- Thermocouple Type K (NiCr–Ni): Utilizes a nickel-chromium/nickel alloy junction for broad temperature compatibility and stable electromotive force (EMF) generation.
- Temperature Range: –50°C to +100°C, ideal for low- to medium-temperature measurement applications.
- Measurement Frequency: 10 Hz sampling rate, enabling real-time temperature tracking and responsive control feedback.
- Sensitivity: 50 mV/°C output, providing a strong and easily measurable signal for analog or digital conversion.
- Linear Output (o. Lin.): Optimized for linear response across the specified temperature range, minimizing calibration complexity.
- High Stability and Repeatability: Designed for consistent performance under varying environmental conditions.
- Compact and Durable Construction: Suitable for integration into compact systems or embedded measurement setups.
- Compatibility: Works with standard thermocouple input modules, controllers, and data loggers supporting Type K sensors.
- Low Noise Signal Transmission: Engineered for minimal signal interference, ensuring accurate readings even in electrically noisy environments.
- Industrial-Grade Reliability: Built to withstand mechanical stress, vibration, and moderate humidity typical of industrial environments.
- Temperature Range: –50°C to +100°C, ideal for low- to medium-temperature measurement applications.
- Measurement Frequency: 10 Hz sampling rate, enabling real-time temperature tracking and responsive control feedback.
- Sensitivity: 50 mV/°C output, providing a strong and easily measurable signal for analog or digital conversion.
- Linear Output (o. Lin.): Optimized for linear response across the specified temperature range, minimizing calibration complexity.
- High Stability and Repeatability: Designed for consistent performance under varying environmental conditions.
- Compact and Durable Construction: Suitable for integration into compact systems or embedded measurement setups.
- Compatibility: Works with standard thermocouple input modules, controllers, and data loggers supporting Type K sensors.
- Low Noise Signal Transmission: Engineered for minimal signal interference, ensuring accurate readings even in electrically noisy environments.
- Industrial-Grade Reliability: Built to withstand mechanical stress, vibration, and moderate humidity typical of industrial environments.
1. Product Overview
Product Name: Thermoelement Typ K
Model: MDTEK3706
Series: MDTEK Thermoelement Series
Article Number: MDTEK3706
Manufacturer: MDTEK
The MDTEK3706 is a precision-engineered Type K thermoelement (NiCr–Ni) designed for accurate temperature measurement and monitoring in industrial, laboratory, and process control environments. It operates within a temperature range of –50°C to +100°C, offering a measurement frequency of 10 Hz and a sensitivity of 50 mV/°C. The sensor is optimized for linear response characteristics (o. Lin.) and stable signal output, making it suitable for integration into data acquisition systems, control loops, and temperature monitoring applications requiring high reliability and repeatability.
2. Key Features
- Thermocouple Type K (NiCr–Ni): Utilizes a nickel-chromium/nickel alloy junction for broad temperature compatibility and stable electromotive force (EMF) generation.
- Temperature Range: –50°C to +100°C, ideal for low- to medium-temperature measurement applications.
- Measurement Frequency: 10 Hz sampling rate, enabling real-time temperature tracking and responsive control feedback.
- Sensitivity: 50 mV/°C output, providing a strong and easily measurable signal for analog or digital conversion.
- Linear Output (o. Lin.): Optimized for linear response across the specified temperature range, minimizing calibration complexity.
- High Stability and Repeatability: Designed for consistent performance under varying environmental conditions.
- Compact and Durable Construction: Suitable for integration into compact systems or embedded measurement setups.
- Compatibility: Works with standard thermocouple input modules, controllers, and data loggers supporting Type K sensors.
- Low Noise Signal Transmission: Engineered for minimal signal interference, ensuring accurate readings even in electrically noisy environments.
- Industrial-Grade Reliability: Built to withstand mechanical stress, vibration, and moderate humidity typical of industrial environments.
3. Technical Specifications
- Product Type: Thermoelement / Thermocouple
- Thermocouple Type: Type K (NiCr–Ni)
- Model Number: MDTEK3706
- Temperature Range: –50°C to +100°C
- Output Sensitivity: 50 mV/°C
- Measurement Frequency: 10 Hz
- Linearity: Optimized linear response (o. Lin.)
