- Hazardous Location Certification: Certified for C1D2 and ATEX Class I Zone 2 environments, ensuring safe operation in explosive atmospheres.
- High-Speed Connectivity: 6×10/100Base-T(X) and 2×10/100/1000Base-T(X) RJ-45 ports with auto MDI/MDI-X support.
- Redundant Network Technology: Supports ORing’s proprietary O-Ring redundancy (recovery <10 ms over 250 nodes), Open-Ring, O-Chain, and standard STP/RSTP/MSTP protocols.
- Triple Power Input: Three independent DC power inputs (12–48 VDC) for maximum reliability and redundancy.
- Wide Temperature Range: Operates from -40°C to +70°C, suitable for extreme industrial conditions.
- Advanced Management: Web-based GUI, Telnet, CLI, SNMP v1/v2c/v3, and ORing’s Open-Vision centralized management software.
- Security: 802.1x port-based access control, MAC-based port security, IP security lists, SNMPv3 authentication, and RADIUS integration.
- Quality of Service (QoS): IEEE 802.1p prioritization, TOS/DSCP, and weighted fair queuing for real-time traffic management.
- VLAN Support: IEEE 802.1Q VLAN tagging, GVRP, and QinQ for network segmentation and scalability.
- Event Notification: Supports Syslog, SNMP traps, and SMTP email alerts for system events and faults.
- Industrial Design: IP-30 metal enclosure, DIN-rail and wall-mount options, and fanless operation.
- Warranty: 5-year limited warranty.
- High-Speed Connectivity: 6×10/100Base-T(X) and 2×10/100/1000Base-T(X) RJ-45 ports with auto MDI/MDI-X support.
- Redundant Network Technology: Supports ORing’s proprietary O-Ring redundancy (recovery <10 ms over 250 nodes), Open-Ring, O-Chain, and standard STP/RSTP/MSTP protocols.
- Triple Power Input: Three independent DC power inputs (12–48 VDC) for maximum reliability and redundancy.
- Wide Temperature Range: Operates from -40°C to +70°C, suitable for extreme industrial conditions.
- Advanced Management: Web-based GUI, Telnet, CLI, SNMP v1/v2c/v3, and ORing’s Open-Vision centralized management software.
- Security: 802.1x port-based access control, MAC-based port security, IP security lists, SNMPv3 authentication, and RADIUS integration.
- Quality of Service (QoS): IEEE 802.1p prioritization, TOS/DSCP, and weighted fair queuing for real-time traffic management.
- VLAN Support: IEEE 802.1Q VLAN tagging, GVRP, and QinQ for network segmentation and scalability.
- Event Notification: Supports Syslog, SNMP traps, and SMTP email alerts for system events and faults.
- Industrial Design: IP-30 metal enclosure, DIN-rail and wall-mount options, and fanless operation.
- Warranty: 5-year limited warranty.
1. Product Overview
Product Name: Industrial Managed Ethernet Switch
Model: IES-A3062GT
Series: IES-A3 Series
Article Number: IES-A3062GT
Manufacturer: ORing Industrial Networking Corp.
Website: [www.oring-networking.com](http://www.oring-networking.com)
Contact:
- Headquarters: 3F, 542-2 Zhongzheng Road, Xindian District, New Taipei City 231, Taiwan
- Tel: +886-2-2218-1066 | Fax: +886-2-2218-1014
- Email: support@oring-networking.com
The ORing IES-A3062GT is a rugged, managed industrial Ethernet switch designed for hazardous environments such as oil and gas facilities. It is part of the IES-A3 series, which is engineered for high reliability, network redundancy, and advanced management in mission-critical applications. The IES-A3062GT features 8 Ethernet ports—6 Fast Ethernet (10/100Base-TX) and 2 Gigabit Ethernet (10/100/1000Base-TX)—and is certified for Class I Division 2 (C1D2) and ATEX Zone 2 hazardous locations.
