SUCHEN SIE DIE PASSENDE

INDUSTRIELLE LÖSUNG?

Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.

VI-Driver-WIN

LabView driver for Contec Cards
  • Hersteller Contec
  • Kategorie: Contec Driver, Software
  • The VI-Driver-WIN is a dedicated software driver package developed by CONTEC Co., Ltd. to enable seamless integration of CONTEC’s wide range of analog, digital, counter, and communication interface cards with National Instruments’ LabVIEW environment. Designed for Windows operating systems, this driver suite provides a unified interface for data acquisition, control, and communication applications, allowing engineers and developers to build LabVIEW-based measurement and automation systems using CONTEC hardware.
- Full LabVIEW Compatibility:
The VI-Driver-WIN package provides a set of Virtual Instruments (VIs) that are fully compliant with National Instruments’ LabVIEW versions 7.1, 7.0, 6.1, and 6i. It allows direct control of CONTEC’s analog I/O, digital I/O, counter, and GPIB communication modules within the LabVIEW graphical programming environment.

- Unified VI Library (VI-DAQ):
The included VI-DAQ library mirrors the structure of LabVIEW’s native Data Acquisition VIs, simplifying the learning curve and enabling rapid system development without complex configuration.

- Hardware Independence:
The same VI functions can be used across multiple hardware platforms—PCI, CompactPCI, ISA, and PC Card—ensuring portability and scalability of applications.

- User-Friendly Interface:
Functions are organized into Basic VI (for common operations) and Expansion VI (for advanced configuration), allowing users to start quickly and expand functionality as needed.

- Comprehensive Sample Programs:
Practical examples such as “Easy Input,” “Using Trigger,” and “Consecutive Sampling” are provided to demonstrate analog input and other operations, facilitating faster development and debugging.

- Multi-Device Support:
Supports a wide range of CONTEC boards including analog input/output, digital I/O, counter/timer, motor control, serial communication, and GPIB interface cards.

- Cross-Language API Support:
In addition to LabVIEW, the driver suite supports Microsoft Visual Basic, Visual C++, Visual C#.NET, Visual Basic.NET, and Borland C++ Builder and Delphi, enabling hybrid development environments.

- Integrated Diagnostic and Configuration Tools:
Includes setup and diagnostic utilities for hardware configuration, IEEE488.2 parameter setup, and functional verification.

- Free Distribution and Updates:
The API-PAC(W32) and related driver libraries are provided free of charge, with updates and sample programs available for download from CONTEC’s global portal.

Ursprungsland: Japan

1. Product Overview

Product Name: VI-Driver-WIN
Model / Article Number: VI-Driver-WIN
Series: LabVIEW Driver Series for CONTEC Cards
Manufacturer: CONTEC Co., Ltd.
Product Category: Software Driver / LabVIEW Integration Package
Product Type: LabVIEW-compliant driver library for CONTEC data acquisition and communication cards

The VI-Driver-WIN is a dedicated software driver package developed by CONTEC Co., Ltd. to enable seamless integration of CONTEC’s wide range of analog, digital, counter, and communication interface cards with National Instruments’ LabVIEW environment. Designed for Windows operating systems, this driver suite provides a unified interface for data acquisition, control, and communication applications, allowing engineers and developers to build LabVIEW-based measurement and automation systems using CONTEC hardware.




2. Key Features

- Full LabVIEW Compatibility:
The VI-Driver-WIN package provides a set of Virtual Instruments (VIs) that are fully compliant with National Instruments’ LabVIEW versions 7.1, 7.0, 6.1, and 6i. It allows direct control of CONTEC’s analog I/O, digital I/O, counter, and GPIB communication modules within the LabVIEW graphical programming environment.

- Unified VI Library (VI-DAQ):
The included VI-DAQ library mirrors the structure of LabVIEW’s native Data Acquisition VIs, simplifying the learning curve and enabling rapid system development without complex configuration.

- Hardware Independence:
The same VI functions can be used across multiple hardware platforms—PCI, CompactPCI, ISA, and PC Card—ensuring portability and scalability of applications.

- User-Friendly Interface:
Functions are organized into Basic VI (for common operations) and Expansion VI (for advanced configuration), allowing users to start quickly and expand functionality as needed.

- Comprehensive Sample Programs:
Practical examples such as “Easy Input,” “Using Trigger,” and “Consecutive Sampling” are provided to demonstrate analog input and other operations, facilitating faster development and debugging.

