5B32-02
- **Input Range:** 0 to 20 mA current input - **Output Range:** 0 to 5 V voltage output - **High Accuracy:** Designed for precise current-to-voltage conversion with minimal linearity error and low drift. - **Electrical Isolation:** Provides 1500 V rms isolation between input, output, and power, protecting downstream equipment and ensuring measurement integrity. - **Compact Modular Design:** Standard 5B form factor for easy installation into 5B backplanes or DIN-rail carriers. - **Plug-and-Play Compatibility:** Fully compatible with 5B Series backplanes, carriers, and data acquisition systems. - **Low Power Consumption:** Optimized for low power operation, suitable for multi-channel systems. - **High Common-Mode Rejection:** Excellent noise immunity in industrial environments. - **Factory-Calibrated:** Each module is pre-calibrated for its specified input/output range, minimizing setup time. - **Wide Operating Temperature Range:** Designed for reliable operation in industrial temperature conditions. - **Rugged Construction:** Encapsulated design for protection against vibration, humidity, and contaminants.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B34-01
- **RTD Input Compatibility:** Accepts **Pt100** platinum RTDs with 2-, 3-, or 4-wire connections, ensuring accurate temperature measurement and compensation for lead resistance. - **Temperature Range:** Measures temperatures from **–100°C to +100°C**, covering a wide range of low-temperature industrial and laboratory applications. - **Output Signal:** Provides a **0–5 V analog output**, linearly proportional to the input temperature range, enabling direct interfacing with analog input modules, controllers, or data acquisition systems. - **High Accuracy and Stability:** Factory-calibrated for precise linearization of the RTD response curve, ensuring minimal measurement error and long-term stability. - **Galvanic Isolation:** Incorporates **1500 V rms isolation** (typical for 5B modules) between input, output, and power, protecting downstream equipment from ground loops and electrical noise. - **Compact Modular Design:** Fits into standard 5B backplanes, allowing multiple modules to be installed in a single rack for multi-channel temperature monitoring. - **Low Power Consumption:** Optimized for low power operation, suitable for distributed measurement systems. - **Rugged Industrial Construction:** Designed to operate reliably in demanding environments with wide temperature tolerance and vibration resistance. - **Plug-and-Play Integration:** Compatible with 5B Series mounting racks and accessories, simplifying installation and maintenance. - **Signal Conditioning:** Provides linearization, amplification, filtering, and isolation in a single compact module.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B34-02
- **RTD Input Compatibility:** Accepts **Pt100** platinum resistance temperature detectors, supporting **2-wire, 3-wire, and 4-wire** connections for maximum flexibility and accuracy. - **Temperature Range:** Configured for **0°C to +100°C** input range, ideal for low- to medium-temperature industrial processes. - **Standardized Output:** Provides a **0–5 VDC analog output**, directly compatible with most analog input channels of data acquisition systems. - **High Accuracy and Stability:** Factory-calibrated for precise linearization of the RTD signal, minimizing nonlinearity and drift over time. - **Galvanic Isolation:** Offers **1500 V rms isolation** between input, output, and power, ensuring protection against ground loops and electrical interference. - **Compact Modular Design:** Fits into standard 5B backplanes, allowing easy installation, replacement, and system expansion. - **Low Power Consumption:** Designed for efficient operation from a single +5 VDC supply, minimizing system power requirements. - **Noise Immunity:** Incorporates filtering and shielding to reduce susceptibility to electromagnetic interference (EMI) and radio frequency interference (RFI). - **Plug-and-Play Integration:** Pre-calibrated and ready for immediate use with compatible 5B backplanes and data acquisition systems. - **Rugged Industrial Construction:** Built for reliable operation in demanding environments, with robust mechanical and electrical design.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B34-03
