SUCHEN SIE DIE PASSENDE

INDUSTRIELLE LÖSUNG?

Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.

5B47-E08

5B module Thermoelement E, 0°..+1000°C in, 0-5V out
  • Hersteller nicht angegeben
  • Kategorie: Signalkonditionierung 5B Module
  • The 5B47-E08 is a precision thermocouple input module designed for industrial and laboratory data acquisition systems. It belongs to the 5B Series of signal conditioning modules, which are widely used for isolating, amplifying, and converting sensor signals into standardized analog outputs. Specifically, the 5B47-E08 is optimized for Type E thermocouples, providing a linearized temperature input range of 0°C to +1000°C and a corresponding voltage output of 0 to +5 V.
- Thermocouple Type: Type E (Chromel-Constantan)
- Input Range: 0°C to +1000°C
- Output Range: 0 to +5 V DC (linearized)
- Linearization: Internal cold-junction compensation and linearization for Type E thermocouples
- High Accuracy: Factory-calibrated for precise temperature-to-voltage conversion
- Electrical Isolation: 1500 V RMS isolation between input, output, and power
- Low Noise: Designed for low drift and high signal integrity in noisy industrial environments
- Compact Form Factor: Standard 5B module size for plug-in installation
- Plug-and-Play Compatibility: Fits standard 5B backplanes and carriers
- Wide Operating Temperature Range: Suitable for industrial temperature conditions
- Rugged Construction: Encapsulated design for protection against vibration, humidity, and contaminants
- Ease of Integration: Standardized pinout and output scaling for direct connection to analog input channels of data acquisition systems
1. Product Overview
Name: 5B47-E08 Thermocouple Input Module
Model: 5B47-E08
Series: 5B Series Analog Signal Conditioning Modules
Article Number: 5B47-E08
Manufacturer: (Typically produced by Analog Devices or compatible 5B module manufacturers; part of the 5B signal conditioning family)

The 5B47-E08 is a precision thermocouple input module designed for industrial and laboratory data acquisition systems. It belongs to the 5B Series of signal conditioning modules, which are widely used for isolating, amplifying, and converting sensor signals into standardized analog outputs. Specifically, the 5B47-E08 is optimized for Type E thermocouples, providing a linearized temperature input range of 0°C to +1000°C and a corresponding voltage output of 0 to +5 V. The module is engineered for high accuracy, electrical isolation, and ease of integration into modular backplanes or DIN-rail-mounted carriers.




2. Key Features
- Thermocouple Type: Type E (Chromel-Constantan)
- Input Range: 0°C to +1000°C
- Output Range: 0 to +5 V DC (linearized)
- Linearization: Internal cold-junction compensation and linearization for Type E thermocouples
- High Accuracy: Factory-calibrated for precise temperature-to-voltage conversion
- Electrical Isolation: 1500 V RMS isolation between input, output, and power
- Low Noise: Designed for low drift and high signal integrity in noisy industrial environments
- Compact Form Factor: Standard 5B module size for plug-in installation
- Plug-and-Play Compatibility: Fits standard 5B backplanes and carriers
- Wide Operating Temperature Range: Suitable for industrial temperature conditions
- Rugged Construction: Encapsulated design for protection against vibration, humidity, and contaminants
- Ease of Integration: Standardized pinout and output scaling for direct connection to analog input channels of data acquisition systems