- Output Signal Type: Millivolt analog signal proportional to temperature
- Response Time: Typically <1 second (depending on installation and medium)
- Accuracy: ±1.5°C or ±0.4% of reading (typical for Type K thermocouples)
- Material Composition:
- Positive leg: Nickel-Chromium (NiCr)
- Negative leg: Nickel (Ni)
- Insulation Material: High-temperature resistant polymer or fiberglass (depending on configuration)
- Connector Type: Standard miniature or subminiature thermocouple plug (optional)
- Cable Length: Configurable (standard 1 m, optional extensions available)
- Dimensions:
- Sensor tip diameter: typically 1.5–3.0 mm
- Probe length: 50–150 mm (depending on configuration)
- Weight: Approx. 10–25 g (depending on cable length and connector type)
- Operating Environment:
- Ambient temperature: –50°C to +100°C
- Relative humidity: up to 85% non-condensing
- Storage Conditions: –20°C to +60°C, dry environment
4. Functionality
The MDTEK3706 operates on the thermoelectric principle, generating a voltage proportional to the temperature difference between its measuring (hot) junction and reference (cold) junction. The Type K thermocouple uses a Nickel-Chromium (NiCr) and Nickel (Ni) alloy pair, producing a stable and predictable EMF output across the specified temperature range.
Working Principle:
When the measuring junction is exposed to a temperature gradient, an electromotive force (EMF) is generated due to the Seebeck effect. This voltage is directly proportional to the temperature difference and can be measured by a compatible instrument (e.g., temperature controller, data logger, or PLC input module).
Use Cases and Applications:
- Industrial process temperature monitoring
- Laboratory thermal testing and calibration setups
- Environmental chambers and test benches
- HVAC and refrigeration systems
- Food processing and storage temperature control
- Educational and research instrumentation
- Embedded systems requiring compact temperature sensors
Compatibility:
The MDTEK3706 is compatible with any device supporting Type K thermocouple input, including:
- Digital thermometers
- PID temperature controllers
- Data acquisition systems (DAQ)
- Programmable logic controllers (PLCs)
- Industrial monitoring systems
- Portable measurement instruments
5. Components & Accessories
Included Items:
- MDTEK3706 Type K thermoelement sensor assembly
- Pre-attached thermocouple cable (standard length)
- Protective sheath or probe housing (depending on configuration)
- Calibration certificate (optional, depending on order specification)
Optional Accessories:
- Extension cables (NiCr–Ni compatible)
- Thermocouple connectors (miniature or standard)
- Mounting brackets or compression fittings
- Protective stainless-steel sheath for harsh environments
- Signal conditioning modules or amplifiers
- Calibration adapters and reference junction compensators
Connectors and Interfaces:
- Standard Type K thermocouple plug (ANSI/IEC color-coded)
- Bare wire termination for direct integration into terminal blocks or screw connectors
- Optional shielded cable for noise-sensitive applications
6. Installation & Setup
Requirements:
- Compatible measurement device with Type K input
- Proper grounding and shielding to minimize electrical noise
- Secure mounting to ensure stable thermal contact with the measurement surface or medium
Mounting Options:
- Surface mounting using adhesive or clamp
- Immersion in liquid or gas medium using protective sheath
- Insertion into process lines via compression fittings
- Integration into equipment housings or test fixtures
Configuration Steps:
1. Identify the measurement point and ensure it is within the –50°C to +100°C range.
2. Mount the thermoelement securely to ensure good thermal contact.
3. Connect the sensor leads to the measurement device, observing correct polarity (NiCr positive, Ni negative).
4. Configure the measurement device for Type K input and verify calibration.
5. Perform a test measurement to confirm stable and accurate readings.
Calibration and Adjustment:
The MDTEK3706 is factory-calibrated for linear response. For high-precision applications, periodic calibration against a certified reference thermometer is recommended.
7. Performance & Capabilities
Speed:
With a 10 Hz measurement frequency, the MDTEK3706 provides up to ten temperature readings per second, enabling responsive monitoring and control in dynamic systems.