- **RTD Input Compatibility:** Accepts **Pt100** platinum RTDs with 2-, 3-, or 4-wire connections, ensuring flexibility in wiring and compensation for lead resistance. - **Temperature Range:** Measures temperatures from **0°C to +200°C**, suitable for a wide range of industrial and laboratory environments. - **Linearized Output:** Provides a **0–5 VDC** analog output signal proportional to the measured temperature, simplifying interface with analog input channels. - **High Accuracy and Stability:** Factory-calibrated for precise temperature-to-voltage conversion with minimal drift over time and temperature. - **Galvanic Isolation:** Typical 1500 VDC isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise. - **Compact Form Factor:** Designed for use in 5B Series backplanes or DIN-rail carriers, allowing high-density installation. - **Plug-and-Play Integration:** Compatible with standard 5B backplanes and data acquisition systems, enabling modular expansion. - **Low Power Consumption:** Optimized for low current draw, suitable for multi-channel systems. - **Rugged Industrial Design:** Encapsulated construction for vibration resistance and long-term reliability.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B34-04
- **RTD Input Compatibility:** Designed for **Pt100 platinum RTDs**, supporting 2-, 3-, and 4-wire connections for flexible installation and compensation of lead resistance. - **Wide Temperature Range:** Measures temperatures from **0°C to +600°C**, suitable for industrial process monitoring, laboratory instrumentation, and environmental control systems. - **Standardized Voltage Output:** Provides a **0 to +5 V** analog output proportional to the input temperature, compatible with most analog input modules, data acquisition systems, and controllers. - **High Accuracy and Stability:** Factory-calibrated for precise linearization of the Pt100 sensor curve, ensuring accurate temperature representation across the full measurement range. - **Electrical Isolation:** Incorporates **1500 V rms isolation** (typical for 5B modules) between input, output, and power, protecting downstream equipment from ground loops and electrical noise. - **Compact Modular Design:** Housed in a compact plug-in module format compatible with 5B Series backplanes and mounting racks. - **Low Power Consumption:** Designed for efficient operation from a single +5 V supply, minimizing system power requirements. - **Rugged Industrial Construction:** Built for reliable operation in demanding environments, with robust encapsulation and high immunity to electromagnetic interference (EMI). - **Ease of Integration:** Standardized pinout and mechanical form factor ensure compatibility with existing 5B Series carriers and accessories.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B37-B05
- **Thermocouple Input Type:** Type B (Platinum-Rhodium / Platinum thermocouple) - **Input Range:** 0°C to +1800°C - **Output Range:** 0 to +5 V DC - **Non-linearized Output:** Provides a direct, uncorrected voltage proportional to the thermocouple’s millivolt signal, scaled to the specified output range. - **High Electrical Isolation:** Galvanic isolation between input, output, and power supply, typically rated at 1500 V rms or higher, ensuring protection against ground loops and electrical noise. - **Compact 5B Form Factor:** Standardized plug-in module compatible with 5B backplanes and carriers. - **High Accuracy and Stability:** Designed for precision temperature measurement and signal conditioning in demanding environments. - **Low Power Consumption:** Optimized for multi-channel data acquisition systems. - **Rugged Industrial Design:** Suitable for use in harsh environments, with robust construction and reliable performance. - **Ease of Integration:** Compatible with a wide range of data acquisition systems, PLCs, and analog input modules.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B37-E04
- **Thermocouple Input Type:** Type E (Chromel-Constantan) - **Input Range:** 0°C to +900°C - **Output Range:** 0 to +5 V DC - **Non-linearized Output:** Provides direct proportional voltage output without internal linearization, allowing external software or hardware linearization if required. - **High Accuracy Signal Conditioning:** Designed for precise thermocouple signal amplification and scaling. - **Electrical Isolation:** Typical of 5B modules, offering 1500 V RMS isolation between input, output, and power to protect data acquisition systems from ground loops and electrical noise. - **Compact Modular Design:** Standard 5B form factor for easy integration into backplanes and mounting racks. - **Cold Junction Compensation (CJC):** Typically integrated in 5B thermocouple modules to ensure accurate temperature measurement by compensating for reference junction temperature variations. - **Plug-and-Play Compatibility:** Designed for use with 5B Series backplanes and carriers, enabling quick installation and replacement. - **Industrial Reliability:** Rugged design suitable for harsh environments, with wide operating temperature range and robust electrical characteristics.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B37-J01
