SUCHEN SIE DIE PASSENDE
INDUSTRIELLE LÖSUNG?
Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.
- Standalone Operation: No PC or external power supply required; powered directly via the RS-232 console port (RTS signal).
- Universal Compatibility: Designed for ORing switches, access points, and routers equipped with DB9 console ports.
- Multiple Connector Options: Available in DB9, RJ45, and M12 (5-pin A-coding) versions for different device interfaces.
- Simple Data Management: DIP switch and push-button interface for intuitive upload/download operations.
- Dual Configuration Storage: Two configuration memory locations (A & B) for flexible backup management.
- LED Status Indicators: Clear visual feedback for power, data transmission, and operation status.
- Compact and Rugged Design: Industrial-grade PC-molded enclosure with IP40 protection rating.
- Environmentally Robust: Wide operating temperature range (-10°C to 60°C) and high humidity tolerance (up to 95% non-condensing).
- Regulatory Compliance: Meets FCC Part 15, CISPR (EN55022) Class A, and EN61000-4 series EMC standards.
- Maintenance-Free Operation: No moving parts or external power adapters required.
- Quick Installation: Plug-and-play design for immediate use in field maintenance or configuration replication tasks.
- Universal Compatibility: Designed for ORing switches, access points, and routers equipped with DB9 console ports.
- Multiple Connector Options: Available in DB9, RJ45, and M12 (5-pin A-coding) versions for different device interfaces.
- Simple Data Management: DIP switch and push-button interface for intuitive upload/download operations.
- Dual Configuration Storage: Two configuration memory locations (A & B) for flexible backup management.
- LED Status Indicators: Clear visual feedback for power, data transmission, and operation status.
- Compact and Rugged Design: Industrial-grade PC-molded enclosure with IP40 protection rating.
- Environmentally Robust: Wide operating temperature range (-10°C to 60°C) and high humidity tolerance (up to 95% non-condensing).
- Regulatory Compliance: Meets FCC Part 15, CISPR (EN55022) Class A, and EN61000-4 series EMC standards.
- Maintenance-Free Operation: No moving parts or external power adapters required.
- Quick Installation: Plug-and-play design for immediate use in field maintenance or configuration replication tasks.
Comprehensive Product Summary – ORing DBU-01-DB9 Configuration Backup Unit
### 1. Product Overview
Product Name: Configuration Backup Unit for DB9 Type Console Port
Model: DBU-01-DB9
Series: DBU-01 Series (also includes DBU-01-RJ45 and DBU-01-M12 variants)
Article Number: DBU-01-DB9
Manufacturer: ORing Industrial Networking Corp.
Version: 1.0
Product Type: Standalone configuration backup and restore device for ORing network equipment
Intended Use: Backup and restoration of configuration data for ORing switches, access points (APs), and access routers (ARs) via DB9 console interface
The ORing DBU-01-DB9 is a compact, industrial-grade configuration backup unit designed to simplify the management of ORing networking devices. It enables users to back up and restore configuration data directly through the console port without the need for a PC or external software. The device is powered directly from the connected ORing device, ensuring portability and ease of use in field or industrial environments.
### 2. Key Features
- Standalone Operation: No PC or external power supply required; powered directly via the RS-232 console port (RTS signal).
- Universal Compatibility: Designed for ORing switches, access points, and routers equipped with DB9 console ports.
- Multiple Connector Options: Available in DB9, RJ45, and M12 (5-pin A-coding) versions for different device interfaces.
- Simple Data Management: DIP switch and push-button interface for intuitive upload/download operations.
- Dual Configuration Storage: Two configuration memory locations (A & B) for flexible backup management.
- LED Status Indicators: Clear visual feedback for power, data transmission, and operation status.
- Compact and Rugged Design: Industrial-grade PC-molded enclosure with IP40 protection rating.
- Environmentally Robust: Wide operating temperature range (-10°C to 60°C) and high humidity tolerance (up to 95% non-condensing).
- Regulatory Compliance: Meets FCC Part 15, CISPR (EN55022) Class A, and EN61000-4 series EMC standards.
- Maintenance-Free Operation: No moving parts or external power adapters required.
- Quick Installation: Plug-and-play design for immediate use in field maintenance or configuration replication tasks.
