SUCHEN SIE DIE PASSENDE

INDUSTRIELLE LÖSUNG?

Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.

W-M1B107

8*DI AD V/thermo RS485 Modbus module
172,00 EUR

inkl. Umsatzsteuer 204,68 EUR

  • Hersteller Advanio
  • Kategorie: Ethernet / USB / RS485 / RS232 Modbus IO
  • The W‑M1B107 is an industrial‑grade, isolated, 8‑channel thermocouple input module designed for remote data acquisition and process control applications. It belongs to Advanio’s Wolf Series of RS‑485 Modbus/RTU I/O modules, engineered for high reliability, modular scalability, and ease of integration in distributed control systems. The module supports multiple thermocouple types (J, K, T, E, R, S, B, N), features 16‑bit resolution, and provides robust isolation and protection for harsh industrial environments.
- Universal Thermocouple Input: Supports J, K, T, E, R, S, B, and N thermocouple types for wide‑range temperature measurement.
- High‑Resolution Conversion: 16‑bit A/D resolution with 2.5 samples per second per channel ensures precise analog‑to‑digital conversion.
- Cold Junction Compensation (CJC): Integrated thermal sensor for automatic cold junction compensation, configurable via Modbus registers.
- Channel Independence: Each of the 8 channels can be configured independently for different thermocouple types.
- Burn‑Out Detection: Detects open‑circuit or sensor disconnection conditions to prevent false readings or unsafe operations.
- High Isolation: 3000 VDC isolation between power, communication, and I/O circuits for noise immunity and safety.
- Wide Power Input Range: Operates from +10 VDC to +60 VDC with reverse polarity protection; ripple peak ≤ 5 V.
- Compact Design: Slim 47.2 mm vertical housing for space‑constrained installations such as control panels or distribution boxes.
- Hot‑Swap Capability: Modules can be replaced without rewiring; configuration stored in removable EEPROM for quick recovery.
- Easy Address Configuration: Modbus node address set via dual rotary switches (1–247).
- LED Diagnostics: Three front‑panel LEDs indicate power, communication, and system status for quick on‑site troubleshooting.
- Programmable Safety Values: User‑defined power‑on and fail‑safe output states to ensure controlled behavior during faults.
- Industrial‑Grade Reliability: Designed for continuous operation in ‑25 °C to +70 °C environments with built‑in watchdog timers.
- Modbus/RTU Communication: Standard RS‑485 interface supporting baud rates from 1200 bps to 115.2 kbps, up to 1.2 km communication distance.
- EMC Compliance: Tested for EMI/EMS immunity; CE and FCC Part 15 compliant.
- 5‑Year Warranty: Long‑term reliability backed by Advanio’s extended warranty program.

Ursprungsland: Taiwan R.O.C.

Zolltarifnummer: 8473 3020 000

Comprehensive Product Summary – Advanio W‑M1B107 8‑Channel Thermocouple RS‑485 Modbus Module




### 1. Product Overview

Product Name: 8‑Channel Differential Analog Input / Thermocouple RS‑485 Modbus Module
Model Number: W‑M1B107
Series: Wolf Series RS‑485 Remote I/O Modules
Article Number: W‑M1B107
Manufacturer: Advanio Technology Co., Ltd.

The W‑M1B107 is an industrial‑grade, isolated, 8‑channel thermocouple input module designed for remote data acquisition and process control applications. It belongs to Advanio’s Wolf Series of RS‑485 Modbus/RTU I/O modules, engineered for high reliability, modular scalability, and ease of integration in distributed control systems. The module supports multiple thermocouple types (J, K, T, E, R, S, B, N), features 16‑bit resolution, and provides robust isolation and protection for harsh industrial environments.




### 2. Key Features

- Universal Thermocouple Input: Supports J, K, T, E, R, S, B, and N thermocouple types for wide‑range temperature measurement.
- High‑Resolution Conversion: 16‑bit A/D resolution with 2.5 samples per second per channel ensures precise analog‑to‑digital conversion.
- Cold Junction Compensation (CJC): Integrated thermal sensor for automatic cold junction compensation, configurable via Modbus registers.
- Channel Independence: Each of the 8 channels can be configured independently for different thermocouple types.
- Burn‑Out Detection: Detects open‑circuit or sensor disconnection conditions to prevent false readings or unsafe operations.
- High Isolation: 3000 VDC isolation between power, communication, and I/O circuits for noise immunity and safety.
- Wide Power Input Range: Operates from +10 VDC to +60 VDC with reverse polarity protection; ripple peak ≤ 5 V.
- Compact Design: Slim 47.2 mm vertical housing for space‑constrained installations such as control panels or distribution boxes.
- Hot‑Swap Capability: Modules can be replaced without rewiring; configuration stored in removable EEPROM for quick recovery.
- Easy Address Configuration: Modbus node address set via dual rotary switches (1–247).
- LED Diagnostics: Three front‑panel LEDs indicate power, communication, and system status for quick on‑site troubleshooting.
- Programmable Safety Values: User‑defined power‑on and fail‑safe output states to ensure controlled behavior during faults.
- Industrial‑Grade Reliability: Designed for continuous operation in ‑25 °C to +70 °C environments with built‑in watchdog timers.
- Modbus/RTU Communication: Standard RS‑485 interface supporting baud rates from 1200 bps to 115.2 kbps, up to 1.2 km communication distance.
- EMC Compliance: Tested for EMI/EMS immunity; CE and FCC Part 15 compliant.
- 5‑Year Warranty: Long‑term reliability backed by Advanio’s extended warranty program.




