- Thermocouple Input Type: Type S (Platinum-Rhodium / Platinum)
- Input Range: 0°C to +1800°C
- Output Range: 0 V to +5 V (linearized)
- Linearization: Internal cold-junction compensation and linearization for Type S thermocouple characteristics
- High Accuracy: Factory-calibrated for precise temperature-to-voltage conversion
- Electrical Isolation: 1500 V RMS isolation between input, output, and power to protect against ground loops and electrical noise
- Compact Form Factor: Standard 5B module size for plug-in installation into 5B backplanes or carriers
- Low Drift and High Stability: Designed for long-term accuracy and minimal temperature drift
- Plug-and-Play Compatibility: Fully compatible with 5B Series backplanes, data acquisition systems, and signal conditioning racks
- Rugged Industrial Design: Suitable for harsh environments, with robust construction and reliable performance
- Ease of Integration: Standardized pinout and mechanical interface for quick installation and replacement
Unique selling points include its factory-calibrated linearization for Type S thermocouples, high isolation voltage, and standardized 0–5 V output, making it ideal for integration with analog input channels of PLCs, DAQs, and control systems.
- Input Range: 0°C to +1800°C
- Output Range: 0 V to +5 V (linearized)
- Linearization: Internal cold-junction compensation and linearization for Type S thermocouple characteristics
- High Accuracy: Factory-calibrated for precise temperature-to-voltage conversion
- Electrical Isolation: 1500 V RMS isolation between input, output, and power to protect against ground loops and electrical noise
- Compact Form Factor: Standard 5B module size for plug-in installation into 5B backplanes or carriers
- Low Drift and High Stability: Designed for long-term accuracy and minimal temperature drift
- Plug-and-Play Compatibility: Fully compatible with 5B Series backplanes, data acquisition systems, and signal conditioning racks
- Rugged Industrial Design: Suitable for harsh environments, with robust construction and reliable performance
- Ease of Integration: Standardized pinout and mechanical interface for quick installation and replacement
Unique selling points include its factory-calibrated linearization for Type S thermocouples, high isolation voltage, and standardized 0–5 V output, making it ideal for integration with analog input channels of PLCs, DAQs, and control systems.
1. Product Overview
Name: 5B47-S11
Model: 5B47-S11
Series: 5B Series Analog Signal Conditioning Modules
Article Number: 5B47-S11
Manufacturer: (Typically produced by Analog Devices / Measurement Computing / compatible 5B module manufacturers)
The 5B47-S11 is a precision analog signal conditioning module designed for thermocouple signal input and voltage output conversion. Specifically engineered for Type S thermocouples, it provides a linearized temperature-to-voltage conversion over the range of 0°C to +1800°C, producing a corresponding 0–5 VDC output. The module belongs to the 5B Series, a family of compact, isolated signal conditioning modules widely used in industrial measurement and control systems. It is designed for use in data acquisition, process monitoring, and instrumentation applications where accurate temperature measurement and electrical isolation are critical.
2. Key Features
- Thermocouple Input Type: Type S (Platinum-Rhodium / Platinum)
- Input Range: 0°C to +1800°C
- Output Range: 0 V to +5 V (linearized)
- Linearization: Internal cold-junction compensation and linearization for Type S thermocouple characteristics
- High Accuracy: Factory-calibrated for precise temperature-to-voltage conversion
- Electrical Isolation: 1500 V RMS isolation between input, output, and power to protect against ground loops and electrical noise
- Compact Form Factor: Standard 5B module size for plug-in installation into 5B backplanes or carriers
- Low Drift and High Stability: Designed for long-term accuracy and minimal temperature drift
- Plug-and-Play Compatibility: Fully compatible with 5B Series backplanes, data acquisition systems, and signal conditioning racks
- Rugged Industrial Design: Suitable for harsh environments, with robust construction and reliable performance
- Ease of Integration: Standardized pinout and mechanical interface for quick installation and replacement
Unique selling points include its factory-calibrated linearization for Type S thermocouples, high isolation voltage, and standardized 0–5 V output, making it ideal for integration with analog input channels of PLCs, DAQs, and control systems.
