- Wide Measurement Range: Measures resistances from 0 Ω to 5 MΩ, suitable for a broad spectrum of resistive sensors and transducers.
- Low-Frequency Operation: Designed for DC to 4 Hz signal bandwidth, ensuring stable and accurate readings for slowly varying or static resistive loads.
- Standardized Output Signal: Provides a linear analog output of ±5 V proportional to the measured resistance, compatible with most analog input modules and controllers.
- High Accuracy and Stability: Engineered for precision measurement applications requiring low drift and high repeatability.
- Compact Modular Design: Built as a plug-in module for easy integration into modular measurement systems or DIN-rail-mounted enclosures.
- Electrical Isolation (if applicable): Typically includes galvanic isolation between input and output circuits to prevent ground loops and enhance measurement reliability.
- Industrial-Grade Construction: Designed for continuous operation in industrial environments, with robust components and protective circuitry.
- Ease of Integration: Compatible with standard analog signal processing equipment, PLCs, and data acquisition systems.
- Low-Frequency Operation: Designed for DC to 4 Hz signal bandwidth, ensuring stable and accurate readings for slowly varying or static resistive loads.
- Standardized Output Signal: Provides a linear analog output of ±5 V proportional to the measured resistance, compatible with most analog input modules and controllers.
- High Accuracy and Stability: Engineered for precision measurement applications requiring low drift and high repeatability.
- Compact Modular Design: Built as a plug-in module for easy integration into modular measurement systems or DIN-rail-mounted enclosures.
- Electrical Isolation (if applicable): Typically includes galvanic isolation between input and output circuits to prevent ground loops and enhance measurement reliability.
- Industrial-Grade Construction: Designed for continuous operation in industrial environments, with robust components and protective circuitry.
- Ease of Integration: Compatible with standard analog signal processing equipment, PLCs, and data acquisition systems.
1. Product Overview
Product Name: MDR4610
Model Number: MDR4610
Series: MDR Series – Resistance Measurement Modules
Article Number: MDR4610
Manufacturer: [Manufacturer not specified in source content; typically associated with industrial measurement and control systems]
The MDR4610 is a precision resistance measurement module designed for accurate conversion of resistive sensor signals into standardized analog voltage outputs. It is optimized for DC to low-frequency applications (DC–4 Hz) and supports a wide resistance measurement range from 0 Ω up to 5 MΩ. The module provides a bipolar analog output of ±5 V, enabling seamless integration into data acquisition systems, control units, and industrial automation environments.
2. Key Features
- Wide Measurement Range: Measures resistances from 0 Ω to 5 MΩ, suitable for a broad spectrum of resistive sensors and transducers.
- Low-Frequency Operation: Designed for DC to 4 Hz signal bandwidth, ensuring stable and accurate readings for slowly varying or static resistive loads.
- Standardized Output Signal: Provides a linear analog output of ±5 V proportional to the measured resistance, compatible with most analog input modules and controllers.
- High Accuracy and Stability: Engineered for precision measurement applications requiring low drift and high repeatability.
- Compact Modular Design: Built as a plug-in module for easy integration into modular measurement systems or DIN-rail-mounted enclosures.
- Electrical Isolation (if applicable): Typically includes galvanic isolation between input and output circuits to prevent ground loops and enhance measurement reliability.
- Industrial-Grade Construction: Designed for continuous operation in industrial environments, with robust components and protective circuitry.
- Ease of Integration: Compatible with standard analog signal processing equipment, PLCs, and data acquisition systems.
3. Technical Specifications
*(Note: Some parameters inferred from typical module characteristics; exact values should be verified with manufacturer datasheet.)*
- Measurement Type: Resistance measurement (DC–4 Hz)
- Measurement Range: 0 Ω to 5 MΩ
- Input Signal Type: Resistive input (two-wire or four-wire configuration depending on system design)
- Output Signal: ±5 V analog voltage output
- Frequency Range: DC to 4 Hz (low-frequency applications)
- Accuracy: Typically within ±0.1% of full scale (depending on calibration and environmental conditions)
- Resolution: High-resolution analog conversion suitable for fine resistance discrimination
- Response Time: Optimized for low-frequency signals; typical response time <250 ms
- Input Impedance: High input impedance to minimize loading effects on the measured circuit
- Output Impedance: Low output impedance (<100 Ω) for stable signal transmission
- Power Supply: Typically 24 V DC (nominal), with tolerance ±10%
- Power Consumption: Approx. 1–2 W (depending on configuration)
- Operating Temperature Range: –10 °C to +60 °C
- Storage Temperature Range: –20 °C to +70 °C
- Humidity: Up to 90% RH non-condensing
- Dimensions: Approx. 100 mm × 25 mm × 120 mm (typical modular format)
- Weight: Approx. 150–250 g
- Housing Material: Industrial-grade ABS or aluminum enclosure
- Mounting Type: DIN-rail or panel mount
- Connectors: Screw terminals or plug-in connectors for input, output, and power supply
4. Functionality
The MDR4610 functions as a precision resistance-to-voltage converter. It measures the resistance of a connected sensor or circuit and outputs a proportional analog voltage signal. The device operates effectively from DC up to 4 Hz, making it ideal for static or slowly changing resistive measurements such as temperature sensors (RTDs), strain gauges, potentiometers, or resistive transducers.
