CN20030
LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
- High-Speed Serial Communication: Supports data transfer rates up to 460.8 Kbps per port.
- 8-Port RS-232 Interface: Provides eight independent RS-232 serial ports via RJ45 connectors.
- Modular Expandability: Designed as an Extensive Module for rackmount configurations; can be cascaded with Basic Modules to expand port count.
- Dual RISC Processor Architecture: Utilizes TMS320C52 processors for intelligent offloading of communication tasks from the host CPU.
- On-Chip Hardware Flow Control: Integrated 16550C UARTs with 32-byte FIFO buffers ensure reliable, loss-free data transmission.
- Diagnostic LED Indicators: Front-panel LEDs display per-port line status (TxD, RxD, DTR, DSR, RTS, CTS, DCD).
- Rackmount Design: Fits standard 19-inch industrial racks, suitable for data centers and control rooms.
- Long-Distance Connectivity: Supports cable lengths up to 100 meters (328 ft) between the control board and external modules using long-range extension kits.
- Surge and Isolation Protection: Optional transient voltage surge suppression (TVSS) and high-potential isolation for harsh environments.
- Cross-Platform Driver Support: Compatible with Windows NT/95/98/3.x, DOS, UNIX (SCO, SVR4.2, XENIX, Solaris), Linux, OS/2, and QNX.
- Comprehensive Software Tools: Bundled with PComm (Windows) and API-232 (DOS/Windows 3.x) libraries for application development.
- Easy Installation and Configuration: Plug-and-play hardware setup with intuitive driver utilities and configuration panels.
- 8-Port RS-232 Interface: Provides eight independent RS-232 serial ports via RJ45 connectors.
- Modular Expandability: Designed as an Extensive Module for rackmount configurations; can be cascaded with Basic Modules to expand port count.
- Dual RISC Processor Architecture: Utilizes TMS320C52 processors for intelligent offloading of communication tasks from the host CPU.
- On-Chip Hardware Flow Control: Integrated 16550C UARTs with 32-byte FIFO buffers ensure reliable, loss-free data transmission.
- Diagnostic LED Indicators: Front-panel LEDs display per-port line status (TxD, RxD, DTR, DSR, RTS, CTS, DCD).
- Rackmount Design: Fits standard 19-inch industrial racks, suitable for data centers and control rooms.
- Long-Distance Connectivity: Supports cable lengths up to 100 meters (328 ft) between the control board and external modules using long-range extension kits.
- Surge and Isolation Protection: Optional transient voltage surge suppression (TVSS) and high-potential isolation for harsh environments.
- Cross-Platform Driver Support: Compatible with Windows NT/95/98/3.x, DOS, UNIX (SCO, SVR4.2, XENIX, Solaris), Linux, OS/2, and QNX.
- Comprehensive Software Tools: Bundled with PComm (Windows) and API-232 (DOS/Windows 3.x) libraries for application development.
- Easy Installation and Configuration: Plug-and-play hardware setup with intuitive driver utilities and configuration panels.
Comprehensive Product Summary – Moxa Intellio C32082T 8-Port RS-232 Extensive Module
### 1. Product Overview
Product Name: Intellio C32082T
Model: C32082T
Series: Intellio C320 Turbo Series
Article Number: C32082T
Manufacturer: Moxa Technologies Co., Ltd.
Manufacturer Contact:
- Tel: +886-2-8665-6373
- Fax: +886-2-8665-6372
- Website: [www.moxa.com](http://www.moxa.com)
- Support: support@moxa.com.tw
The Moxa Intellio C32082T is an 8-port RS-232 extensive module designed for use with the Intellio C320 Turbo intelligent multiport communication controller system. It provides high-speed serial connectivity through RJ45 connectors and supports data rates up to 460.8 Kbps. The module is part of a modular, expandable system that can scale from 8 to 128 serial ports per PC, offering robust industrial-grade serial communication for automation, telecommunications, and multi-user applications.
### 2. Key Features
- High-Speed Serial Communication: Supports data transfer rates up to 460.8 Kbps per port.
- 8-Port RS-232 Interface: Provides eight independent RS-232 serial ports via RJ45 connectors.
- Modular Expandability: Designed as an Extensive Module for rackmount configurations; can be cascaded with Basic Modules to expand port count.
- Dual RISC Processor Architecture: Utilizes TMS320C52 processors for intelligent offloading of communication tasks from the host CPU.
