LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
- 8 Isolated Analog Input Channels: Each input channel is galvanically isolated, providing enhanced noise immunity and protection against ground loops and voltage surges.
- 12-bit Resolution: Delivers precise analog-to-digital conversion suitable for measurement and monitoring applications requiring moderate accuracy.
- Sampling Rate: Supports up to 800 samples per second (800 S/s), enabling real-time data acquisition for slow to medium-speed analog signals.
- Multiple Input Ranges: Configurable gain settings for various signal types, including:
- 0–5 V
- 1–5 V
- 0–20 mA
- 4–20 mA
This flexibility allows direct connection to a wide range of sensors and transducers.
- High Isolation Voltage:
- Channel-to-channel isolation: 750 V RMS
- Input/output isolation: 750 V RMS
- TTL opto-isolation: up to 5 kV
These isolation ratings ensure safe operation in electrically noisy or high-voltage environments.
- Digital I/O Support: Provides 2 or 4 TTL-level digital I/O lines, optically isolated for reliable signal interfacing.
- Interrupt Request (IRQ) Configurability: Supports multiple IRQ lines (3–7, 9–12, 14, 15) for flexible system integration and interrupt-driven data acquisition.
- Compact Form Factor: Designed for AT-bus (ISA) PC slots, with a physical size of 160 mm × 122 mm, suitable for standard industrial PCs.
- Connector Type: Equipped with a 37-pin female D-type connector for secure and standardized signal interfacing.
- 12-bit Resolution: Delivers precise analog-to-digital conversion suitable for measurement and monitoring applications requiring moderate accuracy.
- Sampling Rate: Supports up to 800 samples per second (800 S/s), enabling real-time data acquisition for slow to medium-speed analog signals.
- Multiple Input Ranges: Configurable gain settings for various signal types, including:
- 0–5 V
- 1–5 V
- 0–20 mA
- 4–20 mA
This flexibility allows direct connection to a wide range of sensors and transducers.
- High Isolation Voltage:
- Channel-to-channel isolation: 750 V RMS
- Input/output isolation: 750 V RMS
- TTL opto-isolation: up to 5 kV
These isolation ratings ensure safe operation in electrically noisy or high-voltage environments.
- Digital I/O Support: Provides 2 or 4 TTL-level digital I/O lines, optically isolated for reliable signal interfacing.
- Interrupt Request (IRQ) Configurability: Supports multiple IRQ lines (3–7, 9–12, 14, 15) for flexible system integration and interrupt-driven data acquisition.
- Compact Form Factor: Designed for AT-bus (ISA) PC slots, with a physical size of 160 mm × 122 mm, suitable for standard industrial PCs.
- Connector Type: Equipped with a 37-pin female D-type connector for secure and standardized signal interfacing.
Comprehensive Product Summary: ADI12-8CL(PC) – AT AD Card 8DI Isolated 12-bit 800S/s
### 1. Product Overview
Product Name: AT AD Card 8DI Isolated 12-bit 800S/s
Model Number: ADI12-8CL(PC)
Article Number: ADI12-8CL(PC)
Series: ADI12 Series – Isolated Analog-to-Digital (A/D) Conversion Interface Cards
Manufacturer: Contec Co., Ltd.
The ADI12-8CL(PC) is a high-performance analog-to-digital (A/D) conversion interface card designed for PC-based data acquisition and control systems. Developed by Contec, a leading manufacturer of industrial computing and measurement solutions, this model integrates eight isolated analog input channels with 12-bit resolution and a sampling rate of up to 800 samples per second (S/s). The card is engineered for robust industrial environments, offering electrical isolation between channels and between input/output lines to ensure signal integrity and system protection.
### 2. Key Features
- 8 Isolated Analog Input Channels: Each input channel is galvanically isolated, providing enhanced noise immunity and protection against ground loops and voltage surges.
- 12-bit Resolution: Delivers precise analog-to-digital conversion suitable for measurement and monitoring applications requiring moderate accuracy.