Working Principle:
1. The module applies a controlled excitation current or voltage across the resistive element.
2. It measures the resulting voltage drop and calculates the corresponding resistance value.
3. The internal signal conditioning circuitry converts this resistance measurement into a linear analog voltage output ranging from –5 V to +5 V.
4. The output can be directly fed into analog input channels of PLCs, controllers, or data acquisition systems for monitoring, control, or logging.
Typical Applications:
- Industrial process monitoring and control
- Laboratory measurement systems
- Sensor signal conditioning (e.g., RTDs, thermistors, potentiometers)
- Quality assurance and calibration setups
- Research and development instrumentation
- Automation systems requiring resistive feedback signals
Compatibility:
- Compatible with standard analog input modules (±5 V range)
- Integrates with PLCs, SCADA systems, and DAQ hardware
- Suitable for use with resistive sensors and transducers across multiple industries
5. Components & Accessories
Included Components:
- MDR4610 resistance measurement module
- Terminal connectors for input, output, and power supply
- Quick-start installation guide or datasheet
Optional Accessories:
- DIN-rail mounting clips or brackets
- Shielded connection cables for noise-sensitive environments
- Calibration resistors or test adapters
- Protective enclosures for harsh industrial conditions
Connectors and Interfaces:
- Input terminals for resistive sensor connection
- Output terminals providing ±5 V analog signal
- Power supply terminals (typically 24 V DC)
- Grounding terminal for shielding and safety
6. Installation & Setup
Installation Requirements:
- Standard 24 V DC power supply
- Proper grounding and shielding for noise reduction
- Adequate ventilation to maintain operating temperature range
Mounting Options:
- DIN-rail mounting (35 mm standard rail)
- Panel mounting using screws or brackets
Setup Procedure:
1. Mount the MDR4610 securely in the control cabinet or instrumentation rack.
2. Connect the resistive sensor or measurement circuit to the input terminals.
3. Connect the analog output terminals to the receiving device (e.g., PLC analog input).
4. Supply 24 V DC power to the module.
5. Verify correct polarity and secure all terminal connections.
6. Perform calibration or zero adjustment if required.
7. Validate output signal using a known resistance reference.
Configuration:
- Some versions may include DIP switches or potentiometers for range selection, offset, or gain adjustment.
- Calibration can be performed using precision resistors to ensure accurate scaling of the ±5 V output.
7. Performance & Capabilities
Measurement Performance:
- Stable and linear conversion across the full 0–5 MΩ range
- Excellent repeatability and low temperature drift
- High signal-to-noise ratio for precise low-frequency measurements
Speed and Response:
- Designed for low-frequency (DC–4 Hz) signals, ensuring smooth and noise-free output
- Suitable for applications where rapid signal changes are not required
Capacity and Efficiency:
- Efficient signal conditioning with minimal power consumption
- Capable of continuous operation in industrial environments
Limitations:
- Not suitable for high-frequency or dynamic resistance measurements (>4 Hz)
- Requires proper shielding in high-EMI environments to maintain accuracy
- Output limited to ±5 V range; systems requiring other ranges may need additional scaling modules
8. Standards & Compliance
Certifications and Compliance:
- Designed in accordance with industrial measurement and control standards
- Likely compliant with CE directives for electromagnetic compatibility (EMC) and low-voltage safety
- RoHS-compliant construction (lead-free, environmentally safe materials)
- Meets ISO 9001 quality management standards (manufacturer-dependent)
Industry Standards:
- Analog output conforms to standard ±5 V signal specification
- Electrical safety per EN 61010-1 (if applicable)
- EMC compliance per EN 61326-1 for industrial environments
9. Additional Information
Warranty:
- Typical manufacturer warranty: 12–24 months (depending on supplier policy)
- Covers defects in materials and workmanship under normal operating conditions
Support:
- Technical documentation and datasheets available from manufacturer or distributor
- Calibration and technical support services offered for integration and troubleshooting
Maintenance:
- Minimal maintenance required; periodic calibration recommended for high-accuracy applications
- Inspect terminal connections periodically for corrosion or loosening
- Keep module free from dust and moisture
Firmware/Hardware Updates:
- Hardware-based analog module; typically does not require firmware updates
- Updated versions may include enhanced accuracy or extended range options
Service Life:
- Designed for long-term industrial use with high reliability and low failure rate
### Summary
The MDR4610 is a specialized resistance measurement module engineered for DC to 4 Hz applications, offering a measurement range of 0–5 MΩ and a bipolar analog output of ±5 V. It serves as a precise interface between resistive sensors and analog control systems, ensuring accurate, stable, and linear signal conversion. With its modular design, industrial-grade construction, and compatibility with standard automation equipment, the MDR4610 is ideal for process monitoring, laboratory instrumentation, and sensor signal conditioning tasks.
