SUCHEN SIE DIE PASSENDE
INDUSTRIELLE LÖSUNG?
Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.
- True RMS Measurement: Provides accurate measurement of AC power independent of waveform distortion, ensuring reliable readings even with non-sinusoidal loads.
- Measurement Range: 0 to 100 VA, suitable for low-power AC circuits and instrumentation applications.
- Analog Output: Linear output signal of 0 to 5 V DC corresponding to the measured power range, enabling easy interfacing with PLCs, data acquisition systems, or analog input modules.
- Galvanic Isolation: The output is electrically isolated from the measurement circuit, enhancing safety and minimizing interference or ground loop issues.
- External Modular Design: Housed in an external modular enclosure (Anreihgehäuse) for convenient installation alongside other control or measurement modules.
- Compact and Robust Construction: Designed for industrial environments, offering mechanical stability and long-term reliability.
- Ease of Integration: Standardized output and form factor allow seamless integration into existing monitoring and control systems.
- Low Maintenance: Solid-state measurement circuitry with minimal drift and no moving parts ensures long operational life and low maintenance requirements.
- Measurement Range: 0 to 100 VA, suitable for low-power AC circuits and instrumentation applications.
- Analog Output: Linear output signal of 0 to 5 V DC corresponding to the measured power range, enabling easy interfacing with PLCs, data acquisition systems, or analog input modules.
- Galvanic Isolation: The output is electrically isolated from the measurement circuit, enhancing safety and minimizing interference or ground loop issues.
- External Modular Design: Housed in an external modular enclosure (Anreihgehäuse) for convenient installation alongside other control or measurement modules.
- Compact and Robust Construction: Designed for industrial environments, offering mechanical stability and long-term reliability.
- Ease of Integration: Standardized output and form factor allow seamless integration into existing monitoring and control systems.
- Low Maintenance: Solid-state measurement circuitry with minimal drift and no moving parts ensures long operational life and low maintenance requirements.
1. Product Overview
Product Name: MPVA100
Model: MPVA100
Series: MPV Series – Power Measurement Modules
Article Number: MPVA100
Manufacturer: [Manufacturer not specified in source; typically supplied by an industrial measurement or automation equipment provider]
The MPVA100 is a compact, external power measurement module designed for precise True RMS measurement of electrical power in AC networks. It is engineered to measure apparent power up to 100 VA and provides a galvanically isolated analog output signal in the range of 0 to 5 V. The device is housed in a modular, DIN-rail-compatible enclosure suitable for integration into industrial control panels, laboratory setups, and energy monitoring systems.
2. Key Features
- True RMS Measurement: Provides accurate measurement of AC power independent of waveform distortion, ensuring reliable readings even with non-sinusoidal loads.
- Measurement Range: 0 to 100 VA, suitable for low-power AC circuits and instrumentation applications.
- Analog Output: Linear output signal of 0 to 5 V DC corresponding to the measured power range, enabling easy interfacing with PLCs, data acquisition systems, or analog input modules.
- Galvanic Isolation: The output is electrically isolated from the measurement circuit, enhancing safety and minimizing interference or ground loop issues.
- External Modular Design: Housed in an external modular enclosure (Anreihgehäuse) for convenient installation alongside other control or measurement modules.
- Compact and Robust Construction: Designed for industrial environments, offering mechanical stability and long-term reliability.
- Ease of Integration: Standardized output and form factor allow seamless integration into existing monitoring and control systems.
- Low Maintenance: Solid-state measurement circuitry with minimal drift and no moving parts ensures long operational life and low maintenance requirements.
