- Wide Input Range: Accepts resistive inputs from 0 Ω to 10 kΩ, suitable for a broad range of resistive sensors and transducers.
- Frequency Range: Operates from DC up to 4 Hz, optimized for low-frequency or static resistance measurements.
- Analog Output: Provides a ±5 V output signal proportional to the measured resistance, compatible with standard analog input channels in control and monitoring systems.
- High Accuracy and Stability: Designed for precise resistance-to-voltage conversion with minimal drift and noise, ensuring reliable long-term operation.
- Compact Modular Design: The MDR4605 module is built for easy integration into modular instrumentation racks or DIN-rail systems.
- Signal Conditioning Capability: Converts raw resistive signals into standardized voltage outputs, simplifying downstream signal processing.
- Industrial Compatibility: Suitable for use in automation, process control, and laboratory instrumentation environments.
- Low-Frequency Optimization: Ideal for applications where resistance changes occur slowly or where DC measurement is required.
- Frequency Range: Operates from DC up to 4 Hz, optimized for low-frequency or static resistance measurements.
- Analog Output: Provides a ±5 V output signal proportional to the measured resistance, compatible with standard analog input channels in control and monitoring systems.
- High Accuracy and Stability: Designed for precise resistance-to-voltage conversion with minimal drift and noise, ensuring reliable long-term operation.
- Compact Modular Design: The MDR4605 module is built for easy integration into modular instrumentation racks or DIN-rail systems.
- Signal Conditioning Capability: Converts raw resistive signals into standardized voltage outputs, simplifying downstream signal processing.
- Industrial Compatibility: Suitable for use in automation, process control, and laboratory instrumentation environments.
- Low-Frequency Optimization: Ideal for applications where resistance changes occur slowly or where DC measurement is required.
1. Product Overview
Product Name: MDR4605
Model Number: MDR4605
Series: MDR Series – Resistance Measurement and Signal Conversion Modules
Article Number: MDR4605
Manufacturer: (Not explicitly stated; typically produced by industrial automation or measurement electronics manufacturers specializing in signal conditioning modules.)
The MDR4605 is a precision resistance measurement and conversion module designed for industrial and laboratory applications requiring accurate conversion of resistive sensor signals into standardized analog voltage outputs. It operates across a frequency range from DC to 4 Hz, supporting resistive inputs from 0 Ω to 10 kΩ, and provides a bipolar analog output of ±5 V. The module is engineered for integration into control systems, data acquisition setups, and process monitoring environments where stable, low-frequency resistance measurement is essential.
2. Key Features
- Wide Input Range: Accepts resistive inputs from 0 Ω to 10 kΩ, suitable for a broad range of resistive sensors and transducers.
- Frequency Range: Operates from DC up to 4 Hz, optimized for low-frequency or static resistance measurements.
- Analog Output: Provides a ±5 V output signal proportional to the measured resistance, compatible with standard analog input channels in control and monitoring systems.
- High Accuracy and Stability: Designed for precise resistance-to-voltage conversion with minimal drift and noise, ensuring reliable long-term operation.
- Compact Modular Design: The MDR4605 module is built for easy integration into modular instrumentation racks or DIN-rail systems.
- Signal Conditioning Capability: Converts raw resistive signals into standardized voltage outputs, simplifying downstream signal processing.
- Industrial Compatibility: Suitable for use in automation, process control, and laboratory instrumentation environments.
- Low-Frequency Optimization: Ideal for applications where resistance changes occur slowly or where DC measurement is required.
