SUCHEN SIE DIE PASSENDE
INDUSTRIELLE LÖSUNG?
Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.
- 32 Independent Reed Relay Outputs:
Provides 32 single‑pole, single‑throw (SPST‑NO) reed relay contacts organized into four groups of eight channels each. Each group shares a common terminal.
- High Isolation and Safety:
Mechanical relay isolation ensures complete galvanic separation between PC logic and external circuits, protecting the host system from voltage surges and noise.
- Output Ratings:
Capable of switching up to 100 V AC / 100 V DC, with a maximum load of 0.5 A per channel and 1 A per common group (8 channels).
Maximum switching power: 10 VA (AC) / 10 W (DC).
- Fast Switching:
Typical relay response time is < 1 ms, enabling rapid control of external devices.
- Long Mechanical Life:
Minimum mechanical life expectancy of 200 million operations, ensuring long‑term reliability in continuous operation.
- PCI Bus Compliance:
Fully compliant with PCI 2.2 (32‑bit, 33 MHz, 5 V signaling).
Supports both 5 V and 3.3 V keyed slots (universal connector).
- Software Support:
Bundled with API‑PAC(W32) driver library for Windows and API‑DIO(LNX) for Linux.
Compatible with LabVIEW VI‑DAQ library for graphical programming.
- Diagnostic and Configuration Tools:
Includes API‑TOOL Configuration utility and diagnostic software for board detection, I/O testing, and interrupt verification.
- Compact PCI Short‑Size Form Factor:
Dimensions: 176.41 mm (L) × 105.68 mm (H) – fits standard PCI slots.
- Standard 37‑Pin D‑SUB Connector:
Female D‑type connector (JAE DCLC‑J37SAF‑20L9 or equivalent) for external wiring.
- High Reliability Components:
Utilizes MSG‑105AK1 or equivalent high‑durability reed relays.
Provides 32 single‑pole, single‑throw (SPST‑NO) reed relay contacts organized into four groups of eight channels each. Each group shares a common terminal.
- High Isolation and Safety:
Mechanical relay isolation ensures complete galvanic separation between PC logic and external circuits, protecting the host system from voltage surges and noise.
- Output Ratings:
Capable of switching up to 100 V AC / 100 V DC, with a maximum load of 0.5 A per channel and 1 A per common group (8 channels).
Maximum switching power: 10 VA (AC) / 10 W (DC).
- Fast Switching:
Typical relay response time is < 1 ms, enabling rapid control of external devices.
- Long Mechanical Life:
Minimum mechanical life expectancy of 200 million operations, ensuring long‑term reliability in continuous operation.
- PCI Bus Compliance:
Fully compliant with PCI 2.2 (32‑bit, 33 MHz, 5 V signaling).
Supports both 5 V and 3.3 V keyed slots (universal connector).
- Software Support:
Bundled with API‑PAC(W32) driver library for Windows and API‑DIO(LNX) for Linux.
Compatible with LabVIEW VI‑DAQ library for graphical programming.
- Diagnostic and Configuration Tools:
Includes API‑TOOL Configuration utility and diagnostic software for board detection, I/O testing, and interrupt verification.
- Compact PCI Short‑Size Form Factor:
Dimensions: 176.41 mm (L) × 105.68 mm (H) – fits standard PCI slots.
- Standard 37‑Pin D‑SUB Connector:
Female D‑type connector (JAE DCLC‑J37SAF‑20L9 or equivalent) for external wiring.
- High Reliability Components:
Utilizes MSG‑105AK1 or equivalent high‑durability reed relays.
Comprehensive Product Summary – CONTEC RRY‑32(PCI) Reed Relay Output Board
### 1. Product Overview
Product Name: PCI Bus 32‑Channel Reed Relay Output Board
Model: RRY‑32(PCI)
Series: CONTEC Digital I/O – Relay Output Series
Article Number: RRY‑32(PCI)
Manufacturer: CONTEC Co., Ltd. (Japan)
Product Category: Industrial Automation / Measurement and Control / Digital I/O Interface Boards
Bus Type: PCI (32‑bit, 33 MHz, 5 V)
The CONTEC RRY‑32(PCI) is a 32‑channel reed relay output board designed for industrial and laboratory automation systems requiring electrically isolated, high‑reliability digital output control. It provides mechanical relay isolation between the PC’s logic circuitry and external devices, enabling safe switching of AC or DC loads. The board is fully compliant with the PCI bus standard and is supported by CONTEC’s API‑PAC(W32) driver library for Windows and API‑DIO(LNX) for Linux.
