SUCHEN SIE DIE PASSENDE

INDUSTRIELLE LÖSUNG?

Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.

CI-132

2*RS422/485, 50-921600bps, auto data direction switching
  • Hersteller Moxa
  • Kategorie: RS485 / RS422 2-Ports
  • The Moxa Industio CI‑132 is a 2‑port RS‑422/RS‑485 industrial serial communication board designed for 16‑bit ISA/EISA bus systems. It provides two independent asynchronous serial ports for connecting industrial devices such as data acquisition systems, terminals, modems, barcode readers, and other serial peripherals to PCs. The CI‑132 is part of Moxa’s Industio family of industrial multiport asynchronous solutions, offering high‑speed, reliable, and configurable serial communication for automation and control environments.
- Dual RS‑422/RS‑485 Ports: Two independent serial ports supporting either RS‑422 full‑duplex or RS‑485 half‑duplex communication.
- High‑Speed Data Transmission: Supports baud rates from 50 bps to 921.6 Kbps, with both normal and high‑speed operation modes.
- Automatic Data Direction Control: Hardware‑based automatic data direction switching for RS‑485 eliminates the need for software control, simplifying programming and ensuring precise timing.
- Software‑Configurable Hardware: No physical DIP switches or jumpers for I/O or IRQ configuration; all parameters are stored in on‑board EEPROM and configured via the Io‑irq.exe utility.
- Compact ASIC Design: Custom Moxa ASIC reduces component count, increases reliability, and provides a half‑size ISA form factor (157 × 83 mm).
- Termination Resistors On‑Board: Built‑in 120 Ω termination resistors for impedance matching in RS‑422/485 networks.
- Surge and Isolation Protection (Model‑Dependent):
- CI‑132: Standard version
- CI‑132I: 2 kV optical isolation
- CI‑132IS: 2 kV isolation and 2 kV surge protection
- Flexible Configuration: Independent I/O address, IRQ, and interrupt vector per port.
- Wide OS Support: Drivers available for Windows NT, 95/98, 2000, XP, 2003, DOS, Linux, and compatibility with UNIX/XENIX, QNX, FreeBSD, OS/2.
- Comprehensive Software Tools: Bundled with Moxa PComm (Windows) and API‑232 (DOS) libraries for serial programming, diagnostics, and monitoring.
- Industrial Reliability: Designed for harsh environments with TVSS protection, stable operation, and long‑distance communication up to 4000 ft (1.2 km).

Ursprungsland: Taiwan R.O.C.

Zolltarifnummer: 8473 3020 000

Comprehensive Product Summary – Moxa Industio CI‑132 Series




### 1. Product Overview

Product Name: Industio CI‑132
Model: CI‑132
Series: Industio CI‑132 Series (includes CI‑132, CI‑132I, CI‑132IS)
Article Number: CI‑132
Manufacturer: Moxa Technologies Co., Ltd.
Part Number (P/N): 18020013211

The Moxa Industio CI‑132 is a 2‑port RS‑422/RS‑485 industrial serial communication board designed for 16‑bit ISA/EISA bus systems. It provides two independent asynchronous serial ports for connecting industrial devices such as data acquisition systems, terminals, modems, barcode readers, and other serial peripherals to PCs. The CI‑132 is part of Moxa’s Industio family of industrial multiport asynchronous solutions, offering high‑speed, reliable, and configurable serial communication for automation and control environments.




### 2. Key Features

- Dual RS‑422/RS‑485 Ports: Two independent serial ports supporting either RS‑422 full‑duplex or RS‑485 half‑duplex communication.
- High‑Speed Data Transmission: Supports baud rates from 50 bps to 921.6 Kbps, with both normal and high‑speed operation modes.
- Automatic Data Direction Control: Hardware‑based automatic data direction switching for RS‑485 eliminates the need for software control, simplifying programming and ensuring precise timing.
- Software‑Configurable Hardware: No physical DIP switches or jumpers for I/O or IRQ configuration; all parameters are stored in on‑board EEPROM and configured via the Io‑irq.exe utility.
- Compact ASIC Design: Custom Moxa ASIC reduces component count, increases reliability, and provides a half‑size ISA form factor (157 × 83 mm).
- Termination Resistors On‑Board: Built‑in 120 Ω termination resistors for impedance matching in RS‑422/485 networks.
- Surge and Isolation Protection (Model‑Dependent):
- CI‑132: Standard version
- CI‑132I: 2 kV optical isolation
- CI‑132IS: 2 kV isolation and 2 kV surge protection
- Flexible Configuration: Independent I/O address, IRQ, and interrupt vector per port.
- Wide OS Support: Drivers available for Windows NT, 95/98, 2000, XP, 2003, DOS, Linux, and compatibility with UNIX/XENIX, QNX, FreeBSD, OS/2.
- Comprehensive Software Tools: Bundled with Moxa PComm (Windows) and API‑232 (DOS) libraries for serial programming, diagnostics, and monitoring.
- Industrial Reliability: Designed for harsh environments with TVSS protection, stable operation, and long‑distance communication up to 4000 ft (1.2 km).