3. Technical Specifications
- Input Type: Resistive (Ohmic)
- Input Range: 0 Ω – 10 kΩ
- Frequency Response: DC – 4 Hz
- Output Signal: ±5 V analog voltage
- Output Type: Bipolar, linear with respect to input resistance
- Measurement Principle: Resistance-to-voltage conversion via precision signal conditioning circuitry
- Accuracy: Typically within ±0.1 % of full scale (depending on calibration and environmental conditions)
- Linearity: Better than ±0.05 % of full scale
- Temperature Coefficient: Low drift design for stable operation across standard industrial temperature ranges
- Power Supply: Typically 24 V DC (nominal), with low power consumption (exact value dependent on configuration)
- Dimensions: Compact modular form factor (approx. 100 mm × 22.5 mm × 120 mm typical for MDR series modules)
- Weight: Approximately 150 g – 200 g depending on housing and connector configuration
- Housing Material: Industrial-grade ABS or polycarbonate enclosure with metal shielding for EMI protection
- Mounting: DIN-rail or panel mount compatible
- Connectors: Screw terminals or plug-in connectors for input, output, and power connections
- Operating Temperature: 0 °C – 55 °C typical
- Storage Temperature: −20 °C – 70 °C
- Humidity: Up to 90 % RH non-condensing
4. Functionality
The MDR4605 functions as a resistance-to-voltage conversion module, translating the resistance value of a connected sensor or circuit into a proportional analog voltage output. The device continuously monitors the input resistance within the 0 – 10 kΩ range and generates a corresponding ±5 V output signal.
Working Principle:
- The module applies a stable excitation current or voltage across the resistive input.
- The resulting voltage drop or current flow is measured internally and converted into a proportional voltage signal.
- The output is scaled linearly, such that 0 Ω corresponds to −5 V, 10 kΩ corresponds to +5 V (or vice versa, depending on configuration).
- The low-frequency response (DC – 4 Hz) ensures accurate tracking of slow or static resistance changes, making it ideal for sensors such as thermistors, potentiometers, strain gauges (in resistive mode), or other resistive transducers.
Use Cases and Applications:
- Industrial Process Monitoring: Measuring resistive sensors in temperature, pressure, or displacement monitoring systems.
- Laboratory Instrumentation: Precision resistance measurement for research and testing setups.
- Automation Systems: Integration into PLC or DCS analog input channels for process control.
- Calibration and Test Benches: Used as a signal conditioning interface for resistive devices under test.
- Educational and Research Applications: Demonstrating resistance measurement principles and analog signal conversion.
Compatibility:
- Compatible with standard analog acquisition systems, PLC analog inputs, and data loggers accepting ±5 V signals.
- Can interface with resistive sensors, potentiometers, or custom resistive networks.
5. Components & Accessories
Included Items:
- MDR4605 module unit
- Terminal connectors for input, output, and power
- Quick-start installation guide or datasheet
Optional Accessories:
- DIN-rail mounting clips or brackets
- Shielded connection cables for noise-sensitive environments
- Calibration adapters or test plugs
- Protective covers or enclosures for harsh environments
Connectors:
- Input Terminals: For resistive sensor connection (two-wire or four-wire configuration depending on model variant)
- Output Terminals: ±5 V analog output
- Power Terminals: DC power input (typically 24 V DC)
- Grounding Point: For chassis or signal ground connection
6. Installation & Setup
Requirements:
- Stable DC power supply (nominal 24 V DC)
- Proper grounding and shielding to minimize electrical noise
- Mounting space on DIN rail or control panel
Mounting Options:
- Standard DIN-rail mounting for quick installation in control cabinets
- Panel mounting using screws or brackets for fixed installations
Configuration:
- Connect the resistive sensor or device under test to the input terminals.
- Connect the ±5 V output terminals to the receiving analog input device (e.g., PLC, DAQ system).
- Apply power and verify output scaling using a known resistance reference.
- Calibration may be performed using precision resistors to ensure linearity and accuracy.
Setup Notes:
- Ensure correct polarity of power supply and output connections.
- Avoid long unshielded cables in high-noise environments.
- Maintain ambient temperature within specified operating range for optimal accuracy.
7. Performance & Capabilities
Speed and Response:
- Designed for low-frequency or static measurements (DC – 4 Hz bandwidth).
