SUCHEN SIE DIE PASSENDE

INDUSTRIELLE LÖSUNG?

Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.

W-M2J301

8*DI Dry/Wet TCP Modbus PoE mini module
102,00 EUR

inkl. Umsatzsteuer 121,38 EUR

  • Hersteller Advanio
  • Kategorie: Ethernet / USB / RS485 / RS232 Modbus IO
  • Advanio’s Wolf Series represents a new generation of compact, rugged, and intelligent remote I/O modules designed for Industry 4.0 and IoT applications. The W‑M2J301 is a horizontally mounted, space‑saving Ethernet I/O device providing eight isolated digital inputs with flexible dry/wet contact configuration, Modbus/TCP communication, and Power over Ethernet (PoE) support. It is engineered for distributed data acquisition, process monitoring, and industrial automation control.
- 8 Isolated Digital Inputs: Configurable as dry (contact closure) or wet (voltage signal) inputs.
- Dry/Wet Selectable Mode: Supports both potential‑free contacts and voltage inputs (+10 to +50 V DC).
- DI Latch Function: Captures short‑duration signals ≥ 5 ms for reliable event detection.
- DI Counter Function: 16‑bit counter per channel, up to 100 Hz input frequency.
- Normal/Inverted Logic: Each channel can be set to normal or inverted logic for compatibility with existing systems.
- Hot‑Swap and Auto‑Configuration: Modules can be replaced without rewiring; EEPROM stores configuration for instant recovery.
- Non‑Volatile EEPROM Backup: Configuration parameters are retained and transferable between modules.
- Programmable Power‑On and Safety Values: Ensures safe system state on startup or communication failure.
- Isolation Protection: 2.5 kV galvanic isolation between I/O, power, and communication circuits.
- Wide Power Input Range: +10 to +60 V DC with ripple ≤ 5 V p‑p; PoE support for simplified wiring.
- Compact Form Factor: 100 × 95 mm footprint, 20 mm slim width for dense DIN‑rail installation.
- LED Diagnostics: Three status LEDs indicate power, communication, and system status for on‑site diagnosis.
- Easy Node Address Setting: Two rotary switches allow quick Modbus address assignment (1–247).
- High Reliability: Integrated module and system watchdogs for automatic recovery from faults.
- Industrial Grade Design: Operating temperature −25 to +70 °C; humidity 5–95 % RH; EMC tested for EMI/EMS immunity.
- Low Power Consumption: 1.6 W @ 24 V DC typical.
- Long Warranty: 5‑year manufacturer warranty for industrial applications.

Ursprungsland: Taiwan R.O.C.

Zolltarifnummer: 8473 3020 000

Comprehensive Product Summary – Advanio W‑M2J301 8‑Channel Digital Input TCP Modbus PoE Mini Module




### 1. Product Overview

Product Name: 8×DI Dry/Wet TCP Modbus PoE Mini Module
Model Number: W‑M2J301
Article Number: W‑M2J301
Series: Wolf Series Remote I/O Modules
Manufacturer: Advanio Technology Co., Ltd.
Mounting Type: Horizontal Mount (M2 designation)
Communication Type: Ethernet (Modbus/TCP over PoE)
I/O Type: Digital Input (DI) – 8 channels, Dry or Wet contact

Advanio’s Wolf Series represents a new generation of compact, rugged, and intelligent remote I/O modules designed for Industry 4.0 and IoT applications. The W‑M2J301 is a horizontally mounted, space‑saving Ethernet I/O device providing eight isolated digital inputs with flexible dry/wet contact configuration, Modbus/TCP communication, and Power over Ethernet (PoE) support. It is engineered for distributed data acquisition, process monitoring, and industrial automation control.




### 2. Key Features

- 8 Isolated Digital Inputs: Configurable as dry (contact closure) or wet (voltage signal) inputs.
- Dry/Wet Selectable Mode: Supports both potential‑free contacts and voltage inputs (+10 to +50 V DC).
- DI Latch Function: Captures short‑duration signals ≥ 5 ms for reliable event detection.
- DI Counter Function: 16‑bit counter per channel, up to 100 Hz input frequency.
- Normal/Inverted Logic: Each channel can be set to normal or inverted logic for compatibility with existing systems.
- Hot‑Swap and Auto‑Configuration: Modules can be replaced without rewiring; EEPROM stores configuration for instant recovery.
- Non‑Volatile EEPROM Backup: Configuration parameters are retained and transferable between modules.
- Programmable Power‑On and Safety Values: Ensures safe system state on startup or communication failure.
- Isolation Protection: 2.5 kV galvanic isolation between I/O, power, and communication circuits.
- Wide Power Input Range: +10 to +60 V DC with ripple ≤ 5 V p‑p; PoE support for simplified wiring.
- Compact Form Factor: 100 × 95 mm footprint, 20 mm slim width for dense DIN‑rail installation.
- LED Diagnostics: Three status LEDs indicate power, communication, and system status for on‑site diagnosis.
- Easy Node Address Setting: Two rotary switches allow quick Modbus address assignment (1–247).
- High Reliability: Integrated module and system watchdogs for automatic recovery from faults.
- Industrial Grade Design: Operating temperature −25 to +70 °C; humidity 5–95 % RH; EMC tested for EMI/EMS immunity.
- Low Power Consumption: 1.6 W @ 24 V DC typical.
- Long Warranty: 5‑year manufacturer warranty for industrial applications.