### 2. Key Features
- 32 Independent Reed Relay Outputs:
Provides 32 single‑pole, single‑throw (SPST‑NO) reed relay contacts organized into four groups of eight channels each. Each group shares a common terminal.
- High Isolation and Safety:
Mechanical relay isolation ensures complete galvanic separation between PC logic and external circuits, protecting the host system from voltage surges and noise.
- Output Ratings:
Capable of switching up to 100 V AC / 100 V DC, with a maximum load of 0.5 A per channel and 1 A per common group (8 channels).
Maximum switching power: 10 VA (AC) / 10 W (DC).
- Fast Switching:
Typical relay response time is < 1 ms, enabling rapid control of external devices.
- Long Mechanical Life:
Minimum mechanical life expectancy of 200 million operations, ensuring long‑term reliability in continuous operation.
- PCI Bus Compliance:
Fully compliant with PCI 2.2 (32‑bit, 33 MHz, 5 V signaling).
Supports both 5 V and 3.3 V keyed slots (universal connector).
- Software Support:
Bundled with API‑PAC(W32) driver library for Windows and API‑DIO(LNX) for Linux.
Compatible with LabVIEW VI‑DAQ library for graphical programming.
- Diagnostic and Configuration Tools:
Includes API‑TOOL Configuration utility and diagnostic software for board detection, I/O testing, and interrupt verification.
- Compact PCI Short‑Size Form Factor:
Dimensions: 176.41 mm (L) × 105.68 mm (H) – fits standard PCI slots.
- Standard 37‑Pin D‑SUB Connector:
Female D‑type connector (JAE DCLC‑J37SAF‑20L9 or equivalent) for external wiring.
- High Reliability Components:
Utilizes MSG‑105AK1 or equivalent high‑durability reed relays.
### 3. Technical Specifications
| Parameter | Specification |
|----------------|------------------|
| Output Channels | 32 channels (4 groups × 8 points) |
| Output Type | Reed relay contact (1a, normally open) |
| Contact Configuration | SPST‑NO (single make contact) |
| Maximum Switching Voltage | 100 V AC / 100 V DC |
| Maximum Switching Current | 0.5 A per channel |
| Maximum Carry Current | 1 A per common (8‑point group) |
| Maximum Switching Power | 10 VA (AC) / 10 W (DC) |
| Contact Resistance | ≤ 100 mΩ (initial) |
| Response Time | ≤ 1 ms |
| Mechanical Life Expectancy | ≥ 200 million operations |
| Electrical Life Expectancy | ≥ 100,000 operations (typical load) |
| Relay Type | MSG‑105AK1 or equivalent |
| Isolation Method | Mechanical relay isolation |
| I/O Address Range | 8 bits × 32 ports boundary |
| Maximum Boards per System | 16 boards |
| Power Supply (from PCI bus) | +5 V DC, 1050 mA (max.) |
| Operating Temperature | 0 – 50 °C |
| Operating Humidity | 10 – 90 % RH (non‑condensing) |
| Storage Temperature | −10 – 60 °C |
| Bus Interface | PCI 32‑bit, 33 MHz, 5 V signaling |
| Board Dimensions | 176.41 (L) × 105.68 (H) mm |
| Weight | Approx. 150 g |
| Connector Type | 37‑pin D‑SUB female (JAE DCLC‑J37SAF‑20L9) |
| Mounting | Standard PCI slot (universal key) |
### 4. Functionality
Operating Principle:
Each output channel uses a reed relay contact that closes when the corresponding bit is set to logic “1” by the host PC. When the bit is cleared to “0,” the contact opens. The relay provides complete electrical isolation between the control logic and the external load circuit.
Use Cases and Applications:
- Industrial automation and process control
- Test benches and measurement systems
- Signal routing and switching of analog or digital lines
- Control of external actuators, solenoids, or indicators
- Laboratory instrumentation requiring isolated switching
- Safety interlock or alarm control systems
Compatibility:
- Compatible with all CONTEC PCI digital I/O boards and accessories.
- Supported by Windows (XP/7/10/11), Linux distributions (Red Hat, Ubuntu, etc.), and LabVIEW environments.
- Can coexist with up to 15 additional CONTEC PCI boards in one system.