3. Technical Specifications
*(Note: Some values are inferred based on standard module characteristics; exact manufacturer data should be confirmed.)*
- Measurement Type: True RMS power measurement (apparent power)
- Measurement Range: 0 to 100 VA
- Input Voltage Range: Typically compatible with standard AC mains voltages (e.g., 230 V AC nominal, depending on configuration)
- Input Current Range: Determined by internal scaling to achieve 100 VA full-scale measurement (e.g., 0.43 A at 230 V AC nominal)
- Output Signal: 0 to 5 V DC, proportional to measured power
- Output Type: Analog voltage output, linear scaling
- Output Isolation: Galvanically isolated from input circuit
- Accuracy: True RMS measurement accuracy typically within ±1% of full scale (depending on calibration and load conditions)
- Response Time: Fast response suitable for dynamic load monitoring (typically <100 ms)
- Power Supply: External supply (commonly 24 V DC or as specified by manufacturer)
- Power Consumption: Low, typically <2 W
- Enclosure Type: External modular housing (Anreihgehäuse) for DIN rail mounting
- Dimensions: Approx. 90 × 70 × 60 mm (typical for modular enclosures)
- Weight: Approx. 150–250 g
- Material: Industrial-grade ABS or polycarbonate housing, flame-retardant
- Operating Temperature: -10 °C to +55 °C (typical)
- Storage Temperature: -25 °C to +70 °C
- Humidity: 0–90% RH, non-condensing
- Protection Class: IP20 (for indoor installation within control cabinets)
4. Functionality
The MPVA100 operates as a precision measurement interface for monitoring electrical power in AC circuits. It measures the instantaneous voltage and current of the connected load, computes the True RMS value of apparent power (in VA), and converts this measurement into a proportional analog voltage output between 0 and 5 V.
Working Principle:
1. The module samples the AC voltage and current signals.
2. Internal signal conditioning circuits rectify and filter the signals to compute the True RMS value.
3. The computed RMS power value is scaled linearly to the 0–5 V output range.
4. The output is galvanically isolated from the input, ensuring safe and interference-free signal transmission.
Use Cases and Applications:
- Monitoring of AC power consumption in laboratory or test setups.
- Integration into industrial automation systems for process monitoring.
- Energy management and efficiency analysis in small-scale electrical systems.
- Measurement of power in control cabinets, instrumentation panels, or distributed monitoring networks.
- Educational and research applications requiring accurate low-power AC measurement.
Compatibility:
- Compatible with standard analog input channels of PLCs, SCADA systems, and data loggers.
- Can interface with analog-to-digital converters or monitoring software for real-time data acquisition.
- Suitable for use with both single-phase AC circuits and test benches.
5. Components & Accessories
Included Items:
- MPVA100 power measurement module in external modular housing.
- Terminal connectors for input and output wiring.
- Quick-start installation guide or datasheet (depending on supplier).
Optional Accessories:
- DIN rail mounting clips or brackets (if not pre-installed).
- Shielded connection cables for voltage and current inputs.
- Calibration certificate (optional, depending on supplier).
- Protective terminal covers or labeling kits for panel integration.
Connectors:
- Input Terminals: For AC voltage and current measurement inputs.
- Output Terminals: For 0–5 V analog output signal.
- Power Supply Terminals: For external DC supply connection.
6. Installation & Setup
Requirements:
- Suitable for installation in dry, indoor environments within control cabinets or enclosures.
- Requires a stable power supply (typically 24 V DC).
- Ensure proper wiring according to polarity and terminal labeling.
Mounting Options:
- Designed for DIN rail mounting (standard 35 mm rail).
- Can also be panel-mounted using optional brackets.
Configuration:
- Factory-calibrated for 0–100 VA measurement range.
- Output scaling is linear: 0 V corresponds to 0 VA, 5 V corresponds to 100 VA.
- No user calibration typically required; however, fine adjustment may be possible via internal trimmers (if provided).
Installation Steps:
1. Mount the module securely on the DIN rail.
2. Connect the AC measurement inputs to the designated terminals (observe correct wiring and safety precautions).
3. Connect the analog output to the receiving device (PLC, DAQ, etc.).
4. Connect the power supply to the module.
5. Verify output scaling using a known load for calibration check.
Safety Considerations:
- Ensure all wiring is performed with power disconnected.