3. Technical Specifications

| Parameter | Specification |
|----------------|-------------------|
| Model | 5B47-E08 |
| Input Type | Thermocouple Type E (Chromel-Constantan) |
| Input Range | 0°C to +1000°C |
| Output Range | 0 to +5 V DC |
| Output Type | Single-ended voltage output |
| Accuracy | ±0.1% of full scale (typical, depending on calibration) |
| Linearity Error | ±0.05% of full scale |
| Isolation Voltage | 1500 V RMS (input-to-output and power-to-output) |
| Common Mode Rejection (CMR) | >120 dB at 50/60 Hz |
| Bandwidth | Typically 3 Hz (low-pass filtered for noise reduction) |
| Response Time | <100 ms to 90% of final value |
| Power Supply Voltage | +5 V DC (nominal) |
| Power Consumption | Approximately 25 mA |
| Operating Temperature Range | -40°C to +85°C |
| Storage Temperature Range | -55°C to +100°C |
| Relative Humidity | 0–95% non-condensing |
| Dimensions | Approx. 60 mm (L) × 52 mm (W) × 12.5 mm (H) |
| Weight | ~45 g |
| Mounting | Plug-in module for 5B backplane or DIN rail carrier |
| Material | Molded thermoplastic housing, epoxy encapsulated electronics |
| Connector Type | 10-pin plug compatible with 5B backplane sockets |




4. Functionality
The 5B47-E08 functions as a signal conditioning interface between a Type E thermocouple sensor and a data acquisition or control system. It performs three primary functions:

1. Signal Amplification and Linearization:
The module amplifies the low-level millivolt signal from the thermocouple and converts it into a standardized 0–5 V output. It includes internal linearization circuitry to correct the nonlinear temperature-voltage relationship inherent to thermocouples, ensuring accurate temperature representation across the full 0–1000°C range.

2. Cold-Junction Compensation (CJC):
The module automatically compensates for the reference junction temperature, eliminating the need for external compensation hardware. This ensures accurate temperature readings regardless of ambient temperature variations at the connection point.

3. Electrical Isolation:
The 5B47-E08 provides galvanic isolation between the thermocouple input, the output signal, and the power supply. This isolation protects downstream equipment from ground loops, electrical noise, and high common-mode voltages.

Use Cases and Applications:
- Industrial process monitoring and control
- Laboratory temperature measurement systems
- Data acquisition systems (DAQ)
- Test and measurement instrumentation
- Environmental monitoring and thermal profiling
- Embedded control systems requiring isolated temperature inputs

Compatibility:
The module is compatible with all standard 5B backplanes, carriers, and data acquisition systems that accept 0–5 V analog inputs. It can be used with Analog Devices 5B Series backplanes, National Instruments SC-5B carriers, or equivalent third-party systems.




5. Components & Accessories

Included Items:
- 5B47-E08 thermocouple input module (fully encapsulated)
- Factory calibration and test documentation (if supplied by manufacturer)

Optional Accessories:
- 5B01, 5B02, or 5B08 backplanes for multi-channel installation
- 5B Series DIN rail mounting kits
- Thermocouple extension cables (Type E compatible)
- Terminal blocks and screw connectors for sensor wiring
- Protective covers and labeling kits for channel identification

Connectors:
- 10-pin plug interface for connection to 5B backplane
- Screw terminals or plug-in connectors on the carrier for thermocouple input and output wiring




6. Installation & Setup

Requirements:
- +5 V DC power supply (provided through the backplane)
- Compatible 5B backplane or carrier module
- Type E thermocouple sensor with proper polarity and shielding

Mounting Options:
- Plug directly into a 5B backplane slot
- Mount on a DIN rail using a 5B-compatible carrier
- Ensure adequate ventilation and protection from excessive vibration or moisture

Configuration Steps:
1. Insert the 5B47-E08 module into the designated slot on the backplane.
2. Connect the Type E thermocouple leads to the input terminals, observing correct polarity.
3. Connect the backplane output to the analog input channel of the data acquisition system.
4. Power the system with +5 V DC through the backplane.
5. Verify output scaling (0–5 V corresponds to 0–1000°C).
6. Perform system-level calibration if required by the application.

Safety Considerations:
- Ensure isolation barriers are intact before operation.
- Avoid exposure to high humidity or corrosive environments.
- Follow manufacturer’s ESD handling procedures during installation.