### 3. Technical Specifications

| Parameter | Specification |
|----------------|------------------|
| Digital Inputs | 8 channels, isolated, dry or wet contact selectable |
| Logic Levels (Dry) | Logic 0 = open contact; Logic 1 = closed to GND |
| Logic Levels (Wet) | Logic 0 ≤ +3 V DC; Logic 1 = +10 to +50 V DC |
| Input Resistance | 10 kΩ typical |
| Isolation Voltage | 2.5 kV DC channel‑to‑system |
| Over‑Voltage Protection | ±70 V DC max |
| Counter Frequency | ≤ 100 Hz (16‑bit counter per channel) |
| Latch Detection Time | ≥ 5 ms pulse width |
| Communication Interface | Ethernet (Modbus/TCP protocol) |
| Baud Rate Range | 1200 – 115.2 kbps (serial compatibility for gateway use) |
| Power Input | +10 to +60 V DC (unregulated), ripple ≤ 5 V p‑p or PoE IEEE 802.3af |
| Power Consumption | 1.6 W @ 24 V DC |
| Isolation Protection | 2.5 kV between I/O, power, and communication |
| Operating Temperature | −25 °C to +70 °C |
| Storage Temperature | −30 °C to +75 °C |
| Humidity | 5 % – 95 % RH (non‑condensing) |
| Dimensions | 100 mm (L) × 95 mm (H) × 20 mm (W) |
| Mounting | DIN‑rail 35 mm or wall mount via detachable base |
| Weight | Approx. < 200 g (module only) |
| Housing Material | Industrial ABS plastic with flame retardant rating |
| Ingress Protection | IP20 (indoor industrial use) |
| Indicators | 3 LEDs (Power, Communication, System) for status diagnosis |




### 4. Functionality

Operating Principle:
The W‑M2J301 acts as a remote digital input node on an Ethernet (Modbus/TCP) network. Each of its eight isolated channels monitors external switches, sensors, or logic signals and transmits their status to a host controller (PLC, PAC, SCADA, or industrial PC). The module supports both dry contact inputs for potential‑free switches and wet contact inputs for voltage signals up to 50 V DC. Captured data is communicated via Modbus/TCP frames over Ethernet or PoE networks.

Use Cases and Applications:
- Remote data acquisition and monitoring of digital signals.
- Industrial process control and machine status feedback.
- Energy management and power distribution monitoring.
- Building automation and HVAC control systems.
- Security and access control signal collection.
- Laboratory and test automation systems.
- Supervisory control and data logging applications.
- Integration with SCADA or PLC systems via Modbus/TCP.

Compatibility:
Fully compliant with Modbus/TCP standard for interoperability with most industrial controllers and software platforms (e.g., Siemens, Schneider, Beckhoff, Ignition, LabVIEW, etc.). Supports Advanio’s utility software for configuration and diagnostics.




### 5. Components & Accessories

Included in Package:
- W‑M2J301 module (main unit)
- Detachable DIN‑rail mounting base (fixed seat)
- 14‑pin plug‑in terminal block for I/O connection
- Plastic grounding tab and buckle set
- Quick Start Guide and safety instructions

Optional Accessories:
- RS‑232 to RS‑485 converter (G‑M1A001)
- USB to RS‑485 converter (G‑M1E001)
- RS‑485 repeater (G‑M1F001)
- Replacement EEPROM module for configuration backup
- Wall‑mount bracket kit

Connectors:
- Plug‑in terminal block (16–30 AWG wire range)
- RJ‑45 Ethernet port for Modbus/TCP and PoE input
- Power input terminals (+VS, GND, Frame Ground) for non‑PoE operation




### 6. Installation & Setup

Requirements:
- DC power supply 10–60 V DC or PoE switch/injector.
- Host controller or PC with Modbus/TCP client software.
- Ethernet cabling (Cat 5e or better).
- Proper grounding and EMC compliance environment.

Mounting Options:
- DIN‑Rail Mounting: Attach the detachable base to a standard DIN 35 mm rail; modules can be docked side‑by‑side using pin arrays for power and communication distribution.
- Wall Mounting: Secure the base to a flat surface using screws through pre‑drilled holes.
- Grounding: Connect frame ground via metal DIN rail or dedicated FG terminal to ensure system stability.

