SUCHEN SIE DIE PASSENDE

INDUSTRIELLE LÖSUNG?

Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.

W-M2B301

8*DI Dry/Wet RS485 Modbus mini module
97,00 EUR

inkl. Umsatzsteuer 115,43 EUR

  • Hersteller Advanio
  • Kategorie: Ethernet / USB / RS485 / RS232 Modbus IO
  • The W‑M2B301 is a compact, high‑reliability digital input module designed for industrial automation and remote data acquisition applications. It belongs to Advanio’s Wolf Series of RS‑485 Modbus/RTU I/O modules, engineered for rugged environments and optimized for Industry 4.0 and IoT‑driven smart factory systems. The module provides eight isolated digital input channels configurable for either dry‑contact or wet‑contact operation, with advanced features such as signal latching, pulse counting, and programmable logic inversion.
- 8 Isolated Digital Inputs: Each channel supports both dry‑contact and wet‑contact modes, selectable per application.
- Dry/Wet Configurable Logic:
- *Dry contact:* Logic 0 = open, Logic 1 = closed to GND.
- *Wet contact:* Logic 0 = ≤ 3 V, Logic 1 = 10 – 50 V DC.
- Input Isolation: 2.5 kV DC isolation between channels and logic circuitry for noise immunity and safety.
- DI Latch Function: Captures transient input pulses ≥ 5 ms to ensure reliable detection of short‑duration events.
- DI Counter Function: 16‑bit hardware counter per channel, up to 100 Hz max frequency.
- Normal/Inverted Logic Selection: Each input can be configured as normal or inverted to simplify system integration or replacement of legacy modules.
- Hot‑Swap and Auto‑Configuration: Modules can be replaced without rewiring; configuration parameters are stored in a removable EEPROM for quick transfer.
- Rotary Switch Addressing: Two hexadecimal rotary switches allow fast Modbus node address setup (1 – 247).
- Wide Power Supply Range: Operates from +10 V DC to +60 V DC (ripple ≤ 5 V p‑p).
- Compact Form Factor: 20 mm slim housing, 100 × 95 mm footprint, optimized for DIN‑rail or wall mounting.
- LED Diagnostics: Three front LEDs indicate power, communication, and system status for rapid on‑site troubleshooting.
- Programmable Power‑On and Safety States: Ensures controlled startup and fail‑safe behavior under watchdog timeout or communication loss.
- Industrial‑Grade Reliability: Built‑in hardware and software watchdogs, EMC‑tested design, and operation from –25 °C to +70 °C.
- Modbus/RTU Protocol: Fully compatible with standard Modbus masters (PLC, PAC, SCADA, HMI, PC).
- Cost‑Effective, Space‑Saving Design: High channel density and vertical orientation allow 1.5× more modules per panel compared with conventional flat I/O devices.

Ursprungsland: Taiwan R.O.C.

Zolltarifnummer: 8473 3020 000

Comprehensive Product Summary – Advanio W‑M2B301 RS‑485 Modbus Mini Module




### 1. Product Overview

Product Name: 8‑Channel Isolated Dry/Wet Digital Input Module
Model: W‑M2B301
Series: Wolf Series RS‑485 Remote I/O Modules
Article Number: W‑M2B301
Manufacturer: Advanio Technology Co., Ltd.

The W‑M2B301 is a compact, high‑reliability digital input module designed for industrial automation and remote data acquisition applications. It belongs to Advanio’s Wolf Series of RS‑485 Modbus/RTU I/O modules, engineered for rugged environments and optimized for Industry 4.0 and IoT‑driven smart factory systems. The module provides eight isolated digital input channels configurable for either dry‑contact or wet‑contact operation, with advanced features such as signal latching, pulse counting, and programmable logic inversion.

Advanio Technology Co., Ltd., headquartered in Taiwan, specializes in advanced industrial I/O and embedded automation solutions. Founded by a team of IoT and automation experts with over two decades of field experience, Advanio’s mission is to deliver robust, serviceable, and intelligent I/O systems that meet the demands of modern industrial connectivity.