2. Key Features
- Hazardous Location Certification: Certified for C1D2 and ATEX Class I Zone 2 environments, ensuring safe operation in explosive atmospheres.
- High-Speed Connectivity: 6×10/100Base-T(X) and 2×10/100/1000Base-T(X) RJ-45 ports with auto MDI/MDI-X support.
- Redundant Network Technology: Supports ORing’s proprietary O-Ring redundancy (recovery <10 ms over 250 nodes), Open-Ring, O-Chain, and standard STP/RSTP/MSTP protocols.
- Triple Power Input: Three independent DC power inputs (12–48 VDC) for maximum reliability and redundancy.
- Wide Temperature Range: Operates from -40°C to +70°C, suitable for extreme industrial conditions.
- Advanced Management: Web-based GUI, Telnet, CLI, SNMP v1/v2c/v3, and ORing’s Open-Vision centralized management software.
- Security: 802.1x port-based access control, MAC-based port security, IP security lists, SNMPv3 authentication, and RADIUS integration.
- Quality of Service (QoS): IEEE 802.1p prioritization, TOS/DSCP, and weighted fair queuing for real-time traffic management.
- VLAN Support: IEEE 802.1Q VLAN tagging, GVRP, and QinQ for network segmentation and scalability.
- Event Notification: Supports Syslog, SNMP traps, and SMTP email alerts for system events and faults.
- Industrial Design: IP-30 metal enclosure, DIN-rail and wall-mount options, and fanless operation.
- Warranty: 5-year limited warranty.
3. Technical Specifications
Ethernet Standards:
IEEE 802.3 (10Base-T), 802.3u (100Base-TX), 802.3z (1000Base-X), 802.3ab (1000Base-T), 802.3ad (LACP), 802.3x (Flow Control), 802.1D (STP), 802.1p (CoS), 802.1Q (VLAN), 802.1w (RSTP), 802.1s (MSTP), 802.1x (Authentication), 802.1ad (QinQ), 802.1AB (LLDP).
Ports:
- 6 × 10/100Base-T(X) RJ-45 (Auto MDI/MDI-X)
- 2 × 10/100/1000Base-T(X) RJ-45 (Auto MDI/MDI-X)
- 1 × RS-232 Console Port (RJ-45 to DB9 cable included)
Performance:
- Switching Bandwidth: 5.2 Gbps
- Switching Latency: <7 µs
- MAC Address Table: 8192 entries
- Priority Queues: 4
- VLANs Supported: 4096
- IGMP Multicast Groups: 1024
- Store-and-Forward switching architecture
Power Requirements:
- Input Voltage: 12–48 VDC (PWR1/2 via 7-pin terminal block; PWR3 via DC jack)
- Power Consumption: 8 W typical
- Reverse Polarity Protection: Yes
- Overload Current Protection: Yes
- Note: Power jack not for use in hazardous locations.
Environmental:
- Operating Temperature: -40°C to +70°C
- Storage Temperature: -40°C to +85°C
- Humidity: 5–95% non-condensing
- Maximum Ambient Air Temperature: 70°C
Mechanical:
- Dimensions (W × D × H): 52 × 106 × 144 mm
- Weight: 722 g
- Enclosure: IP-30 rated metal housing
- Mounting: DIN-rail and wall-mount compatible
4. Functionality
The IES-A3062GT functions as a fully managed Layer 2 industrial Ethernet switch. It provides advanced redundancy, traffic management, and security features for industrial automation, oil and gas, and transportation networks.
Use Cases:
- Oil & gas field control systems
- SCADA and DCS networks
- Industrial automation and process control
- Power substations and renewable energy systems
- Transportation and railway signaling networks
Compatibility:
- Compatible with ORing’s Open-Vision management suite for centralized monitoring.
- Interoperable with third-party SNMP management tools.
- Supports standard Ethernet protocols for seamless integration with existing infrastructure.
Operation:
The switch can be managed via:
- Web Interface: Browser-based configuration and monitoring.