- **Thermocouple Type J Input:** Designed specifically for iron–constantan (Type J) thermocouples, covering a wide temperature range from –100°C to +760°C. - **Non-linearized Output:** Provides a direct, uncorrected voltage output proportional to the thermocouple’s natural response curve, allowing external linearization or software compensation. - **Standardized Output Signal:** Converts the thermocouple input to a **0–5 V DC output**, compatible with most analog input channels, data acquisition systems, and PLCs. - **High Common-Mode Isolation:** Typical 1500 V RMS isolation between input, output, and power, ensuring signal integrity and protection against ground loops. - **Compact 5B Form Factor:** Standardized plug-in module compatible with 5B backplanes and carriers, enabling easy integration and replacement. - **Low Noise and High Accuracy:** Engineered for precision measurement applications, minimizing thermal drift and electrical interference. - **Wide Operating Range:** Suitable for industrial environments with extended temperature and humidity tolerance. - **Ease of Integration:** Designed for use with 5B Series backplanes, providing screw-terminal or plug-in connectivity for thermocouple leads and output wiring. - **Rugged Construction:** Encapsulated module design for mechanical stability and environmental protection.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B37-K02
- **Thermocouple Input Compatibility:** Designed for Type K thermocouples, covering a wide temperature range from –100°C to +1350°C. - **Signal Conditioning:** Converts low-level thermocouple signals into a high-level, noise-resistant 0–5 V output suitable for analog-to-digital converters (ADCs) or data acquisition systems. - **Non-linearized Output:** Provides a direct, uncorrected voltage output proportional to the thermocouple’s natural response curve, allowing external linearization or software compensation. - **High Electrical Isolation:** Incorporates 1500 V rms galvanic isolation between input, output, and power, protecting measurement systems from ground loops and high common-mode voltages. - **Compact Modular Design:** Standard 5B Series form factor for easy installation into backplanes or DIN-rail carriers. - **High Accuracy and Stability:** Precision amplification and filtering ensure low noise and minimal drift over time and temperature. - **Wide Operating Range:** Suitable for harsh industrial environments with extended temperature and humidity tolerance. - **Plug-and-Play Integration:** Compatible with 5B Series backplanes, providing standardized power and signal connections. - **Rugged Construction:** Encapsulated module design for mechanical protection and electrical shielding.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B37-R05
- **Thermocouple Type R Input:** Specifically designed for platinum-rhodium (Pt13%Rh–Pt) thermocouples, covering a wide temperature range from **0°C to +1750°C**. - **Non-linearized Output:** The module provides a direct voltage output proportional to the thermocouple’s millivolt signal, scaled to 0–5 V, without internal linearization. This allows external linearization or software-based correction for high-precision applications. - **Standardized Output Signal:** Produces a **0–5 V DC output**, compatible with most analog input channels of data acquisition systems, PLCs, and control modules. - **High Electrical Isolation:** Typical 1500 V RMS isolation between input, output, and power, protecting downstream electronics from ground loops and high common-mode voltages. - **Compact Plug-in Module:** Designed for use with 5B backplanes or mounting cards, enabling modular installation and easy replacement. - **Low Noise and High Accuracy:** Engineered for stable, low-drift operation with high common-mode rejection ratio (CMRR), ensuring precise temperature measurement even in electrically noisy environments. - **Wide Operating Range:** Suitable for industrial temperature monitoring, furnace control, metallurgical processes, and laboratory instrumentation. - **Rugged Construction:** Encapsulated design for protection against mechanical stress, humidity, and contamination.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B37-S05
- **Thermocouple Type:** Type S (Platinum–Rhodium / Platinum) - **Input Range:** 0°C to +1750°C - **Output Range:** 0 to +5 V DC - **Non-linearized Output:** Provides a direct proportional voltage output without internal linearization, allowing external software or hardware compensation. - **High Accuracy and Stability:** Designed for precision temperature measurement in high-temperature industrial processes. - **Galvanic Isolation:** Typical 1500 V RMS isolation between input, output, and power, ensuring signal integrity and protection against ground loops. - **Compact 5B Series Form Factor:** Standardized plug-in module compatible with 5B backplanes and carriers. - **Cold Junction Compensation (CJC):** Typically integrated within the 5B37 module family to maintain measurement accuracy across ambient temperature variations. - **Low Noise and High Common-Mode Rejection:** Ensures reliable operation in electrically noisy industrial environments. - **Wide Operating Temperature Range:** Suitable for harsh industrial conditions. - **Plug-and-Play Integration:** Compatible with 5B Series backplanes, data acquisition systems, and PLC I/O modules.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B37-T03