- Observe local electrical safety standards and protective grounding requirements.
- Use appropriate fuses or circuit protection devices.
7. Performance & Capabilities
Measurement Performance:
- True RMS computation ensures accurate readings under distorted or non-sinusoidal waveforms.
- Stable output with minimal noise due to galvanic isolation and internal filtering.
- High linearity across the full measurement range (0–100 VA).
Speed and Response:
- Fast analog response suitable for dynamic load monitoring and control feedback loops.
- Typical response time <100 ms for step changes in load.
Capacity and Range:
- Designed for low to medium power measurement applications up to 100 VA.
- Ideal for instrumentation, laboratory, and small-scale industrial systems.
Efficiency:
- Low internal power consumption (<2 W).
- High electrical isolation efficiency, minimizing cross-interference.
Limitations:
- Not intended for high-power or three-phase measurement applications.
- Measurement range limited to 100 VA; exceeding this may cause output saturation.
- Requires proper scaling if used with external current or voltage transformers for higher ranges.
8. Standards & Compliance
Certifications and Compliance:
- Designed in accordance with industrial measurement and safety standards (typical compliance includes):
- EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use.
- EN 61326-1: EMC requirements for electrical equipment for measurement and control.
- RoHS Directive (2011/65/EU): Restriction of hazardous substances compliance.
- CE Marking: Conformity with European safety and EMC directives.
Industry Standards:
- Analog output standard: 0–5 V DC, compatible with most industrial control systems.
- Isolation and insulation designed to meet industrial-grade requirements for measurement modules.
9. Additional Information
Warranty:
- Standard manufacturer warranty (typically 12–24 months) covering defects in materials and workmanship.
Support:
- Technical documentation, wiring diagrams, and calibration data available from the manufacturer or distributor.
- Customer support for installation, troubleshooting, and integration assistance.
Maintenance:
- Virtually maintenance-free due to solid-state design.
- Periodic verification of calibration recommended for critical measurement applications.
- Keep terminals clean and ensure secure connections to maintain measurement accuracy.
Updates and Revisions:
- Firmware or hardware revisions may be released to improve measurement accuracy or expand compatibility.
- Updated datasheets and manuals typically available through the manufacturer’s website.
Summary
The MPVA100 True RMS Power Measurement Module is a precision instrument designed for accurate measurement of AC apparent power up to 100 VA. With its 0–5 V galvanically isolated output, it provides a reliable analog signal for integration into control systems, data acquisition setups, and energy monitoring applications. Its True RMS measurement capability ensures accuracy even under distorted waveforms, while the external modular housing allows easy installation in industrial environments.
Engineered for safety, reliability, and ease of integration, the MPVA100 is ideal for engineers, technicians, and system integrators seeking a compact and dependable solution for low-power AC measurement tasks. Its combination of robust design, galvanic isolation, and standardized output makes it a versatile component in modern automation and instrumentation systems.
Product Name: MPVA100
Model: MPVA100
Series: MPV Series – Power Measurement Modules
Article Number: MPVA100
Manufacturer: [Manufacturer not specified in source; typically supplied by an industrial measurement or automation equipment provider]
The MPVA100 is a compact, external power measurement module designed for precise True RMS measurement of electrical power in AC networks. It is engineered to measure apparent power up to 100 VA and provides a galvanically isolated analog output signal in the range of 0 to 5 V. The device is housed in a modular, DIN-rail-compatible enclosure suitable for integration into industrial control panels, laboratory setups, and energy monitoring systems.
2. Key Features
- True RMS Measurement: Provides accurate measurement of AC power independent of waveform distortion, ensuring reliable readings even with non-sinusoidal loads.
- Measurement Range: 0 to 100 VA, suitable for low-power AC circuits and instrumentation applications.
- Analog Output: Linear output signal of 0 to 5 V DC corresponding to the measured power range, enabling easy interfacing with PLCs, data acquisition systems, or analog input modules.