- CLI: Command-line interface via console or Telnet.
- SNMP: Remote management using SNMP v1/v2c/v3.
- Open-Vision Utility: Windows-based centralized management software.
5. Components & Accessories
Included in Package:
- IES-A3062GT switch unit
- DIN-rail mounting kit
- Wall-mount kit
- 7-pin terminal block connector
- RS-232 console cable (RJ-45 to DB9)
- Quick Installation Guide (QIG)
- Product CD (manuals and software)
- Dust covers for RJ-45 ports
- Mounting screws
Optional Accessories:
- External power supplies (12–48 VDC)
- Fiber transceivers (for other IES-A3 variants)
- Open-Vision management software license
Connectors:
- RJ-45 Ethernet ports
- 7-pin terminal block for dual DC input
- DC power jack (PWR3)
- RS-232 console port
6. Installation & Setup
Mounting Options:
- DIN-Rail Installation: Attach the DIN-rail clip to the rear panel and snap onto a standard 35 mm DIN-rail.
- Wall Mounting: Use the included wall-mount bracket and screws; leave 2 mm clearance for sliding installation.
Wiring Guidelines:
- Use 12–48 VDC power input.
- Ground the device properly to minimize EMI.
- Use separate routing for power and signal cables.
- Use CAT5e or higher UTP cables for Ethernet connections (max 100 m).
Console Connection:
- Connect via RS-232 (RJ-45 to DB9 cable).
- Default settings: 115200 bps, 8 data bits, no parity, 1 stop bit, no flow control.
Network Configuration:
- Default IP: 192.168.10.1
- Subnet Mask: 255.255.255.0
- Gateway: 192.168.10.254
- Username/Password: admin/admin
Power Connection:
- Connect V+ and V– to terminal block inputs PWR1 and PWR2.
- Optional PWR3 via DC jack (non-hazardous use only).
7. Performance & Capabilities
- Redundancy: O-Ring recovery <10 ms over 250 nodes; supports Ring Master, Coupling Ring, and Dual Homing topologies.
- Throughput: 5.2 Gbps switching capacity.
- Latency: <7 µs for 64-byte packets.
- QoS: 802.1p, TOS/DSCP, and weighted fair queuing (8:4:2:1 ratio).
- VLAN: 802.1Q VLAN tagging, GVRP, QinQ, and port-based VLANs.
- Security: 802.1x authentication, MAC filtering, IP security lists, SNMPv3 encryption.
- DHCP: Built-in DHCP server/client with IP binding.
- Time Synchronization: SNTP and IEEE 1588 PTP client support.
- Diagnostics: System logs, port statistics, MAC address table, and ping utility.
- Event Handling: Syslog, SNMP traps, and SMTP email alerts for power, link, and topology changes.
- Reliability: Triple power redundancy, fanless design, and industrial-grade components ensure continuous operation.
Limitations:
- Power jack not certified for hazardous use.
- Fiber ports not available on GT model (copper only).
8. Standards & Compliance
Electrical & Safety:
- UL508 (E331061)
- UL/cUL Class I Division 2, Groups A/B/C/D
- ATEX Class I Zone 2 (DEMKO 13 ATEX 1317577X)
- EN60950-1 Safety Standard
EMC & Environmental:
- FCC Part 15 Class A
- EN55022 Class A (CISPR)
- EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
- IEC 60068-2-6 (Vibration), IEC 60068-2-27 (Shock), IEC 60068-2-32 (Free Fall)
ATEX Installation Conditions:
- Must be installed in an IP54-rated ATEX-certified enclosure.
- Accessible only with tools.
- Pollution degree ≤ 2 (IEC 60664-1).
- Cable temperature rating ≥ 104°C.
- Terminal block: Dinkle 5EHDRC-07P (300 V, 15 A, 105°C).
- Prevent transient disturbances >140% of rated voltage.
