LOOKING FOR THE RIGHT

INDUSTRIAL SOLUTION?

Discover embedded, communication and automation solutions tailored to your application.

DBU-01-M12

Configuration back up unit for M12 type console port
107,00 EUR

including VAT 127.33 EUR

  • Manufacturer Oring
  • Category: FX Patch Cords
  • The ORing DBU-01-M12 is a compact, industrial-grade configuration backup and restore device designed for use with ORing’s networking equipment, including managed switches, access points (APs), and access routers (ARs). It enables users to back up and restore configuration data directly through the console port without requiring a PC or external software. The M12 variant is specifically equipped with a 5-pin A-coded M12 connector, ensuring robust connectivity in industrial environments where vibration, dust, and moisture resistance are critical.
- Standalone Configuration Backup/Restore:
Operates independently without a PC or notebook, allowing direct configuration management through the console port.

- Connector Type:
M12 (5-pin, A-coding) interface for rugged industrial connectivity. Other variants in the series include DB9 and RJ45 connectors.

- Power Supply via Console Port:
Draws 5–12 VDC power directly from the connected ORing device through the RS-232 RTS signal—no external power adapter required.

- Simple Operation via DIP Switch:
Two-pole DIP switch enables easy selection between upload (backup) and download (restore) modes.

- LED Indicators for Status Monitoring:
- Power LED (Green): Indicates device readiness.
- Transmit LED (Amber): Blinks during data transfer.
- Status LED (Green/Red): Green indicates successful transmission; red indicates failure.

- Compact and Lightweight Design:
Small form factor (32 × 14.5 × 90 mm) and lightweight (53 g) for easy handling and portability.

- Industrial-Grade Enclosure:
IP40-rated PC molding enclosure provides protection against solid objects and ensures durability in industrial environments.

- Dual Configuration Storage (A & B):
Two configuration memory slots allow users to store and manage multiple device configurations.

- Quick Start Button:
Dedicated “Start” button initiates upload or download operations after connection.

- Wide Operating Temperature Range:
Designed for industrial conditions, operating from -10°C to 60°C (14°F to 140°F).

- Regulatory Compliance:
Meets FCC Part 15, CISPR (EN55022) Class A, and multiple EN61000-4 EMC standards for electromagnetic compatibility and immunity.

Country of origin: Taiwan R.O.C.

Comprehensive Product Summary – ORing DBU-01-M12 Configuration Backup Unit
*(Approx. 12,000 characters / ~3,000 tokens)*




### 1. Product Overview

Product Name: Configuration Backup Unit for M12 Type Console Port
Model: DBU-01-M12
Series: DBU-01 Series
Article Number: DBU-01-M12
Manufacturer: ORing Industrial Networking Corp.
Version: 1.0

The ORing DBU-01-M12 is a compact, industrial-grade configuration backup and restore device designed for use with ORing’s networking equipment, including managed switches, access points (APs), and access routers (ARs). It enables users to back up and restore configuration data directly through the console port without requiring a PC or external software. The M12 variant is specifically equipped with a 5-pin A-coded M12 connector, ensuring robust connectivity in industrial environments where vibration, dust, and moisture resistance are critical.

This standalone unit is powered directly through the console port (via RS-232 RTS signal), eliminating the need for an external power supply. Its plug-and-play design, DIP switch operation, and LED status indicators make it an efficient and user-friendly tool for field technicians and system integrators managing ORing industrial networking devices.




### 2. Key Features

- Standalone Configuration Backup/Restore:
Operates independently without a PC or notebook, allowing direct configuration management through the console port.

- Connector Type:
M12 (5-pin, A-coding) interface for rugged industrial connectivity. Other variants in the series include DB9 and RJ45 connectors.

- Power Supply via Console Port:
Draws 5–12 VDC power directly from the connected ORing device through the RS-232 RTS signal—no external power adapter required.

- Simple Operation via DIP Switch:
Two-pole DIP switch enables easy selection between upload (backup) and download (restore) modes.

- LED Indicators for Status Monitoring:
- Power LED (Green): Indicates device readiness.
- Transmit LED (Amber): Blinks during data transfer.
- Status LED (Green/Red): Green indicates successful transmission; red indicates failure.