- **Thermocouple Type T Input:** Designed specifically for Type T (copper-constantan) thermocouples, ensuring accurate measurement of low-temperature ranges. - **Input Range:** –100°C to +400°C, suitable for laboratory, industrial, and process monitoring applications. - **Output Range:** 0–5 V DC, compatible with most analog input channels on data acquisition systems and controllers. - **Non-linearized Output:** Provides a direct proportional voltage output without internal linearization, allowing external systems or software to perform custom linearization or compensation. - **High Common-Mode Isolation:** Typical 1500 V RMS isolation between input, output, and power, protecting downstream equipment from ground loops and electrical noise. - **Compact 5B Series Form Factor:** Standardized plug-in module design for use with 5B backplanes and carriers. - **Cold Junction Compensation (CJC):** Typically integrated within the 5B37 module family to ensure accurate thermocouple readings by compensating for reference junction temperature variations. - **High Accuracy and Stability:** Precision amplification and filtering circuitry minimize drift and noise, ensuring reliable long-term operation. - **Wide Operating Temperature Range:** Designed for industrial environments, typically –40°C to +85°C operating range. - **Plug-and-Play Compatibility:** Fully compatible with 5B backplanes, mounting racks, and data acquisition systems supporting the 5B interface standard.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B38-02
- **Dedicated for DMS/Strain-Gage Full Bridge Sensors:** Designed to interface directly with full-bridge strain-gage transducers, load cells, and pressure sensors. - **Excitation Supply:** Provides a stable **+10 V excitation voltage** to power the connected bridge circuit, ensuring consistent sensor performance and linearity. - **Input Sensitivity:** Optimized for sensors with **3 mV/V** nominal output sensitivity, allowing accurate measurement of mechanical strain, load, or pressure. - **Bridge Resistance Range:** Compatible with bridge impedances from **300 Ω to 10 kΩ**, covering a wide range of industrial and laboratory-grade transducers. - **High Bandwidth:** Operates with a signal bandwidth up to **10 kHz**, enabling dynamic measurement of rapidly changing mechanical signals. - **Isolated Output:** Provides a **±5 V analog output** that is galvanically isolated from the input and system ground, minimizing ground loops and electrical interference. - **Compact 5B Form Factor:** Conforms to the 5B module standard, allowing plug-in installation into 5B backplanes or carriers. - **High Common-Mode Rejection:** Ensures accurate signal measurement even in electrically noisy environments. - **Rugged and Reliable:** Designed for industrial environments with robust electrical isolation and long-term stability. - **Ease of Integration:** Compatible with standard 5B backplanes, data acquisition systems, and signal conditioning racks.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B38-04
- **Dedicated for DMS / Strain Gauge Half-Bridge Sensors:** Optimized for half-bridge configurations with 3 mV/V sensitivity. - **Integrated Excitation Supply:** Provides a regulated **+10 V excitation voltage** to the connected bridge sensor, ensuring stable and accurate measurement. - **Wide Bridge Resistance Range:** Compatible with bridge resistances between **300 Ω and 10 kΩ**, accommodating a broad range of strain gauge types. - **High Bandwidth:** Operates with a **10 kHz bandwidth**, enabling accurate dynamic measurements and fast response to changing loads or strains. - **Standardized Output Signal:** Delivers a **±5 V analog output**, directly compatible with most analog input modules, DAQ systems, and control interfaces. - **Electrical Isolation:** Typical of 5B modules, providing galvanic isolation between input, output, and power supply to prevent ground loops and improve measurement integrity. - **Compact Modular Design:** Fits standard 5B backplanes and carriers, allowing easy integration into modular signal conditioning systems. - **High Accuracy and Stability:** Designed for precision measurement applications requiring low noise, low drift, and high linearity. - **Plug-and-Play Compatibility:** Fully compatible with the 5B series ecosystem, including backplanes, mounting racks, and data acquisition interfaces.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B38-05
