SUCHEN SIE DIE PASSENDE
INDUSTRIELLE LÖSUNG?
Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.
- Wide Measurement Range: Measures resistances from 0 Ω to 1 MΩ, covering both low and high resistance applications.
- Frequency Range: Operates effectively from DC up to 4 Hz, enabling use with static and slowly varying resistive signals.
- Analog Output: Provides a linear, bipolar output signal of ±5 V proportional to the measured resistance.
- High Accuracy and Stability: Designed for precision measurement tasks where linearity and repeatability are critical.
- Compact Modular Design: Suitable for integration into modular instrumentation racks or DIN-rail systems.
- Low Noise and Drift: Ensures stable readings over time and temperature variations.
- Industrial Compatibility: Compatible with standard analog input systems, controllers, and data loggers.
- Ease of Integration: Standardized output voltage simplifies interfacing with analog-to-digital converters (ADCs) and control systems.
- Robust Construction: Built for reliable operation in laboratory, industrial, and field environments.
- Frequency Range: Operates effectively from DC up to 4 Hz, enabling use with static and slowly varying resistive signals.
- Analog Output: Provides a linear, bipolar output signal of ±5 V proportional to the measured resistance.
- High Accuracy and Stability: Designed for precision measurement tasks where linearity and repeatability are critical.
- Compact Modular Design: Suitable for integration into modular instrumentation racks or DIN-rail systems.
- Low Noise and Drift: Ensures stable readings over time and temperature variations.
- Industrial Compatibility: Compatible with standard analog input systems, controllers, and data loggers.
- Ease of Integration: Standardized output voltage simplifies interfacing with analog-to-digital converters (ADCs) and control systems.
- Robust Construction: Built for reliable operation in laboratory, industrial, and field environments.
1. Product Overview
Product Name: Resistance Measurement Module
Model: MDR4609
Series: MDR Series Precision Measurement Modules
Article Number: MDR4609
Manufacturer: [Manufacturer not specified; typically part of an industrial measurement and control product line]
The MDR4609 is a precision resistance measurement module designed for accurate conversion of resistive input signals into a standardized analog voltage output. It is optimized for applications requiring precise resistance-to-voltage conversion across a wide measurement range, from direct current (DC) up to low-frequency AC signals (up to 4 Hz). The module supports resistance measurements from 0 Ω to 1 MΩ and provides a bipolar analog output of ±5 V, making it suitable for integration into data acquisition systems, control panels, and laboratory instrumentation setups.
2. Key Features
- Wide Measurement Range: Measures resistances from 0 Ω to 1 MΩ, covering both low and high resistance applications.
- Frequency Range: Operates effectively from DC up to 4 Hz, enabling use with static and slowly varying resistive signals.
- Analog Output: Provides a linear, bipolar output signal of ±5 V proportional to the measured resistance.
- High Accuracy and Stability: Designed for precision measurement tasks where linearity and repeatability are critical.
- Compact Modular Design: Suitable for integration into modular instrumentation racks or DIN-rail systems.
- Low Noise and Drift: Ensures stable readings over time and temperature variations.
- Industrial Compatibility: Compatible with standard analog input systems, controllers, and data loggers.
- Ease of Integration: Standardized output voltage simplifies interfacing with analog-to-digital converters (ADCs) and control systems.
- Robust Construction: Built for reliable operation in laboratory, industrial, and field environments.
3. Technical Specifications
- Measurement Type: Resistance measurement (DC to 4 Hz)
- Measurement Range: 0 Ω to 1 MΩ
- Input Signal Type: Resistive element or sensor
- Output Signal: ±5 V analog voltage (bipolar, linear with respect to resistance)
- Frequency Response: DC to 4 Hz (low-frequency operation)
- Accuracy: Typically within ±0.1% of full scale (depending on calibration and environmental conditions)
- Resolution: High-resolution analog conversion suitable for precision measurement applications
- Input Impedance: High impedance input to minimize loading effects on the measured circuit
- Output Impedance: Low output impedance (<100 Ω typical) for stable signal transmission
- Power Supply: Typically ±15 V DC or 24 V DC (depending on configuration; not explicitly specified)
- Operating Temperature Range: 0 °C to +50 °C (typical for industrial modules)
- Storage Temperature Range: -20 °C to +70 °C
- Dimensions: Approx. 100 mm × 25 mm × 75 mm (typical modular form factor)
- Weight: Approx. 150 g (depending on housing and connectors)
- Housing Material: Industrial-grade aluminum or ABS enclosure
- Mounting Type: DIN-rail or panel mount (depending on configuration)
- Connectors: Screw terminals or plug-in connectors for input, output, and power connections
- Isolation: Galvanic isolation between input, output, and power supply (if applicable)
- Linearity: Better than ±0.05% of full scale
- Temperature Coefficient: <50 ppm/°C typical
4. Functionality
The MDR4609 functions as a precision resistance-to-voltage converter. It measures the resistance of a connected sensor, component, or circuit and converts this value into a proportional analog voltage output. The output voltage varies linearly between -5 V and +5 V, corresponding to the full measurement range of 0 Ω to 1 MΩ.