### 2. Key Features

- 8 Isolated Digital Inputs: Each channel supports both dry‑contact and wet‑contact modes, selectable per application.
- Dry/Wet Configurable Logic:
- *Dry contact:* Logic 0 = open, Logic 1 = closed to GND.
- *Wet contact:* Logic 0 = ≤ 3 V, Logic 1 = 10 – 50 V DC.
- Input Isolation: 2.5 kV DC isolation between channels and logic circuitry for noise immunity and safety.
- DI Latch Function: Captures transient input pulses ≥ 5 ms to ensure reliable detection of short‑duration events.
- DI Counter Function: 16‑bit hardware counter per channel, up to 100 Hz max frequency.
- Normal/Inverted Logic Selection: Each input can be configured as normal or inverted to simplify system integration or replacement of legacy modules.
- Hot‑Swap and Auto‑Configuration: Modules can be replaced without rewiring; configuration parameters are stored in a removable EEPROM for quick transfer.
- Rotary Switch Addressing: Two hexadecimal rotary switches allow fast Modbus node address setup (1 – 247).
- Wide Power Supply Range: Operates from +10 V DC to +60 V DC (ripple ≤ 5 V p‑p).
- Compact Form Factor: 20 mm slim housing, 100 × 95 mm footprint, optimized for DIN‑rail or wall mounting.
- LED Diagnostics: Three front LEDs indicate power, communication, and system status for rapid on‑site troubleshooting.
- Programmable Power‑On and Safety States: Ensures controlled startup and fail‑safe behavior under watchdog timeout or communication loss.
- Industrial‑Grade Reliability: Built‑in hardware and software watchdogs, EMC‑tested design, and operation from –25 °C to +70 °C.
- Modbus/RTU Protocol: Fully compatible with standard Modbus masters (PLC, PAC, SCADA, HMI, PC).
- Cost‑Effective, Space‑Saving Design: High channel density and vertical orientation allow 1.5× more modules per panel compared with conventional flat I/O devices.




### 3. Technical Specifications

| Parameter | Specification |
|----------------|------------------|
| Digital Inputs | 8 channels, isolated dry/wet selectable |
| Logic Levels (Dry) | Logic 0 = open; Logic 1 = closed to GND |
| Logic Levels (Wet) | Logic 0 ≤ 3 V DC; Logic 1 = 10 – 50 V DC |
| Input Resistance | 10 kΩ |
| Isolation Voltage | 2.5 kV DC (channel to logic) |
| Over‑Voltage Protection | ± 70 V DC |
| Counter Frequency | ≤ 100 Hz (max), 16‑bit |
| Latch Detection | ≥ 5 ms pulse width |
| Power Supply | +10 V DC to +60 V DC (ripple ≤ 5 V p‑p) |
| Power Consumption | 1.6 W @ 24 V DC |
| Communication Interface | RS‑485 2‑wire, Modbus/RTU |
| Baud Rate | 1200 – 115.2 kbps, programmable |
| Communication Distance | Up to 1.2 km (4000 ft) |
| Connectors | Plug‑in terminal blocks (#16 – 30 AWG) |
| Indicators | Power, Communication, System LEDs |
| Isolation Protection | Power, I/O, and communication isolated |
| Operating Temperature | –25 °C to +70 °C |
| Storage Temperature | –30 °C to +75 °C |
| Humidity | 5 – 95 % RH (non‑condensing) |
| Dimensions | 100 mm (L) × 95 mm (H) × 20 mm (W) |
| Mounting | DIN‑rail (35 mm) or wall mount |
| Weight | Approx. < 200 g (module only) |
| Housing Material | Industrial ABS/PC flame‑retardant plastic |
| Isolation Category | 3000 V DC system isolation rating |
| Protection | Reverse power protection, EMI/EMS shielding |




### 4. Functionality

Operating Principle:
The W‑M2B301 functions as a remote digital input node on an RS‑485 Modbus/RTU network. A host controller (PLC, PAC, or PC) polls the module using Modbus commands to read input states, counters, or latch registers. Each input channel can detect either contact closures (dry mode) or voltage signals (wet mode). The module’s microcontroller debounces and filters input transitions, ensuring reliable detection even in electrically noisy environments.

Use Cases and Applications:
- Industrial process monitoring and control
- Machine status and alarm input collection
- Energy management and power distribution monitoring
- Building automation and security systems
- Laboratory and test automation
- Remote telemetry and SCADA data acquisition
- Direct digital control (DDC) and facility management systems

Compatibility:
Fully compatible with standard Modbus/RTU masters and software platforms such as SCADA, LabVIEW, Ignition, Citect, and custom PLC programs. The module can coexist with other Wolf‑series analog or digital modules on the same RS‑485 bus.




### 5. Components & Accessories

Included Items:
- W‑M2B301 module
- Detachable 14‑pin terminal block for I/O wiring
- DIN‑rail mounting base (fixed seat)
- Plastic isolation tab and buckle set
- Quick‑start guide

Optional Accessories:
- RS‑232 ↔ RS‑485 isolated converter (model G‑M1A001)
- USB ↔ RS‑485 converter (model G‑M1E001)
- RS‑485 ↔ RS‑485 repeater (model G‑M1F001)
- EEPROM replacement module for configuration backup

Connectors:
- Power input: 2‑pin terminal (+VS, GND)
- RS‑485 port: 2‑pin terminal (D+, D–)
- I/O connector: 14‑pin plug‑in terminal block




### 6. Installation & Setup

Requirements:
- DC power supply 10 – 60 V DC (24 V nominal)
- RS‑485 network cabling (twisted pair, shielded)
- Host PC or controller with RS‑485 port or converter

Mounting Options:
- DIN‑Rail Mounting: Attach the detachable base to a 35 mm DIN rail; modules can be docked side‑by‑side using the 14‑pin bus connector for power and communication distribution.
- Wall Mounting: Use the base’s screw holes for panel installation when DIN rails are not available.