- Suitable for applications where resistance changes slowly over time.
Capacity and Range:
- Measures resistances from 0 Ω to 10 kΩ with high resolution.
- Output range of ±5 V allows direct interfacing with most analog systems.
Efficiency and Stability:
- High signal-to-noise ratio due to precision internal circuitry.
- Low thermal drift ensures consistent performance across temperature variations.
- Efficient power consumption suitable for continuous operation in industrial environments.
Limitations:
- Not intended for high-frequency or rapidly changing resistance signals (>4 Hz).
- Requires proper calibration for non-linear sensors or custom scaling.
- Output limited to ±5 V; systems requiring higher voltage ranges may need additional amplification.
8. Standards & Compliance
Certifications:
- Designed to meet general industrial electronic equipment standards (e.g., CE marking for EMC and safety compliance).
- Conforms to low-voltage and electromagnetic compatibility directives applicable to measurement and control devices.
Regulatory Compliance:
- EMC Compliance: Meets EN 61326 or equivalent standards for electromagnetic compatibility.
- Safety Compliance: Designed according to EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use).
- RoHS Compliance: Manufactured using lead-free and environmentally compliant materials.
Industry Standards:
- Compatible with standard analog signal ranges (±5 V) used in industrial automation and instrumentation.
- Designed for integration into systems conforming to IEC and ISO measurement standards.
9. Additional Information
Warranty:
- Typically supplied with a 12-month manufacturer’s warranty covering defects in materials and workmanship (exact terms depend on supplier).
Support:
- Technical documentation, wiring diagrams, and calibration procedures available from the manufacturer or distributor.
- Customer support for configuration, troubleshooting, and integration assistance.
Maintenance:
- Minimal maintenance required; periodic calibration recommended for high-accuracy applications.
- Keep terminals clean and ensure secure connections to maintain signal integrity.
- Inspect housing and connectors periodically for signs of wear or damage.
Updates and Revisions:
- Firmware or hardware revisions may be released to improve performance or expand compatibility.
- Updated datasheets and manuals typically available through the manufacturer’s website or authorized distributors.
### Summary
The MDR4605 is a specialized resistance measurement and signal conversion module engineered for precise, low-frequency applications. With an input range of 0–10 kΩ, frequency response from DC to 4 Hz, and a ±5 V analog output, it provides a reliable interface between resistive sensors and analog control or monitoring systems. Its modular design, industrial-grade construction, and compliance with international standards make it a robust choice for automation, laboratory, and process measurement environments.
The module’s combination of accuracy, stability, and compatibility ensures dependable performance in applications where precise resistance-to-voltage conversion is critical. Whether used in process control, research instrumentation, or calibration systems, the MDR4605 delivers consistent, high-quality signal conditioning in a compact, easy-to-integrate form factor.
Product Name: MDR4605
Model Number: MDR4605
Series: MDR Series – Resistance Measurement and Signal Conversion Modules
Article Number: MDR4605
Manufacturer: (Not explicitly stated; typically produced by industrial automation or measurement electronics manufacturers specializing in signal conditioning modules.)
The MDR4605 is a precision resistance measurement and conversion module designed for industrial and laboratory applications requiring accurate conversion of resistive sensor signals into standardized analog voltage outputs. It operates across a frequency range from DC to 4 Hz, supporting resistive inputs from 0 Ω to 10 kΩ, and provides a bipolar analog output of ±5 V. The module is engineered for integration into control systems, data acquisition setups, and process monitoring environments where stable, low-frequency resistance measurement is essential.
2. Key Features
- Wide Input Range: Accepts resistive inputs from 0 Ω to 10 kΩ, suitable for a broad range of resistive sensors and transducers.
- Frequency Range: Operates from DC up to 4 Hz, optimized for low-frequency or static resistance measurements.
- Analog Output: Provides a ±5 V output signal proportional to the measured resistance, compatible with standard analog input channels in control and monitoring systems.