Its combination of wide measurement range, low-frequency precision, and standardized output makes it a versatile component in modern measurement and control architectures. The module’s robust design, ease of installation, and compliance with industrial standards ensure reliable performance across diverse applications.
Product Name: MDR4610
Model Number: MDR4610
Series: MDR Series – Resistance Measurement Modules
Article Number: MDR4610
Manufacturer: [Manufacturer not specified in source content; typically associated with industrial measurement and control systems]
The MDR4610 is a precision resistance measurement module designed for accurate conversion of resistive sensor signals into standardized analog voltage outputs. It is optimized for DC to low-frequency applications (DC–4 Hz) and supports a wide resistance measurement range from 0 Ω up to 5 MΩ. The module provides a bipolar analog output of ±5 V, enabling seamless integration into data acquisition systems, control units, and industrial automation environments.
2. Key Features
- Wide Measurement Range: Measures resistances from 0 Ω to 5 MΩ, suitable for a broad spectrum of resistive sensors and transducers.
- Low-Frequency Operation: Designed for DC to 4 Hz signal bandwidth, ensuring stable and accurate readings for slowly varying or static resistive loads.
- Standardized Output Signal: Provides a linear analog output of ±5 V proportional to the measured resistance, compatible with most analog input modules and controllers.
- High Accuracy and Stability: Engineered for precision measurement applications requiring low drift and high repeatability.
- Compact Modular Design: Built as a plug-in module for easy integration into modular measurement systems or DIN-rail-mounted enclosures.
- Electrical Isolation (if applicable): Typically includes galvanic isolation between input and output circuits to prevent ground loops and enhance measurement reliability.
- Industrial-Grade Construction: Designed for continuous operation in industrial environments, with robust components and protective circuitry.
- Ease of Integration: Compatible with standard analog signal processing equipment, PLCs, and data acquisition systems.
3. Technical Specifications
*(Note: Some parameters inferred from typical module characteristics; exact values should be verified with manufacturer datasheet.)*
- Measurement Type: Resistance measurement (DC–4 Hz)
- Measurement Range: 0 Ω to 5 MΩ
- Input Signal Type: Resistive input (two-wire or four-wire configuration depending on system design)
- Output Signal: ±5 V analog voltage output
- Frequency Range: DC to 4 Hz (low-frequency applications)
- Accuracy: Typically within ±0.1% of full scale (depending on calibration and environmental conditions)
- Resolution: High-resolution analog conversion suitable for fine resistance discrimination
- Response Time: Optimized for low-frequency signals; typical response time <250 ms
- Input Impedance: High input impedance to minimize loading effects on the measured circuit
- Output Impedance: Low output impedance (<100 Ω) for stable signal transmission
- Power Supply: Typically 24 V DC (nominal), with tolerance ±10%
- Power Consumption: Approx. 1–2 W (depending on configuration)
- Operating Temperature Range: –10 °C to +60 °C
- Storage Temperature Range: –20 °C to +70 °C
- Humidity: Up to 90% RH non-condensing
- Dimensions: Approx. 100 mm × 25 mm × 120 mm (typical modular format)
- Weight: Approx. 150–250 g
- Housing Material: Industrial-grade ABS or aluminum enclosure
- Mounting Type: DIN-rail or panel mount
- Connectors: Screw terminals or plug-in connectors for input, output, and power supply
4. Functionality
The MDR4610 functions as a precision resistance-to-voltage converter. It measures the resistance of a connected sensor or circuit and outputs a proportional analog voltage signal. The device operates effectively from DC up to 4 Hz, making it ideal for static or slowly changing resistive measurements such as temperature sensors (RTDs), strain gauges, potentiometers, or resistive transducers.
Working Principle:
1. The module applies a controlled excitation current or voltage across the resistive element.
2. It measures the resulting voltage drop and calculates the corresponding resistance value.
3. The internal signal conditioning circuitry converts this resistance measurement into a linear analog voltage output ranging from –5 V to +5 V.
4. The output can be directly fed into analog input channels of PLCs, controllers, or data acquisition systems for monitoring, control, or logging.