Applicable Standards:
- IEC 60079-0 Ed.6
- IEC 60079-15 Ed.4
- EN 60079-0:2012
- EN 60079-15:2010
9. Additional Information
Warranty:
5 years limited warranty covering defects in materials and workmanship. Excludes misuse, unauthorized modifications, or improper installation.
Support & Maintenance:
- Technical support via email (support@oring-networking.com).
- Firmware updates available through ORing’s website or Open-Vision utility.
- Configuration backup and restore via TFTP.
- Factory reset available via reset button (5 seconds).
Firmware & Software Updates:
- Upgradeable via Web GUI or TFTP.
- Supports backup/restore of configuration files.
Management Interfaces:
- Web browser (HTTP/HTTPS)
- Telnet/CLI
- SNMP v1/v2c/v3
- ORing Open-Vision software
Monitoring & Diagnostics:
- Real-time port statistics and event logs.
- MAC address table management.
- Ping and loopback tests.
- Syslog and email notifications.
Summary:
The ORing IES-A3062GT is a robust, feature-rich managed Ethernet switch engineered for hazardous industrial environments. Its combination of redundant power inputs, advanced network recovery mechanisms, and comprehensive management capabilities make it ideal for mission-critical oil and gas, energy, and automation networks. With C1D2 and ATEX certifications, wide temperature tolerance, and a 5-year warranty, the IES-A3062GT delivers exceptional reliability, safety, and performance in demanding field applications.
Product Name: Industrial Managed Ethernet Switch
Model: IES-A3062GT
Series: IES-A3 Series
Article Number: IES-A3062GT
Manufacturer: ORing Industrial Networking Corp.
Website: [www.oring-networking.com](http://www.oring-networking.com)
Contact:
- Headquarters: 3F, 542-2 Zhongzheng Road, Xindian District, New Taipei City 231, Taiwan
- Tel: +886-2-2218-1066 | Fax: +886-2-2218-1014
- Email: support@oring-networking.com
The ORing IES-A3062GT is a rugged, managed industrial Ethernet switch designed for hazardous environments such as oil and gas facilities. It is part of the IES-A3 series, which is engineered for high reliability, network redundancy, and advanced management in mission-critical applications. The IES-A3062GT features 8 Ethernet ports—6 Fast Ethernet (10/100Base-TX) and 2 Gigabit Ethernet (10/100/1000Base-TX)—and is certified for Class I Division 2 (C1D2) and ATEX Zone 2 hazardous locations.
2. Key Features
- Hazardous Location Certification: Certified for C1D2 and ATEX Class I Zone 2 environments, ensuring safe operation in explosive atmospheres.
- High-Speed Connectivity: 6×10/100Base-T(X) and 2×10/100/1000Base-T(X) RJ-45 ports with auto MDI/MDI-X support.
- Redundant Network Technology: Supports ORing’s proprietary O-Ring redundancy (recovery <10 ms over 250 nodes), Open-Ring, O-Chain, and standard STP/RSTP/MSTP protocols.
- Triple Power Input: Three independent DC power inputs (12–48 VDC) for maximum reliability and redundancy.
- Wide Temperature Range: Operates from -40°C to +70°C, suitable for extreme industrial conditions.
- Advanced Management: Web-based GUI, Telnet, CLI, SNMP v1/v2c/v3, and ORing’s Open-Vision centralized management software.
- Security: 802.1x port-based access control, MAC-based port security, IP security lists, SNMPv3 authentication, and RADIUS integration.
- Quality of Service (QoS): IEEE 802.1p prioritization, TOS/DSCP, and weighted fair queuing for real-time traffic management.
- VLAN Support: IEEE 802.1Q VLAN tagging, GVRP, and QinQ for network segmentation and scalability.
- Event Notification: Supports Syslog, SNMP traps, and SMTP email alerts for system events and faults.
- Industrial Design: IP-30 metal enclosure, DIN-rail and wall-mount options, and fanless operation.
- Warranty: 5-year limited warranty.