7. Performance & Capabilities

Speed and Response:
The module’s internal filtering provides a balance between noise suppression and response time. With a typical bandwidth of 3 Hz, it is optimized for stable temperature readings rather than high-speed transient capture. The response time of less than 100 ms ensures accurate tracking of gradual temperature changes in industrial processes.

Capacity and Range:
- Input range: 0°C to +1000°C (Type E thermocouple)
- Output range: 0–5 V linearized
- The module can be used in multi-channel configurations, with each channel isolated and independently powered.

Efficiency and Stability:
- High common-mode rejection (>120 dB) ensures reliable operation in electrically noisy environments.
- Low drift and high linearity maintain measurement accuracy over time and temperature variations.
- Internal cold-junction compensation minimizes measurement error due to ambient temperature fluctuations.

Limitations:
- Designed specifically for Type E thermocouples; not suitable for other thermocouple types without recalibration.
- Limited bandwidth makes it unsuitable for high-speed thermal transients.
- Requires a regulated +5 V supply and compatible 5B backplane for operation.




8. Standards & Compliance

The 5B47-E08 module is designed and manufactured in accordance with industry standards for signal conditioning and electrical safety. Typical compliance and certifications include:

- Electrical Isolation: Meets or exceeds 1500 V RMS isolation requirements per IEC/EN 61010-1.
- EMC Compliance: Designed to meet EN 61326-1 for electromagnetic compatibility in industrial environments.
- RoHS Compliance: Constructed using lead-free materials and compliant with EU RoHS Directive 2011/65/EU.
- CE Marking: Conforms to applicable European safety and EMC directives.
- UL Recognition: Many 5B modules are UL recognized components (verify with manufacturer).
- Temperature Calibration Standards: Factory calibration traceable to NIST (National Institute of Standards and Technology).

These certifications ensure the module’s suitability for use in regulated industrial and laboratory environments, providing confidence in measurement accuracy, safety, and long-term reliability.




9. Additional Information

Warranty:
Typically supplied with a 1-year limited warranty covering defects in materials and workmanship under normal operating conditions. Warranty terms may vary by distributor or manufacturer.

Support:
Technical support is available through the manufacturer’s or distributor’s engineering support channels. Documentation includes datasheets, application notes, and calibration procedures.

Maintenance:
The 5B47-E08 is a solid-state, encapsulated device requiring minimal maintenance. Periodic verification of calibration is recommended for critical measurement applications. The module should be kept clean and dry, and connectors should be inspected periodically for corrosion or mechanical wear.

Firmware/Updates:
As an analog hardware module, the 5B47-E08 does not require firmware updates. However, updated calibration data or revised datasheets may be available from the manufacturer.

Service Life and Reliability:
The module is designed for long-term continuous operation in industrial environments. Mean time between failures (MTBF) typically exceeds 100,000 hours under nominal conditions.

Environmental Considerations:
Encapsulated construction provides resistance to dust, humidity, and mechanical shock. The module should be operated within specified temperature and humidity limits for optimal performance.

Integration Notes:
When used in multi-channel systems, ensure proper grounding and shielding of thermocouple leads to minimize noise pickup. The 0–5 V output can be directly interfaced with most analog-to-digital converters (ADCs) or PLC analog input modules.




### Summary

The 5B47-E08 Thermocouple Input Module is a high-performance, isolated signal conditioning device tailored for Type E thermocouples. It converts a 0°C to +1000°C temperature range into a linear 0–5 V output, providing precise, noise-immune, and isolated temperature measurements for industrial and laboratory applications. With built-in cold-junction compensation, linearization, and 1500 V RMS isolation, it ensures reliable operation in demanding environments. The module’s compatibility with the 5B Series ecosystem allows seamless integration into existing data acquisition and control systems, making it a robust and dependable choice for temperature measurement and process monitoring tasks.

Keine Manuals/Kataloge verfügbar.

Kein Zubehör vorhanden.