### 3. Technical Specifications

| Parameter | Specification |
|----------------|-------------------|
| Bus Interface | 16‑bit ISA (EISA compatible) |
| Number of Ports | 2 independent RS‑422/RS‑485 ports |
| Maximum Boards per System | 4 |
| Communication Controller | TI550C UART |
| Baud Rate Range | 50 bps – 921.6 Kbps |
| Data Bits | 5, 6, 7, 8 |
| Stop Bits | 1, 1.5, 2 |
| Parity | None, Even, Odd, Space, Mark |
| Flow Control | Hardware (RTS/CTS) and Software (XON/XOFF) |
| FIFO Buffer | 16‑byte Tx/Rx FIFO per port |
| I/O Address Range | 0x0000 – 0xFFFF |
| IRQ Options | 2, 3, 4, 5, 7, 10, 11, 12, 15 |
| Interrupt Vector | Configurable (0x0000 – 0xFFFF) |
| Connectors | 2 × DB9 male (DTE) |
| Termination Resistor | 120 Ω (selectable via jumper) |
| Isolation Protection | Up to 2000 V (CI‑132I, CI‑132IS) |
| Surge Protection | Up to 2000 V (CI‑132IS) |
| Power Requirements | +5 V DC: CI‑132 – 240 mA max; CI‑132I – 520 mA max; CI‑132IS – 790 mA max |
| Operating Temperature | 0 °C – 55 °C |
| Dimensions (W × H) | 157 mm × 83 mm |
| Weight | Approx. 120 g |
| Compliance | ISA/EISA bus compatible |
| Operating Systems | Windows NT/95/98/2000/XP/2003, DOS, Linux, SCO UNIX/XENIX, QNX, FreeBSD, OS/2 |




### 4. Functionality

The CI‑132 functions as a dual‑port asynchronous serial communication interface card for PCs. Each port can be configured independently for RS‑422 or RS‑485 operation:

- RS‑422 Mode: Full‑duplex, point‑to‑point or multi‑drop communication up to 10 Mbps over 4000 ft.
- RS‑485 Mode: 2‑wire half‑duplex, multi‑drop communication supporting up to 32 devices per bus.

Automatic Data Direction Control ensures seamless switching between transmit and receive modes in RS‑485 without software intervention. Alternatively, users can select By RTS Mode for backward compatibility with legacy applications.

Use Cases and Applications:
- Industrial and factory automation systems
- Remote serial device control
- Data acquisition and monitoring
- Barcode readers, PLCs, and sensors
- POS systems, scales, and terminals
- SCADA and process control networks

Compatibility:
The CI‑132 is compatible with standard COM port applications and supports Moxa’s PComm and API‑232 libraries for custom software development. It integrates with Windows COMM API and standard serial communication protocols.




### 5. Components & Accessories

Package Contents:
- 1 × CI‑132 2‑port serial board
- Documentation and Software CD (drivers, utilities, manuals)
- Quick Installation Guide

Connectors:
- Two DB9 male connectors on the board.
- RS‑422 Pinout:
1 = TxD‑(A), 2 = TxD+(B), 3 = RxD+(B), 4 = RxD‑(A), 5 = GND, 6 = RTS‑(A), 7 = RTS+(B), 8 = CTS+(B), 9 = CTS‑(A)
- RS‑485 Pinout (2‑wire):
1 = Data‑(A), 2 = Data+(B), 5 = GND

Optional Accessories:
- RS‑422/485 cables and terminal blocks
- External surge protection modules (for CI‑132)
- Moxa PComm Lite software package (included)




### 6. Installation & Setup

Hardware Installation:
1. Power off the PC.
2. Insert the CI‑132 board into an available 16‑bit ISA slot.
3. Secure the board with the mounting screw.
4. Configure jumpers and switches as required:
- JP1 (CAP Jumper): Open = normal; Short = force CAP address 0xA700 (for quick install).
- SW2 (Interface Switch): ON = RS‑485; OFF = RS‑422.
- SW1 (Data Mode Switch): ON = Automatic Data Direction; OFF = By RTS.
- JP3/JP4 (Termination Resistors): Short = enable 120 Ω; Open = disable.
5. Power on the PC and configure I/O, IRQ, and INT vector using Io‑irq.exe under DOS.
6. Save configuration (F10) and reboot.