### 3. Technical Specifications
Physical Characteristics
- Enclosure Material: PC molding (industrial-grade plastic)
- Protection Rating: IP40 (protection against solid objects >1 mm; not waterproof)
- Dimensions (W × D × H): 32 × 14.5 × 90 mm (1.25 × 0.57 × 3.5 in)
- Cable Length: 172 mm
- Weight: 53 g (typical)
- Color: Industrial gray/black (standard ORing finish)
Power
- Input Voltage: 5–12 VDC (supplied via RS-232 RTS signal from connected device)
- Power Source: No external power supply required
Environmental Conditions
- Operating Temperature: -10°C to 60°C (14°F to 140°F)
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Operating Humidity: 5% to 95% RH, non-condensing
Regulatory & EMC Compliance
- EMI: FCC Part 15, CISPR (EN55022) Class A
- EMS: EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
### 4. Functionality
The DBU-01-DB9 serves as a portable configuration management tool for ORing network devices. It allows users to back up configuration data from one device and restore it to another without requiring a computer or network connection.
Operating Principle:
1. The unit connects directly to the console port (DB9 interface) of an ORing device.
2. Once connected, the device draws power through the RS-232 RTS signal.
3. The user selects the desired operation (upload or download) using the DIP switch and initiates the process via the Start button.
4. Configuration data is transferred between the DBU-01 and the connected device.
5. LED indicators provide real-time feedback on power, transmission, and success/failure status.
Use Cases:
- Field maintenance and configuration replication for ORing switches, APs, and routers.
- Rapid deployment of standardized configurations across multiple devices.
- Backup of critical configuration data before firmware upgrades or system changes.
- Restoration of device settings after hardware replacement or reset.
Compatibility:
- Compatible exclusively with ORing Industrial Networking devices equipped with DB9 console ports.
- Other models (DBU-01-RJ45, DBU-01-M12) support devices with RJ45 or M12 console interfaces.
### 5. Components & Accessories
Package Contents:
- 1 × DBU-01-DB9 Configuration Backup Unit
- 1 × Quick Installation Guide (QIG)
Included Components:
- Integrated DB9 connector cable (172 mm length)
- Built-in DIP switch (2-pole) for upload/download selection
- Start button for initiating data transfer
- Dual configuration memory selector (A & B)
- LED indicators for power, transmission, and status
Optional Accessories:
- None required; the unit is self-contained.
- Optional variants (DBU-01-RJ45, DBU-01-M12) available for other connector types.
Connectors:
- Console Interface: DB9 male connector (RS-232 standard)
- Power Input: Supplied via RS-232 RTS signal (no external connector)
### 6. Installation & Setup
Pre-Installation Requirements:
- Ensure the target ORing device (switch, AP, or AR) is powered on.
- Verify that the DBU-01 model matches the console port type (DB9).
- Confirm that the device is compatible with the DBU-01 series (refer to ORing datasheet).
Installation Steps:
1. Connect: Insert the DBU-01-DB9 connector into the console port of the ORing device.
2. Power Check: Confirm that the green Power LED illuminates, indicating the unit is powered.
3. Select Operation: Use the DIP switch to choose between Upload (backup) or Download (restore).
4. Initiate Transfer: Press the Start button to begin the selected operation.
5. Monitor LEDs:
- Amber LED blinking: Data transmission in progress.
- Green LED on: Transmission successful.
- Red LED on: Transmission failed.
6. Switch Configuration Memory: Use the Config Location switch (A/B) to select or change the storage slot for configuration data.
Mounting Options:
- Handheld or temporary connection; no permanent mounting required.
- Compact form factor allows easy use in field environments or control cabinets.
Safety Notes:
- The device is not waterproof; avoid exposure to liquids.
- Operate only within specified temperature and humidity ranges.
- Use only with compatible ORing devices to prevent malfunction.
### 7. Performance & Capabilities
Operational Performance:
- Data Transfer Method: Serial communication via RS-232 console interface.
- Backup/Restore Speed: Dependent on device configuration size and console baud rate (typical RS-232 speeds).
- Configuration Storage: Two independent memory slots (A and B) for storing multiple device configurations.
- Power Efficiency: Consumes minimal power directly from the host device (5–12 VDC).
- Reliability: Solid-state design ensures high durability and long operational life.
Efficiency & Usability:
- Eliminates the need for a computer or software tools during configuration management.
- Reduces downtime during device replacement or configuration replication.