Software Operation:
- Output data is written via API‑PAC(W32) functions (e.g., DioOutBit, DioOutPort).
- The board retains output states until new data is written.
- Output status can be read back for verification without affecting relay state.
### 5. Components & Accessories
Included Items:
- RRY‑32(PCI) board
- First‑step guide
- CD‑ROM containing API‑PAC(W32) driver library, documentation, and sample programs
Optional Accessories:
- Cables:
- PCB37P‑1.5 / ‑3 / ‑5 m (flat cable, both‑end 37‑pin D‑SUB)
- PCB37PS‑0.5P / ‑1.5P / ‑3P / ‑5P m (shielded cable, both‑end 37‑pin D‑SUB)
- PCA37P‑1.5 / ‑3 / ‑5 m (flat cable, one‑end 37‑pin D‑SUB)
- PCA37PS‑0.5P / ‑1.5P / ‑3P / ‑5P m (shielded cable, one‑end 37‑pin D‑SUB)
- Connectors:
- CN5‑D37M (37‑pin D‑SUB male connector set, 5 pcs)
- Terminal Blocks:
- EPD‑37A (screw terminal block, DIN‑rail mountable)
- EPD‑37 (screw‑up type terminal unit)
- DTP‑3(PC) (terminal block for M3 solderless terminals)
- DTP‑4(PC) (terminal block for lead wires)
Cable Current Ratings:
- Flat cable (PCB37P/PCA37P): 1 A max per line
- Shielded cable (PCB37PS/PCA37PS): 0.4 A max per line
### 6. Installation & Setup
System Requirements:
- IBM PC/AT compatible computer with available PCI slot
- Operating system: Windows XP/7/8/10/11 or Linux kernel 2.6+
- Minimum 50 MB free disk space for driver installation
Installation Steps:
1. Install Software First:
Run the API‑PAC(W32) installer from the CD‑ROM before inserting the board.
2. Set Board ID:
Use the on‑board rotary switch (SW1) to assign a unique ID (0–Fh) if multiple boards are installed.
3. Insert Board:
Power off the PC, insert the board into a PCI slot, and secure it with a screw.
4. Power On and Detect:
Windows Plug‑and‑Play automatically detects the board. Specify the INF file path:
`\INF\Win2000\Dio\PCI` (for Windows 2000/XP) or `\INF\Win95\Dio\PCI` (for Windows 9x).
5. Initialize with API‑TOOL Configuration:
Launch “API‑TOOL Configuration” to register the board and save settings to the registry.
6. Verify Operation:
Use the included Diagnosis Program to test relay outputs and confirm correct operation.
Mounting:
Fits standard or low‑profile PCI slots (universal key). Ensure adequate airflow and avoid high‑temperature environments.
### 7. Performance & Capabilities
| Parameter | Performance |
|----------------|----------------|
| Switching Speed | ≤ 1 ms (typical) |
| Contact Bounce | Negligible (reed relay type) |
| Load Capacity | 10 VA (AC) / 10 W (DC) |
| Isolation Voltage | > 1000 Vrms between logic and output |
| Reliability | 200 million mechanical operations minimum |
| Noise Immunity | Excellent – mechanical isolation prevents ground loops |
| Power Consumption | 5 V DC ± 5 %, 1050 mA (max.) |
| Bus Throughput | PCI 32‑bit / 33 MHz – 133 MB/s theoretical |
| Limitations | Not suitable for high‑frequency PWM or analog switching; mechanical relay delay applies |
Operational Notes:
- All outputs default to OFF (open) at power‑on or system reset.
- Relay contacts are polarity‑independent and can switch AC or DC loads.
- Recommended wiring distance ≤ 50 m to minimize signal degradation.
- Avoid exceeding rated voltage/current to prevent contact wear.
### 8. Standards & Compliance
- Bus Standard: PCI 2.2 compliant (32‑bit, 33 MHz, 5 V signaling)
- Electrical Safety: Designed for industrial low‑voltage control circuits
- Environmental Conditions: 0–50 °C, 10–90 % RH (non‑condensing)
- RoHS Compliance: Components selected to meet RoHS directives
- EMC Considerations: Use shielded cables and proper grounding for noise‑sensitive environments
- Software Standards:
- Windows API‑PAC(W32) conforms to Win32 API conventions
- Linux API‑DIO(LNX) provides kernel‑module device driver and shared library interface
- Quality Assurance: Manufactured under ISO 9001‑certified processes
### 9. Additional Information
Warranty:
Three‑year limited warranty covering defects in materials and workmanship.