- Galvanic Isolation: The output is electrically isolated from the measurement circuit, enhancing safety and minimizing interference or ground loop issues.
- External Modular Design: Housed in an external modular enclosure (Anreihgehäuse) for convenient installation alongside other control or measurement modules.
- Compact and Robust Construction: Designed for industrial environments, offering mechanical stability and long-term reliability.
- Ease of Integration: Standardized output and form factor allow seamless integration into existing monitoring and control systems.
- Low Maintenance: Solid-state measurement circuitry with minimal drift and no moving parts ensures long operational life and low maintenance requirements.
3. Technical Specifications
*(Note: Some values are inferred based on standard module characteristics; exact manufacturer data should be confirmed.)*
- Measurement Type: True RMS power measurement (apparent power)
- Measurement Range: 0 to 100 VA
- Input Voltage Range: Typically compatible with standard AC mains voltages (e.g., 230 V AC nominal, depending on configuration)
- Input Current Range: Determined by internal scaling to achieve 100 VA full-scale measurement (e.g., 0.43 A at 230 V AC nominal)
- Output Signal: 0 to 5 V DC, proportional to measured power
- Output Type: Analog voltage output, linear scaling
- Output Isolation: Galvanically isolated from input circuit
- Accuracy: True RMS measurement accuracy typically within ±1% of full scale (depending on calibration and load conditions)
- Response Time: Fast response suitable for dynamic load monitoring (typically <100 ms)
- Power Supply: External supply (commonly 24 V DC or as specified by manufacturer)
- Power Consumption: Low, typically <2 W
- Enclosure Type: External modular housing (Anreihgehäuse) for DIN rail mounting
- Dimensions: Approx. 90 × 70 × 60 mm (typical for modular enclosures)
- Weight: Approx. 150–250 g
- Material: Industrial-grade ABS or polycarbonate housing, flame-retardant
- Operating Temperature: -10 °C to +55 °C (typical)
- Storage Temperature: -25 °C to +70 °C
- Humidity: 0–90% RH, non-condensing
- Protection Class: IP20 (for indoor installation within control cabinets)
4. Functionality
The MPVA100 operates as a precision measurement interface for monitoring electrical power in AC circuits. It measures the instantaneous voltage and current of the connected load, computes the True RMS value of apparent power (in VA), and converts this measurement into a proportional analog voltage output between 0 and 5 V.
Working Principle:
1. The module samples the AC voltage and current signals.
2. Internal signal conditioning circuits rectify and filter the signals to compute the True RMS value.
3. The computed RMS power value is scaled linearly to the 0–5 V output range.
4. The output is galvanically isolated from the input, ensuring safe and interference-free signal transmission.
Use Cases and Applications:
- Monitoring of AC power consumption in laboratory or test setups.
- Integration into industrial automation systems for process monitoring.
- Energy management and efficiency analysis in small-scale electrical systems.
- Measurement of power in control cabinets, instrumentation panels, or distributed monitoring networks.
- Educational and research applications requiring accurate low-power AC measurement.
Compatibility:
- Compatible with standard analog input channels of PLCs, SCADA systems, and data loggers.
- Can interface with analog-to-digital converters or monitoring software for real-time data acquisition.
- Suitable for use with both single-phase AC circuits and test benches.
5. Components & Accessories
Included Items:
- MPVA100 power measurement module in external modular housing.
- Terminal connectors for input and output wiring.
- Quick-start installation guide or datasheet (depending on supplier).
Optional Accessories:
- DIN rail mounting clips or brackets (if not pre-installed).
- Shielded connection cables for voltage and current inputs.
- Calibration certificate (optional, depending on supplier).
- Protective terminal covers or labeling kits for panel integration.
Connectors:
- Input Terminals: For AC voltage and current measurement inputs.
- Output Terminals: For 0–5 V analog output signal.
- Power Supply Terminals: For external DC supply connection.
6. Installation & Setup
Requirements:
- Suitable for installation in dry, indoor environments within control cabinets or enclosures.