- **Dedicated for Full-Bridge Strain Gauge Sensors:** Optimized for DMS (strain gauge) full-bridge configurations with a nominal sensitivity of **2 mV/V**. - **Integrated Excitation Supply:** Provides a stable **+10 V excitation voltage** to power the strain gauge bridge, ensuring consistent and accurate measurement performance. - **Wide Bridge Resistance Compatibility:** Supports bridge resistances from **300 Ω to 10 kΩ**, accommodating a broad range of strain gauge types and applications. - **High Bandwidth:** Operates with a **10 kHz bandwidth**, enabling accurate dynamic measurements and fast response for transient or vibration monitoring. - **Standardized Output Signal:** Delivers a **±5 V analog output**, compatible with most analog input channels, data acquisition systems, and control interfaces. - **Electrical Isolation:** Provides galvanic isolation between input, output, and power supply, protecting downstream electronics from ground loops and electrical noise. - **Compact Modular Design:** Fits into standard 5B backplanes or carriers, allowing easy installation, replacement, and system expansion. - **High Accuracy and Stability:** Designed for precision measurement applications requiring low noise, high linearity, and long-term stability. - **Industrial-Grade Reliability:** Built for continuous operation in demanding environments, with robust construction and high immunity to interference.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B39-01
- **Voltage-to-Current Conversion:** Converts a 0–5 V analog input signal into a proportional 4–20 mA current output, suitable for standard process control loops. - **High Accuracy and Linearity:** Ensures precise signal representation with minimal nonlinearity and drift over temperature and time. - **Galvanic Isolation:** Provides 1500 V rms isolation between input, output, and power, protecting connected equipment from ground loops and electrical interference. - **Compact Modular Design:** Fits into standard 5B Series backplanes, allowing flexible configuration and easy maintenance. - **Wide Operating Range:** Designed for industrial environments with extended temperature tolerance and robust electrical performance. - **Plug-and-Play Integration:** Compatible with 5B Series mounting racks and backplanes, simplifying installation and system expansion. - **Low Power Consumption:** Optimized for efficient operation in multi-channel systems. - **High Common-Mode Rejection:** Reduces noise and interference in electrically noisy environments. - **Factory-Calibrated:** Each module is pre-calibrated for its specified input/output range, minimizing setup time. - **DIN Rail and Panel Mount Options:** Supports multiple installation configurations for flexible deployment.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B39-02
- **Voltage-to-Current Conversion:** Converts a ±5 V analog input signal into a proportional 4–20 mA output current. - **High Accuracy and Linearity:** Ensures precise signal representation with minimal nonlinearity and drift. - **3000 V RMS Isolation:** Provides galvanic isolation between input and output, protecting downstream equipment and ensuring signal integrity in noisy environments. - **Wide Operating Temperature Range:** Designed for industrial environments, typically operating from –40 °C to +85 °C. - **Compact Plug-In Module:** Fits into standard 5B Series backplanes or mounting racks, simplifying installation and maintenance. - **Low Power Consumption:** Optimized for efficient operation in multi-channel systems. - **Overrange Protection:** Protects input circuitry from accidental overvoltage conditions. - **Factory-Calibrated:** Each module is pre-calibrated for its specified input/output range, minimizing setup time. - **Compatibility:** Fully compatible with other 5B Series modules and backplanes, enabling mixed-signal configurations. - **High Common-Mode Rejection Ratio (CMRR):** Ensures accurate signal conversion even in the presence of common-mode noise.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B39-03