Excludes damage from misuse, modification, or improper installation.
Support & Service:
- Website: [https://www.contec.com](https://www.contec.com)
- Downloads: Latest drivers, manuals, and sample code available free of charge.
- Technical Support: Provided through CONTEC regional offices and distributors.
- RMA Procedure: Obtain Return Merchandise Authorization before returning any product.
Maintenance:
- Periodically inspect connectors and cables for dust or corrosion.
- Avoid mechanical shock or bending of the board.
- Clean edge connectors with industrial alcohol if contaminated.
- Store in anti‑static packaging at room temperature when not in use.
Software Updates:
API‑PAC(W32) and API‑DIO(LNX) updates are periodically released to support new OS versions and improve performance.
LabVIEW VI‑DAQ library available for free download for integration with National Instruments environments.
Safety Precautions:
- Do not install or remove the board while the PC is powered.
- Ensure external circuits do not exceed rated voltage/current.
- Avoid use in environments with flammable gases or excessive dust.
- Provide adequate ventilation to prevent overheating.
### Summary
The CONTEC RRY‑32(PCI) is a robust, industrial‑grade 32‑channel reed relay output board for PCI‑based systems. It offers mechanical isolation, high reliability, and broad software support, making it ideal for controlling external devices in automation, testing, and measurement applications. With its 10 VA/10 W switching capacity, 1 ms response time, and 200 million‑cycle life, the RRY‑32(PCI) delivers dependable performance in demanding environments. Supported by comprehensive driver libraries for Windows, Linux, and LabVIEW, it integrates seamlessly into modern control and data acquisition systems.
### 1. Product Overview
Product Name: PCI Bus 32‑Channel Reed Relay Output Board
Model: RRY‑32(PCI)
Series: CONTEC Digital I/O – Relay Output Series
Article Number: RRY‑32(PCI)
Manufacturer: CONTEC Co., Ltd. (Japan)
Product Category: Industrial Automation / Measurement and Control / Digital I/O Interface Boards
Bus Type: PCI (32‑bit, 33 MHz, 5 V)
The CONTEC RRY‑32(PCI) is a 32‑channel reed relay output board designed for industrial and laboratory automation systems requiring electrically isolated, high‑reliability digital output control. It provides mechanical relay isolation between the PC’s logic circuitry and external devices, enabling safe switching of AC or DC loads. The board is fully compliant with the PCI bus standard and is supported by CONTEC’s API‑PAC(W32) driver library for Windows and API‑DIO(LNX) for Linux.
### 2. Key Features
- 32 Independent Reed Relay Outputs:
Provides 32 single‑pole, single‑throw (SPST‑NO) reed relay contacts organized into four groups of eight channels each. Each group shares a common terminal.
- High Isolation and Safety:
Mechanical relay isolation ensures complete galvanic separation between PC logic and external circuits, protecting the host system from voltage surges and noise.
- Output Ratings:
Capable of switching up to 100 V AC / 100 V DC, with a maximum load of 0.5 A per channel and 1 A per common group (8 channels).
Maximum switching power: 10 VA (AC) / 10 W (DC).
- Fast Switching:
Typical relay response time is < 1 ms, enabling rapid control of external devices.
- Long Mechanical Life:
Minimum mechanical life expectancy of 200 million operations, ensuring long‑term reliability in continuous operation.
- PCI Bus Compliance:
Fully compliant with PCI 2.2 (32‑bit, 33 MHz, 5 V signaling).
Supports both 5 V and 3.3 V keyed slots (universal connector).
- Software Support:
Bundled with API‑PAC(W32) driver library for Windows and API‑DIO(LNX) for Linux.
Compatible with LabVIEW VI‑DAQ library for graphical programming.
- Diagnostic and Configuration Tools:
Includes API‑TOOL Configuration utility and diagnostic software for board detection, I/O testing, and interrupt verification.
- Compact PCI Short‑Size Form Factor:
Dimensions: 176.41 mm (L) × 105.68 mm (H) – fits standard PCI slots.
- Standard 37‑Pin D‑SUB Connector:
Female D‑type connector (JAE DCLC‑J37SAF‑20L9 or equivalent) for external wiring.
- High Reliability Components:
Utilizes MSG‑105AK1 or equivalent high‑durability reed relays.