- Requires a stable power supply (typically 24 V DC).
- Ensure proper wiring according to polarity and terminal labeling.
Mounting Options:
- Designed for DIN rail mounting (standard 35 mm rail).
- Can also be panel-mounted using optional brackets.
Configuration:
- Factory-calibrated for 0–100 VA measurement range.
- Output scaling is linear: 0 V corresponds to 0 VA, 5 V corresponds to 100 VA.
- No user calibration typically required; however, fine adjustment may be possible via internal trimmers (if provided).
Installation Steps:
1. Mount the module securely on the DIN rail.
2. Connect the AC measurement inputs to the designated terminals (observe correct wiring and safety precautions).
3. Connect the analog output to the receiving device (PLC, DAQ, etc.).
4. Connect the power supply to the module.
5. Verify output scaling using a known load for calibration check.
Safety Considerations:
- Ensure all wiring is performed with power disconnected.
- Observe local electrical safety standards and protective grounding requirements.
- Use appropriate fuses or circuit protection devices.
7. Performance & Capabilities
Measurement Performance:
- True RMS computation ensures accurate readings under distorted or non-sinusoidal waveforms.
- Stable output with minimal noise due to galvanic isolation and internal filtering.
- High linearity across the full measurement range (0–100 VA).
Speed and Response:
- Fast analog response suitable for dynamic load monitoring and control feedback loops.
- Typical response time <100 ms for step changes in load.
Capacity and Range:
- Designed for low to medium power measurement applications up to 100 VA.
- Ideal for instrumentation, laboratory, and small-scale industrial systems.
Efficiency:
- Low internal power consumption (<2 W).
- High electrical isolation efficiency, minimizing cross-interference.
Limitations:
- Not intended for high-power or three-phase measurement applications.
- Measurement range limited to 100 VA; exceeding this may cause output saturation.
- Requires proper scaling if used with external current or voltage transformers for higher ranges.
8. Standards & Compliance
Certifications and Compliance:
- Designed in accordance with industrial measurement and safety standards (typical compliance includes):
- EN 61010-1: Safety requirements for electrical equipment for measurement, control, and laboratory use.
- EN 61326-1: EMC requirements for electrical equipment for measurement and control.
- RoHS Directive (2011/65/EU): Restriction of hazardous substances compliance.
- CE Marking: Conformity with European safety and EMC directives.
Industry Standards:
- Analog output standard: 0–5 V DC, compatible with most industrial control systems.
- Isolation and insulation designed to meet industrial-grade requirements for measurement modules.
9. Additional Information
Warranty:
- Standard manufacturer warranty (typically 12–24 months) covering defects in materials and workmanship.
Support:
- Technical documentation, wiring diagrams, and calibration data available from the manufacturer or distributor.
- Customer support for installation, troubleshooting, and integration assistance.
Maintenance:
- Virtually maintenance-free due to solid-state design.
- Periodic verification of calibration recommended for critical measurement applications.
- Keep terminals clean and ensure secure connections to maintain measurement accuracy.
Updates and Revisions:
- Firmware or hardware revisions may be released to improve measurement accuracy or expand compatibility.
- Updated datasheets and manuals typically available through the manufacturer’s website.
Summary
The MPVA100 True RMS Power Measurement Module is a precision instrument designed for accurate measurement of AC apparent power up to 100 VA. With its 0–5 V galvanically isolated output, it provides a reliable analog signal for integration into control systems, data acquisition setups, and energy monitoring applications. Its True RMS measurement capability ensures accuracy even under distorted waveforms, while the external modular housing allows easy installation in industrial environments.
Engineered for safety, reliability, and ease of integration, the MPVA100 is ideal for engineers, technicians, and system integrators seeking a compact and dependable solution for low-power AC measurement tasks. Its combination of robust design, galvanic isolation, and standardized output makes it a versatile component in modern automation and instrumentation systems.
Keine Manuals/Kataloge verfügbar.