- Sampling Rate: Supports up to 800 samples per second (800 S/s), enabling real-time data acquisition for slow to medium-speed analog signals.
- Multiple Input Ranges: Configurable gain settings for various signal types, including:
- 0–5 V
- 1–5 V
- 0–20 mA
- 4–20 mA
This flexibility allows direct connection to a wide range of sensors and transducers.
- High Isolation Voltage:
- Channel-to-channel isolation: 750 V RMS
- Input/output isolation: 750 V RMS
- TTL opto-isolation: up to 5 kV
These isolation ratings ensure safe operation in electrically noisy or high-voltage environments.
- Digital I/O Support: Provides 2 or 4 TTL-level digital I/O lines, optically isolated for reliable signal interfacing.
- Interrupt Request (IRQ) Configurability: Supports multiple IRQ lines (3–7, 9–12, 14, 15) for flexible system integration and interrupt-driven data acquisition.
- Compact Form Factor: Designed for AT-bus (ISA) PC slots, with a physical size of 160 mm × 122 mm, suitable for standard industrial PCs.
- Connector Type: Equipped with a 37-pin female D-type connector for secure and standardized signal interfacing.
### 3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| Model | ADI12-8CL(PC) |
| Manufacturer | Contec Co., Ltd. |
| Analog Input Channels | 8 isolated channels |
| Resolution | 12 bits |
| Sampling Rate | 800 samples per second (800 S/s) |
| Input Ranges | 0–5 V, 1–5 V, 0–20 mA, 4–20 mA |
| Gain Settings | Selectable per channel |
| Isolation Voltage (Channel-to-Channel) | 750 V RMS |
| Isolation Voltage (Input/Output) | 750 V RMS |
| TTL Opto-Isolation | Up to 5 kV |
| Digital I/O | 2 or 4 TTL-level lines (optically isolated) |
| Interrupt Lines (IRQ) | Selectable: 3–7, 9–12, 14, 15 |
| Connector Type | 37-pin female D-type |
| Board Dimensions | 160 mm (L) × 122 mm (W) |
| Bus Interface | AT (ISA) bus |
| Operating Voltage | Derived from PC bus (standard AT slot power) |
| Isolation Type | Channel-to-channel and channel-to-system isolation |
| Input Impedance | High impedance (typical for voltage input) |
| Input Type | Single-ended or isolated differential (depending on configuration) |
| Environmental Conditions | Industrial-grade, designed for stable operation in typical PC enclosures |
| Weight | Approx. 200–300 g (typical for AT card of this size) |
### 4. Functionality
The ADI12-8CL(PC) functions as an analog-to-digital conversion interface between analog sensors and a host PC. Each of the eight input channels can independently acquire analog signals, convert them into 12-bit digital data, and transfer the results to the PC via the AT (ISA) bus.
Operation Principle:
1. Signal Input: Analog signals (voltage or current) are fed into the card through the 37-pin D-type connector.
2. Isolation: Each channel is electrically isolated to prevent interference and protect the PC from high-voltage transients.
3. A/D Conversion: The onboard 12-bit ADC converts the analog input into digital form at up to 800 samples per second.
4. Data Transfer: Converted data is transferred to the PC memory via the AT bus interface, where it can be processed, displayed, or logged by user software.
5. Digital I/O Control: The TTL I/O lines can be used for triggering, control signals, or synchronization with external devices.
Use Cases and Applications:
- Industrial process monitoring and control
- Sensor data acquisition (temperature, pressure, flow, etc.)
- Laboratory instrumentation and test systems
- Environmental monitoring systems
- Embedded control systems requiring isolated analog inputs
- Educational and research applications in electronics and automation
Compatibility:
- Compatible with standard AT (ISA) bus PCs and industrial computers.
- Works with Contec’s driver libraries and data acquisition software.
- Can interface with third-party DAQ software supporting ISA-based A/D cards.
