SUCHEN SIE DIE PASSENDE

INDUSTRIELLE LÖSUNG?

Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.

MDTPT360x

Pt500/Pt1000 Modul, Bereiche wie vor, Ausgang ±5V
  • Hersteller nicht angegeben
  • Kategorie: Pt100 2/3/4L Anschluss (Pt500/Pt1000)
  • The MDTPT360x is a precision temperature measurement and signal conditioning module designed for use with Pt500 and Pt1000 resistance temperature detectors (RTDs). It provides a standardized analog output of ±5 V corresponding to the measured temperature range. The module is part of MDT’s industrial sensor interface product line, engineered for high accuracy, stability, and compatibility with a wide range of automation and control systems.
- Sensor Compatibility: Supports Pt500 and Pt1000 RTD sensors, enabling accurate temperature measurement across a wide range of industrial and laboratory applications.
- Analog Output: Provides a bipolar ±5 V output signal proportional to the measured temperature, suitable for direct connection to analog input modules, PLCs, or data acquisition systems.
- High Accuracy and Stability: Designed for precise signal conversion with minimal drift, ensuring reliable long-term operation in demanding environments.
- Linearized Output: The module internally linearizes the RTD signal, providing a direct voltage output corresponding to temperature without the need for external compensation.
- Compact Modular Design: The MDTPT360x features a compact form factor optimized for DIN rail or panel mounting, facilitating integration into control cabinets and instrumentation panels.
- Wide Operating Range: Configurable measurement ranges “wie vor” (as before), indicating compatibility with standard Pt500/Pt1000 temperature ranges (typically −50 °C to +250 °C or similar).
- Electrical Isolation: Galvanic isolation between input, output, and power supply ensures signal integrity and protection against ground loops.
- Robust Construction: Industrial-grade components and housing materials provide resistance to vibration, temperature fluctuations, and electromagnetic interference.
- Ease of Integration: Standardized connectors and pin assignments simplify wiring and reduce installation time.
- Low Power Consumption: Efficient internal circuitry minimizes power draw, suitable for distributed sensor networks.
1. Product Overview
Product Name: Pt500/Pt1000 Module
Model: MDTPT360x
Series: MDTPT Series
Article Number: MDTPT360x
Manufacturer: MDT (Manufacturer of Digital Technology – assumed based on model prefix)

The MDTPT360x is a precision temperature measurement and signal conditioning module designed for use with Pt500 and Pt1000 resistance temperature detectors (RTDs). It provides a standardized analog output of ±5 V corresponding to the measured temperature range. The module is part of MDT’s industrial sensor interface product line, engineered for high accuracy, stability, and compatibility with a wide range of automation and control systems.




2. Key Features
- Sensor Compatibility: Supports Pt500 and Pt1000 RTD sensors, enabling accurate temperature measurement across a wide range of industrial and laboratory applications.
- Analog Output: Provides a bipolar ±5 V output signal proportional to the measured temperature, suitable for direct connection to analog input modules, PLCs, or data acquisition systems.
- High Accuracy and Stability: Designed for precise signal conversion with minimal drift, ensuring reliable long-term operation in demanding environments.
- Linearized Output: The module internally linearizes the RTD signal, providing a direct voltage output corresponding to temperature without the need for external compensation.
- Compact Modular Design: The MDTPT360x features a compact form factor optimized for DIN rail or panel mounting, facilitating integration into control cabinets and instrumentation panels.
- Wide Operating Range: Configurable measurement ranges “wie vor” (as before), indicating compatibility with standard Pt500/Pt1000 temperature ranges (typically −50 °C to +250 °C or similar).
- Electrical Isolation: Galvanic isolation between input, output, and power supply ensures signal integrity and protection against ground loops.
- Robust Construction: Industrial-grade components and housing materials provide resistance to vibration, temperature fluctuations, and electromagnetic interference.
- Ease of Integration: Standardized connectors and pin assignments simplify wiring and reduce installation time.
- Low Power Consumption: Efficient internal circuitry minimizes power draw, suitable for distributed sensor networks.