### 3. Technical Specifications

| Parameter | Specification |
|----------------|------------------|
| Input Channels | 8 differential analog input channels |
| Input Type | Thermocouple: J, K, T, E, R, S, B, N |
| Resolution | 16 bits |
| Sampling Rate | 2.5 samples/sec per channel |
| Accuracy | ± 0.1 % FSR |
| Input Impedance | 2 MΩ |
| Input Voltage Protection | ± 35 V |
| Common‑Mode Voltage | 2.5 V |
| Cold Junction Compensation | Built‑in thermal sensor, range –20 °C to +20 °C, 0.1 °C units |
| Isolation Voltage | 3000 VDC (power, communication, and I/O) |
| Power Supply | +10 VDC to +60 VDC (reverse polarity protected) |
| Power Consumption | 1.6 W @ 24 VDC |
| Communication Interface | RS‑485, Modbus/RTU protocol |
| Baud Rate | 1200 bps – 115.2 kbps |
| Communication Distance | Up to 1.2 km |
| Connectors | Plug‑in terminal blocks (#16–30 AWG) |
| Operating Temperature | –25 °C to +70 °C |
| Storage Temperature | –30 °C to +75 °C |
| Humidity | 5 % – 95 % RH (non‑condensing) |
| Dimensions | Width 47.2 mm (slim vertical mount) |
| Mounting | DIN‑rail 35 mm or wall‑mount |
| Weight | Approx. 115 g |
| Housing Material | Industrial‑grade ABS/PC plastic |
| Protection | Over‑voltage, reverse polarity, channel‑to‑channel isolation 240 V |
| Watchdog Timers | Hardware (1.6 s fixed) and software (programmable) |
| Compliance | CE, FCC Part 15, EMC (EMI/EMS) tested |




### 4. Functionality

The W‑M1B107 functions as a remote analog input module that digitizes thermocouple signals and transmits temperature data to a host controller (PLC, PAC, or SCADA system) via RS‑485 using the Modbus/RTU protocol. Each channel operates independently, allowing simultaneous measurement of different thermocouple types. The built‑in cold junction sensor compensates for terminal temperature variations, ensuring accurate readings.

Typical Applications:
- Industrial process temperature monitoring
- Energy management and environmental control
- Building automation and HVAC systems
- Laboratory instrumentation and test benches
- Supervisory control and data acquisition (SCADA)
- Factory automation and production line monitoring
- Power plant and substation temperature sensing

Compatibility:
Fully compatible with standard Modbus/RTU masters, PLCs, DCS, and SCADA software. Works with Advanio’s configuration utility and third‑party Modbus tools.




### 5. Components & Accessories

Included Items:
- W‑M1B107 module
- Detachable DIN‑rail mounting base (fixed seat)
- 14‑pin plug‑in terminal block for I/O connections
- Plastic grounding tab and isolation tab
- Quick start guide

Optional Accessories:
- RS‑232 ↔ RS‑485 isolated converter (Model G‑M1E001)
- USB ↔ RS‑485 converter (Model G‑M1A001)
- RS‑485 ↔ RS‑485 repeater (Model G‑M1F001)
- EEPROM replacement module for configuration backup

Connectors:
- Power input: +VS, GND, Frame Ground (F.G.)
- RS‑485 port: D+, D–
- I/O terminals: IN0 – IN7 (+/– pairs)




### 6. Installation & Setup

Mounting Options:
- DIN‑Rail 35 mm: Snap the detachable base onto the rail; modules can be docked side‑by‑side using the 14‑pin connector array for power and communication bus continuity.
- Wall Mount: Secure the base with screws using the provided mounting holes.

Grounding:
For aluminum DIN‑rail installations, the rail serves as frame ground. If electrical noise or poor grounding is present, use the provided plastic isolation tab to decouple the module frame from the rail.

Power Wiring:
Connect +VS (10–60 VDC) and GND to the power terminals. Keep cable length short to minimize voltage drop. Only one power source should feed a chain of up to 10 modules (≈ 30 W total).

