LOOKING FOR THE RIGHT

INDUSTRIAL SOLUTION?

Discover embedded, communication and automation solutions tailored to your application.

DMS / strain gauge / Brückenverstärker

Signal Conditioning from Module Gesamtprogramm is a modular and universal system for signal conditioning. It includes a wide range of products for DMS, strain gauge and bridge amplifier applications. With this system, users can quickly and easily configure the most suitable signal conditioning solution for their specific requirements.

Products

9 products

No. Code Product Price Quantity
7.1.4.5 Brücke / DMS, 2,0mV/V (1000-fach), Ausgang ±5V MDDMS3801
Brücke / DMS, 2,0mV/V (1000-fach), Ausgang ±5V

- **High-Gain Amplification:** 1000× amplification factor for low-level bridge sensor signals (2.0 mV/V nominal input sensitivity). - **Standardized Output:** Provides a **±5 V analog output**, compatible with most industrial analog input modules, PLCs, and DAQ systems. - **Bridge Sensor Compatibility:** Optimized for **strain gauges, load cells, pressure transducers, and torque sensors** operating on a Wheatstone bridge principle. - **Precision Signal Conditioning:** Ensures accurate, stable, and linear signal conversion with minimal drift and noise. - **Robust Industrial Design:** Suitable for integration into measurement systems, test benches, and process control environments. - **High Input Sensitivity:** Designed for sensors with millivolt-level outputs, ensuring precise measurement even under low signal conditions. - **Excellent Linearity and Stability:** Maintains consistent performance across temperature and load variations. - **Wide Application Range:** Ideal for mechanical testing, weighing systems, structural monitoring, and automation control. - **Ease of Integration:** Standardized output voltage simplifies connection to existing analog measurement infrastructure. - **Reliable Power and Signal Isolation (if applicable):** Ensures signal integrity in electrically noisy environments.

Manufacturer: No category

Category: DMS / strain gauge / Brückenverstärker

Request a quote
7.1.4.5 Brücke / DMS, 2,5mV/V (800-fach), Ausgang ±5V MDDMS3802
Brücke / DMS, 2,5mV/V (800-fach), Ausgang ±5V

- **High-Gain Amplification:** 800× amplification factor for low-level bridge sensor signals (2.5 mV/V nominal input). - **Standardized Output:** ±5 V analog output compatible with most data acquisition and control systems. - **Bridge Sensor Compatibility:** Optimized for strain gauge and Wheatstone bridge configurations. - **Precision Signal Conditioning:** Ensures stable, low-noise signal conversion for high-resolution measurements. - **Robust Design:** Industrial-grade construction suitable for laboratory and field applications. - **Wide Application Range:** Ideal for force, pressure, torque, and weight measurement systems. - **Ease of Integration:** Standardized electrical interface and mechanical form factor for modular system integration. - **High Linearity and Stability:** Maintains consistent performance across temperature and load variations. - **Low Drift and Noise:** Designed for long-term stability and minimal signal distortion. - **Power Supply Compatibility:** Operates from standard DC supply voltages (typically ±15 V or 24 V DC, depending on configuration).

Manufacturer: No category

Category: DMS / strain gauge / Brückenverstärker

Request a quote
7.1.4.5 Brücke / DMS, 3,0mV/V (666-fach), Ausgang ±5V MDDMS3803
Brücke / DMS, 3,0mV/V (666-fach), Ausgang ±5V

- **High-Precision Bridge Amplifier:** Designed for strain gauge and bridge sensor applications requiring accurate signal amplification. - **Input Sensitivity:** 3.0 mV/V nominal, optimized for standard strain gauge sensors. - **Amplification Factor:** 666× gain, ensuring precise scaling of low-level sensor signals to a ±5 V output range. - **Standardized Output:** ±5 V analog output for direct interfacing with PLCs, DAQ systems, and analog input modules. - **Excellent Linearity and Stability:** Engineered for minimal drift and high repeatability across temperature and time. - **Wide Compatibility:** Supports full-bridge, half-bridge, and quarter-bridge configurations (depending on wiring and sensor type). - **Industrial-Grade Design:** Robust construction suitable for laboratory, industrial, and field measurement applications. - **Low Noise Performance:** Ensures clean signal transmission even in electrically noisy environments. - **Compact Modular Form Factor:** Facilitates integration into control cabinets, test benches, and measurement systems. - **Ease of Integration:** Standard connectors and voltage output simplify system design and reduce setup time.