### 5. Components & Accessories
Included Components:
- ADI12-8CL(PC) main card
- 37-pin female D-type connector (onboard)
- User manual and installation guide
- Driver disk or software package (depending on distribution)
Optional Accessories:
- Shielded signal cables (37-pin D-sub to terminal block)
- External terminal boards for easy wiring (e.g., Contec terminal block units)
- Mounting brackets or extension cables for industrial enclosures
- Software development kits (SDKs) for Windows or DOS environments
Connectors:
- Primary Connector: 37-pin female D-type (D-sub)
- Analog input channels (CH0–CH7)
- Digital I/O lines (TTL)
- Ground and reference connections
- Power and control signals
### 6. Installation & Setup
System Requirements:
- PC with available AT (ISA) expansion slot
- Compatible operating system (typically DOS, Windows 95/98/NT, or industrial OS supporting ISA drivers)
- Sufficient power supply from the PC bus
Installation Steps:
1. Power off the PC and remove the cover.
2. Insert the ADI12-8CL(PC) card into an available ISA slot.
3. Secure the card with the mounting screw.
4. Connect analog input and digital I/O lines to the 37-pin connector using appropriate cables.
5. Configure IRQ settings via jumpers or DIP switches on the board (select from IRQ 3–7, 9–12, 14, or 15).
6. Install the driver software and verify device recognition.
7. Calibrate input ranges and verify signal acquisition using test software.
Mounting Options:
- Standard horizontal mounting in PC chassis
- Optional external mounting via extension cable and shielded enclosure
Configuration:
- Input range and gain selection via onboard jumpers or software configuration (depending on revision)
- IRQ and I/O address configuration via hardware switches
- Optional calibration adjustments for voltage/current input scaling
### 7. Performance & Capabilities
Analog Performance:
- Resolution: 12 bits (4096 discrete levels)
- Sampling Rate: 800 S/s per channel (aggregate or sequential, depending on configuration)
- Accuracy: Typical ±0.1% of full scale (application dependent)
- Linearity: High linearity across input range for stable measurement results
Isolation & Protection:
- Channel-to-channel isolation: 750 V RMS ensures minimal crosstalk and high noise immunity.
- Input/output isolation: 750 V RMS protects the host system from external surges.
- Opto-isolation (TTL): Up to 5 kV for digital I/O lines, ensuring safe interfacing with external logic circuits.
Digital I/O Performance:
- TTL-level signals: Compatible with standard 5 V logic.
- Optically isolated: Prevents ground potential differences and electrical interference.
- Configurable lines: 2 or 4 lines can be used for input or output control.
Efficiency & Reliability:
- Low power consumption due to efficient analog circuitry.
- Stable operation under continuous sampling conditions.
- Designed for long-term reliability in industrial environments.
Limitations:
- Moderate sampling rate (800 S/s) limits use to low- and medium-speed analog signals.
- ISA bus interface restricts compatibility with modern PCs (requires legacy or industrial systems).
- 12-bit resolution may not be sufficient for high-precision measurement applications.
### 8. Standards & Compliance
Certifications and Compliance:
- Designed and manufactured in accordance with Contec’s industrial quality standards.
- Complies with ISA (AT bus) electrical and mechanical specifications.
- Meets industrial safety and isolation standards for 750 V RMS isolation.
- Opto-isolation rating (5 kV) conforms to standard insulation test requirements for industrial I/O.
- RoHS compliance (depending on production year) for environmental safety.
- CE marking (for applicable models) indicating conformity with European EMC and safety directives.
Industry Standards Supported:
- ISA/AT bus interface standard
- TTL logic level compatibility
- Analog input ranges compatible with standard industrial sensors (0–5 V, 1–5 V, 0–20 mA, 4–20 mA)
### 9. Additional Information
Warranty:
- Typically covered by Contec’s standard warranty (1–3 years depending on region and distributor).
- Warranty covers manufacturing defects and hardware failures under normal operating conditions.
Technical Support:
- Comprehensive technical documentation and driver support available from Contec’s website.
- Application notes, sample programs, and SDKs provided for integration with custom software.
- Customer support available via email, phone, and online service portals.