3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| Model | 5B47-S11 |
| Input Type | Thermocouple Type S (Platinum-Rhodium / Platinum) |
| Input Range | 0°C to +1800°C |
| Output Range | 0 V to +5 V DC |
| Output Type | Single-ended voltage output |
| Accuracy | ±0.1% of full scale (typical, depending on manufacturer calibration) |
| Linearity | ±0.05% of full scale |
| Isolation Voltage | 1500 V RMS (input-to-output and input-to-power) |
| Common Mode Rejection | >120 dB at 50/60 Hz |
| Bandwidth | Typically 3 Hz (low-pass filtered for noise reduction) |
| Response Time | 100 ms (typical) |
| Power Supply Voltage | +5 V DC (nominal) |
| Power Consumption | <200 mW |
| Operating Temperature Range | -40°C to +85°C |
| Storage Temperature Range | -40°C to +85°C |
| Relative Humidity | 0–95% non-condensing |
| Dimensions | Approx. 60 mm (L) × 52 mm (W) × 12.5 mm (H) (standard 5B module size) |
| Weight | Approx. 45 g |
| Material | Molded thermoplastic housing, flame-retardant |
| Mounting | Plug-in module for 5B backplane or carrier board |
| Connector Type | 10-pin plug compatible with 5B backplanes |
| Cold Junction Compensation | Internal, automatic |
| Linearization Method | Polynomial approximation for Type S thermocouple curve |
| Output Load Resistance | ≥2 kΩ |
| Noise Rejection | 50/60 Hz filtering, differential input design |
4. Functionality
The 5B47-S11 functions as a signal conditioning interface between a Type S thermocouple sensor and a data acquisition or control system. The module accepts the low-level millivolt signal generated by the thermocouple, applies cold-junction compensation, amplification, and linearization, and outputs a scaled 0–5 V signal proportional to the measured temperature.
Working Principle:
1. The thermocouple generates a voltage proportional to the temperature difference between the measurement junction and the reference junction.
2. The module’s internal circuitry compensates for the reference (cold) junction temperature using an integrated temperature sensor.
3. The signal is amplified and linearized according to the Type S thermocouple’s nonlinear voltage-temperature relationship.
4. The conditioned signal is then output as a 0–5 V linear voltage corresponding to 0°C–1800°C.
Use Cases and Applications:
- Industrial process temperature monitoring
- Furnace and kiln temperature measurement
- Metallurgical and glass manufacturing temperature control
- Laboratory and research instrumentation
- Integration with PLCs, SCADA systems, and DAQ hardware
- High-temperature process validation and quality control
Compatibility:
- Compatible with all standard 5B Series backplanes and mounting racks
- Interfaces directly with analog input channels of data acquisition systems, industrial controllers, and signal monitoring equipment
- Works with Type S thermocouples (Platinum-Rhodium/Platinum)
5. Components & Accessories
Included Items:
- 5B47-S11 signal conditioning module (factory calibrated)
- Integrated cold-junction compensation circuitry
- Protective housing with labeling and calibration data
Optional Accessories:
- 5B01, 5B02, 5B03, or 5B08 backplanes for multi-channel installation
- 5B Series power supply modules (+5 V DC regulated)
- Thermocouple input connectors and terminal blocks
- DIN rail mounting adapters for 5B modules
- Shielded cables for noise reduction in industrial environments
Connectors:
- 10-pin plug interface compatible with 5B backplanes
- Screw terminal or plug-in connectors for thermocouple input (depending on carrier board)
- Output and power connections routed through the backplane
6. Installation & Setup
Requirements:
- +5 V DC regulated power supply
- Compatible 5B backplane or carrier board
- Type S thermocouple sensor with appropriate wiring
Mounting Options:
- Plug-in installation into a 5B backplane slot
- DIN rail or panel mounting via compatible carrier boards
Configuration Steps:
1. Insert the 5B47-S11 module into the designated slot on the 5B backplane.
2. Connect the Type S thermocouple leads to the input terminals (observe polarity).
3. Connect the backplane output to the analog input channel of the data acquisition or control system.
4. Power the backplane with a regulated +5 V DC supply.
5. Verify output scaling (0–5 V corresponds to 0–1800°C).
6. Perform system-level calibration if required by the application.
Environmental Considerations:
- Ensure adequate ventilation and avoid exposure to excessive vibration or moisture.
- Maintain ambient temperature within the specified operating range.
- Use shielded cables for thermocouple connections to minimize noise pickup.