### 3. Technical Specifications
| Parameter | Specification |
|----------------|------------------|
| Output Channels | 32 channels (4 groups × 8 points) |
| Output Type | Reed relay contact (1a, normally open) |
| Contact Configuration | SPST‑NO (single make contact) |
| Maximum Switching Voltage | 100 V AC / 100 V DC |
| Maximum Switching Current | 0.5 A per channel |
| Maximum Carry Current | 1 A per common (8‑point group) |
| Maximum Switching Power | 10 VA (AC) / 10 W (DC) |
| Contact Resistance | ≤ 100 mΩ (initial) |
| Response Time | ≤ 1 ms |
| Mechanical Life Expectancy | ≥ 200 million operations |
| Electrical Life Expectancy | ≥ 100,000 operations (typical load) |
| Relay Type | MSG‑105AK1 or equivalent |
| Isolation Method | Mechanical relay isolation |
| I/O Address Range | 8 bits × 32 ports boundary |
| Maximum Boards per System | 16 boards |
| Power Supply (from PCI bus) | +5 V DC, 1050 mA (max.) |
| Operating Temperature | 0 – 50 °C |
| Operating Humidity | 10 – 90 % RH (non‑condensing) |
| Storage Temperature | −10 – 60 °C |
| Bus Interface | PCI 32‑bit, 33 MHz, 5 V signaling |
| Board Dimensions | 176.41 (L) × 105.68 (H) mm |
| Weight | Approx. 150 g |
| Connector Type | 37‑pin D‑SUB female (JAE DCLC‑J37SAF‑20L9) |
| Mounting | Standard PCI slot (universal key) |
### 4. Functionality
Operating Principle:
Each output channel uses a reed relay contact that closes when the corresponding bit is set to logic “1” by the host PC. When the bit is cleared to “0,” the contact opens. The relay provides complete electrical isolation between the control logic and the external load circuit.
Use Cases and Applications:
- Industrial automation and process control
- Test benches and measurement systems
- Signal routing and switching of analog or digital lines
- Control of external actuators, solenoids, or indicators
- Laboratory instrumentation requiring isolated switching
- Safety interlock or alarm control systems
Compatibility:
- Compatible with all CONTEC PCI digital I/O boards and accessories.
- Supported by Windows (XP/7/10/11), Linux distributions (Red Hat, Ubuntu, etc.), and LabVIEW environments.
- Can coexist with up to 15 additional CONTEC PCI boards in one system.
Software Operation:
- Output data is written via API‑PAC(W32) functions (e.g., DioOutBit, DioOutPort).
- The board retains output states until new data is written.
- Output status can be read back for verification without affecting relay state.
### 5. Components & Accessories
Included Items:
- RRY‑32(PCI) board
- First‑step guide
- CD‑ROM containing API‑PAC(W32) driver library, documentation, and sample programs
Optional Accessories:
- Cables:
- PCB37P‑1.5 / ‑3 / ‑5 m (flat cable, both‑end 37‑pin D‑SUB)
- PCB37PS‑0.5P / ‑1.5P / ‑3P / ‑5P m (shielded cable, both‑end 37‑pin D‑SUB)
- PCA37P‑1.5 / ‑3 / ‑5 m (flat cable, one‑end 37‑pin D‑SUB)
- PCA37PS‑0.5P / ‑1.5P / ‑3P / ‑5P m (shielded cable, one‑end 37‑pin D‑SUB)
- Connectors:
- CN5‑D37M (37‑pin D‑SUB male connector set, 5 pcs)
- Terminal Blocks:
- EPD‑37A (screw terminal block, DIN‑rail mountable)
- EPD‑37 (screw‑up type terminal unit)
- DTP‑3(PC) (terminal block for M3 solderless terminals)
- DTP‑4(PC) (terminal block for lead wires)
Cable Current Ratings:
- Flat cable (PCB37P/PCA37P): 1 A max per line
- Shielded cable (PCB37PS/PCA37PS): 0.4 A max per line
### 6. Installation & Setup
System Requirements:
- IBM PC/AT compatible computer with available PCI slot
- Operating system: Windows XP/7/8/10/11 or Linux kernel 2.6+
- Minimum 50 MB free disk space for driver installation
Installation Steps:
1. Install Software First:
Run the API‑PAC(W32) installer from the CD‑ROM before inserting the board.