- Multi-Device Support:
Supports a wide range of CONTEC boards including analog input/output, digital I/O, counter/timer, motor control, serial communication, and GPIB interface cards.

- Cross-Language API Support:
In addition to LabVIEW, the driver suite supports Microsoft Visual Basic, Visual C++, Visual C#.NET, Visual Basic.NET, and Borland C++ Builder and Delphi, enabling hybrid development environments.

- Integrated Diagnostic and Configuration Tools:
Includes setup and diagnostic utilities for hardware configuration, IEEE488.2 parameter setup, and functional verification.

- Free Distribution and Updates:
The API-PAC(W32) and related driver libraries are provided free of charge, with updates and sample programs available for download from CONTEC’s global portal.




3. Technical Specifications

- Supported Operating Systems:
- Windows XP Professional / Home Edition
- Windows 2000 Professional
- Windows NT Workstation 4.0 (SP3 or later)
- Windows Me / 98SE / 98 / 95

- Supported LabVIEW Versions:
- LabVIEW 7.1 / 7.0 / 6.1 / 6i

- Supported Programming Languages:
- Microsoft Visual Basic 6.0 / 5.0 / 4.0
- Microsoft Visual C++ 6.0 / 5.0 / 4.x / 2.0
- Visual Basic .NET 2003 / 2002
- Visual C++ .NET 2003 / 2002
- Visual C# .NET 2003 / 2002
- Borland C++ Builder 6.0 / 5.0
- Borland Delphi 6.0 / 5.0 / 4.0

- Supported Hardware Interfaces:
- Analog I/O: ADA16-32/2(PCI)F, AD12-16U(PCI)EH, DA12-8(PCI), etc.
- Digital I/O: PI-64L(PCI), PIO-32/32L(PCI), PIO-48D(PCI), etc.
- Counter Input: CNT24-4(PCI), CNT32-8M(PCI), CNT32-4MT(CB)
- Motor Control: SMC-2P(PCI), SMC-4P(PCI), SMC-3(PC)
- GPIB Communication: GP-IB(PCI)F, GP-IB(LPCI)F, GP-IB(CPCI)F, GP-IB(CB)F, GP-IB(PM)
- Serial Communication: COM-1(LPCI)H, COM-4(PCI)H, COM-8(PCI)H, COM-2(PM), etc.

- Library Components:
- VI-DAQ (LabVIEW VI library for data acquisition)
- API-GPLV(W32) (LabVIEW-compliant GPIB driver)
- COM-DRV(W32) (Standard COM driver for serial communication)
- API-PAC(W32) (Unified Win32 API driver library)
- API-AIO(WDM) (High-performance analog I/O library)
- API-DIO, API-CNT, API-SMC, API-TIMER (Dedicated libraries for digital I/O, counter, motor, and timer control)

- Distribution Format:
- Windows DLL-based driver libraries
- Setup executable with configuration utilities
- Sample programs and documentation included




4. Functionality

The VI-Driver-WIN enables LabVIEW users to directly access and control CONTEC’s hardware modules through a set of pre-built Virtual Instruments (VIs). These VIs encapsulate low-level driver functions, allowing users to perform analog and digital I/O, counter operations, and communication tasks without manual coding of device-level commands.

Use Cases and Applications:
- Laboratory data acquisition and measurement systems
- Industrial automation and process control
- Equipment monitoring and diagnostics
- Embedded system prototyping using CONTEC I/O boards
- GPIB-based instrument control within LabVIEW environments
- Serial communication and remote device management

Compatibility:
- Compatible with CONTEC’s PCI, CompactPCI, ISA, and PC Card hardware families.
- Can coexist with other CONTEC API-PAC(W32) libraries for mixed I/O systems.
- Not compatible with National Instruments’ GPIB drivers or CONTEC’s legacy API-GPIB(98/PC) library when used simultaneously on the same hardware.