Communication Wiring:
RS‑485 differential pair (D+, D–) connects in daisy‑chain topology. The first and last nodes should be terminated with 120 Ω resistors. Intermediate modules should not be tapped for signal pickup to avoid reflections.

Address Configuration:
Two rotary switches on the front panel set the Modbus node address (01–247). Power must be cycled after changing the address.

LED Indicators:
- Power LED: Steady ON = power OK; flashes 3× at startup = initialization complete.
- Communication LED: Flashes = active data exchange; steady ON = polling timeout.
- System LED: Flashing = normal operation; steady ON = error or EEPROM fault.

Factory Reset:
Press and hold the INIT push‑button for 3 seconds to restore default settings (address 01, 9600 bps, N‑8‑1).

Software Configuration:
Use Advanio’s PC utility via RS‑485 or converter to set channel types, CJC offsets, and scaling. Configuration parameters are stored in non‑volatile EEPROM.




### 7. Performance & Capabilities

- Measurement Range (per thermocouple type):
- Type J: –210 °C to +1200 °C
- Type K: –270 °C to +1372 °C
- Type T: –270 °C to +400 °C
- Type E: –270 °C to +1000 °C
- Type R/S: –50 °C to +1768 °C
- Type B: 0 °C to +1820 °C
- Type N: –270 °C to +1300 °C

- Data Format: Selectable hexadecimal (two’s complement) or engineering units (0.1 °C resolution).
- Noise Rejection: 120 dB CMR and 100 dB NMR at 50/60 Hz.
- Drift: Span ± 25 ppm/°C; Zero ± 6 µV/°C.
- Input Protection: ± 35 V continuous; channel‑to‑channel isolation 240 V.
- Watchdog Recovery: Hardware watchdog resets module after 1.6 s of fault; software watchdog configurable via Modbus registers 44108–44110.
- Communication Distance: Up to 1.2 km (4000 ft) without repeater; extendable to 247 nodes with repeaters.
- Hot‑Swap Operation: EEPROM retains configuration; swapping modules restores settings automatically.
- Power Efficiency: 1.6 W @ 24 VDC typical, low heat dissipation.

Limitations:
- Sampling rate limited to 2.5 Hz per channel (suited for slow‑changing temperature signals).
- Not intended for high‑speed transient capture.
- Requires proper shielded cabling and grounding for optimal EMC performance.




### 8. Standards & Compliance

- Electrical Safety: 3 kVDC isolation tested between I/O, power, and communication.
- EMC Compliance: Designed and tested for EMI/EMS immunity per industrial standards.
- CE Certification: Meets European EMC Directive requirements when installed in CE‑certified industrial chassis.
- FCC Compliance: Conforms to FCC Part 15 Class A rules for industrial digital devices.
- Environmental Protection: Operating temperature –25 °C to +70 °C; humidity 5–95 % RH.
- Quality Assurance: Manufactured under Advanio’s rigorous validation and verification procedures for industrial reliability.




### 9. Additional Information

Warranty:
5‑year limited warranty from date of purchase. Covers manufacturing defects and component failures under normal operation. Excludes damage from misuse, improper installation, or unauthorized modification.

Support & Service:
- Technical support via email (service@advanio.com.tw) or website (www.advanio.com.tw).
- RMA procedure available for repairs or replacements.
- Firmware updates and configuration utilities downloadable from Advanio’s official site.

Maintenance:
- Periodically inspect terminal connections for tightness and corrosion.
- Keep ventilation openings clear to avoid overheating.
- Use anti‑static precautions when handling EEPROM or module electronics.

Software Tools:
- Advanio Utility for Windows: Configures channel types, CJC offsets, baud rates, and watchdog settings.
- Mobile App (Advanio for iOS/Android): Provides remote access to product information and support resources.

Manufacturer Profile:
Advanio Technology Co., Ltd. specializes in advanced I/O and data acquisition solutions for Industry 4.0 and IoT applications. Founded by automation and embedded system experts with over 20 years of field experience, Advanio develops robust RS‑485, CAN, Ethernet, EtherCAT, and wireless I/O modules for smart factory integration. The Wolf Series embodies Advanio’s commitment to reliability, serviceability, and ease of deployment in rugged industrial environments.




### Summary

The Advanio W‑M1B107 is a compact, high‑precision, and robust thermocouple input module engineered for industrial temperature monitoring and control. With its 8 independent channels, 16‑bit resolution, and comprehensive isolation and protection features, it delivers accurate and reliable data acquisition over RS‑485 Modbus networks. Its hot‑swappable design, EEPROM configuration backup, and wide power input range make it ideal for distributed automation systems requiring minimal downtime and maximum flexibility. Certified for EMC and FCC compliance and backed by a 5‑year warranty, the W‑M1B107 embodies Advanio’s industrial quality and commitment to Industry 4.0 connectivity.

Kein Zubehör vorhanden.