Maintenance:
- Minimal maintenance required; periodic inspection of connectors and cables recommended.
- Ensure proper grounding and shielding to maintain isolation performance.
- Firmware or driver updates may be available to enhance compatibility or performance.
Software & Updates:
- Compatible with Contec’s data acquisition software suite.
- Driver updates and SDKs available for legacy and industrial operating systems.
- Example code and libraries provided for C/C++ and other programming environments.
Product Lifecycle:
- Designed for long-term availability in industrial markets.
- Replacement and successor models available within the ADI12 series for extended lifecycle support.
### Summary
The Contec ADI12-8CL(PC) is a robust, isolated 8-channel analog-to-digital conversion card engineered for industrial and laboratory data acquisition applications. With 12-bit resolution, 800 S/s sampling rate, and multiple input ranges (voltage and current), it provides a flexible and reliable interface for analog signal measurement. Its high isolation ratings (750 V RMS channel-to-channel and up to 5 kV opto-isolation for TTL I/O) ensure safe operation in demanding environments.
Designed for the AT (ISA) bus architecture, the ADI12-8CL(PC) integrates seamlessly into legacy and industrial PC systems, offering configurable IRQ lines, optically isolated digital I/O, and a compact 160 × 122 mm form factor. Supported by Contec’s software tools and technical documentation, it remains a dependable solution for engineers and system integrators requiring stable, isolated analog input performance in PC-based control and monitoring systems.
### 1. Product Overview
Product Name: AT AD Card 8DI Isolated 12-bit 800S/s
Model Number: ADI12-8CL(PC)
Article Number: ADI12-8CL(PC)
Series: ADI12 Series – Isolated Analog-to-Digital (A/D) Conversion Interface Cards
Manufacturer: Contec Co., Ltd.
The ADI12-8CL(PC) is a high-performance analog-to-digital (A/D) conversion interface card designed for PC-based data acquisition and control systems. Developed by Contec, a leading manufacturer of industrial computing and measurement solutions, this model integrates eight isolated analog input channels with 12-bit resolution and a sampling rate of up to 800 samples per second (S/s). The card is engineered for robust industrial environments, offering electrical isolation between channels and between input/output lines to ensure signal integrity and system protection.
### 2. Key Features
- 8 Isolated Analog Input Channels: Each input channel is galvanically isolated, providing enhanced noise immunity and protection against ground loops and voltage surges.
- 12-bit Resolution: Delivers precise analog-to-digital conversion suitable for measurement and monitoring applications requiring moderate accuracy.
- Sampling Rate: Supports up to 800 samples per second (800 S/s), enabling real-time data acquisition for slow to medium-speed analog signals.
- Multiple Input Ranges: Configurable gain settings for various signal types, including:
- 0–5 V
- 1–5 V
- 0–20 mA
- 4–20 mA
This flexibility allows direct connection to a wide range of sensors and transducers.
- High Isolation Voltage:
- Channel-to-channel isolation: 750 V RMS
- Input/output isolation: 750 V RMS
- TTL opto-isolation: up to 5 kV
These isolation ratings ensure safe operation in electrically noisy or high-voltage environments.
- Digital I/O Support: Provides 2 or 4 TTL-level digital I/O lines, optically isolated for reliable signal interfacing.
- Interrupt Request (IRQ) Configurability: Supports multiple IRQ lines (3–7, 9–12, 14, 15) for flexible system integration and interrupt-driven data acquisition.
- Compact Form Factor: Designed for AT-bus (ISA) PC slots, with a physical size of 160 mm × 122 mm, suitable for standard industrial PCs.
- Connector Type: Equipped with a 37-pin female D-type connector for secure and standardized signal interfacing.