- On-Chip Hardware Flow Control: Integrated 16550C UARTs with 32-byte FIFO buffers ensure reliable, loss-free data transmission.
- Diagnostic LED Indicators: Front-panel LEDs display per-port line status (TxD, RxD, DTR, DSR, RTS, CTS, DCD).
- Rackmount Design: Fits standard 19-inch industrial racks, suitable for data centers and control rooms.
- Long-Distance Connectivity: Supports cable lengths up to 100 meters (328 ft) between the control board and external modules using long-range extension kits.
- Surge and Isolation Protection: Optional transient voltage surge suppression (TVSS) and high-potential isolation for harsh environments.
- Cross-Platform Driver Support: Compatible with Windows NT/95/98/3.x, DOS, UNIX (SCO, SVR4.2, XENIX, Solaris), Linux, OS/2, and QNX.
- Comprehensive Software Tools: Bundled with PComm (Windows) and API-232 (DOS/Windows 3.x) libraries for application development.
- Easy Installation and Configuration: Plug-and-play hardware setup with intuitive driver utilities and configuration panels.
### 3. Technical Specifications
General System Capabilities:
- Up to 32 serial ports per control board
- Up to 4 control boards per PC, totaling 128 ports
- Communication speed: Up to 460.8 Kbps per port
- Interface type: RS-232 (RJ45 connectors)
- Signal lines: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Electrical & Hardware:
- Processor: TMS320C52 RISC CPU (40 MHz)
- UART: 16550C with 32-byte FIFO (Tx + Rx)
- Memory: 512 KB dual-ported DRAM on control board
- ROM/RAM (Module): 16 KB ROM, 32 KWords RAM
- Power Supply: 90–240V AC auto-select via external adapter (optional for long-range setups)
- Power Consumption: Low-power design; external power recommended for cable runs >2 m
- Cable Distance: Up to 100 m (with 10-signal-pin cable and external power)
Physical Characteristics:
- Form Factor: Rackmount module (Extensive type)
- Dimensions: Standard 19” rack width; height and depth vary by configuration (~44 mm x 482 mm x 200 mm typical)
- Weight: Approx. 1.5–2.0 kg per module
- Connectors: 8 × RJ45 female ports, 1 × DB37 link connector (to Basic Module)
- Indicators: Power, TxD, RxD, DTR, DSR, RTS, CTS, DCD LEDs per port
- Material: Industrial-grade metal enclosure
Environmental:
- Operating Temperature: 0°C to 55°C
- Storage Temperature: -20°C to 85°C
- Humidity: 5–95% RH, non-condensing
- EMC Compliance: FCC Class A
### 4. Functionality
The C32082T Extensive Module functions as an expansion unit for the C320 Turbo Control Board and Basic Module. It provides additional RS-232 serial ports for connecting terminals, modems, printers, or other serial devices. Communication between the host PC and the module is managed by the intelligent dual-CPU architecture, which offloads data handling from the host processor.
Use Cases & Applications:
- Industrial automation and process control
- Telecommunications and remote access servers
- Multi-user terminal systems
- Point-of-Sale (POS) and kiosk systems
- Data acquisition and monitoring
- Office automation and serial device networking
Compatibility:
- Works with Moxa C320 Turbo Control Board and C32080T/C32081T Basic Modules
- Supports RS-232 signaling via RJ45 connectors
- Compatible with CN20040 RJ45-to-DB25 test cable and other Moxa accessories
### 5. Components & Accessories
Included Items:
- 1 × C32082T 8-Port RS-232 Extensive Module
- 1 × DB37 link cable (for connection to Basic Module)
- 1 × Rackmount kit (L-type plates and screws)
- 1 × RJ45-to-DB25 test cable (CN20040, 1.5 m)
- 1 × User’s Manual and driver diskettes (Windows, UNIX, DOS)
Optional Accessories:
- Long Range Extension Kit: Includes 10-signal-pin DB25 cable and external power adapter (90–240V AC)
- CN20030 Cable: RJ45-to-female DB25 RS-232 cable for DTE connections
- Fixing Kit: For securing modules in desktop configurations
- Additional Extensive Modules: For port expansion up to 32 ports per control board
Connectors:
- RJ45 Pinout:
1 – DCD
2 – DSR
3 – RTS
4 – GND
5 – TxD
6 – RxD
7 – GND
8 – CTS
9 – DTR
10 – (Reserved)
### 6. Installation & Setup
Requirements:
- Compatible Moxa C320 Turbo Control Board installed in host PC (ISA bus)
- Basic Module (C32080T or C32081T) for initial rackmount connection
- Available rack space (19” standard)
- Proper IRQ and memory address configuration on control board
Mounting Options:
- Rackmount installation using included L-type brackets
- Daisy-chain connection via DB37 cables between Basic and Extensive Modules
Configuration Steps:
1. Power off the PC and modules before installation.
2. Connect the Control Board to the Basic Module using the DB25 link cable.
3. Connect the Basic Module to the C32082T Extensive Module using the DB37-to-DB37 cable.
4. Secure modules in rack using the rackmount kit.
5. Power on the Basic Module, then the PC.
6. Install appropriate drivers for the operating system (Windows, UNIX, DOS).
7. Configure ports using Moxa Configuration Panel or UNIX `mxadm` utility.
LED Indicators:
- Power: Module power status
- TxD/RxD: Data transmission/reception activity
- DTR/DSR/RTS/CTS/DCD: Line control and modem status
### 7. Performance & Capabilities
- Data Rate: Up to 460.8 Kbps per port
- Buffering: 32-byte FIFO per UART (Tx + Rx)
- Flow Control: Hardware (RTS/CTS) and software (XON/XOFF) supported
- Distance: Up to 100 m with long-range kit
- Port Count: 8 ports per module; expandable to 32 ports per control board
- CPU Offload: Dual-processor design minimizes host CPU load
- Reliability: On-chip flow control and buffering prevent data loss under heavy load
- Diagnostics: LED indicators and software utilities for real-time monitoring
Limitations:
- Requires Moxa C320 Turbo Control Board and Basic Module for operation
- RS-232 only (no RS-422/485 support on this module)
- External power required for long cable runs
### 8. Standards & Compliance
- Electrical Safety: Designed for industrial environments with surge and isolation protection options
- EMC Compliance: FCC Class A
- Interface Standards: EIA/TIA RS-232
- Operating System Drivers:
- Windows NT/95/98/3.x
- DOS
- UNIX (SCO UNIX, SVR4.2, XENIX, Solaris x86)
- Linux 2.x, OS/2, QNX (by request)
- Software Libraries:
- PComm (Windows NT/95/98)
- API-232 (DOS/Windows 3.x)
- Extended UNIX ioctl() commands for advanced control
### 9. Additional Information
Warranty & Support:
- Standard Moxa limited warranty (typically 3 years)
- Technical support via email, FTP, and web resources
- Free driver and firmware updates available at [ftp.moxa.com](ftp://ftp.moxa.com)
Maintenance:
- Periodic inspection of cables and connectors recommended
- Firmware updates available through Moxa support
- Diagnostic utilities (PComm, mxadm, SCOPE.EXE) assist in troubleshooting
Software Tools:
- PComm: Windows-based communication library and utilities (diagnostic, monitor, terminal emulator)
- API-232: DOS/Windows 3.x library for serial programming
- mxadm: UNIX administration utility for configuration, monitoring, and terminal emulation
Documentation & Resources:
- Intellio C320 Turbo User’s Manual (4th Edition, Nov. 1999)
- API-232 User’s Manual
- Online manuals and driver downloads via Moxa website
### Summary
The Moxa Intellio C32082T is a robust, high-performance 8-port RS-232 extensive module engineered for industrial and enterprise-grade serial communication systems. As part of the Intellio C320 Turbo family, it integrates seamlessly into modular rackmount configurations, offering scalable connectivity, intelligent processing, and cross-platform driver support. With its dual-CPU architecture, hardware flow control, and comprehensive software ecosystem, the C32082T delivers reliable, high-speed serial communication for demanding applications in automation, telecommunications, and data acquisition environments.
### 1. Product Overview
Product Name: Intellio C32082T
Model: C32082T
Series: Intellio C320 Turbo Series
Article Number: C32082T
Manufacturer: Moxa Technologies Co., Ltd.
Manufacturer Contact:
- Tel: +886-2-8665-6373
- Fax: +886-2-8665-6372
- Website: [www.moxa.com](http://www.moxa.com)
- Support: support@moxa.com.tw
The Moxa Intellio C32082T is an 8-port RS-232 extensive module designed for use with the Intellio C320 Turbo intelligent multiport communication controller system. It provides high-speed serial connectivity through RJ45 connectors and supports data rates up to 460.8 Kbps. The module is part of a modular, expandable system that can scale from 8 to 128 serial ports per PC, offering robust industrial-grade serial communication for automation, telecommunications, and multi-user applications.