7. Performance & Capabilities
The 5B47-S11 delivers high accuracy and stability for demanding temperature measurement applications. Its factory linearization ensures that the output voltage is directly proportional to the measured temperature, simplifying system integration and eliminating the need for software-based compensation.
Performance Highlights:
- Accuracy: Typically ±0.1% of full scale, ensuring precise temperature readings.
- Noise Immunity: High common-mode rejection and input filtering minimize interference from industrial noise sources.
- Response Time: Approximately 100 ms, suitable for most process control applications.
- Isolation: 1500 V RMS galvanic isolation prevents ground loops and protects connected equipment.
- Temperature Stability: Low drift over the full operating temperature range ensures consistent performance.
- Output Drive Capability: Can drive loads ≥2 kΩ without signal degradation.
Limitations:
- Designed specifically for Type S thermocouples; not suitable for other thermocouple types without recalibration.
- Output limited to 0–5 V range; systems requiring 0–10 V or 4–20 mA outputs require additional signal conditioning.
- Bandwidth limited to a few hertz, optimized for stable temperature signals rather than fast transients.
8. Standards & Compliance
The 5B47-S11 conforms to the design and performance standards typical of industrial signal conditioning modules.
Certifications and Compliance:
- CE Marked (Electromagnetic Compatibility and Low Voltage Directive compliance)
- RoHS Compliant (Restriction of Hazardous Substances)
- EN 61326-1 (EMC requirements for electrical equipment for measurement, control, and laboratory use)
- EN 61010-1 (Safety requirements for electrical equipment for measurement and control)
- ISO 9001 manufacturing quality standards (depending on manufacturer)
Industry Standards:
- Compatible with IEEE and ISA signal conditioning conventions
- Designed for integration with standard 5B Series instrumentation systems
9. Additional Information
Warranty:
Typically supplied with a 1-year limited warranty covering defects in materials and workmanship (may vary by manufacturer or distributor).
Support:
- Technical documentation, datasheets, and calibration certificates available from the manufacturer.
- Application notes and integration guides for 5B Series modules.
- Customer support for configuration, troubleshooting, and replacement.
Maintenance:
- No routine maintenance required; module is factory-calibrated and sealed.
- Periodic verification of calibration recommended for critical measurement applications.
- Clean with dry, lint-free cloth; avoid solvents or moisture ingress.
Updates and Compatibility:
- Fully compatible with existing 5B Series infrastructure.
- Future firmware or calibration updates typically not required due to analog design.
- Replacement modules available for long-term system support.
### Summary
The 5B47-S11 Thermocouple Signal Conditioning Module is a high-precision, isolated analog interface designed for Type S thermocouple inputs over a 0°C to +1800°C range, providing a linearized 0–5 V output. As part of the 5B Series, it offers robust electrical isolation, cold-junction compensation, and factory calibration, ensuring reliable and accurate temperature measurement in industrial and laboratory environments. Its standardized form factor, plug-in installation, and compatibility with 5B backplanes make it an ideal choice for scalable, modular data acquisition and control systems.
With its combination of accuracy, isolation, and ease of integration, the 5B47-S11 is a dependable solution for high-temperature measurement applications in manufacturing, research, and process automation.
Name: 5B47-S11
Model: 5B47-S11
Series: 5B Series Analog Signal Conditioning Modules
Article Number: 5B47-S11
Manufacturer: (Typically produced by Analog Devices / Measurement Computing / compatible 5B module manufacturers)
The 5B47-S11 is a precision analog signal conditioning module designed for thermocouple signal input and voltage output conversion. Specifically engineered for Type S thermocouples, it provides a linearized temperature-to-voltage conversion over the range of 0°C to +1800°C, producing a corresponding 0–5 VDC output. The module belongs to the 5B Series, a family of compact, isolated signal conditioning modules widely used in industrial measurement and control systems. It is designed for use in data acquisition, process monitoring, and instrumentation applications where accurate temperature measurement and electrical isolation are critical.