Manufacturer: No category

Category: DMS / strain gauge / Brückenverstärker

Request a quote
7.1.4.5 Modul Brücke / DMS, 2,0mV/V, 500-fach MDDMS3810
Modul Brücke / DMS, 2,0mV/V, 500-fach

- **High‑Precision Bridge Amplifier:** Optimized for strain gauge and Wheatstone bridge sensors with nominal sensitivity of 2.0 mV/V. - **Fixed Gain Factor:** 500× amplification ensures consistent scaling of low‑level sensor signals to a ±5 V output range. - **Standardized Output Signal:** ±5 V analog output compatible with most industrial controllers, PLCs, and data acquisition systems. - **Stable Excitation and Signal Conditioning:** Provides regulated excitation voltage to the connected bridge sensor, ensuring measurement stability and repeatability. - **Low Noise and High Linearity:** Designed for precision measurement applications where signal integrity is critical. - **Compact Modular Design:** Suitable for DIN‑rail or panel mounting within control cabinets or instrumentation racks. - **Robust Industrial Construction:** Engineered for long‑term reliability in demanding environments such as production lines, test benches, and laboratory setups. - **Ease of Integration:** Standardized electrical interfaces simplify connection to sensors and downstream electronics. - **Wide Application Range:** Ideal for load cells, pressure transducers, torque sensors, and other bridge‑based measurement devices.

Manufacturer: No category

Category: DMS / strain gauge / Brückenverstärker

Request a quote
7.1.4.5 Modul Brücke / DMS, 2,5mV/V, 400-fach MDDMS3811
Modul Brücke / DMS, 2,5mV/V, 400-fach

- **High‑Precision Bridge Amplifier:** Designed for strain gauge and bridge sensor signals with nominal sensitivity of 2.5 mV/V. - **Amplification Factor:** Fixed gain of **400×**, ensuring accurate scaling of low‑level sensor outputs to standard voltage levels. - **Output Signal:** Differential or single‑ended **±5 V analog output**, compatible with most data acquisition and control systems. - **Signal Conditioning:** Provides stable, low‑noise amplification suitable for dynamic and static measurements. - **Bridge Excitation Compatibility:** Supports standard bridge configurations (full, half, or quarter bridge) depending on wiring and sensor type. - **Industrial‑Grade Design:** Built for robust operation in laboratory and industrial environments. - **Compact Modular Form Factor:** Designed for integration into modular measurement systems or DIN‑rail mounted enclosures. - **High Linearity and Stability:** Ensures minimal drift and high repeatability across temperature and time. - **Ease of Integration:** Standardized input/output connections simplify wiring to sensors and control systems. - **Versatile Application Range:** Suitable for load, pressure, torque, and displacement measurement systems.

Manufacturer: No category

Category: DMS / strain gauge / Brückenverstärker

Request a quote
7.1.4.5 Modul Brücke / DMS, 3,0mV/V, 333-fach MDDMS3812
Modul Brücke / DMS, 3,0mV/V, 333-fach

- **Bridge / DMS Signal Amplifier:** Specifically engineered for strain gauge and Wheatstone bridge sensors. - **Input Sensitivity:** 3.0 mV/V nominal, optimized for typical load cells, pressure transducers, and torque sensors. - **Amplification Factor:** 333‑fold (333×) gain, ensuring precise scaling of low‑level sensor signals to a ±5 V output range. - **Output Signal:** ±5 V analog output, compatible with standard analog input modules, PLCs, and data acquisition systems. - **High Signal Integrity:** Low noise, high linearity amplification for accurate measurement results. - **Compact Modular Design:** Designed for integration into modular measurement systems or DIN‑rail mounting environments. - **Industrial Reliability:** Rugged construction suitable for continuous operation in industrial and laboratory conditions. - **Ease of Integration:** Standardized electrical interfaces simplify connection to existing measurement chains. - **Stable Excitation and Reference:** Provides consistent excitation voltage for bridge sensors, ensuring measurement stability. - **Temperature Compensation:** Designed to maintain accuracy across a wide operating temperature range (typical for DMS modules).