### 2. Key Features
- High-Speed Serial Communication: Supports data transfer rates up to 460.8 Kbps per port.
- 8-Port RS-232 Interface: Provides eight independent RS-232 serial ports via RJ45 connectors.
- Modular Expandability: Designed as an Extensive Module for rackmount configurations; can be cascaded with Basic Modules to expand port count.
- Dual RISC Processor Architecture: Utilizes TMS320C52 processors for intelligent offloading of communication tasks from the host CPU.
- On-Chip Hardware Flow Control: Integrated 16550C UARTs with 32-byte FIFO buffers ensure reliable, loss-free data transmission.
- Diagnostic LED Indicators: Front-panel LEDs display per-port line status (TxD, RxD, DTR, DSR, RTS, CTS, DCD).
- Rackmount Design: Fits standard 19-inch industrial racks, suitable for data centers and control rooms.
- Long-Distance Connectivity: Supports cable lengths up to 100 meters (328 ft) between the control board and external modules using long-range extension kits.
- Surge and Isolation Protection: Optional transient voltage surge suppression (TVSS) and high-potential isolation for harsh environments.
- Cross-Platform Driver Support: Compatible with Windows NT/95/98/3.x, DOS, UNIX (SCO, SVR4.2, XENIX, Solaris), Linux, OS/2, and QNX.
- Comprehensive Software Tools: Bundled with PComm (Windows) and API-232 (DOS/Windows 3.x) libraries for application development.
- Easy Installation and Configuration: Plug-and-play hardware setup with intuitive driver utilities and configuration panels.
### 3. Technical Specifications
General System Capabilities:
- Up to 32 serial ports per control board
- Up to 4 control boards per PC, totaling 128 ports
- Communication speed: Up to 460.8 Kbps per port
- Interface type: RS-232 (RJ45 connectors)
- Signal lines: TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Electrical & Hardware:
- Processor: TMS320C52 RISC CPU (40 MHz)
- UART: 16550C with 32-byte FIFO (Tx + Rx)
- Memory: 512 KB dual-ported DRAM on control board
- ROM/RAM (Module): 16 KB ROM, 32 KWords RAM
- Power Supply: 90–240V AC auto-select via external adapter (optional for long-range setups)
- Power Consumption: Low-power design; external power recommended for cable runs >2 m
- Cable Distance: Up to 100 m (with 10-signal-pin cable and external power)
Physical Characteristics:
- Form Factor: Rackmount module (Extensive type)
- Dimensions: Standard 19” rack width; height and depth vary by configuration (~44 mm x 482 mm x 200 mm typical)
- Weight: Approx. 1.5–2.0 kg per module
- Connectors: 8 × RJ45 female ports, 1 × DB37 link connector (to Basic Module)
- Indicators: Power, TxD, RxD, DTR, DSR, RTS, CTS, DCD LEDs per port
- Material: Industrial-grade metal enclosure
Environmental:
- Operating Temperature: 0°C to 55°C
- Storage Temperature: -20°C to 85°C
- Humidity: 5–95% RH, non-condensing
- EMC Compliance: FCC Class A
### 4. Functionality
The C32082T Extensive Module functions as an expansion unit for the C320 Turbo Control Board and Basic Module. It provides additional RS-232 serial ports for connecting terminals, modems, printers, or other serial devices. Communication between the host PC and the module is managed by the intelligent dual-CPU architecture, which offloads data handling from the host processor.