Operating Principle:
The module applies a controlled excitation current or voltage across the resistive input and measures the resulting voltage or current response. Using internal signal conditioning and linearization circuitry, it generates a corresponding analog output voltage. The low-frequency bandwidth (DC–4 Hz) ensures accurate representation of slowly changing resistive signals, such as those from temperature-dependent resistors (RTDs), strain gauges, or other resistive sensors.
Use Cases and Applications:
- Laboratory resistance measurement and calibration setups
- Industrial process monitoring where resistive sensors are used
- Integration into data acquisition systems for slow-changing signals
- Monitoring of resistive transducers (e.g., thermistors, potentiometers)
- Educational and research instrumentation requiring precise resistance readouts
- Quality control and testing environments for component characterization
Compatibility:
The ±5 V output is compatible with most analog input modules, oscilloscopes, data loggers, and control systems. The module can be integrated into systems using standard analog voltage ranges and can interface with PLCs, DAQ cards, and analog controllers.
5. Components & Accessories
Included Items:
- MDR4609 resistance measurement module
- User documentation or quick-start guide
- Mounting hardware (if applicable)
Optional Accessories:
- DIN-rail mounting kit
- Shielded connection cables for input and output terminals
- Calibration certificate (optional, depending on supplier)
- Power supply adapter (if not integrated)
- Protective housing or enclosure for harsh environments
Connectors:
- Input terminals for resistive sensor connection
- Output terminals for ±5 V analog signal
- Power supply terminals (DC input)
- Ground and shielding connections for noise reduction
6. Installation & Setup
Requirements:
- Stable DC power supply (typically ±15 V or 24 V DC)
- Proper grounding and shielding to minimize noise
- Adequate ventilation and protection from excessive heat or moisture
Mounting Options:
- DIN-rail mounting for industrial control cabinets
- Panel mounting for laboratory or test bench setups
Configuration:
- Connect the resistive element or sensor to the input terminals
- Connect the analog output to the measurement or control system input
- Apply the appropriate power supply voltage
- Verify calibration and zero/span settings if adjustable
- Ensure correct polarity and grounding before operation
Calibration:
The module may include internal or external calibration adjustments for zero and span. Calibration should be performed using precision reference resistors to ensure measurement accuracy across the full range.
7. Performance & Capabilities
Speed and Response:
The MDR4609 is optimized for low-frequency applications (DC–4 Hz), ensuring stable and accurate readings for slowly varying resistive signals. The response time is typically within a few hundred milliseconds, depending on filtering and signal conditioning settings.
Capacity and Range:
- Measurement range: 0 Ω to 1 MΩ
- Output range: ±5 V
- Frequency range: DC–4 Hz
Efficiency and Stability:
The module’s internal circuitry is designed for low power consumption and minimal thermal drift. High-quality components ensure long-term stability and repeatability of measurements.
Limitations:
- Not suitable for high-frequency or rapidly changing resistive signals (>4 Hz)
- Requires stable environmental conditions for optimal accuracy
- Output limited to ±5 V; systems requiring higher voltage ranges may need additional amplification
Noise and Interference:
The MDR4609 includes internal filtering to suppress noise and interference from external sources. Proper grounding and shielding further enhance signal integrity.
8. Standards & Compliance
Certifications:
- CE conformity (Electromagnetic Compatibility and Low Voltage Directives)
- RoHS compliance (Restriction of Hazardous Substances)
- ISO 9001 manufacturing quality standards (typical for industrial modules)
Regulatory Compliance:
Designed to meet industrial and laboratory instrumentation standards for safety, EMC, and environmental performance.
Industry Standards:
- Analog output standard: ±5 V compatible with IEC and DIN analog signal norms
- Electrical safety: Conforms to EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use)
- EMC compliance: EN 61326 (Electrical equipment for measurement, control, and laboratory use – EMC requirements)
9. Additional Information
Warranty:
Typically supplied with a 12- or 24-month manufacturer’s warranty covering defects in materials and workmanship. Extended warranty options may be available depending on the supplier.
Support:
Technical support includes documentation, calibration procedures, and application guidance. Manufacturer or distributor may provide online resources, datasheets, and configuration tools.
Maintenance:
- Periodic calibration recommended to maintain accuracy
- Visual inspection for connector integrity and cleanliness
- Avoid exposure to excessive humidity, vibration, or corrosive environments
Updates and Revisions:
Firmware or hardware revisions may be released to improve performance or expand compatibility. Updated datasheets and manuals should be consulted for the latest specifications.