2. Key Features
- Thermocouple Input Type: Type S (Platinum-Rhodium / Platinum)
- Input Range: 0°C to +1800°C
- Output Range: 0 V to +5 V (linearized)
- Linearization: Internal cold-junction compensation and linearization for Type S thermocouple characteristics
- High Accuracy: Factory-calibrated for precise temperature-to-voltage conversion
- Electrical Isolation: 1500 V RMS isolation between input, output, and power to protect against ground loops and electrical noise
- Compact Form Factor: Standard 5B module size for plug-in installation into 5B backplanes or carriers
- Low Drift and High Stability: Designed for long-term accuracy and minimal temperature drift
- Plug-and-Play Compatibility: Fully compatible with 5B Series backplanes, data acquisition systems, and signal conditioning racks
- Rugged Industrial Design: Suitable for harsh environments, with robust construction and reliable performance
- Ease of Integration: Standardized pinout and mechanical interface for quick installation and replacement
Unique selling points include its factory-calibrated linearization for Type S thermocouples, high isolation voltage, and standardized 0–5 V output, making it ideal for integration with analog input channels of PLCs, DAQs, and control systems.
3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| Model | 5B47-S11 |
| Input Type | Thermocouple Type S (Platinum-Rhodium / Platinum) |
| Input Range | 0°C to +1800°C |
| Output Range | 0 V to +5 V DC |
| Output Type | Single-ended voltage output |
| Accuracy | ±0.1% of full scale (typical, depending on manufacturer calibration) |
| Linearity | ±0.05% of full scale |
| Isolation Voltage | 1500 V RMS (input-to-output and input-to-power) |
| Common Mode Rejection | >120 dB at 50/60 Hz |
| Bandwidth | Typically 3 Hz (low-pass filtered for noise reduction) |
| Response Time | 100 ms (typical) |
| Power Supply Voltage | +5 V DC (nominal) |
| Power Consumption | <200 mW |
| Operating Temperature Range | -40°C to +85°C |
| Storage Temperature Range | -40°C to +85°C |
| Relative Humidity | 0–95% non-condensing |
| Dimensions | Approx. 60 mm (L) × 52 mm (W) × 12.5 mm (H) (standard 5B module size) |
| Weight | Approx. 45 g |
| Material | Molded thermoplastic housing, flame-retardant |
| Mounting | Plug-in module for 5B backplane or carrier board |
| Connector Type | 10-pin plug compatible with 5B backplanes |
| Cold Junction Compensation | Internal, automatic |
| Linearization Method | Polynomial approximation for Type S thermocouple curve |
| Output Load Resistance | ≥2 kΩ |
| Noise Rejection | 50/60 Hz filtering, differential input design |
4. Functionality
The 5B47-S11 functions as a signal conditioning interface between a Type S thermocouple sensor and a data acquisition or control system. The module accepts the low-level millivolt signal generated by the thermocouple, applies cold-junction compensation, amplification, and linearization, and outputs a scaled 0–5 V signal proportional to the measured temperature.
Working Principle:
1. The thermocouple generates a voltage proportional to the temperature difference between the measurement junction and the reference junction.
2. The module’s internal circuitry compensates for the reference (cold) junction temperature using an integrated temperature sensor.
3. The signal is amplified and linearized according to the Type S thermocouple’s nonlinear voltage-temperature relationship.
4. The conditioned signal is then output as a 0–5 V linear voltage corresponding to 0°C–1800°C.
Use Cases and Applications:
- Industrial process temperature monitoring
- Furnace and kiln temperature measurement
- Metallurgical and glass manufacturing temperature control
- Laboratory and research instrumentation
- Integration with PLCs, SCADA systems, and DAQ hardware
- High-temperature process validation and quality control
Compatibility:
- Compatible with all standard 5B Series backplanes and mounting racks
- Interfaces directly with analog input channels of data acquisition systems, industrial controllers, and signal monitoring equipment
- Works with Type S thermocouples (Platinum-Rhodium/Platinum)
5. Components & Accessories
Included Items:
- 5B47-S11 signal conditioning module (factory calibrated)
- Integrated cold-junction compensation circuitry
- Protective housing with labeling and calibration data
Optional Accessories:
- 5B01, 5B02, 5B03, or 5B08 backplanes for multi-channel installation
- 5B Series power supply modules (+5 V DC regulated)
- Thermocouple input connectors and terminal blocks
- DIN rail mounting adapters for 5B modules
- Shielded cables for noise reduction in industrial environments
Connectors:
- 10-pin plug interface compatible with 5B backplanes
- Screw terminal or plug-in connectors for thermocouple input (depending on carrier board)
- Output and power connections routed through the backplane
6. Installation & Setup
Requirements:
- +5 V DC regulated power supply
- Compatible 5B backplane or carrier board
- Type S thermocouple sensor with appropriate wiring
Mounting Options:
- Plug-in installation into a 5B backplane slot
- DIN rail or panel mounting via compatible carrier boards
Configuration Steps:
1. Insert the 5B47-S11 module into the designated slot on the 5B backplane.
2. Connect the Type S thermocouple leads to the input terminals (observe polarity).
3. Connect the backplane output to the analog input channel of the data acquisition or control system.
4. Power the backplane with a regulated +5 V DC supply.
5. Verify output scaling (0–5 V corresponds to 0–1800°C).
6. Perform system-level calibration if required by the application.
Environmental Considerations:
- Ensure adequate ventilation and avoid exposure to excessive vibration or moisture.
- Maintain ambient temperature within the specified operating range.
- Use shielded cables for thermocouple connections to minimize noise pickup.
7. Performance & Capabilities
The 5B47-S11 delivers high accuracy and stability for demanding temperature measurement applications. Its factory linearization ensures that the output voltage is directly proportional to the measured temperature, simplifying system integration and eliminating the need for software-based compensation.
Performance Highlights:
- Accuracy: Typically ±0.1% of full scale, ensuring precise temperature readings.
- Noise Immunity: High common-mode rejection and input filtering minimize interference from industrial noise sources.
- Response Time: Approximately 100 ms, suitable for most process control applications.
- Isolation: 1500 V RMS galvanic isolation prevents ground loops and protects connected equipment.
- Temperature Stability: Low drift over the full operating temperature range ensures consistent performance.
- Output Drive Capability: Can drive loads ≥2 kΩ without signal degradation.
Limitations:
- Designed specifically for Type S thermocouples; not suitable for other thermocouple types without recalibration.
- Output limited to 0–5 V range; systems requiring 0–10 V or 4–20 mA outputs require additional signal conditioning.
- Bandwidth limited to a few hertz, optimized for stable temperature signals rather than fast transients.
8. Standards & Compliance
The 5B47-S11 conforms to the design and performance standards typical of industrial signal conditioning modules.
Certifications and Compliance:
- CE Marked (Electromagnetic Compatibility and Low Voltage Directive compliance)
- RoHS Compliant (Restriction of Hazardous Substances)
- EN 61326-1 (EMC requirements for electrical equipment for measurement, control, and laboratory use)
- EN 61010-1 (Safety requirements for electrical equipment for measurement and control)
- ISO 9001 manufacturing quality standards (depending on manufacturer)
Industry Standards:
- Compatible with IEEE and ISA signal conditioning conventions
- Designed for integration with standard 5B Series instrumentation systems
9. Additional Information
Warranty:
Typically supplied with a 1-year limited warranty covering defects in materials and workmanship (may vary by manufacturer or distributor).
Support:
- Technical documentation, datasheets, and calibration certificates available from the manufacturer.
- Application notes and integration guides for 5B Series modules.
- Customer support for configuration, troubleshooting, and replacement.
Maintenance:
- No routine maintenance required; module is factory-calibrated and sealed.
- Periodic verification of calibration recommended for critical measurement applications.
- Clean with dry, lint-free cloth; avoid solvents or moisture ingress.
Updates and Compatibility:
- Fully compatible with existing 5B Series infrastructure.
- Future firmware or calibration updates typically not required due to analog design.
- Replacement modules available for long-term system support.
### Summary
The 5B47-S11 Thermocouple Signal Conditioning Module is a high-precision, isolated analog interface designed for Type S thermocouple inputs over a 0°C to +1800°C range, providing a linearized 0–5 V output. As part of the 5B Series, it offers robust electrical isolation, cold-junction compensation, and factory calibration, ensuring reliable and accurate temperature measurement in industrial and laboratory environments. Its standardized form factor, plug-in installation, and compatibility with 5B backplanes make it an ideal choice for scalable, modular data acquisition and control systems.
With its combination of accuracy, isolation, and ease of integration, the 5B47-S11 is a dependable solution for high-temperature measurement applications in manufacturing, research, and process automation.
Keine Manuals/Kataloge verfügbar.
Kein Zubehör vorhanden.