- **Signal Conversion:** Converts a 0–5 V analog input signal into a 0–20 mA current output. - **High Accuracy:** Designed for precise signal conditioning with minimal linearity error and low drift. - **Galvanic Isolation:** Provides 1500 V rms (typical) isolation between input, output, and power, protecting connected equipment from ground loops and electrical noise. - **Compact Modular Design:** Standard 5B form factor for easy integration into backplanes or DIN-rail carriers. - **Wide Operating Range:** Supports industrial temperature ranges and stable operation under varying environmental conditions. - **Plug-and-Play Compatibility:** Fully compatible with 5B backplanes, carriers, and data acquisition systems. - **Low Power Consumption:** Efficient design suitable for multi-channel installations. - **High Common-Mode Rejection:** Ensures accurate signal transmission even in electrically noisy environments. - **Factory-Calibrated:** Pre-calibrated for specified input/output ranges, minimizing setup time. - **Rugged Construction:** Encapsulated module for protection against vibration, humidity, and dust.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B39-04
- **Voltage-to-Current Conversion:** Converts a ±5 V analog input signal into a proportional 0–20 mA current output. - **High Accuracy and Linearity:** Designed for precise signal conditioning with minimal nonlinearity and drift. - **Electrical Isolation:** Provides 1500 V rms isolation between input, output, and power, protecting downstream equipment and ensuring signal integrity. - **Compact Modular Design:** Standard 5B Series form factor for easy installation in backplanes or DIN-rail-mounted carriers. - **Wide Compatibility:** Interfaces seamlessly with data acquisition systems, PLCs, and distributed control systems (DCS). - **Low Noise and High Stability:** Incorporates advanced filtering and shielding to minimize noise pickup and maintain stable operation in electrically noisy environments. - **Factory-Calibrated:** Each module is factory-calibrated for its specified input and output ranges, reducing setup time and ensuring consistent performance. - **Plug-and-Play Integration:** Designed for use with 5B Series backplanes, allowing quick module replacement and system expansion. - **Rugged Industrial Construction:** Built to operate reliably in demanding industrial environments with wide temperature tolerance and robust mechanical design.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B40
- **Wide Bandwidth Design:** Optimized for high-frequency signal conditioning, enabling accurate transmission of dynamic or rapidly changing analog signals. - **Input Range:** ±10 mV differential input range, ideal for low-level sensor or transducer signals. - **Output Range:** ±5 V analog output, compatible with standard data acquisition (DAQ) systems and analog input modules. - **High Accuracy and Linearity:** Provides precise signal amplification with minimal distortion or drift. - **Galvanic Isolation:** Input-to-output and power isolation to eliminate ground loops and protect downstream equipment. - **Compact Modular Form Factor:** Standard 5B Series plug-in module design for easy installation and replacement. - **Low Noise Performance:** Engineered for low input noise and high signal-to-noise ratio (SNR). - **Rugged Industrial Design:** Operates reliably in harsh environments with wide temperature tolerance and robust mechanical construction. - **Compatibility:** Fully compatible with 5B Series backplanes, carriers, and mounting systems. - **Ease of Integration:** Standardized pinout and mechanical interface for seamless integration into existing 5B-based systems.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B41
- **Wide Bandwidth Performance:** Designed for high-frequency analog signals, the 5B41 offers wide-band operation suitable for dynamic signal measurement and conditioning. - **Input/Output Range:** Accepts a **±1 V input** and provides a **±5 V output**, enabling signal amplification by a factor of 5. - **High Linearity and Accuracy:** Ensures precise signal reproduction with minimal distortion and low nonlinearity across the full input range. - **Electrical Isolation:** Provides **1500 V rms isolation** between input, output, and power, protecting downstream equipment and reducing ground loop interference. - **Compact Plug-In Module:** Fits into standard 5B Series backplanes and carriers, allowing modular configuration and easy replacement. - **High Common-Mode Rejection:** Excellent CMRR performance ensures accurate measurement even in noisy industrial environments. - **Low Noise Design:** Optimized internal circuitry minimizes noise contribution, preserving signal integrity. - **Wide Operating Temperature Range:** Suitable for harsh environments, typically operating from **–40°C to +85°C**. - **Compatibility:** Fully compatible with 5B Series backplanes, mounting racks, and data acquisition systems. - **Factory Calibrated:** Each module is factory calibrated for its specified input/output range, ensuring out-of-the-box accuracy.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B47-E08