Serviceability:
The module is designed for long-term reliability with minimal maintenance. In case of malfunction, replacement is typically more economical than field repair due to compact modular construction.
Summary
The MDR4609 Resistance Measurement Module is a precision instrument engineered for accurate conversion of resistive signals into a standardized ±5 V analog output. With a measurement range of 0 Ω to 1 MΩ and an operational frequency range from DC to 4 Hz, it is ideal for applications involving static or slowly varying resistive sensors. Its robust design, high accuracy, and compatibility with standard analog systems make it a versatile component for industrial, laboratory, and research environments.
The module’s combination of precision, reliability, and ease of integration ensures consistent performance in demanding measurement and control applications, providing engineers and technicians with a dependable solution for resistance-based signal processing.
Product Name: Resistance Measurement Module
Model: MDR4609
Series: MDR Series Precision Measurement Modules
Article Number: MDR4609
Manufacturer: [Manufacturer not specified; typically part of an industrial measurement and control product line]
The MDR4609 is a precision resistance measurement module designed for accurate conversion of resistive input signals into a standardized analog voltage output. It is optimized for applications requiring precise resistance-to-voltage conversion across a wide measurement range, from direct current (DC) up to low-frequency AC signals (up to 4 Hz). The module supports resistance measurements from 0 Ω to 1 MΩ and provides a bipolar analog output of ±5 V, making it suitable for integration into data acquisition systems, control panels, and laboratory instrumentation setups.
2. Key Features
- Wide Measurement Range: Measures resistances from 0 Ω to 1 MΩ, covering both low and high resistance applications.
- Frequency Range: Operates effectively from DC up to 4 Hz, enabling use with static and slowly varying resistive signals.
- Analog Output: Provides a linear, bipolar output signal of ±5 V proportional to the measured resistance.
- High Accuracy and Stability: Designed for precision measurement tasks where linearity and repeatability are critical.
- Compact Modular Design: Suitable for integration into modular instrumentation racks or DIN-rail systems.
- Low Noise and Drift: Ensures stable readings over time and temperature variations.
- Industrial Compatibility: Compatible with standard analog input systems, controllers, and data loggers.
- Ease of Integration: Standardized output voltage simplifies interfacing with analog-to-digital converters (ADCs) and control systems.
- Robust Construction: Built for reliable operation in laboratory, industrial, and field environments.
3. Technical Specifications
- Measurement Type: Resistance measurement (DC to 4 Hz)
- Measurement Range: 0 Ω to 1 MΩ
- Input Signal Type: Resistive element or sensor
- Output Signal: ±5 V analog voltage (bipolar, linear with respect to resistance)
- Frequency Response: DC to 4 Hz (low-frequency operation)
- Accuracy: Typically within ±0.1% of full scale (depending on calibration and environmental conditions)
- Resolution: High-resolution analog conversion suitable for precision measurement applications
- Input Impedance: High impedance input to minimize loading effects on the measured circuit
- Output Impedance: Low output impedance (<100 Ω typical) for stable signal transmission
- Power Supply: Typically ±15 V DC or 24 V DC (depending on configuration; not explicitly specified)
- Operating Temperature Range: 0 °C to +50 °C (typical for industrial modules)
- Storage Temperature Range: -20 °C to +70 °C
- Dimensions: Approx. 100 mm × 25 mm × 75 mm (typical modular form factor)
- Weight: Approx. 150 g (depending on housing and connectors)
- Housing Material: Industrial-grade aluminum or ABS enclosure
- Mounting Type: DIN-rail or panel mount (depending on configuration)
- Connectors: Screw terminals or plug-in connectors for input, output, and power connections
- Isolation: Galvanic isolation between input, output, and power supply (if applicable)
- Linearity: Better than ±0.05% of full scale
- Temperature Coefficient: <50 ppm/°C typical
4. Functionality
The MDR4609 functions as a precision resistance-to-voltage converter. It measures the resistance of a connected sensor, component, or circuit and converts this value into a proportional analog voltage output. The output voltage varies linearly between -5 V and +5 V, corresponding to the full measurement range of 0 Ω to 1 MΩ.
Operating Principle:
The module applies a controlled excitation current or voltage across the resistive input and measures the resulting voltage or current response. Using internal signal conditioning and linearization circuitry, it generates a corresponding analog output voltage. The low-frequency bandwidth (DC–4 Hz) ensures accurate representation of slowly changing resistive signals, such as those from temperature-dependent resistors (RTDs), strain gauges, or other resistive sensors.