3. Technical Specifications
Ethernet Standards:
IEEE 802.3 (10Base-T), 802.3u (100Base-TX), 802.3z (1000Base-X), 802.3ab (1000Base-T), 802.3ad (LACP), 802.3x (Flow Control), 802.1D (STP), 802.1p (CoS), 802.1Q (VLAN), 802.1w (RSTP), 802.1s (MSTP), 802.1x (Authentication), 802.1ad (QinQ), 802.1AB (LLDP).
Ports:
- 6 × 10/100Base-T(X) RJ-45 (Auto MDI/MDI-X)
- 2 × 10/100/1000Base-T(X) RJ-45 (Auto MDI/MDI-X)
- 1 × RS-232 Console Port (RJ-45 to DB9 cable included)
Performance:
- Switching Bandwidth: 5.2 Gbps
- Switching Latency: <7 µs
- MAC Address Table: 8192 entries
- Priority Queues: 4
- VLANs Supported: 4096
- IGMP Multicast Groups: 1024
- Store-and-Forward switching architecture
Power Requirements:
- Input Voltage: 12–48 VDC (PWR1/2 via 7-pin terminal block; PWR3 via DC jack)
- Power Consumption: 8 W typical
- Reverse Polarity Protection: Yes
- Overload Current Protection: Yes
- Note: Power jack not for use in hazardous locations.
Environmental:
- Operating Temperature: -40°C to +70°C
- Storage Temperature: -40°C to +85°C
- Humidity: 5–95% non-condensing
- Maximum Ambient Air Temperature: 70°C
Mechanical:
- Dimensions (W × D × H): 52 × 106 × 144 mm
- Weight: 722 g
- Enclosure: IP-30 rated metal housing
- Mounting: DIN-rail and wall-mount compatible
4. Functionality
The IES-A3062GT functions as a fully managed Layer 2 industrial Ethernet switch. It provides advanced redundancy, traffic management, and security features for industrial automation, oil and gas, and transportation networks.
Use Cases:
- Oil & gas field control systems
- SCADA and DCS networks
- Industrial automation and process control
- Power substations and renewable energy systems
- Transportation and railway signaling networks
Compatibility:
- Compatible with ORing’s Open-Vision management suite for centralized monitoring.
- Interoperable with third-party SNMP management tools.
- Supports standard Ethernet protocols for seamless integration with existing infrastructure.
Operation:
The switch can be managed via:
- Web Interface: Browser-based configuration and monitoring.
- CLI: Command-line interface via console or Telnet.
- SNMP: Remote management using SNMP v1/v2c/v3.
- Open-Vision Utility: Windows-based centralized management software.
5. Components & Accessories
Included in Package:
- IES-A3062GT switch unit
- DIN-rail mounting kit
- Wall-mount kit
- 7-pin terminal block connector
- RS-232 console cable (RJ-45 to DB9)
- Quick Installation Guide (QIG)
- Product CD (manuals and software)
- Dust covers for RJ-45 ports
- Mounting screws
Optional Accessories:
- External power supplies (12–48 VDC)
- Fiber transceivers (for other IES-A3 variants)
- Open-Vision management software license
Connectors:
- RJ-45 Ethernet ports
- 7-pin terminal block for dual DC input
- DC power jack (PWR3)
- RS-232 console port
6. Installation & Setup
Mounting Options:
- DIN-Rail Installation: Attach the DIN-rail clip to the rear panel and snap onto a standard 35 mm DIN-rail.
- Wall Mounting: Use the included wall-mount bracket and screws; leave 2 mm clearance for sliding installation.
Wiring Guidelines:
- Use 12–48 VDC power input.
- Ground the device properly to minimize EMI.
- Use separate routing for power and signal cables.
- Use CAT5e or higher UTP cables for Ethernet connections (max 100 m).
Console Connection:
- Connect via RS-232 (RJ-45 to DB9 cable).
- Default settings: 115200 bps, 8 data bits, no parity, 1 stop bit, no flow control.