### 3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| Model | ADI12-8CL(PC) |
| Manufacturer | Contec Co., Ltd. |
| Analog Input Channels | 8 isolated channels |
| Resolution | 12 bits |
| Sampling Rate | 800 samples per second (800 S/s) |
| Input Ranges | 0–5 V, 1–5 V, 0–20 mA, 4–20 mA |
| Gain Settings | Selectable per channel |
| Isolation Voltage (Channel-to-Channel) | 750 V RMS |
| Isolation Voltage (Input/Output) | 750 V RMS |
| TTL Opto-Isolation | Up to 5 kV |
| Digital I/O | 2 or 4 TTL-level lines (optically isolated) |
| Interrupt Lines (IRQ) | Selectable: 3–7, 9–12, 14, 15 |
| Connector Type | 37-pin female D-type |
| Board Dimensions | 160 mm (L) × 122 mm (W) |
| Bus Interface | AT (ISA) bus |
| Operating Voltage | Derived from PC bus (standard AT slot power) |
| Isolation Type | Channel-to-channel and channel-to-system isolation |
| Input Impedance | High impedance (typical for voltage input) |
| Input Type | Single-ended or isolated differential (depending on configuration) |
| Environmental Conditions | Industrial-grade, designed for stable operation in typical PC enclosures |
| Weight | Approx. 200–300 g (typical for AT card of this size) |
### 4. Functionality
The ADI12-8CL(PC) functions as an analog-to-digital conversion interface between analog sensors and a host PC. Each of the eight input channels can independently acquire analog signals, convert them into 12-bit digital data, and transfer the results to the PC via the AT (ISA) bus.
Operation Principle:
1. Signal Input: Analog signals (voltage or current) are fed into the card through the 37-pin D-type connector.
2. Isolation: Each channel is electrically isolated to prevent interference and protect the PC from high-voltage transients.
3. A/D Conversion: The onboard 12-bit ADC converts the analog input into digital form at up to 800 samples per second.
4. Data Transfer: Converted data is transferred to the PC memory via the AT bus interface, where it can be processed, displayed, or logged by user software.
5. Digital I/O Control: The TTL I/O lines can be used for triggering, control signals, or synchronization with external devices.
Use Cases and Applications:
- Industrial process monitoring and control
- Sensor data acquisition (temperature, pressure, flow, etc.)
- Laboratory instrumentation and test systems
- Environmental monitoring systems
- Embedded control systems requiring isolated analog inputs
- Educational and research applications in electronics and automation
Compatibility:
- Compatible with standard AT (ISA) bus PCs and industrial computers.
- Works with Contec’s driver libraries and data acquisition software.
- Can interface with third-party DAQ software supporting ISA-based A/D cards.
### 5. Components & Accessories
Included Components:
- ADI12-8CL(PC) main card
- 37-pin female D-type connector (onboard)
- User manual and installation guide
- Driver disk or software package (depending on distribution)
Optional Accessories:
- Shielded signal cables (37-pin D-sub to terminal block)
- External terminal boards for easy wiring (e.g., Contec terminal block units)
- Mounting brackets or extension cables for industrial enclosures
- Software development kits (SDKs) for Windows or DOS environments
Connectors:
- Primary Connector: 37-pin female D-type (D-sub)
- Analog input channels (CH0–CH7)
- Digital I/O lines (TTL)
- Ground and reference connections
- Power and control signals
### 6. Installation & Setup
System Requirements:
- PC with available AT (ISA) expansion slot
- Compatible operating system (typically DOS, Windows 95/98/NT, or industrial OS supporting ISA drivers)
- Sufficient power supply from the PC bus
Installation Steps:
1. Power off the PC and remove the cover.
2. Insert the ADI12-8CL(PC) card into an available ISA slot.
3. Secure the card with the mounting screw.
4. Connect analog input and digital I/O lines to the 37-pin connector using appropriate cables.
5. Configure IRQ settings via jumpers or DIP switches on the board (select from IRQ 3–7, 9–12, 14, or 15).
6. Install the driver software and verify device recognition.
7. Calibrate input ranges and verify signal acquisition using test software.
Mounting Options:
- Standard horizontal mounting in PC chassis
- Optional external mounting via extension cable and shielded enclosure
Configuration:
- Input range and gain selection via onboard jumpers or software configuration (depending on revision)
- IRQ and I/O address configuration via hardware switches
- Optional calibration adjustments for voltage/current input scaling
### 7. Performance & Capabilities
Analog Performance:
- Resolution: 12 bits (4096 discrete levels)
- Sampling Rate: 800 S/s per channel (aggregate or sequential, depending on configuration)
- Accuracy: Typical ±0.1% of full scale (application dependent)
- Linearity: High linearity across input range for stable measurement results
Isolation & Protection:
- Channel-to-channel isolation: 750 V RMS ensures minimal crosstalk and high noise immunity.