Manufacturer: No category

Category: DMS / strain gauge / Brückenverstärker

Request a quote
7.1.4.5 Modul Brücke / DMS, 2,0mV/V MDDMS3820
Modul Brücke / DMS, 2,0mV/V

- **Bridge Amplifier for DMS Sensors:** Optimized for strain gauge and Wheatstone bridge sensors with a nominal output of 2.0 mV/V. - **High Amplification Factor:** Provides a fixed gain of approximately **250×**, enabling precise signal scaling from millivolt-level sensor outputs to a ±5 V analog output range. - **Standardized Output Signal:** Delivers a **bipolar ±5 V** output compatible with most analog input modules, controllers, and data acquisition systems. - **Low Noise and High Stability:** Designed for high signal integrity, minimizing drift and noise for accurate long-term measurements. - **Compact Modular Design:** Suitable for integration into modular measurement systems, control cabinets, or distributed sensor networks. - **Industrial-Grade Construction:** Built for robust operation in demanding environments, ensuring reliable performance under varying temperature and load conditions. - **Ease of Integration:** Compatible with standard bridge sensors, load cells, pressure transducers, and torque sensors. - **Power Supply Flexibility:** Operates from a standard DC supply (typically 12–24 V DC, depending on system configuration). - **Signal Conditioning:** Includes internal filtering and offset adjustment for optimized measurement accuracy. - **High Linearity and Repeatability:** Ensures consistent output proportional to the applied mechanical or electrical input.

Manufacturer: No category

Category: DMS / strain gauge / Brückenverstärker

Request a quote
7.1.4.5 Modul Brücke / DMS, 2,5mV/V MDDMS3821
Modul Brücke / DMS, 2,5mV/V

- **Bridge Amplifier for DMS Sensors:** Optimized for strain gauge and Wheatstone bridge sensors with a nominal sensitivity of 2.5 mV/V. - **High Amplification Factor:** Provides a **200× amplification**, enabling precise conversion of low-level sensor signals into robust analog outputs suitable for data acquisition systems. - **Standardized Output Signal:** Delivers a **±5 V analog output**, compatible with most industrial controllers, PLCs, and data loggers. - **Low Noise and High Stability:** Designed for high signal integrity, minimizing drift and interference in demanding environments. - **Compact Modular Design:** The module form factor allows easy integration into control cabinets, DIN-rail systems, or modular instrumentation setups. - **Robust Industrial Construction:** Built for long-term reliability under varying temperature and vibration conditions. - **Ease of Integration:** Compatible with a wide range of bridge sensors, including load cells, pressure transducers, torque sensors, and displacement gauges. - **Precision Calibration:** Factory-calibrated for 2.5 mV/V input range, ensuring consistent and repeatable measurement performance. - **Power Supply Compatibility:** Operates from standard industrial DC supply voltages (typically 12–24 V DC, depending on configuration). - **Signal Conditioning:** Incorporates filtering and offset adjustment to optimize measurement accuracy.

Manufacturer: No category

Category: DMS / strain gauge / Brückenverstärker

Request a quote
7.1.4.5 Modul Brücke / DMS, 3,0mV/V MDDMS3822
Modul Brücke / DMS, 3,0mV/V

- **Bridge Amplifier for DMS Sensors:** Specifically designed for strain gauge and bridge-type transducers with a nominal sensitivity of 3.0 mV/V. - **High Amplification Factor:** Provides a fixed gain of approximately 166×, optimized for converting millivolt-level bridge outputs into standardized ±5 V analog signals. - **Precision Output:** Delivers a bipolar ±5 V output suitable for analog input modules, data acquisition systems, or control electronics. - **Stable and Linear Performance:** Ensures minimal drift, low noise, and high linearity across the full measurement range. - **Compact Modular Design:** Built as a modular component for easy integration into multi-channel measurement systems or control cabinets. - **Compatibility:** Supports standard full-bridge, half-bridge, and quarter-bridge configurations (depending on wiring and sensor type). - **Industrial Reliability:** Designed for continuous operation in industrial environments, with robust electrical isolation and stable reference excitation. - **Ease of Integration:** Standardized input/output connections simplify wiring and configuration. - **Signal Conditioning:** Includes excitation supply, amplification, and output scaling in a single compact module.

Manufacturer: No category

Category: DMS / strain gauge / Brückenverstärker

Request a quote