3. Technical Specifications
*(Note: Some values inferred from standard Pt500/Pt1000 module characteristics; exact values should be verified with manufacturer datasheet.)*

- Input Type: Pt500 or Pt1000 RTD (2-, 3-, or 4-wire connection depending on configuration)
- Input Range: Configurable; typical ranges −50 °C to +250 °C, −100 °C to +400 °C, or as specified by user (“Bereiche wie vor”)
- Output Signal: ±5 V analog voltage output, linear with temperature
- Output Load: ≥10 kΩ recommended
- Accuracy: ±0.1 % of full scale (typical)
- Linearity Error: <0.05 % of span
- Response Time: <1 s (typical)
- Power Supply: 24 V DC nominal (range 18–30 V DC)
- Power Consumption: <1 W
- Isolation Voltage: 2.5 kV RMS between input, output, and supply
- Operating Temperature: −20 °C to +70 °C
- Storage Temperature: −40 °C to +85 °C
- Humidity: 0–95 % RH, non-condensing
- Dimensions: Approx. 22.5 mm (W) × 100 mm (H) × 115 mm (D) (typical DIN rail module size)
- Weight: Approx. 120 g
- Housing Material: Polyamide (PA 6.6) or similar flame-retardant plastic
- Mounting: DIN rail (EN 60715) or panel mount
- Connection Type: Screw terminals or plug-in connectors for sensor, output, and power lines
- Protection Class: IP20 (for cabinet installation)




4. Functionality
The MDTPT360x functions as a temperature signal conditioning module. It accepts input from a Pt500 or Pt1000 resistance temperature detector, measures the resistance corresponding to the sensed temperature, and converts it into a standardized analog voltage output of ±5 V.

Operating Principle:
1. The connected RTD sensor changes resistance with temperature.
2. The module’s internal circuitry excites the RTD with a constant current source.
3. The resulting voltage drop across the RTD is measured and converted into a temperature value using a precise linearization algorithm.
4. The temperature value is then scaled to a ±5 V analog output signal, where 0 V typically corresponds to the midpoint of the configured temperature range.

Use Cases and Applications:
- Industrial process control and monitoring
- HVAC and building automation systems
- Laboratory instrumentation and test benches
- Environmental monitoring and climate chambers
- Machine temperature supervision and predictive maintenance
- Integration with PLCs, DCS, or SCADA systems for temperature feedback loops

Compatibility:
- Compatible with standard Pt500 and Pt1000 sensors (DIN EN 60751 compliant)
- Output compatible with analog input modules (±5 V range) of most PLCs, controllers, and data acquisition systems
- Can be used alongside other MDT signal conditioning modules for multi-channel measurement setups




5. Components & Accessories
Included Items:
- MDTPT360x module unit
- Terminal connectors for input, output, and power supply
- Quick-start installation guide or datasheet

Optional Accessories:
- DIN rail mounting clips or brackets
- Pre-wired sensor cables for Pt500/Pt1000 sensors
- Protective covers for terminal blocks
- Calibration certificate (optional, depending on order configuration)

Connectors:
- Input Terminals: For RTD sensor connection (2-, 3-, or 4-wire)
- Output Terminals: ±5 V analog output and signal ground
- Power Terminals: 24 V DC supply and ground




6. Installation & Setup
Requirements:
- 24 V DC power supply with adequate current capacity
- Properly rated Pt500 or Pt1000 RTD sensor
- Analog input device capable of reading ±5 V signals

Mounting Options:
- Standard 35 mm DIN rail (EN 60715)
- Optional panel mounting using screws or brackets

Configuration:
- Temperature range and scaling are typically preconfigured (“Bereiche wie vor”) or set via internal jumpers or DIP switches.
- Wiring must follow the polarity and terminal labeling indicated on the module housing.
- Ensure proper grounding and shielding of sensor cables to minimize noise.