- Provides immediate visual feedback through LED indicators for operational assurance.
Limitations:
- Compatible only with ORing devices; not intended for third-party equipment.
- Not suitable for outdoor or high-moisture environments (IP40 rating).
- Limited to console-based configuration data (does not back up firmware or user data).
### 8. Standards & Compliance
Electromagnetic Compatibility (EMC):
- EMI Compliance:
- FCC Part 15 Class A
- CISPR (EN55022) Class A
- EMS Compliance:
- EN61000-4-2 (Electrostatic Discharge)
- EN61000-4-3 (Radiated Susceptibility)
- EN61000-4-4 (Electrical Fast Transient)
- EN61000-4-5 (Surge Immunity)
- EN61000-4-6 (Conducted Susceptibility)
- EN61000-4-8 (Power Frequency Magnetic Field)
- EN61000-4-11 (Voltage Dips and Interruptions)
Environmental Standards:
- Designed for industrial environments with wide temperature and humidity tolerance.
- Manufactured under ORing’s quality management system ensuring compliance with international industrial networking standards.
Safety Compliance:
- Meets industrial-grade electrical safety requirements for low-voltage DC operation.
- Non-waterproof; intended for indoor or protected installations.
### 9. Additional Information
Warranty:
- Standard Warranty: 5 years (as stated in product documentation)
- Covers manufacturing defects and hardware failures under normal operating conditions.
Support & Maintenance:
- Technical Support:
- Email: support@oring-networking.com
- Phone: +886-2-2218-1066
- Fax: +886-2-2218-1014
- Website: [www.oring-networking.com](http://www.oring-networking.com)
- Maintenance:
- No routine maintenance required.
- Periodic inspection recommended to ensure connector integrity and cleanliness.
- Firmware/Software Updates:
- Not applicable; the DBU-01 operates as a hardware-based configuration transfer device.
Manufacturer Information:
ORing Industrial Networking Corp.
No. 3, Lane 879, Zhongzheng Rd., Zhonghe Dist.,
New Taipei City 235, Taiwan
Tel: +886-2-2218-1066
Fax: +886-2-2218-1014
Email: support@oring-networking.com
Website: [www.oring-networking.com](http://www.oring-networking.com)
Environmental Responsibility:
- Printed documentation produced on recycled paper.
- Device designed for low power consumption and minimal environmental impact.
### Summary
The ORing DBU-01-DB9 Configuration Backup Unit is a purpose-built, industrial-grade tool for managing configuration data across ORing networking devices. Its standalone operation, plug-and-play design, and robust environmental tolerance make it ideal for field engineers, system integrators, and maintenance personnel who require a reliable and portable solution for configuration backup and restoration.
By eliminating the need for external computers or software, the DBU-01-DB9 streamlines configuration management, reduces downtime, and enhances operational efficiency in industrial networking environments. With its dual configuration storage, intuitive DIP switch interface, and comprehensive LED feedback system, it provides a simple yet powerful method for safeguarding and replicating device configurations across ORing’s product ecosystem.
Document Reference:
Quick Installation Guide – DBU-01 Series
Document Code: 1907-2-29-DBU01-1.0
Copyright © 2014 ORing Industrial Networking Corp.
All rights reserved.
### 1. Product Overview
Product Name: Configuration Backup Unit for DB9 Type Console Port
Model: DBU-01-DB9
Series: DBU-01 Series (also includes DBU-01-RJ45 and DBU-01-M12 variants)
Article Number: DBU-01-DB9
Manufacturer: ORing Industrial Networking Corp.
Version: 1.0
Product Type: Standalone configuration backup and restore device for ORing network equipment
Intended Use: Backup and restoration of configuration data for ORing switches, access points (APs), and access routers (ARs) via DB9 console interface
The ORing DBU-01-DB9 is a compact, industrial-grade configuration backup unit designed to simplify the management of ORing networking devices. It enables users to back up and restore configuration data directly through the console port without the need for a PC or external software. The device is powered directly from the connected ORing device, ensuring portability and ease of use in field or industrial environments.
### 2. Key Features
- Standalone Operation: No PC or external power supply required; powered directly via the RS-232 console port (RTS signal).
- Universal Compatibility: Designed for ORing switches, access points, and routers equipped with DB9 console ports.