Network Configuration:
- Default IP: 192.168.10.1
- Subnet Mask: 255.255.255.0
- Gateway: 192.168.10.254
- Username/Password: admin/admin
Power Connection:
- Connect V+ and V– to terminal block inputs PWR1 and PWR2.
- Optional PWR3 via DC jack (non-hazardous use only).
7. Performance & Capabilities
- Redundancy: O-Ring recovery <10 ms over 250 nodes; supports Ring Master, Coupling Ring, and Dual Homing topologies.
- Throughput: 5.2 Gbps switching capacity.
- Latency: <7 µs for 64-byte packets.
- QoS: 802.1p, TOS/DSCP, and weighted fair queuing (8:4:2:1 ratio).
- VLAN: 802.1Q VLAN tagging, GVRP, QinQ, and port-based VLANs.
- Security: 802.1x authentication, MAC filtering, IP security lists, SNMPv3 encryption.
- DHCP: Built-in DHCP server/client with IP binding.
- Time Synchronization: SNTP and IEEE 1588 PTP client support.
- Diagnostics: System logs, port statistics, MAC address table, and ping utility.
- Event Handling: Syslog, SNMP traps, and SMTP email alerts for power, link, and topology changes.
- Reliability: Triple power redundancy, fanless design, and industrial-grade components ensure continuous operation.
Limitations:
- Power jack not certified for hazardous use.
- Fiber ports not available on GT model (copper only).
8. Standards & Compliance
Electrical & Safety:
- UL508 (E331061)
- UL/cUL Class I Division 2, Groups A/B/C/D
- ATEX Class I Zone 2 (DEMKO 13 ATEX 1317577X)
- EN60950-1 Safety Standard
EMC & Environmental:
- FCC Part 15 Class A
- EN55022 Class A (CISPR)
- EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
- IEC 60068-2-6 (Vibration), IEC 60068-2-27 (Shock), IEC 60068-2-32 (Free Fall)
ATEX Installation Conditions:
- Must be installed in an IP54-rated ATEX-certified enclosure.
- Accessible only with tools.
- Pollution degree ≤ 2 (IEC 60664-1).
- Cable temperature rating ≥ 104°C.
- Terminal block: Dinkle 5EHDRC-07P (300 V, 15 A, 105°C).
- Prevent transient disturbances >140% of rated voltage.
Applicable Standards:
- IEC 60079-0 Ed.6
- IEC 60079-15 Ed.4
- EN 60079-0:2012
- EN 60079-15:2010
9. Additional Information
Warranty:
5 years limited warranty covering defects in materials and workmanship. Excludes misuse, unauthorized modifications, or improper installation.
Support & Maintenance:
- Technical support via email (support@oring-networking.com).
- Firmware updates available through ORing’s website or Open-Vision utility.
- Configuration backup and restore via TFTP.
- Factory reset available via reset button (5 seconds).
Firmware & Software Updates:
- Upgradeable via Web GUI or TFTP.
- Supports backup/restore of configuration files.
Management Interfaces:
- Web browser (HTTP/HTTPS)
- Telnet/CLI
- SNMP v1/v2c/v3
- ORing Open-Vision software
Monitoring & Diagnostics:
- Real-time port statistics and event logs.
- MAC address table management.
- Ping and loopback tests.
- Syslog and email notifications.
Summary:
The ORing IES-A3062GT is a robust, feature-rich managed Ethernet switch engineered for hazardous industrial environments. Its combination of redundant power inputs, advanced network recovery mechanisms, and comprehensive management capabilities make it ideal for mission-critical oil and gas, energy, and automation networks. With C1D2 and ATEX certifications, wide temperature tolerance, and a 5-year warranty, the IES-A3062GT delivers exceptional reliability, safety, and performance in demanding field applications.
-
Datasheet_IES-A3080_IESA3062_Series_v1.0.pdf
PDF Catalog
-
QIG_IES-A3080_3062_V1.0.pdf
Manual
Kein Zubehör vorhanden.