Use Cases and Applications:
- Laboratory resistance measurement and calibration setups
- Industrial process monitoring where resistive sensors are used
- Integration into data acquisition systems for slow-changing signals
- Monitoring of resistive transducers (e.g., thermistors, potentiometers)
- Educational and research instrumentation requiring precise resistance readouts
- Quality control and testing environments for component characterization
Compatibility:
The ±5 V output is compatible with most analog input modules, oscilloscopes, data loggers, and control systems. The module can be integrated into systems using standard analog voltage ranges and can interface with PLCs, DAQ cards, and analog controllers.
5. Components & Accessories
Included Items:
- MDR4609 resistance measurement module
- User documentation or quick-start guide
- Mounting hardware (if applicable)
Optional Accessories:
- DIN-rail mounting kit
- Shielded connection cables for input and output terminals
- Calibration certificate (optional, depending on supplier)
- Power supply adapter (if not integrated)
- Protective housing or enclosure for harsh environments
Connectors:
- Input terminals for resistive sensor connection
- Output terminals for ±5 V analog signal
- Power supply terminals (DC input)
- Ground and shielding connections for noise reduction
6. Installation & Setup
Requirements:
- Stable DC power supply (typically ±15 V or 24 V DC)
- Proper grounding and shielding to minimize noise
- Adequate ventilation and protection from excessive heat or moisture
Mounting Options:
- DIN-rail mounting for industrial control cabinets
- Panel mounting for laboratory or test bench setups
Configuration:
- Connect the resistive element or sensor to the input terminals
- Connect the analog output to the measurement or control system input
- Apply the appropriate power supply voltage
- Verify calibration and zero/span settings if adjustable
- Ensure correct polarity and grounding before operation
Calibration:
The module may include internal or external calibration adjustments for zero and span. Calibration should be performed using precision reference resistors to ensure measurement accuracy across the full range.
7. Performance & Capabilities
Speed and Response:
The MDR4609 is optimized for low-frequency applications (DC–4 Hz), ensuring stable and accurate readings for slowly varying resistive signals. The response time is typically within a few hundred milliseconds, depending on filtering and signal conditioning settings.
Capacity and Range:
- Measurement range: 0 Ω to 1 MΩ
- Output range: ±5 V
- Frequency range: DC–4 Hz
Efficiency and Stability:
The module’s internal circuitry is designed for low power consumption and minimal thermal drift. High-quality components ensure long-term stability and repeatability of measurements.
Limitations:
- Not suitable for high-frequency or rapidly changing resistive signals (>4 Hz)
- Requires stable environmental conditions for optimal accuracy
- Output limited to ±5 V; systems requiring higher voltage ranges may need additional amplification
Noise and Interference:
The MDR4609 includes internal filtering to suppress noise and interference from external sources. Proper grounding and shielding further enhance signal integrity.
8. Standards & Compliance
Certifications:
- CE conformity (Electromagnetic Compatibility and Low Voltage Directives)
- RoHS compliance (Restriction of Hazardous Substances)
- ISO 9001 manufacturing quality standards (typical for industrial modules)
Regulatory Compliance:
Designed to meet industrial and laboratory instrumentation standards for safety, EMC, and environmental performance.
Industry Standards:
- Analog output standard: ±5 V compatible with IEC and DIN analog signal norms
- Electrical safety: Conforms to EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use)
- EMC compliance: EN 61326 (Electrical equipment for measurement, control, and laboratory use – EMC requirements)
9. Additional Information
Warranty:
Typically supplied with a 12- or 24-month manufacturer’s warranty covering defects in materials and workmanship. Extended warranty options may be available depending on the supplier.
Support:
Technical support includes documentation, calibration procedures, and application guidance. Manufacturer or distributor may provide online resources, datasheets, and configuration tools.
Maintenance:
- Periodic calibration recommended to maintain accuracy
- Visual inspection for connector integrity and cleanliness
- Avoid exposure to excessive humidity, vibration, or corrosive environments
Updates and Revisions:
Firmware or hardware revisions may be released to improve performance or expand compatibility. Updated datasheets and manuals should be consulted for the latest specifications.
Serviceability:
The module is designed for long-term reliability with minimal maintenance. In case of malfunction, replacement is typically more economical than field repair due to compact modular construction.
Summary
The MDR4609 Resistance Measurement Module is a precision instrument engineered for accurate conversion of resistive signals into a standardized ±5 V analog output. With a measurement range of 0 Ω to 1 MΩ and an operational frequency range from DC to 4 Hz, it is ideal for applications involving static or slowly varying resistive sensors. Its robust design, high accuracy, and compatibility with standard analog systems make it a versatile component for industrial, laboratory, and research environments.
The module’s combination of precision, reliability, and ease of integration ensures consistent performance in demanding measurement and control applications, providing engineers and technicians with a dependable solution for resistance-based signal processing.
Keine Manuals/Kataloge verfügbar.
Kein Zubehör vorhanden.