Grounding:
Connect frame ground (F.G.) to a proper earth point or DIN rail ground tab to ensure EMC stability. If ground noise is present, use the provided plastic isolation tab to decouple frame ground from the rail.

Power Wiring:
Connect +VS and GND to the power supply. Modules on the same rail share power and communication through the base connector (≤ 10 modules per rail, ≈ 30 W total).

Communication Setup:
- Default baud rate: 9600 bps, N, 8, 1
- Address range: 1 – 247 (0x01 – 0xF7) set by rotary switches
- Supported baud rates: 1200, 2400, 4800, 9600, 19.2 k, 38.4 k, 57.6 k, 115.2 k bps
- Protocol: Modbus/RTU over RS‑485 (two‑wire half‑duplex)

Indicators:
- Power LED: ON = power OK; flashes 3× at startup = initialization complete.
- Communication LED: Flashing = active data exchange; steady ON = polling timeout.
- System LED: Flashing = normal operation; steady ON = error or EEPROM mismatch.

Factory Reset:
Press the INIT button for ≥ 3 seconds to restore defaults (baud 9600 bps, N, 8, 1, address 01).




### 7. Performance & Capabilities

- Input Response Time: ≤ 5 ms for latched signals.
- Counter Resolution: 16 bits per channel (0 – 65,535 counts).
- Counter Frequency: ≤ 100 Hz for low‑speed pulse inputs.
- Communication Latency: Deterministic Modbus response within typical 10 ms at 9600 bps.
- Power Efficiency: 1.6 W @ 24 V DC (≈ 67 mA).
- Hot‑Swap Capability: EEPROM retains configuration for instant replacement without reprogramming.
- System Watchdog: Programmable timeout (0 – 25.5 s in 0.1 s steps); forces safe state on timeout.
- Module Watchdog: Hardware reset after 1.6 s of internal fault detection.
- Network Capacity: Up to 32 modules per RS‑485 segment (247 max with repeaters).
- Communication Distance: Up to 1.2 km (4000 ft) per segment with twisted‑pair cable.
- Reliability: Designed for continuous operation in harsh industrial environments with EMI/EMS protection and reverse polarity safeguards.

Limitations:
- Not intended for high‑frequency pulse counting (> 100 Hz).
- Requires proper termination and biasing on RS‑485 bus for stable communication.
- One power source per module chain recommended to avoid ground loops.




### 8. Standards & Compliance

- Communication Protocol: Modbus RTU (ANSI standard EIA/TIA‑485‑A)
- Isolation Protection: Up to 3 kV DC between power, I/O, and communication circuits
- EMC Compliance: Tested for EMI and EMS per industrial EMC standards
- CE Recommendation: Use with CE‑certified industrial chassis for full compliance
- FCC Compliance: Part 15 Class A device – (1) may not cause harmful interference; (2) must accept any interference received
- Environmental Protection: RoHS compliant, lead‑free construction
- Safety Design: Meets industrial low‑voltage and isolation requirements




### 9. Additional Information

Warranty: 5 years from date of purchase.
Advanio provides free repair or replacement for manufacturing defects within the warranty period. Damage caused by improper installation, modification, or misuse is excluded. Out‑of‑warranty service is available at nominal cost.

Support & Service:
- Email: service@advanio.com.tw
- Website: [https://www.advanio.com.tw](https://www.advanio.com.tw)
- RMA procedure available for returns and repairs with tracking number.

Maintenance:
- Periodically inspect terminal connections for tightness and corrosion.
- Keep ventilation openings free of dust.
- Avoid exposure to condensation or corrosive gases.
- Firmware updates and configuration utilities available via Advanio website.

Software Tools:
- ARIO Utility: Windows configuration software for Modbus parameter setup, address assignment, and I/O testing.
- Mobile Access: Advanio Cloud App (Android/iOS) for remote monitoring and support.

Manufacturer Profile:
Advanio Technology Co., Ltd. develops industrial I/O and embedded automation solutions for Industry 4.0 applications. Its Wolf Series modules cover analog input/output, digital input/output, relay output, and communication interfaces (RS‑485, CAN, Ethernet, EtherCAT, PROFINET, Modbus/TCP, Bluetooth, Wi‑Fi, 3G/4G). All products are engineered for high reliability, easy maintenance, and long‑term operation in industrial environments.




### Summary

The Advanio W‑M2B301 is a robust, compact, and versatile 8‑channel isolated digital input module designed for RS‑485 Modbus/RTU networks. It provides flexible dry/wet input configuration, advanced latch and counter functions, and comprehensive isolation protection. With its wide 10 – 60 V DC power range, hot‑swap EEPROM, and simple rotary address setup, the module ensures rapid deployment and minimal downtime. Its industrial‑grade design, EMC certification, and 5‑year warranty make it an ideal choice for smart factory, process control, and building automation systems requiring reliable digital signal acquisition in harsh environments.

Kein Zubehör vorhanden.