Quick Installation (Windows NT/95/98):
- Short JP1 to fix CAP = 0xA700.
- Install the driver directly; software configuration automatically updates EEPROM.
- Cold restart after configuration changes.

Software Installation:
- Windows 95/98: Run *Setup95.exe* from CD → Configure ports → Restart.
- Windows NT: Add adapter via Control Panel → Network → Adapters → Have Disk → Select CI‑132 → Configure → Restart.
- Windows 2000/XP/2003: Use *Add/Remove Hardware* wizard → *Have Disk* → Select driver from *Win2K‑XP‑2003* folder.
- Linux: Mount CD, extract *mxser.tgz*, compile and install module (*make install*), create device nodes (*msmknod*), and load driver (*modprobe mxser ioaddr=0x180*).
- DOS: Run *DOSINST.EXE*, configure via *SETUP.EXE*, and load driver *SER‑DRV.EXE*.




### 7. Performance & Capabilities

- Transmission Speed: Up to 921.6 Kbps (high‑speed spectrum).
- Distance: Up to 4000 ft (1.2 km) for RS‑422; typical RS‑485 multi‑drop up to 1200 m.
- FIFO Buffering: 16‑byte transmit/receive FIFO per port ensures no data loss at high speeds.
- Flow Control: Hardware (RTS/CTS) and software (XON/XOFF) supported.
- Interrupt Handling: Independent IRQ and interrupt vector per port; supports interrupt‑driven or polling modes.
- Reliability: ASIC‑based design minimizes latency and CPU load; EEPROM retains configuration.
- Limitations: ISA bus only; maximum of four boards per system; RS‑485 limited to 2‑wire half‑duplex.




### 8. Standards & Compliance

- Electrical Interface Standards:
- RS‑422 (EIA‑422) balanced differential signaling
- RS‑485 (EIA‑485) 2‑wire half‑duplex
- Bus Compatibility: 16‑bit ISA/EISA
- Protection:
- Optical isolation up to 2 kV (CI‑132I/IS)
- Surge suppression up to 2 kV (CI‑132IS)
- Termination: 120 Ω impedance matching resistors on board
- Operating System Compliance:
- Windows NT/95/98/2000/XP/2003
- DOS, Linux, SCO UNIX/XENIX, QNX, FreeBSD, OS/2
- Regulatory Compliance: Designed for industrial environments; conforms to standard PC I/O address mapping and IRQ allocation.
- UART Compliance: TI550C UART with 16550‑compatible register set.




### 9. Additional Information

Warranty & Support:
- Standard Moxa limited warranty (contact regional distributor for terms).
- Technical support via email: support@moxa.com.tw or support@moxa.com.
- Driver and firmware updates available from ftp.moxa.com or www.moxa.com.

Maintenance:
- No periodic maintenance required; ensure proper grounding and environmental conditions.
- Use anti‑static precautions when handling the board.

Software Tools:
- PComm (Windows): Serial communication library and utilities (diagnostic, monitor, terminal emulator).
- API‑232 (DOS): Serial programming library supporting C, Pascal, BASIC, Assembly, and Clipper.
- Utilities:
- *Io‑irq.exe* – hardware configuration utility
- *SER‑DRV.EXE* – DOS driver loader
- *SCOPE.EXE* – data scope and terminal emulator
- *DIAGNOSE.EXE* – hardware diagnostic tool

Troubleshooting Highlights:
- Board not detected: Check slot seating, I/O conflicts, or CAP address (use JP1 = short → CAP = 0xA700).
- No data transfer: Verify cable wiring and flow control settings.
- IRQ conflicts: Adjust BIOS or reassign IRQ via Io‑irq utility.
- Driver errors: Reinstall or update driver; ensure correct OS version.

Return & RMA Procedure:
- Obtain RMA number from dealer or Moxa support.
- Provide purchase proof and completed Problem Report Form.
- Ship product in anti‑static packaging with RMA number clearly marked.




### Summary

The Moxa Industio CI‑132 is a robust, high‑performance dual‑port RS‑422/RS‑485 ISA serial board engineered for industrial communication applications. Its combination of hardware‑based automatic data direction control, software‑configurable parameters, and comprehensive driver support across multiple operating systems makes it a versatile solution for legacy PC‑based control systems and industrial automation networks. With data rates up to 921.6 Kbps, built‑in termination resistors, and optional isolation and surge protection, the CI‑132 ensures reliable, noise‑resistant serial communication in demanding environments.

Kein Zubehör vorhanden.