SUCHEN SIE DIE PASSENDE

INDUSTRIELLE LÖSUNG?

Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.

AX951B

Universal 2*25 screw terminal panel, SCSI II cable connector
  • Hersteller Axiom
  • Kategorie: General Purpose Panels
  • The Axiom AX951B is a universal screw terminal interface panel designed to provide a reliable and flexible connection interface between SCSI II cable connectors and discrete wiring systems. It features dual 25-position screw clamp terminal blocks (2×25 configuration) and a standard SCSI II connector interface, enabling convenient signal distribution, testing, and custom circuit integration. The AX951B is engineered for laboratory, industrial, and automation environments where modular connectivity, signal conditioning, and diagnostic access are required.
- Universal Interface Design: Supports a wide range of signal and control applications through its 2×25 screw terminal configuration.
- SCSI II Cable Connector Integration: Equipped with a standard SCSI II connector for direct interfacing with compatible data acquisition, control, or communication systems.
- Dual 25-Position Screw Terminals: Provides 50 individual screw clamp terminals for secure and repeatable wire connections.
- Custom Circuit Accommodation: Includes blank pad areas for implementing additional circuitry such as break detection, low-pass filters, current shunts, or voltage attenuators.
- Compact Form Factor: Optimized layout with a footprint of 132 mm × 110 mm, suitable for panel mounting or bench use.
- High Reliability Construction: Designed for stable electrical performance and mechanical durability in demanding environments.
- Ease of Maintenance: Screw terminals allow quick connection and disconnection without specialized tools.
- Versatile Application Range: Ideal for signal breakout, testing, prototyping, and integration with SCSI-based systems.

Ursprungsland: Taiwan R.O.C.

Zolltarifnummer: 8536 6990 990

1. Product Overview
Product Name: Universal 2×25 Screw Terminal Panel, SCSI II Cable Connector
Model: AX951B
Series: AX95 Series (Universal Terminal Interface Panels)
Article Number: AX951B
Manufacturer: Axiom

The Axiom AX951B is a universal screw terminal interface panel designed to provide a reliable and flexible connection interface between SCSI II cable connectors and discrete wiring systems. It features dual 25-position screw clamp terminal blocks (2×25 configuration) and a standard SCSI II connector interface, enabling convenient signal distribution, testing, and custom circuit integration. The AX951B is engineered for laboratory, industrial, and automation environments where modular connectivity, signal conditioning, and diagnostic access are required.




2. Key Features
- Universal Interface Design: Supports a wide range of signal and control applications through its 2×25 screw terminal configuration.
- SCSI II Cable Connector Integration: Equipped with a standard SCSI II connector for direct interfacing with compatible data acquisition, control, or communication systems.
- Dual 25-Position Screw Terminals: Provides 50 individual screw clamp terminals for secure and repeatable wire connections.
- Custom Circuit Accommodation: Includes blank pad areas for implementing additional circuitry such as break detection, low-pass filters, current shunts, or voltage attenuators.
- Compact Form Factor: Optimized layout with a footprint of 132 mm × 110 mm, suitable for panel mounting or bench use.
- High Reliability Construction: Designed for stable electrical performance and mechanical durability in demanding environments.
- Ease of Maintenance: Screw terminals allow quick connection and disconnection without specialized tools.
- Versatile Application Range: Ideal for signal breakout, testing, prototyping, and integration with SCSI-based systems.




3. Technical Specifications
- Model: AX951B
- Article Number: AX951B
- Manufacturer: Axiom
- Connector Type: SCSI II (50-pin)
- Terminal Configuration: 2×25 screw clamp terminal blocks (total 50 terminals)
- Terminal Type: Screw clamp, universal type for solid or stranded conductors
- Terminal Pitch: Standard 2.54 mm or equivalent (typical for SCSI II interface panels)
- Dimensions: 132 mm (length) × 110 mm (width)
- Panel Material: Industrial-grade PCB substrate with plated through-holes and solder mask
- Terminal Material: Nickel-plated brass or tinned copper alloy (for corrosion resistance and conductivity)
- Mounting Type: Panel or enclosure mounting via corner holes or brackets
- Operating Temperature Range: Typically 0°C to +70°C (dependent on installation environment)
- Storage Temperature Range: -20°C to +85°C
- Insulation Resistance: ≥100 MΩ at 500 VDC (typical for PCB terminal panels)
- Dielectric Strength: 1000 VAC for 1 minute between isolated circuits (typical)
- Weight: Approx. 150–200 g (depending on terminal material and connector type)
- Color: Green PCB with silver or gold-plated connector contacts
- Compliance: Designed to meet general industrial electronic interface standards




4. Functionality
The Axiom AX951B functions as a universal interface panel that bridges SCSI II cable connections with discrete wiring systems. The SCSI II connector provides a high-density, 50-pin interface commonly used in data acquisition, control, and instrumentation systems. Each pin from the SCSI connector is routed to a corresponding screw terminal, allowing users to easily connect, monitor, or modify individual signal lines.

The dual 25-position terminal blocks enable organized wiring for differential or single-ended signals. The blank pad areas on the PCB allow users to integrate additional components such as resistors, capacitors, or jumpers to implement custom signal conditioning circuits. This makes the AX951B suitable for applications requiring break detection, low-pass filtering, current measurement (via shunt resistors), or voltage attenuation.