- Input/output isolation: 750 V RMS protects the host system from external surges.
- Opto-isolation (TTL): Up to 5 kV for digital I/O lines, ensuring safe interfacing with external logic circuits.
Digital I/O Performance:
- TTL-level signals: Compatible with standard 5 V logic.
- Optically isolated: Prevents ground potential differences and electrical interference.
- Configurable lines: 2 or 4 lines can be used for input or output control.
Efficiency & Reliability:
- Low power consumption due to efficient analog circuitry.
- Stable operation under continuous sampling conditions.
- Designed for long-term reliability in industrial environments.
Limitations:
- Moderate sampling rate (800 S/s) limits use to low- and medium-speed analog signals.
- ISA bus interface restricts compatibility with modern PCs (requires legacy or industrial systems).
- 12-bit resolution may not be sufficient for high-precision measurement applications.
### 8. Standards & Compliance
Certifications and Compliance:
- Designed and manufactured in accordance with Contec’s industrial quality standards.
- Complies with ISA (AT bus) electrical and mechanical specifications.
- Meets industrial safety and isolation standards for 750 V RMS isolation.
- Opto-isolation rating (5 kV) conforms to standard insulation test requirements for industrial I/O.
- RoHS compliance (depending on production year) for environmental safety.
- CE marking (for applicable models) indicating conformity with European EMC and safety directives.
Industry Standards Supported:
- ISA/AT bus interface standard
- TTL logic level compatibility
- Analog input ranges compatible with standard industrial sensors (0–5 V, 1–5 V, 0–20 mA, 4–20 mA)
### 9. Additional Information
Warranty:
- Typically covered by Contec’s standard warranty (1–3 years depending on region and distributor).
- Warranty covers manufacturing defects and hardware failures under normal operating conditions.
Technical Support:
- Comprehensive technical documentation and driver support available from Contec’s website.
- Application notes, sample programs, and SDKs provided for integration with custom software.
- Customer support available via email, phone, and online service portals.
Maintenance:
- Minimal maintenance required; periodic inspection of connectors and cables recommended.
- Ensure proper grounding and shielding to maintain isolation performance.
- Firmware or driver updates may be available to enhance compatibility or performance.
Software & Updates:
- Compatible with Contec’s data acquisition software suite.
- Driver updates and SDKs available for legacy and industrial operating systems.
- Example code and libraries provided for C/C++ and other programming environments.
Product Lifecycle:
- Designed for long-term availability in industrial markets.
- Replacement and successor models available within the ADI12 series for extended lifecycle support.
### Summary
The Contec ADI12-8CL(PC) is a robust, isolated 8-channel analog-to-digital conversion card engineered for industrial and laboratory data acquisition applications. With 12-bit resolution, 800 S/s sampling rate, and multiple input ranges (voltage and current), it provides a flexible and reliable interface for analog signal measurement. Its high isolation ratings (750 V RMS channel-to-channel and up to 5 kV opto-isolation for TTL I/O) ensure safe operation in demanding environments.
Designed for the AT (ISA) bus architecture, the ADI12-8CL(PC) integrates seamlessly into legacy and industrial PC systems, offering configurable IRQ lines, optically isolated digital I/O, and a compact 160 × 122 mm form factor. Supported by Contec’s software tools and technical documentation, it remains a dependable solution for engineers and system integrators requiring stable, isolated analog input performance in PC-based control and monitoring systems.
-
F_ISA BUS SERIES.pdf
PDF Catalog
No accessories available.