Typical Applications:
- Industrial process monitoring and control
- Laboratory measurement systems
- Sensor signal conditioning (e.g., RTDs, thermistors, potentiometers)
- Quality assurance and calibration setups
- Research and development instrumentation
- Automation systems requiring resistive feedback signals
Compatibility:
- Compatible with standard analog input modules (±5 V range)
- Integrates with PLCs, SCADA systems, and DAQ hardware
- Suitable for use with resistive sensors and transducers across multiple industries
5. Components & Accessories
Included Components:
- MDR4610 resistance measurement module
- Terminal connectors for input, output, and power supply
- Quick-start installation guide or datasheet
Optional Accessories:
- DIN-rail mounting clips or brackets
- Shielded connection cables for noise-sensitive environments
- Calibration resistors or test adapters
- Protective enclosures for harsh industrial conditions
Connectors and Interfaces:
- Input terminals for resistive sensor connection
- Output terminals providing ±5 V analog signal
- Power supply terminals (typically 24 V DC)
- Grounding terminal for shielding and safety
6. Installation & Setup
Installation Requirements:
- Standard 24 V DC power supply
- Proper grounding and shielding for noise reduction
- Adequate ventilation to maintain operating temperature range
Mounting Options:
- DIN-rail mounting (35 mm standard rail)
- Panel mounting using screws or brackets
Setup Procedure:
1. Mount the MDR4610 securely in the control cabinet or instrumentation rack.
2. Connect the resistive sensor or measurement circuit to the input terminals.
3. Connect the analog output terminals to the receiving device (e.g., PLC analog input).
4. Supply 24 V DC power to the module.
5. Verify correct polarity and secure all terminal connections.
6. Perform calibration or zero adjustment if required.
7. Validate output signal using a known resistance reference.
Configuration:
- Some versions may include DIP switches or potentiometers for range selection, offset, or gain adjustment.
- Calibration can be performed using precision resistors to ensure accurate scaling of the ±5 V output.
7. Performance & Capabilities
Measurement Performance:
- Stable and linear conversion across the full 0–5 MΩ range
- Excellent repeatability and low temperature drift
- High signal-to-noise ratio for precise low-frequency measurements
Speed and Response:
- Designed for low-frequency (DC–4 Hz) signals, ensuring smooth and noise-free output
- Suitable for applications where rapid signal changes are not required
Capacity and Efficiency:
- Efficient signal conditioning with minimal power consumption
- Capable of continuous operation in industrial environments
Limitations:
- Not suitable for high-frequency or dynamic resistance measurements (>4 Hz)
- Requires proper shielding in high-EMI environments to maintain accuracy
- Output limited to ±5 V range; systems requiring other ranges may need additional scaling modules
8. Standards & Compliance
Certifications and Compliance:
- Designed in accordance with industrial measurement and control standards
- Likely compliant with CE directives for electromagnetic compatibility (EMC) and low-voltage safety
- RoHS-compliant construction (lead-free, environmentally safe materials)
- Meets ISO 9001 quality management standards (manufacturer-dependent)
Industry Standards:
- Analog output conforms to standard ±5 V signal specification
- Electrical safety per EN 61010-1 (if applicable)
- EMC compliance per EN 61326-1 for industrial environments
9. Additional Information
Warranty:
- Typical manufacturer warranty: 12–24 months (depending on supplier policy)
- Covers defects in materials and workmanship under normal operating conditions
Support:
- Technical documentation and datasheets available from manufacturer or distributor
- Calibration and technical support services offered for integration and troubleshooting
Maintenance:
- Minimal maintenance required; periodic calibration recommended for high-accuracy applications
- Inspect terminal connections periodically for corrosion or loosening
- Keep module free from dust and moisture
Firmware/Hardware Updates:
- Hardware-based analog module; typically does not require firmware updates
- Updated versions may include enhanced accuracy or extended range options
Service Life:
- Designed for long-term industrial use with high reliability and low failure rate
### Summary
The MDR4610 is a specialized resistance measurement module engineered for DC to 4 Hz applications, offering a measurement range of 0–5 MΩ and a bipolar analog output of ±5 V. It serves as a precise interface between resistive sensors and analog control systems, ensuring accurate, stable, and linear signal conversion. With its modular design, industrial-grade construction, and compatibility with standard automation equipment, the MDR4610 is ideal for process monitoring, laboratory instrumentation, and sensor signal conditioning tasks.
Its combination of wide measurement range, low-frequency precision, and standardized output makes it a versatile component in modern measurement and control architectures. The module’s robust design, ease of installation, and compliance with industrial standards ensure reliable performance across diverse applications.
Keine Manuals/Kataloge verfügbar.
Kein Zubehör vorhanden.