- Multiple Connector Options: Available in DB9, RJ45, and M12 (5-pin A-coding) versions for different device interfaces.
- Simple Data Management: DIP switch and push-button interface for intuitive upload/download operations.
- Dual Configuration Storage: Two configuration memory locations (A & B) for flexible backup management.
- LED Status Indicators: Clear visual feedback for power, data transmission, and operation status.
- Compact and Rugged Design: Industrial-grade PC-molded enclosure with IP40 protection rating.
- Environmentally Robust: Wide operating temperature range (-10°C to 60°C) and high humidity tolerance (up to 95% non-condensing).
- Regulatory Compliance: Meets FCC Part 15, CISPR (EN55022) Class A, and EN61000-4 series EMC standards.
- Maintenance-Free Operation: No moving parts or external power adapters required.
- Quick Installation: Plug-and-play design for immediate use in field maintenance or configuration replication tasks.
### 3. Technical Specifications
Physical Characteristics
- Enclosure Material: PC molding (industrial-grade plastic)
- Protection Rating: IP40 (protection against solid objects >1 mm; not waterproof)
- Dimensions (W × D × H): 32 × 14.5 × 90 mm (1.25 × 0.57 × 3.5 in)
- Cable Length: 172 mm
- Weight: 53 g (typical)
- Color: Industrial gray/black (standard ORing finish)
Power
- Input Voltage: 5–12 VDC (supplied via RS-232 RTS signal from connected device)
- Power Source: No external power supply required
Environmental Conditions
- Operating Temperature: -10°C to 60°C (14°F to 140°F)
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Operating Humidity: 5% to 95% RH, non-condensing
Regulatory & EMC Compliance
- EMI: FCC Part 15, CISPR (EN55022) Class A
- EMS: EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
### 4. Functionality
The DBU-01-DB9 serves as a portable configuration management tool for ORing network devices. It allows users to back up configuration data from one device and restore it to another without requiring a computer or network connection.
Operating Principle:
1. The unit connects directly to the console port (DB9 interface) of an ORing device.
2. Once connected, the device draws power through the RS-232 RTS signal.
3. The user selects the desired operation (upload or download) using the DIP switch and initiates the process via the Start button.
4. Configuration data is transferred between the DBU-01 and the connected device.
5. LED indicators provide real-time feedback on power, transmission, and success/failure status.
Use Cases:
- Field maintenance and configuration replication for ORing switches, APs, and routers.
- Rapid deployment of standardized configurations across multiple devices.
- Backup of critical configuration data before firmware upgrades or system changes.
- Restoration of device settings after hardware replacement or reset.
Compatibility:
- Compatible exclusively with ORing Industrial Networking devices equipped with DB9 console ports.
- Other models (DBU-01-RJ45, DBU-01-M12) support devices with RJ45 or M12 console interfaces.
### 5. Components & Accessories
Package Contents:
- 1 × DBU-01-DB9 Configuration Backup Unit
- 1 × Quick Installation Guide (QIG)
Included Components:
- Integrated DB9 connector cable (172 mm length)
- Built-in DIP switch (2-pole) for upload/download selection
- Start button for initiating data transfer
- Dual configuration memory selector (A & B)
- LED indicators for power, transmission, and status
Optional Accessories:
- None required; the unit is self-contained.
- Optional variants (DBU-01-RJ45, DBU-01-M12) available for other connector types.
Connectors:
- Console Interface: DB9 male connector (RS-232 standard)
- Power Input: Supplied via RS-232 RTS signal (no external connector)
### 6. Installation & Setup
Pre-Installation Requirements:
- Ensure the target ORing device (switch, AP, or AR) is powered on.
- Verify that the DBU-01 model matches the console port type (DB9).
- Confirm that the device is compatible with the DBU-01 series (refer to ORing datasheet).
Installation Steps:
1. Connect: Insert the DBU-01-DB9 connector into the console port of the ORing device.
2. Power Check: Confirm that the green Power LED illuminates, indicating the unit is powered.
3. Select Operation: Use the DIP switch to choose between Upload (backup) or Download (restore).
4. Initiate Transfer: Press the Start button to begin the selected operation.
5. Monitor LEDs:
- Amber LED blinking: Data transmission in progress.
- Green LED on: Transmission successful.
- Red LED on: Transmission failed.
6. Switch Configuration Memory: Use the Config Location switch (A/B) to select or change the storage slot for configuration data.