Use Cases & Applications:
- Industrial automation and process control
- Telecommunications and remote access servers
- Multi-user terminal systems
- Point-of-Sale (POS) and kiosk systems
- Data acquisition and monitoring
- Office automation and serial device networking
Compatibility:
- Works with Moxa C320 Turbo Control Board and C32080T/C32081T Basic Modules
- Supports RS-232 signaling via RJ45 connectors
- Compatible with CN20040 RJ45-to-DB25 test cable and other Moxa accessories
### 5. Components & Accessories
Included Items:
- 1 × C32082T 8-Port RS-232 Extensive Module
- 1 × DB37 link cable (for connection to Basic Module)
- 1 × Rackmount kit (L-type plates and screws)
- 1 × RJ45-to-DB25 test cable (CN20040, 1.5 m)
- 1 × User’s Manual and driver diskettes (Windows, UNIX, DOS)
Optional Accessories:
- Long Range Extension Kit: Includes 10-signal-pin DB25 cable and external power adapter (90–240V AC)
- CN20030 Cable: RJ45-to-female DB25 RS-232 cable for DTE connections
- Fixing Kit: For securing modules in desktop configurations
- Additional Extensive Modules: For port expansion up to 32 ports per control board
Connectors:
- RJ45 Pinout:
1 – DCD
2 – DSR
3 – RTS
4 – GND
5 – TxD
6 – RxD
7 – GND
8 – CTS
9 – DTR
10 – (Reserved)
### 6. Installation & Setup
Requirements:
- Compatible Moxa C320 Turbo Control Board installed in host PC (ISA bus)
- Basic Module (C32080T or C32081T) for initial rackmount connection
- Available rack space (19” standard)
- Proper IRQ and memory address configuration on control board
Mounting Options:
- Rackmount installation using included L-type brackets
- Daisy-chain connection via DB37 cables between Basic and Extensive Modules
Configuration Steps:
1. Power off the PC and modules before installation.
2. Connect the Control Board to the Basic Module using the DB25 link cable.
3. Connect the Basic Module to the C32082T Extensive Module using the DB37-to-DB37 cable.
4. Secure modules in rack using the rackmount kit.
5. Power on the Basic Module, then the PC.
6. Install appropriate drivers for the operating system (Windows, UNIX, DOS).
7. Configure ports using Moxa Configuration Panel or UNIX `mxadm` utility.
LED Indicators:
- Power: Module power status
- TxD/RxD: Data transmission/reception activity
- DTR/DSR/RTS/CTS/DCD: Line control and modem status
### 7. Performance & Capabilities
- Data Rate: Up to 460.8 Kbps per port
- Buffering: 32-byte FIFO per UART (Tx + Rx)
- Flow Control: Hardware (RTS/CTS) and software (XON/XOFF) supported
- Distance: Up to 100 m with long-range kit
- Port Count: 8 ports per module; expandable to 32 ports per control board
- CPU Offload: Dual-processor design minimizes host CPU load
- Reliability: On-chip flow control and buffering prevent data loss under heavy load
- Diagnostics: LED indicators and software utilities for real-time monitoring
Limitations:
- Requires Moxa C320 Turbo Control Board and Basic Module for operation
- RS-232 only (no RS-422/485 support on this module)
- External power required for long cable runs
### 8. Standards & Compliance
- Electrical Safety: Designed for industrial environments with surge and isolation protection options
- EMC Compliance: FCC Class A
- Interface Standards: EIA/TIA RS-232
- Operating System Drivers:
- Windows NT/95/98/3.x
- DOS
- UNIX (SCO UNIX, SVR4.2, XENIX, Solaris x86)
- Linux 2.x, OS/2, QNX (by request)
- Software Libraries:
- PComm (Windows NT/95/98)
- API-232 (DOS/Windows 3.x)
- Extended UNIX ioctl() commands for advanced control
### 9. Additional Information
Warranty & Support:
- Standard Moxa limited warranty (typically 3 years)
- Technical support via email, FTP, and web resources
- Free driver and firmware updates available at [ftp.moxa.com](ftp://ftp.moxa.com)
Maintenance:
- Periodic inspection of cables and connectors recommended
- Firmware updates available through Moxa support
- Diagnostic utilities (PComm, mxadm, SCOPE.EXE) assist in troubleshooting
Software Tools:
- PComm: Windows-based communication library and utilities (diagnostic, monitor, terminal emulator)
- API-232: DOS/Windows 3.x library for serial programming
- mxadm: UNIX administration utility for configuration, monitoring, and terminal emulation
Documentation & Resources:
- Intellio C320 Turbo User’s Manual (4th Edition, Nov. 1999)
- API-232 User’s Manual
- Online manuals and driver downloads via Moxa website
### Summary
The Moxa Intellio C32082T is a robust, high-performance 8-port RS-232 extensive module engineered for industrial and enterprise-grade serial communication systems. As part of the Intellio C320 Turbo family, it integrates seamlessly into modular rackmount configurations, offering scalable connectivity, intelligent processing, and cross-platform driver support. With its dual-CPU architecture, hardware flow control, and comprehensive software ecosystem, the C32082T delivers reliable, high-speed serial communication for demanding applications in automation, telecommunications, and data acquisition environments.
-
C320Turbo.pdf
Manual