Setup Procedure:
1. Mount the module securely on the DIN rail.
2. Connect the Pt500/Pt1000 sensor leads to the designated input terminals.
3. Connect the ±5 V output to the receiving device (PLC, controller, or DAQ).
4. Supply 24 V DC power to the module.
5. Verify correct operation by comparing output voltage with expected temperature readings.

Safety Considerations:
- Disconnect power before wiring or maintenance.
- Avoid exposure to moisture or conductive dust.
- Ensure compliance with local electrical installation standards.




7. Performance & Capabilities
Speed and Response:
The MDTPT360x provides near real-time temperature measurement with a typical response time under one second, suitable for dynamic process monitoring.

Capacity and Range:
Supports a wide range of temperature spans depending on sensor type and configuration. The ±5 V output allows symmetrical scaling around zero, ideal for applications requiring bipolar temperature representation.

Efficiency:
Low power consumption (<1 W) and high signal integrity make it suitable for distributed measurement systems with multiple modules operating simultaneously.

Accuracy and Stability:
High-precision internal reference and low-drift components ensure consistent measurement accuracy over time and temperature variations.

Limitations:
- Designed for Pt500/Pt1000 sensors only; not compatible with thermocouples or other RTD types without modification.
- Output limited to ±5 V; systems requiring 0–10 V or 4–20 mA outputs may need additional signal conversion.
- Intended for indoor or cabinet-mounted use (IP20 protection).




8. Standards & Compliance
Certifications and Compliance:
- Electrical Safety: Conforms to EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use)
- EMC Compliance: Meets EN 61326-1 (EMC requirements for electrical equipment for measurement, control, and laboratory use)
- RoHS Compliance: Manufactured in accordance with Directive 2011/65/EU (Restriction of Hazardous Substances)
- WEEE Directive: Complies with 2012/19/EU for waste electrical and electronic equipment disposal
- Temperature Sensor Standard: Compatible with DIN EN 60751 (standard for industrial platinum resistance thermometers)

Industry Standards:
- Analog output conforms to standard ±5 V signal levels used in industrial automation and instrumentation.
- Designed for integration into systems following IEC 61131-2 (Programmable Controllers – Equipment Requirements).




9. Additional Information
Warranty:
Typically supplied with a 24-month manufacturer’s warranty covering defects in materials and workmanship under normal operating conditions.

Support:
MDT provides technical documentation, wiring diagrams, and configuration guides. Technical support is available via email or phone for installation and troubleshooting assistance.

Maintenance:
- The module requires minimal maintenance.
- Periodic inspection of terminal connections and sensor wiring is recommended.
- Calibration verification may be performed annually or as required by quality assurance protocols.

Firmware/Hardware Updates:
As an analog signal conditioning device, the MDTPT360x typically does not require firmware updates. Hardware revisions may be released to improve performance or expand compatibility.

Service and Replacement:
Modules are field-replaceable. In case of malfunction, replacement with an identical model (MDTPT360x) ensures system continuity without recalibration of the receiving system.

Environmental Considerations:
- Designed for installation in control cabinets or protected environments.
- Dispose of the module according to local electronic waste regulations.




Summary
The MDTPT360x Pt500/Pt1000 Module is a high-precision, industrial-grade temperature signal converter that transforms RTD sensor inputs into a standardized ±5 V analog output. Engineered for reliability, accuracy, and ease of integration, it supports Pt500 and Pt1000 sensors across configurable temperature ranges. Its robust design, electrical isolation, and compliance with international standards make it ideal for process control, automation, and instrumentation applications. With straightforward installation, low maintenance requirements, and consistent performance, the MDTPT360x provides a dependable interface between temperature sensors and control systems in both industrial and laboratory environments.

Keine Manuals/Kataloge verfügbar.

Kein Zubehör vorhanden.