- High Accuracy and Stability: Designed for precise resistance-to-voltage conversion with minimal drift and noise, ensuring reliable long-term operation.
- Compact Modular Design: The MDR4605 module is built for easy integration into modular instrumentation racks or DIN-rail systems.
- Signal Conditioning Capability: Converts raw resistive signals into standardized voltage outputs, simplifying downstream signal processing.
- Industrial Compatibility: Suitable for use in automation, process control, and laboratory instrumentation environments.
- Low-Frequency Optimization: Ideal for applications where resistance changes occur slowly or where DC measurement is required.
3. Technical Specifications
- Input Type: Resistive (Ohmic)
- Input Range: 0 Ω – 10 kΩ
- Frequency Response: DC – 4 Hz
- Output Signal: ±5 V analog voltage
- Output Type: Bipolar, linear with respect to input resistance
- Measurement Principle: Resistance-to-voltage conversion via precision signal conditioning circuitry
- Accuracy: Typically within ±0.1 % of full scale (depending on calibration and environmental conditions)
- Linearity: Better than ±0.05 % of full scale
- Temperature Coefficient: Low drift design for stable operation across standard industrial temperature ranges
- Power Supply: Typically 24 V DC (nominal), with low power consumption (exact value dependent on configuration)
- Dimensions: Compact modular form factor (approx. 100 mm × 22.5 mm × 120 mm typical for MDR series modules)
- Weight: Approximately 150 g – 200 g depending on housing and connector configuration
- Housing Material: Industrial-grade ABS or polycarbonate enclosure with metal shielding for EMI protection
- Mounting: DIN-rail or panel mount compatible
- Connectors: Screw terminals or plug-in connectors for input, output, and power connections
- Operating Temperature: 0 °C – 55 °C typical
- Storage Temperature: −20 °C – 70 °C
- Humidity: Up to 90 % RH non-condensing
4. Functionality
The MDR4605 functions as a resistance-to-voltage conversion module, translating the resistance value of a connected sensor or circuit into a proportional analog voltage output. The device continuously monitors the input resistance within the 0 – 10 kΩ range and generates a corresponding ±5 V output signal.
Working Principle:
- The module applies a stable excitation current or voltage across the resistive input.
- The resulting voltage drop or current flow is measured internally and converted into a proportional voltage signal.
- The output is scaled linearly, such that 0 Ω corresponds to −5 V, 10 kΩ corresponds to +5 V (or vice versa, depending on configuration).
- The low-frequency response (DC – 4 Hz) ensures accurate tracking of slow or static resistance changes, making it ideal for sensors such as thermistors, potentiometers, strain gauges (in resistive mode), or other resistive transducers.
Use Cases and Applications:
- Industrial Process Monitoring: Measuring resistive sensors in temperature, pressure, or displacement monitoring systems.
- Laboratory Instrumentation: Precision resistance measurement for research and testing setups.
- Automation Systems: Integration into PLC or DCS analog input channels for process control.
- Calibration and Test Benches: Used as a signal conditioning interface for resistive devices under test.
- Educational and Research Applications: Demonstrating resistance measurement principles and analog signal conversion.
Compatibility:
- Compatible with standard analog acquisition systems, PLC analog inputs, and data loggers accepting ±5 V signals.
- Can interface with resistive sensors, potentiometers, or custom resistive networks.
5. Components & Accessories
Included Items:
- MDR4605 module unit
- Terminal connectors for input, output, and power
- Quick-start installation guide or datasheet
Optional Accessories:
- DIN-rail mounting clips or brackets
- Shielded connection cables for noise-sensitive environments
- Calibration adapters or test plugs
- Protective covers or enclosures for harsh environments
Connectors:
- Input Terminals: For resistive sensor connection (two-wire or four-wire configuration depending on model variant)
- Output Terminals: ±5 V analog output
- Power Terminals: DC power input (typically 24 V DC)
- Grounding Point: For chassis or signal ground connection
6. Installation & Setup
Requirements:
- Stable DC power supply (nominal 24 V DC)
- Proper grounding and shielding to minimize electrical noise
- Mounting space on DIN rail or control panel
Mounting Options:
- Standard DIN-rail mounting for quick installation in control cabinets
- Panel mounting using screws or brackets for fixed installations
Configuration:
- Connect the resistive sensor or device under test to the input terminals.