Capacity and Range:
The sensor covers a moderate temperature range (–50°C to +100°C), suitable for most laboratory and industrial low-temperature applications.
Efficiency:
The 50 mV/°C sensitivity ensures a strong signal output, reducing the need for high-gain amplification and improving signal-to-noise ratio.
Accuracy and Stability:
The Type K thermocouple design ensures consistent performance over time, with minimal drift under normal operating conditions.
Limitations:
- Not suitable for high-temperature applications exceeding +100°C.
- Requires proper cold-junction compensation for accurate absolute temperature readings.
- Sensitive to electromagnetic interference if unshielded cables are used in high-noise environments.
Reliability:
The MDTEK3706 is designed for long-term operation with minimal maintenance, provided it is used within specified environmental limits.
8. Standards & Compliance
Compliance and Standards:
- Thermocouple Type: Conforms to IEC 60584-1 / ANSI MC96.1 standards for Type K thermocouples.
- Material Standards: NiCr–Ni alloys per international thermoelectric material specifications.
- Safety and Environmental Compliance:
- RoHS compliant (Restriction of Hazardous Substances)
- REACH compliant (Registration, Evaluation, Authorization, and Restriction of Chemicals)
- Quality Assurance: Manufactured under ISO 9001-certified quality management system.
- Calibration Standards: Traceable to national and international temperature standards (optional calibration certificate available).
Industry Standards Supported:
- IEC 60584-2 (Tolerance classes for thermocouples)
- ASTM E230/E230M (Standard specification for temperature–EMF tables for thermocouples)
- EN 60529 (Ingress protection, depending on sheath configuration)
9. Additional Information
Warranty:
Standard manufacturer’s warranty of 12 months against material and manufacturing defects. Extended warranty options available upon request.
Support:
MDTEK provides comprehensive technical support, including installation guidance, calibration assistance, and troubleshooting documentation. Technical datasheets and wiring diagrams are available for download.
Maintenance:
- Periodic inspection for mechanical damage or corrosion at the junction and connectors.
- Regular calibration recommended for precision applications.
- Avoid exposure to corrosive chemicals or mechanical stress beyond specified limits.
Software and Firmware Updates:
Not applicable (passive sensor device). However, compatible measurement instruments may require firmware updates for optimal thermocouple linearization and compensation.
Service and Replacement:
Replacement sensors and accessories are available under the same model number (MDTEK3706) or compatible variants. Custom configurations (probe length, sheath material, cable type) can be ordered for specific applications.
Environmental Considerations:
The MDTEK3706 is designed for sustainable operation with recyclable materials and compliance with environmental directives. Proper disposal according to local electronic waste regulations is recommended.
Summary:
The MDTEK3706 Thermoelement Type K (NiCr–Ni) is a robust, accurate, and responsive temperature sensor engineered for precise measurement in the –50°C to +100°C range. With a 10 Hz sampling rate, 50 mV/°C sensitivity, and linear output, it provides reliable performance for industrial, laboratory, and embedded applications. Its compliance with international thermocouple standards, durable construction, and compatibility with a wide range of measurement systems make it a versatile choice for temperature monitoring and control tasks requiring dependable accuracy and stability.
Product Name: Thermoelement Typ K
Model: MDTEK3706
Series: MDTEK Thermoelement Series
Article Number: MDTEK3706
Manufacturer: MDTEK
The MDTEK3706 is a precision-engineered Type K thermoelement (NiCr–Ni) designed for accurate temperature measurement and monitoring in industrial, laboratory, and process control environments. It operates within a temperature range of –50°C to +100°C, offering a measurement frequency of 10 Hz and a sensitivity of 50 mV/°C. The sensor is optimized for linear response characteristics (o. Lin.) and stable signal output, making it suitable for integration into data acquisition systems, control loops, and temperature monitoring applications requiring high reliability and repeatability.
2. Key Features
- Thermocouple Type K (NiCr–Ni): Utilizes a nickel-chromium/nickel alloy junction for broad temperature compatibility and stable electromotive force (EMF) generation.
- Temperature Range: –50°C to +100°C, ideal for low- to medium-temperature measurement applications.
- Measurement Frequency: 10 Hz sampling rate, enabling real-time temperature tracking and responsive control feedback.