Mounting Options:
- Handheld or temporary connection; no permanent mounting required.
- Compact form factor allows easy use in field environments or control cabinets.
Safety Notes:
- The device is not waterproof; avoid exposure to liquids.
- Operate only within specified temperature and humidity ranges.
- Use only with compatible ORing devices to prevent malfunction.
### 7. Performance & Capabilities
Operational Performance:
- Data Transfer Method: Serial communication via RS-232 console interface.
- Backup/Restore Speed: Dependent on device configuration size and console baud rate (typical RS-232 speeds).
- Configuration Storage: Two independent memory slots (A and B) for storing multiple device configurations.
- Power Efficiency: Consumes minimal power directly from the host device (5–12 VDC).
- Reliability: Solid-state design ensures high durability and long operational life.
Efficiency & Usability:
- Eliminates the need for a computer or software tools during configuration management.
- Reduces downtime during device replacement or configuration replication.
- Provides immediate visual feedback through LED indicators for operational assurance.
Limitations:
- Compatible only with ORing devices; not intended for third-party equipment.
- Not suitable for outdoor or high-moisture environments (IP40 rating).
- Limited to console-based configuration data (does not back up firmware or user data).
### 8. Standards & Compliance
Electromagnetic Compatibility (EMC):
- EMI Compliance:
- FCC Part 15 Class A
- CISPR (EN55022) Class A
- EMS Compliance:
- EN61000-4-2 (Electrostatic Discharge)
- EN61000-4-3 (Radiated Susceptibility)
- EN61000-4-4 (Electrical Fast Transient)
- EN61000-4-5 (Surge Immunity)
- EN61000-4-6 (Conducted Susceptibility)
- EN61000-4-8 (Power Frequency Magnetic Field)
- EN61000-4-11 (Voltage Dips and Interruptions)
Environmental Standards:
- Designed for industrial environments with wide temperature and humidity tolerance.
- Manufactured under ORing’s quality management system ensuring compliance with international industrial networking standards.
Safety Compliance:
- Meets industrial-grade electrical safety requirements for low-voltage DC operation.
- Non-waterproof; intended for indoor or protected installations.
### 9. Additional Information
Warranty:
- Standard Warranty: 5 years (as stated in product documentation)
- Covers manufacturing defects and hardware failures under normal operating conditions.
Support & Maintenance:
- Technical Support:
- Email: support@oring-networking.com
- Phone: +886-2-2218-1066
- Fax: +886-2-2218-1014
- Website: [www.oring-networking.com](http://www.oring-networking.com)
- Maintenance:
- No routine maintenance required.
- Periodic inspection recommended to ensure connector integrity and cleanliness.
- Firmware/Software Updates:
- Not applicable; the DBU-01 operates as a hardware-based configuration transfer device.
Manufacturer Information:
ORing Industrial Networking Corp.
No. 3, Lane 879, Zhongzheng Rd., Zhonghe Dist.,
New Taipei City 235, Taiwan
Tel: +886-2-2218-1066
Fax: +886-2-2218-1014
Email: support@oring-networking.com
Website: [www.oring-networking.com](http://www.oring-networking.com)
Environmental Responsibility:
- Printed documentation produced on recycled paper.
- Device designed for low power consumption and minimal environmental impact.
### Summary
The ORing DBU-01-DB9 Configuration Backup Unit is a purpose-built, industrial-grade tool for managing configuration data across ORing networking devices. Its standalone operation, plug-and-play design, and robust environmental tolerance make it ideal for field engineers, system integrators, and maintenance personnel who require a reliable and portable solution for configuration backup and restoration.
By eliminating the need for external computers or software, the DBU-01-DB9 streamlines configuration management, reduces downtime, and enhances operational efficiency in industrial networking environments. With its dual configuration storage, intuitive DIP switch interface, and comprehensive LED feedback system, it provides a simple yet powerful method for safeguarding and replicating device configurations across ORing’s product ecosystem.
Document Reference:
Quick Installation Guide – DBU-01 Series
Document Code: 1907-2-29-DBU01-1.0
Copyright © 2014 ORing Industrial Networking Corp.
All rights reserved.
-
DataSheet_DBU-01_V0.1.pdf
PDF Catalog
-
QIG_DBU-01 Series.pdf
Manual
Kein Zubehör vorhanden.