5. Components & Accessories

Included Items:
- VI-Driver-WIN installation package (CD-ROM or downloadable installer)
- VI-DAQ library for LabVIEW
- API-GPLV(W32) GPIB driver
- COM-DRV(W32) serial communication driver
- API-PAC(W32) unified driver library
- Configuration and diagnostic utilities
- Sample VI programs and source code examples
- Documentation and help files

Optional Add-ons:
- Additional CONTEC hardware modules (analog, digital, counter, motor control)
- GPIB cables and connectors
- Serial communication accessories
- API-TOOL Developer’s Site access for latest driver updates

Connectors and Interfaces:
- Supports standard PCI, CompactPCI, ISA, and PC Card interfaces
- GPIB IEEE-488.2 compliant connectors
- RS-232C serial communication ports




6. Installation & Setup

System Requirements:
- Windows XP/2000/NT/Me/98/95 operating system
- LabVIEW 6i or later installed
- Compatible CONTEC hardware installed and recognized by Windows Device Manager

Installation Procedure:
1. Run the setup program included with the VI-Driver-WIN package.
2. Select the CONTEC board(s) to be used.
3. The installer automatically registers the appropriate DLLs and configuration files.
4. Use the included configuration utility to set hardware parameters (e.g., IEEE488.2 settings for GPIB boards).
5. Verify installation using the diagnostic utility to ensure proper communication between software and hardware.

Configuration Tools:
- API-TOOL Configuration Utility: Detects installed boards and allows logical device registration.
- Diagnostic Program: Performs functional checks and generates status reports.
- Setup Wizard: Guides users through initial configuration of analog, digital, and communication boards.




7. Performance & Capabilities

- Analog I/O:
Up to 64 channels controllable; supports internal/external sampling clocks, trigger-based acquisition, and simultaneous monitoring of multiple interrupt conditions.

- Digital I/O:
Up to 64 channels controllable; supports bit-level I/O, hardware digital filtering, and chattering prevention.

- Counter Input:
Up to 16 boards controllable; supports preset values, event generation, and one-shot pulse output.

- Motor Control:
Supports multi-axis control, PTP motion, jogging, and synchronized interpolation across multiple axes.

- Serial Communication:
Up to 256 channels controllable; supports XON/XOFF flow control, adjustable buffer sizes (256–65535 bytes), and event-driven communication.

- GPIB Communication:
IEEE-488.2 compliant; supports master/slave mode selection, DMA/FIFO transfer, and 3-line handshaking for reliable data exchange.

- Timer Control:
Provides microsecond-level timing precision; includes ActiveX control for easy integration into Visual Basic and LabVIEW environments.

Limitations:
- Cannot be used simultaneously with National Instruments’ GPIB drivers.
- Some legacy ISA boards may not support automatic detection under Windows NT 4.0/3.51.




8. Standards & Compliance

- IEEE-488 / IEEE-488.2: Compliance for GPIB communication boards.
- Windows Hardware Compatibility: Fully compliant with Microsoft Windows driver model (WDM).
- LabVIEW Integration: Designed according to National Instruments’ LabVIEW VI architecture standards.
- Plug and Play (PnP): Supported for PCI and CompactPCI boards.
- Regulatory Compliance: Meets industrial automation and measurement software standards for reliability and interoperability.




9. Additional Information

Warranty & Support:
- Provided by CONTEC Co., Ltd. under standard software warranty terms.
- Technical support available through CONTEC’s global portal and regional offices.
- Diagnostic and configuration utilities included to assist in troubleshooting.

Maintenance & Updates:
- Free software updates and driver library downloads available at:
- [http://www.contec.com/vidaq/](http://www.contec.com/vidaq/)
- [http://www.contec.com/gplv/](http://www.contec.com/gplv/)
- [http://www.contec.com/apipac/](http://www.contec.com/apipac/)
- API-PAC(W32) and related libraries are continuously updated to support new hardware and operating systems.

Documentation & Resources:
- Comprehensive help files and HTML-based function references.
- Sample programs for LabVIEW, Visual Basic, C/C++, and .NET environments.
- API-TOOL Developer’s Site provides access to the latest driver versions and development resources.

Summary:
The VI-Driver-WIN is a robust, LabVIEW-compliant driver solution that bridges CONTEC’s extensive hardware portfolio with National Instruments’ LabVIEW environment. It simplifies system integration, accelerates development, and ensures reliable operation across a wide range of industrial and laboratory applications. With its modular architecture, unified API, and comprehensive support for analog, digital, counter, motor, serial, and GPIB interfaces, VI-Driver-WIN stands as a versatile and essential tool for engineers developing measurement and control systems on Windows platforms.

Keine Manuals/Kataloge verfügbar.

Kein Zubehör vorhanden.