Configuration Procedure:
1. Connect power and Ethernet cables.
2. Set Modbus node address using two rotary switches (1–247).
3. Power on the module; LEDs indicate initialization status.
4. Use Advanio Utility software or Modbus commands to configure communication parameters (baud rate, parity, watchdog timeout, etc.).
5. Verify I/O status via LED indicators or software monitoring.
6. For replacement, transfer EEPROM from old module to new unit to restore settings instantly.

Factory Reset:
Press the INIT button for 3 seconds to restore default settings (9600 bps, N, 8, 1, address 01).




### 7. Performance & Capabilities

- Signal Acquisition Speed: Up to 100 Hz per channel for counter inputs.
- Response Time: < 5 ms for latched signal recognition.
- Communication Latency: Deterministic Modbus/TCP response with configurable delay (0–30 ms).
- Power Efficiency: Low consumption (1.6 W @ 24 V DC) enables dense multi‑module installations (up to 10 modules per rail segment).
- Reliability: Hardware and software watchdogs ensure automatic recovery from network or system faults.
- Safety Mode: Outputs and internal states reset to predefined safe values on communication timeout or power failure.
- Hot‑Swap Capability: Modules can be replaced without disconnecting field wiring; EEPROM retains configuration.
- Scalability: Supports multi‑node Ethernet topologies (star, daisy‑chain, or mixed) for up to 247 nodes per network segment with repeaters.

Limitations:
- Designed for low‑frequency digital signals (≤ 100 Hz); not suitable for high‑speed pulse counting.
- Indoor industrial use only (IP20 enclosure).
- Requires proper grounding to maintain EMC performance.




### 8. Standards & Compliance

- Communication Protocol: Modbus/TCP (Ethernet standard IEEE 802.3)
- Isolation and Safety: 2.5 kV galvanic isolation between I/O and logic circuits.
- EMC Compliance: Tested for EMI and EMS immunity per industrial EMC standards.
- CE Certification: Recommended installation with CE‑certified industrial chassis.
- FCC Compliance: Complies with Part 15 of FCC Rules:
1. Device may not cause harmful interference.
2. Device must accept any interference received.
- Environmental Standards: RoHS compliant; lead‑free manufacturing.
- Quality Assurance: Manufactured under rigorous validation and verification procedures for industrial reliability.




### 9. Additional Information

Warranty: 5 years from date of purchase. Covers manufacturing defects and component failures under normal operation. Excludes damage from improper installation or unauthorized modification.

Technical Support:
- Email: service@advanio.com.tw
- Website: [www.advanio.com.tw](http://www.advanio.com.tw)
- Response time: within 2 working days.

Maintenance:
- Periodic inspection of terminal tightness and ground connections.
- Keep module free from dust and moisture.
- Firmware updates available via Advanio Utility software.

Firmware and Configuration Backup:
- EEPROM stores all user parameters (non‑volatile).
- EEPROM can be transferred to replacement modules for instant restoration.

Service Procedure:
1. Collect model number, serial number, and firmware version.
2. Describe problem and environmental conditions.
3. Obtain RMA number from authorized dealer.
4. Return product with proof of purchase for repair or replacement.

Manufacturer Profile:
Advanio Technology Co., Ltd. is a Taiwan‑based industrial automation company founded by IoT and system integration experts with over 20 years of field experience. The company specializes in advanced I/O technologies for smart factories and Industry 4.0 applications, offering wired and wireless connectivity solutions (RS‑485, CAN, Ethernet, EtherCAT, PROFINET, Wi‑Fi, 4G, etc.). Advanio’s Wolf Series modules are designed for rugged industrial environments with emphasis on reliability, ease of maintenance, and space efficiency.




### Summary of Advantages

- Compact 20 mm slim profile saves panel space.
- Wide input voltage range and PoE support simplify power distribution.
- Hot‑swappable design minimizes downtime.
- EEPROM backup ensures configuration integrity.
- Programmable safe states enhance system safety.
- Robust isolation and EMC protection for harsh industrial sites.
- Long service life and 5‑year warranty reduce total cost of ownership.




In Summary:
The Advanio W‑M2J301 8×DI Dry/Wet TCP Modbus PoE Mini Module is a high‑performance, space‑efficient digital input device for industrial Ethernet networks. It combines rugged hardware design, flexible I/O configuration, and advanced diagnostic features to deliver reliable data acquisition in smart factory and automation environments. Its wide power range, PoE capability, and hot‑swap functionality make it ideal for distributed control systems requiring minimal maintenance and maximum uptime.

Kein Zubehör vorhanden.