- Compact and Lightweight Design:
Small form factor (32 × 14.5 × 90 mm) and lightweight (53 g) for easy handling and portability.

- Industrial-Grade Enclosure:
IP40-rated PC molding enclosure provides protection against solid objects and ensures durability in industrial environments.

- Dual Configuration Storage (A & B):
Two configuration memory slots allow users to store and manage multiple device configurations.

- Quick Start Button:
Dedicated “Start” button initiates upload or download operations after connection.

- Wide Operating Temperature Range:
Designed for industrial conditions, operating from -10°C to 60°C (14°F to 140°F).

- Regulatory Compliance:
Meets FCC Part 15, CISPR (EN55022) Class A, and multiple EN61000-4 EMC standards for electromagnetic compatibility and immunity.




### 3. Technical Specifications

| Parameter | Specification |
|----------------|-------------------|
| Model | DBU-01-M12 |
| Series | DBU-01 Series |
| Connector Type | M12 (5-pin, A-coding) |
| Switch Type | 2-pole DIP switch |
| LED Indicators | Power (Green), Transmit (Amber), Status (Green/Red) |
| Power Input | 5–12 VDC (via RS-232 RTS signal) |
| Enclosure | IP40-rated PC molding |
| Dimensions (W × D × H) | 32 × 14.5 × 90 mm (1.25 × 0.57 × 3.5 in.) |
| Cable Length | 172 mm |
| Weight | 53 g |
| Operating Temperature | -10°C to 60°C (14°F to 140°F) |
| Storage Temperature | -40°C to 85°C (-40°F to 185°F) |
| Operating Humidity | 5% to 95% non-condensing |
| EMI Compliance | FCC Part 15, CISPR (EN55022) Class A |
| EMS Compliance | EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11 |
| Warranty | 5 years |
| Manufacturer Contact | ORing Industrial Networking Corp., Taiwan |
| Website | [www.oring-networking.com](https://www.oring-networking.com) |




### 4. Functionality

The DBU-01-M12 functions as a configuration backup and restore unit for ORing’s industrial networking devices. It connects directly to the console port of a compatible device using its M12 connector. Once connected, the unit draws power from the host device and becomes operational immediately.

Operational Workflow:
1. Connection:
Plug the M12 connector into the console port of the ORing switch, AP, or AR.
2. Power Verification:
The green Power LED lights up, confirming that the device is powered and ready.
3. Mode Selection:
Use the DIP switch to select either Upload (Backup) or Download (Restore) mode.
4. Initiation:
Press the Start button to begin the selected operation.
5. Status Monitoring:
- Amber LED blinks during data transfer.
- Green LED indicates successful completion.
- Red LED signals a transmission failure.
6. Dual Configuration Storage:
The A/B configuration selector allows users to store two separate configuration sets, enabling quick switching between device setups.

Use Cases and Applications:
- Rapid configuration deployment across multiple ORing devices in industrial networks.
- Field maintenance and recovery of managed switches, APs, and routers.
- Backup of critical network configurations before firmware updates or system changes.
- Simplified configuration cloning for large-scale industrial automation systems.

Compatibility:
The DBU-01-M12 is compatible with specific ORing devices equipped with M12 console ports. Users should refer to the official ORing datasheet for the list of supported models.




### 5. Components & Accessories

Package Contents:
- 1 × DBU-01-M12 Configuration Backup Unit
- 1 × Quick Installation Guide (QIG)

Optional Accessories (Series Variants):
- DBU-01-DB9: For devices with DB9 console ports.
- DBU-01-RJ45: For devices with RJ45 console ports.
- DBU-01-M12: For devices with M12 console ports (this model).

Integrated Components:
- M12 (5-pin A-coded) Connector Cable (172 mm length)
- 2-pole DIP Switch for upload/download selection.
- Start Button for initiating operations.
- LED Indicators: Power, Transmit, and Status.
- Configuration Selector (A/B) for dual configuration storage.

No external power supply, cables, or software are required for operation.




### 6. Installation & Setup

Pre-Installation Requirements:
- Ensure the target ORing device supports configuration backup via console port.
- Verify that the device is powered on and operational.
- Confirm that the DBU-01-M12 connector type matches the console port (M12, 5-pin A-coded).