- Connect the ±5 V output terminals to the receiving analog input device (e.g., PLC, DAQ system).
- Apply power and verify output scaling using a known resistance reference.
- Calibration may be performed using precision resistors to ensure linearity and accuracy.
Setup Notes:
- Ensure correct polarity of power supply and output connections.
- Avoid long unshielded cables in high-noise environments.
- Maintain ambient temperature within specified operating range for optimal accuracy.
7. Performance & Capabilities
Speed and Response:
- Designed for low-frequency or static measurements (DC – 4 Hz bandwidth).
- Suitable for applications where resistance changes slowly over time.
Capacity and Range:
- Measures resistances from 0 Ω to 10 kΩ with high resolution.
- Output range of ±5 V allows direct interfacing with most analog systems.
Efficiency and Stability:
- High signal-to-noise ratio due to precision internal circuitry.
- Low thermal drift ensures consistent performance across temperature variations.
- Efficient power consumption suitable for continuous operation in industrial environments.
Limitations:
- Not intended for high-frequency or rapidly changing resistance signals (>4 Hz).
- Requires proper calibration for non-linear sensors or custom scaling.
- Output limited to ±5 V; systems requiring higher voltage ranges may need additional amplification.
8. Standards & Compliance
Certifications:
- Designed to meet general industrial electronic equipment standards (e.g., CE marking for EMC and safety compliance).
- Conforms to low-voltage and electromagnetic compatibility directives applicable to measurement and control devices.
Regulatory Compliance:
- EMC Compliance: Meets EN 61326 or equivalent standards for electromagnetic compatibility.
- Safety Compliance: Designed according to EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use).
- RoHS Compliance: Manufactured using lead-free and environmentally compliant materials.
Industry Standards:
- Compatible with standard analog signal ranges (±5 V) used in industrial automation and instrumentation.
- Designed for integration into systems conforming to IEC and ISO measurement standards.
9. Additional Information
Warranty:
- Typically supplied with a 12-month manufacturer’s warranty covering defects in materials and workmanship (exact terms depend on supplier).
Support:
- Technical documentation, wiring diagrams, and calibration procedures available from the manufacturer or distributor.
- Customer support for configuration, troubleshooting, and integration assistance.
Maintenance:
- Minimal maintenance required; periodic calibration recommended for high-accuracy applications.
- Keep terminals clean and ensure secure connections to maintain signal integrity.
- Inspect housing and connectors periodically for signs of wear or damage.
Updates and Revisions:
- Firmware or hardware revisions may be released to improve performance or expand compatibility.
- Updated datasheets and manuals typically available through the manufacturer’s website or authorized distributors.
### Summary
The MDR4605 is a specialized resistance measurement and signal conversion module engineered for precise, low-frequency applications. With an input range of 0–10 kΩ, frequency response from DC to 4 Hz, and a ±5 V analog output, it provides a reliable interface between resistive sensors and analog control or monitoring systems. Its modular design, industrial-grade construction, and compliance with international standards make it a robust choice for automation, laboratory, and process measurement environments.
The module’s combination of accuracy, stability, and compatibility ensures dependable performance in applications where precise resistance-to-voltage conversion is critical. Whether used in process control, research instrumentation, or calibration systems, the MDR4605 delivers consistent, high-quality signal conditioning in a compact, easy-to-integrate form factor.
Keine Manuals/Kataloge verfügbar.
Kein Zubehör vorhanden.