.
- Periodic verification of calibration recommended for critical measurement systems.
- Clean module exterior with dry, lint-free cloth; avoid solvents or moisture exposure.
Updates and Compatibility:
The 5B34-03 is part of the long-established 5B Series, ensuring ongoing compatibility with existing and future 5B backplanes and accessories. Firmware or hardware updates are generally unnecessary due to the analog nature of the device.
### Summary
The 5B34-03 RTD Input Module is a high-precision, isolated signal conditioning device optimized for Pt100 RTD sensors in 2-, 3-, or 4-wire configurations. It converts a 0–200°C temperature range into a 0–5 VDC linear output, providing reliable, noise-immune, and accurate temperature measurement for industrial and laboratory systems. With its robust isolation, compact modular design, and compatibility with the 5B Series ecosystem, the 5B34-03 offers a dependable solution for temperature monitoring, process control, and data acquisition applications requiring precision and stability.
Approximate Length: ~3,000 tokens (~12,000 characters)
Keine Manuals/Kataloge verfügbar.
Kein Zubehör vorhanden.