2. Set Board ID:
Use the on‑board rotary switch (SW1) to assign a unique ID (0–Fh) if multiple boards are installed.
3. Insert Board:
Power off the PC, insert the board into a PCI slot, and secure it with a screw.
4. Power On and Detect:
Windows Plug‑and‑Play automatically detects the board. Specify the INF file path:
`\INF\Win2000\Dio\PCI` (for Windows 2000/XP) or `\INF\Win95\Dio\PCI` (for Windows 9x).
5. Initialize with API‑TOOL Configuration:
Launch “API‑TOOL Configuration” to register the board and save settings to the registry.
6. Verify Operation:
Use the included Diagnosis Program to test relay outputs and confirm correct operation.
Mounting:
Fits standard or low‑profile PCI slots (universal key). Ensure adequate airflow and avoid high‑temperature environments.
### 7. Performance & Capabilities
| Parameter | Performance |
|----------------|----------------|
| Switching Speed | ≤ 1 ms (typical) |
| Contact Bounce | Negligible (reed relay type) |
| Load Capacity | 10 VA (AC) / 10 W (DC) |
| Isolation Voltage | > 1000 Vrms between logic and output |
| Reliability | 200 million mechanical operations minimum |
| Noise Immunity | Excellent – mechanical isolation prevents ground loops |
| Power Consumption | 5 V DC ± 5 %, 1050 mA (max.) |
| Bus Throughput | PCI 32‑bit / 33 MHz – 133 MB/s theoretical |
| Limitations | Not suitable for high‑frequency PWM or analog switching; mechanical relay delay applies |
Operational Notes:
- All outputs default to OFF (open) at power‑on or system reset.
- Relay contacts are polarity‑independent and can switch AC or DC loads.
- Recommended wiring distance ≤ 50 m to minimize signal degradation.
- Avoid exceeding rated voltage/current to prevent contact wear.
### 8. Standards & Compliance
- Bus Standard: PCI 2.2 compliant (32‑bit, 33 MHz, 5 V signaling)
- Electrical Safety: Designed for industrial low‑voltage control circuits
- Environmental Conditions: 0–50 °C, 10–90 % RH (non‑condensing)
- RoHS Compliance: Components selected to meet RoHS directives
- EMC Considerations: Use shielded cables and proper grounding for noise‑sensitive environments
- Software Standards:
- Windows API‑PAC(W32) conforms to Win32 API conventions
- Linux API‑DIO(LNX) provides kernel‑module device driver and shared library interface
- Quality Assurance: Manufactured under ISO 9001‑certified processes
### 9. Additional Information
Warranty:
Three‑year limited warranty covering defects in materials and workmanship.
Excludes damage from misuse, modification, or improper installation.
Support & Service:
- Website: [https://www.contec.com](https://www.contec.com)
- Downloads: Latest drivers, manuals, and sample code available free of charge.
- Technical Support: Provided through CONTEC regional offices and distributors.
- RMA Procedure: Obtain Return Merchandise Authorization before returning any product.
Maintenance:
- Periodically inspect connectors and cables for dust or corrosion.
- Avoid mechanical shock or bending of the board.
- Clean edge connectors with industrial alcohol if contaminated.
- Store in anti‑static packaging at room temperature when not in use.
Software Updates:
API‑PAC(W32) and API‑DIO(LNX) updates are periodically released to support new OS versions and improve performance.
LabVIEW VI‑DAQ library available for free download for integration with National Instruments environments.
Safety Precautions:
- Do not install or remove the board while the PC is powered.
- Ensure external circuits do not exceed rated voltage/current.
- Avoid use in environments with flammable gases or excessive dust.
- Provide adequate ventilation to prevent overheating.
### Summary
The CONTEC RRY‑32(PCI) is a robust, industrial‑grade 32‑channel reed relay output board for PCI‑based systems. It offers mechanical isolation, high reliability, and broad software support, making it ideal for controlling external devices in automation, testing, and measurement applications. With its 10 VA/10 W switching capacity, 1 ms response time, and 200 million‑cycle life, the RRY‑32(PCI) delivers dependable performance in demanding environments. Supported by comprehensive driver libraries for Windows, Linux, and LabVIEW, it integrates seamlessly into modern control and data acquisition systems.
-
ContecCatalog2011-2012-en-H Digital IO.pdf
PDF Catalog
-
RRY-32(PCI)H-manual.pdf
Manual
Kein Zubehör vorhanden.