- **Thermocouple Type:** Type E (Chromel-Constantan) - **Input Range:** 0°C to +1000°C - **Output Range:** 0 to +5 V DC (linearized) - **Linearization:** Internal cold-junction compensation and linearization for Type E thermocouples - **High Accuracy:** Factory-calibrated for precise temperature-to-voltage conversion - **Electrical Isolation:** 1500 V RMS isolation between input, output, and power - **Low Noise:** Designed for low drift and high signal integrity in noisy industrial environments - **Compact Form Factor:** Standard 5B module size for plug-in installation - **Plug-and-Play Compatibility:** Fits standard 5B backplanes and carriers - **Wide Operating Temperature Range:** Suitable for industrial temperature conditions - **Rugged Construction:** Encapsulated design for protection against vibration, humidity, and contaminants - **Ease of Integration:** Standardized pinout and output scaling for direct connection to analog input channels of data acquisition systems
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B47-J01
- **Thermocouple Type:** Type J (Iron–Constantan) - **Input Range:** 0°C to +760°C - **Output Range:** 0 to +5 V DC - **Linearization:** Internal cold-junction compensation and linearization for Type J thermocouple characteristics - **High Accuracy:** Factory-calibrated for precise temperature-to-voltage conversion - **Galvanic Isolation:** Provides 1500 V RMS isolation between input, output, and power to eliminate ground loops and enhance measurement integrity - **Signal Conditioning:** Includes amplification, filtering, and linearization in a single compact module - **Plug-in Module Design:** Compatible with 5B Series backplanes and mounting racks for easy installation and replacement - **Low Noise and Drift:** Designed for stable operation in industrial environments with minimal thermal drift and noise interference - **Wide Operating Temperature Range:** Suitable for use in demanding environments - **Compact Form Factor:** Optimized for high-density signal conditioning applications
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B47-J02
- **Thermocouple Type J Input:** Designed specifically for iron–constantan (Type J) thermocouples, ensuring accurate temperature measurement across a defined range. - **Input Range:** –100°C to +300°C, covering a broad span suitable for industrial and laboratory temperature monitoring. - **Output Range:** 0 to 5 V DC, providing a standardized analog signal compatible with most data acquisition and control systems. - **Linearized Output:** Internal circuitry compensates for the nonlinear characteristics of thermocouple response, delivering a linear voltage output proportional to temperature. - **High Accuracy and Stability:** Precision amplification and cold-junction compensation ensure reliable and repeatable measurements. - **Galvanic Isolation:** Input, output, and power are isolated to prevent ground loops and protect connected equipment from electrical interference. - **Compact Modular Design:** Standard 5B form factor allows easy installation into backplanes or mounting racks. - **Plug-and-Play Compatibility:** Designed for use with 5B series backplanes and carriers, simplifying integration into existing systems. - **Cold Junction Compensation (CJC):** Built-in compensation for ambient temperature variations at the thermocouple connection point. - **Rugged Industrial Construction:** Designed for harsh environments with robust electrical isolation and noise immunity.
Manufacturer: No category
Category: Signalkonditionierung 5B Module
5B47-J03
- **Thermocouple Input Type:** Type J (Iron–Constantan) - **Input Temperature Range:** 0°C to +500°C - **Output Signal:** 0 to +5 V DC, linearized with respect to temperature - **Linearization:** Internal cold-junction compensation and linearization circuitry ensure accurate temperature-to-voltage conversion. - **Isolation:** High galvanic isolation between input, output, and power (typically 1500 V rms or higher), protecting downstream electronics from ground loops and electrical noise. - **Accuracy:** Factory-calibrated for precise temperature measurement and output scaling. - **Low Drift:** Stable operation over time and temperature variations due to precision components and internal compensation. - **Compact Form Factor:** Standard 5B module size for easy integration into existing 5B backplanes. - **Plug-and-Play Compatibility:** Designed for use with 5B series backplanes, carriers, and mounting racks. - **Rugged Industrial Design:** Suitable for harsh environments, with robust input protection and reliable performance. - **Ease of Integration:** Directly interfaces with analog input channels of DAQ systems, controllers, and monitoring equipment. - **Cold Junction Compensation (CJC):** Built-in CJC sensor ensures accurate thermocouple measurement without external compensation. - **Signal Conditioning:** Provides amplification, filtering, and isolation in a single module.
Manufacturer: No category
Category: Signalkonditionierung 5B Module