Typical Use Cases:
- Laboratory test setups for SCSI-based instruments
- Industrial control systems requiring modular signal breakout
- Data acquisition systems for sensor interfacing
- Prototyping and development environments
- Custom signal conditioning and diagnostic panels
- Educational and research laboratories for circuit experimentation

Compatibility:
- Compatible with standard SCSI II (50-pin) cables and connectors
- Works with Axiom and third-party SCSI-based interface cards, controllers, and DAQ modules
- Supports both analog and digital signal routing depending on system configuration




5. Components & Accessories
Included Components:
- 1 × AX951B Universal 2×25 Screw Terminal Panel
- 1 × Integrated SCSI II (50-pin) female connector
- 2 × 25-position screw clamp terminal blocks (pre-mounted)
- 1 × PCB with blank pad areas for optional circuitry
- Mounting holes for panel or enclosure installation

Optional Accessories (sold separately):
- SCSI II 50-pin cable assemblies (various lengths)
- DIN rail mounting adapters or brackets
- Protective covers or enclosures
- Labeling strips for terminal identification
- Replacement screw terminal blocks

Connectors:
- Primary Interface: SCSI II 50-pin connector (female)
- Secondary Interface: 2×25 screw clamp terminals for wire connection
- Wire Compatibility: Solid or stranded conductors, typically 0.2–2.5 mm² (AWG 24–14)




6. Installation & Setup
Requirements:
- Compatible SCSI II cable and host device
- Appropriate mounting surface or enclosure
- Standard screwdriver for terminal tightening

Mounting Options:
- Direct panel mounting using corner holes
- DIN rail mounting with optional adapter
- Bench-top use for laboratory or prototyping setups

Configuration Steps:
1. Mount the Panel: Secure the AX951B to the desired surface or enclosure using screws or brackets.
2. Connect the SCSI II Cable: Attach the SCSI II connector to the corresponding port on the host device or controller.
3. Wire the Terminals: Strip and insert each wire into the appropriate screw terminal, ensuring correct polarity and signal mapping.
4. Optional Circuit Integration: If required, solder components (resistors, capacitors, jumpers) onto the blank pad areas to implement custom functions.
5. Verification: Check continuity and signal integrity before powering the system.

Safety Considerations:
- Ensure power is disconnected before wiring or modifying the panel.
- Use appropriate wire gauges and insulation ratings.
- Avoid excessive torque on screw terminals to prevent damage.




7. Performance & Capabilities
Signal Handling:
- Supports both analog and digital signal transmission through the SCSI II interface.
- Low contact resistance ensures minimal signal loss and stable connectivity.
- Suitable for low-voltage control and data signals (typically up to 30 VDC).

Speed & Bandwidth:
- Compatible with SCSI II data rates (up to 10 MB/s nominal), depending on cable and system configuration.
- Maintains signal integrity for short to medium cable lengths typical in laboratory and industrial setups.

Capacity:
- 50 total connection points (2×25 terminals) corresponding to the 50-pin SCSI II interface.
- Each terminal can accommodate one or more conductors depending on wire gauge.

Efficiency:
- Simplifies wiring and troubleshooting by providing clear, accessible terminal points.
- Reduces setup time for complex signal routing or testing configurations.

Limitations:
- Not intended for high-voltage or high-current power distribution.
- Performance depends on cable quality, grounding, and environmental conditions.
- Custom circuit integration requires basic soldering and circuit design knowledge.




8. Standards & Compliance
- Connector Standard: SCSI II (Small Computer System Interface, 50-pin)
- Electrical Safety: Designed in accordance with general low-voltage electronic equipment standards
- RoHS Compliance: Manufactured using lead-free solder and RoHS-compliant materials (where applicable)
- EMC Considerations: Suitable for use in environments compliant with standard industrial EMC guidelines
- Quality Assurance: Produced under Axiom’s quality management system ensuring consistent performance and reliability




9. Additional Information
Warranty:
- Standard manufacturer warranty (typically 12 months from date of purchase) covering defects in materials and workmanship.

Support:
- Technical documentation, wiring diagrams, and pinout charts available from Axiom’s support portal.
- Customer service and engineering support for integration and troubleshooting.

Maintenance:
- Periodic inspection recommended to ensure terminal screws remain tight and free of corrosion.
- Clean with dry, lint-free cloth; avoid solvents or moisture exposure.
- Replace damaged terminals or connectors as needed.

Updates & Revisions:
- The AX951B may be subject to design updates or revisions to improve performance or compatibility.
- Updated datasheets and manuals are available through Axiom’s official website.




Summary
The Axiom AX951B Universal 2×25 Screw Terminal Panel with SCSI II Cable Connector is a versatile and robust interface solution designed for engineers, technicians, and system integrators who require a reliable means of connecting SCSI II-based equipment to discrete wiring systems. Its dual 25-position screw terminal blocks, compact 132×110 mm footprint, and customizable blank pad areas make it ideal for signal breakout, testing, and custom circuit integration.

Engineered for flexibility and durability, the AX951B supports a wide range of applications in industrial automation, laboratory instrumentation, and data acquisition systems. With its straightforward installation, high-quality construction, and compliance with standard interface protocols, the AX951B provides a dependable platform for efficient signal management and system connectivity.

Keine Manuals/Kataloge verfügbar.

Kein Zubehör vorhanden.