Installation Steps:
1. Connect the Device:
Insert the M12 connector into the console port of the ORing switch, AP, or AR.
2. Power Check:
The Power LED (green) should illuminate, indicating that the unit is receiving power.
3. Select Operation Mode:
Use the DIP switch to choose between Upload (Backup) or Download (Restore).
4. Initiate Process:
Press the Start button to begin the operation.
5. Monitor LEDs:
- Amber LED blinks during data transfer.
- Green LED indicates success.
- Red LED indicates failure.
6. Switch Configuration Slot (Optional):
Use the A/B selector to manage multiple configuration sets.

Safety & Warnings:
- The device is not waterproof; avoid exposure to liquids.
- Operate only within the specified temperature and humidity ranges.
- Use only with compatible ORing devices to prevent malfunction.

Mounting Options:
The DBU-01-M12 is designed for handheld or temporary connection use. It does not require permanent mounting or additional brackets.




### 7. Performance & Capabilities

Operational Efficiency:
- Power Efficiency: Draws minimal current from the host device (5–12 VDC via RS-232 RTS signal).
- Data Transfer Speed: Optimized for configuration file transfer through RS-232 interface; actual speed depends on device console port settings.
- Reliability: LED feedback ensures clear indication of operation status, minimizing configuration errors.

Capacity:
- Supports storage of two independent configuration sets (A and B).
- Sufficient internal memory to handle full configuration data from supported ORing devices.

Limitations:
- Only compatible with ORing devices featuring console ports (DB9, RJ45, or M12 depending on model).
- Not designed for continuous operation or environmental exposure beyond IP40 rating.
- Does not support configuration editing or viewing—functions solely as a backup/restore tool.

Industrial Suitability:
- Designed for field engineers and maintenance personnel in industrial automation, transportation, and energy sectors.
- Ideal for environments requiring quick configuration replication or recovery without network downtime.




### 8. Standards & Compliance

The DBU-01-M12 meets multiple international standards for electromagnetic compatibility and industrial safety:

EMI (Electromagnetic Interference):
- FCC Part 15, Class A
- CISPR (EN55022) Class A

EMS (Electromagnetic Susceptibility):
- EN61000-4-2: Electrostatic Discharge (ESD)
- EN61000-4-3: Radiated Susceptibility (RS)
- EN61000-4-4: Electrical Fast Transient (EFT)
- EN61000-4-5: Surge Immunity
- EN61000-4-6: Conducted Susceptibility (CS)
- EN61000-4-8: Power Frequency Magnetic Field
- EN61000-4-11: Voltage Dips and Interruptions

Environmental Protection:
- IP40 Enclosure Rating: Protection against solid objects larger than 1 mm; not protected against liquids.

Quality and Manufacturing Standards:
- Manufactured under ORing’s industrial-grade quality control processes.
- Complies with RoHS and CE directives (implied by EMC compliance).




### 9. Additional Information

Warranty:
5-year limited warranty covering manufacturing defects and hardware failures under normal operating conditions.

Maintenance:
- No user-serviceable parts inside.
- Clean with a dry, lint-free cloth.
- Avoid exposure to moisture or corrosive environments.

Support & Service:
- Technical Support: support@oring-networking.com
- Telephone: +886-2-2218-1066
- Fax: +886-2-2218-1014
- Website: [www.oring-networking.com](https://www.oring-networking.com)

Documentation:
- Quick Installation Guide (QIG) included in package.
- Additional datasheets and compatibility lists available on the manufacturer’s website.

Product Identification:
- Document Code: 1907-2-29-DBU01-1.0
- Printed on Recycled Paper (environmentally conscious packaging).

Manufacturer Address:
ORing Industrial Networking Corp.
Taipei, Taiwan




### Summary

The ORing DBU-01-M12 Configuration Backup Unit is a purpose-built, industrial-grade device that simplifies configuration management for ORing’s network infrastructure products. Its M12 connector ensures secure and reliable operation in harsh environments, while its self-powered design and intuitive DIP switch interface provide a seamless, PC-free solution for configuration backup and restoration.

With dual configuration storage, LED status indicators, and compliance with stringent EMC standards, the DBU-01-M12 is an essential tool for network administrators and field engineers seeking efficient, reliable, and portable configuration management in industrial networking applications.

---
End of Product Summary – ORing DBU-01-M12

No accessories available.