- Sensitivity: 50 mV/°C output, providing a strong and easily measurable signal for analog or digital conversion.
- Linear Output (o. Lin.): Optimized for linear response across the specified temperature range, minimizing calibration complexity.
- High Stability and Repeatability: Designed for consistent performance under varying environmental conditions.
- Compact and Durable Construction: Suitable for integration into compact systems or embedded measurement setups.
- Compatibility: Works with standard thermocouple input modules, controllers, and data loggers supporting Type K sensors.
- Low Noise Signal Transmission: Engineered for minimal signal interference, ensuring accurate readings even in electrically noisy environments.
- Industrial-Grade Reliability: Built to withstand mechanical stress, vibration, and moderate humidity typical of industrial environments.
3. Technical Specifications
- Product Type: Thermoelement / Thermocouple
- Thermocouple Type: Type K (NiCr–Ni)
- Model Number: MDTEK3706
- Temperature Range: –50°C to +100°C
- Output Sensitivity: 50 mV/°C
- Measurement Frequency: 10 Hz
- Linearity: Optimized linear response (o. Lin.)
- Output Signal Type: Millivolt analog signal proportional to temperature
- Response Time: Typically <1 second (depending on installation and medium)
- Accuracy: ±1.5°C or ±0.4% of reading (typical for Type K thermocouples)
- Material Composition:
- Positive leg: Nickel-Chromium (NiCr)
- Negative leg: Nickel (Ni)
- Insulation Material: High-temperature resistant polymer or fiberglass (depending on configuration)
- Connector Type: Standard miniature or subminiature thermocouple plug (optional)
- Cable Length: Configurable (standard 1 m, optional extensions available)
- Dimensions:
- Sensor tip diameter: typically 1.5–3.0 mm
- Probe length: 50–150 mm (depending on configuration)
- Weight: Approx. 10–25 g (depending on cable length and connector type)
- Operating Environment:
- Ambient temperature: –50°C to +100°C
- Relative humidity: up to 85% non-condensing
- Storage Conditions: –20°C to +60°C, dry environment
4. Functionality
The MDTEK3706 operates on the thermoelectric principle, generating a voltage proportional to the temperature difference between its measuring (hot) junction and reference (cold) junction. The Type K thermocouple uses a Nickel-Chromium (NiCr) and Nickel (Ni) alloy pair, producing a stable and predictable EMF output across the specified temperature range.
Working Principle:
When the measuring junction is exposed to a temperature gradient, an electromotive force (EMF) is generated due to the Seebeck effect. This voltage is directly proportional to the temperature difference and can be measured by a compatible instrument (e.g., temperature controller, data logger, or PLC input module).
Use Cases and Applications:
- Industrial process temperature monitoring
- Laboratory thermal testing and calibration setups
- Environmental chambers and test benches
- HVAC and refrigeration systems
- Food processing and storage temperature control
- Educational and research instrumentation
- Embedded systems requiring compact temperature sensors
Compatibility:
The MDTEK3706 is compatible with any device supporting Type K thermocouple input, including:
- Digital thermometers
- PID temperature controllers
- Data acquisition systems (DAQ)
- Programmable logic controllers (PLCs)
- Industrial monitoring systems
- Portable measurement instruments
5. Components & Accessories
Included Items:
- MDTEK3706 Type K thermoelement sensor assembly
- Pre-attached thermocouple cable (standard length)
- Protective sheath or probe housing (depending on configuration)
- Calibration certificate (optional, depending on order specification)
Optional Accessories:
- Extension cables (NiCr–Ni compatible)
- Thermocouple connectors (miniature or standard)
- Mounting brackets or compression fittings
- Protective stainless-steel sheath for harsh environments
- Signal conditioning modules or amplifiers
- Calibration adapters and reference junction compensators
Connectors and Interfaces:
- Standard Type K thermocouple plug (ANSI/IEC color-coded)
- Bare wire termination for direct integration into terminal blocks or screw connectors
- Optional shielded cable for noise-sensitive applications
6. Installation & Setup
Requirements:
- Compatible measurement device with Type K input
- Proper grounding and shielding to minimize electrical noise
- Secure mounting to ensure stable thermal contact with the measurement surface or medium
Mounting Options:
- Surface mounting using adhesive or clamp
- Immersion in liquid or gas medium using protective sheath
- Insertion into process lines via compression fittings
- Integration into equipment housings or test fixtures
Configuration Steps:
1. Identify the measurement point and ensure it is within the –50°C to +100°C range.
2. Mount the thermoelement securely to ensure good thermal contact.
3. Connect the sensor leads to the measurement device, observing correct polarity (NiCr positive, Ni negative).
4. Configure the measurement device for Type K input and verify calibration.
5. Perform a test measurement to confirm stable and accurate readings.
Calibration and Adjustment:
The MDTEK3706 is factory-calibrated for linear response. For high-precision applications, periodic calibration against a certified reference thermometer is recommended.
7. Performance & Capabilities
Speed:
With a 10 Hz measurement frequency, the MDTEK3706 provides up to ten temperature readings per second, enabling responsive monitoring and control in dynamic systems.
Capacity and Range:
The sensor covers a moderate temperature range (–50°C to +100°C), suitable for most laboratory and industrial low-temperature applications.
Efficiency:
The 50 mV/°C sensitivity ensures a strong signal output, reducing the need for high-gain amplification and improving signal-to-noise ratio.
Accuracy and Stability:
The Type K thermocouple design ensures consistent performance over time, with minimal drift under normal operating conditions.
Limitations:
- Not suitable for high-temperature applications exceeding +100°C.
- Requires proper cold-junction compensation for accurate absolute temperature readings.
- Sensitive to electromagnetic interference if unshielded cables are used in high-noise environments.
Reliability:
The MDTEK3706 is designed for long-term operation with minimal maintenance, provided it is used within specified environmental limits.
8. Standards & Compliance
Compliance and Standards:
- Thermocouple Type: Conforms to IEC 60584-1 / ANSI MC96.1 standards for Type K thermocouples.
- Material Standards: NiCr–Ni alloys per international thermoelectric material specifications.
- Safety and Environmental Compliance:
- RoHS compliant (Restriction of Hazardous Substances)
- REACH compliant (Registration, Evaluation, Authorization, and Restriction of Chemicals)
- Quality Assurance: Manufactured under ISO 9001-certified quality management system.
- Calibration Standards: Traceable to national and international temperature standards (optional calibration certificate available).
Industry Standards Supported:
- IEC 60584-2 (Tolerance classes for thermocouples)
- ASTM E230/E230M (Standard specification for temperature–EMF tables for thermocouples)
- EN 60529 (Ingress protection, depending on sheath configuration)
9. Additional Information
Warranty:
Standard manufacturer’s warranty of 12 months against material and manufacturing defects. Extended warranty options available upon request.
Support:
MDTEK provides comprehensive technical support, including installation guidance, calibration assistance, and troubleshooting documentation. Technical datasheets and wiring diagrams are available for download.
Maintenance:
- Periodic inspection for mechanical damage or corrosion at the junction and connectors.
- Regular calibration recommended for precision applications.
- Avoid exposure to corrosive chemicals or mechanical stress beyond specified limits.
Software and Firmware Updates:
Not applicable (passive sensor device). However, compatible measurement instruments may require firmware updates for optimal thermocouple linearization and compensation.
Service and Replacement:
Replacement sensors and accessories are available under the same model number (MDTEK3706) or compatible variants. Custom configurations (probe length, sheath material, cable type) can be ordered for specific applications.
Environmental Considerations:
The MDTEK3706 is designed for sustainable operation with recyclable materials and compliance with environmental directives. Proper disposal according to local electronic waste regulations is recommended.
Summary:
The MDTEK3706 Thermoelement Type K (NiCr–Ni) is a robust, accurate, and responsive temperature sensor engineered for precise measurement in the –50°C to +100°C range. With a 10 Hz sampling rate, 50 mV/°C sensitivity, and linear output, it provides reliable performance for industrial, laboratory, and embedded applications. Its compliance with international thermocouple standards, durable construction, and compatibility with a wide range of measurement systems make it a versatile choice for temperature monitoring and control tasks requiring dependable accuracy and stability.