LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
High-Performance Network Switching
- Eight-port managed Ethernet switch supporting 10/100BaseT(X) and 100BaseFX (single-mode fiber).
- Store-and-forward switching architecture with a 4096-entry MAC address table.
- Full/Half-duplex operation with auto-negotiation and MDI/MDI-X auto-sensing.
- IEEE 802.3, 802.3u, 802.3x, and 802.1D compliant for seamless interoperability.
- SNMP v1/v2c, DHCP Server/Client, BootP, RARP, and SMTP protocol support.
Redundant Network Reliability
- MOXA Turbo Ring™ technology for redundant Ethernet ring topology with recovery time under 300 ms (at full load with up to 120 nodes).
- Patented Line-Swap Fast Recovery (<1 second) for rapid reconnection when network topology changes.
- Dual redundant DC power inputs for uninterrupted operation.
- Automatic IP address recovery for connected devices.
Industrial-Grade Design
- Rugged IP30-rated aluminum housing for mechanical durability.
- Wide operating temperature range (0–60°C standard; -40–75°C for -T models).
- Designed for hazardous locations (UL/cUL Class 1, Division 2, and ATEX Zone 2 certified).
- DIN-rail and wall-mount installation options.
Advanced Monitoring and Management
- Web browser, Telnet, serial console, and Windows utility configuration.
- Port mirroring for real-time diagnostics and debugging.
- Event-based e-mail and relay alarms for power, link, and configuration changes.
- Integration with EDS-SNMP OPC Server Pro for SCADA/OPC-based network management.
Ease of Integration
- Compatible with standard industrial Ethernet devices and SCADA systems.
- Supports MIB-II, Ethernet-Like MIB, and Bridge MIB for SNMP-based monitoring.
- Batch configuration utility for multi-device setup and parameter synchronization.
- Eight-port managed Ethernet switch supporting 10/100BaseT(X) and 100BaseFX (single-mode fiber).
- Store-and-forward switching architecture with a 4096-entry MAC address table.
- Full/Half-duplex operation with auto-negotiation and MDI/MDI-X auto-sensing.
- IEEE 802.3, 802.3u, 802.3x, and 802.1D compliant for seamless interoperability.
- SNMP v1/v2c, DHCP Server/Client, BootP, RARP, and SMTP protocol support.
Redundant Network Reliability
- MOXA Turbo Ring™ technology for redundant Ethernet ring topology with recovery time under 300 ms (at full load with up to 120 nodes).
- Patented Line-Swap Fast Recovery (<1 second) for rapid reconnection when network topology changes.
- Dual redundant DC power inputs for uninterrupted operation.
- Automatic IP address recovery for connected devices.
Industrial-Grade Design
- Rugged IP30-rated aluminum housing for mechanical durability.
- Wide operating temperature range (0–60°C standard; -40–75°C for -T models).
- Designed for hazardous locations (UL/cUL Class 1, Division 2, and ATEX Zone 2 certified).
- DIN-rail and wall-mount installation options.
Advanced Monitoring and Management
- Web browser, Telnet, serial console, and Windows utility configuration.
- Port mirroring for real-time diagnostics and debugging.
- Event-based e-mail and relay alarms for power, link, and configuration changes.
- Integration with EDS-SNMP OPC Server Pro for SCADA/OPC-based network management.
Ease of Integration
- Compatible with standard industrial Ethernet devices and SCADA systems.
- Supports MIB-II, Ethernet-Like MIB, and Bridge MIB for SNMP-based monitoring.
- Batch configuration utility for multi-device setup and parameter synchronization.
Comprehensive Product Summary – MOXA EtherDevice™ Switch ED6008-SS-SC
### 1. Product Overview
Product Name: EtherDevice™ Managed Redundant Industrial Ethernet Switch
Model: ED6008-SS-SC
Series: ED6008 Series
Article Number: ED6008-SS-SC
Manufacturer: MOXA Inc.
The MOXA ED6008-SS-SC is an industrial-grade, managed, redundant Ethernet device server designed for high-reliability networking in automation and control environments. As part of the EtherDevice™ ED6008 Series, this model integrates advanced redundancy, management, and diagnostic features to ensure continuous network operation in mission-critical industrial systems. It provides eight Ethernet ports—six 10/100BaseT(X) copper ports and two single-mode 100BaseFX fiber ports—optimized for long-distance, noise-immune communication. The device is engineered for rugged environments, supporting wide temperature ranges, redundant power inputs, and compliance with multiple industrial safety and EMC standards.
### 2. Key Features
High-Performance Network Switching
- Eight-port managed Ethernet switch supporting 10/100BaseT(X) and 100BaseFX (single-mode fiber).
- Store-and-forward switching architecture with a 4096-entry MAC address table.
- Full/Half-duplex operation with auto-negotiation and MDI/MDI-X auto-sensing.
- IEEE 802.3, 802.3u, 802.3x, and 802.1D compliant for seamless interoperability.
- SNMP v1/v2c, DHCP Server/Client, BootP, RARP, and SMTP protocol support.
Redundant Network Reliability
- MOXA Turbo Ring™ technology for redundant Ethernet ring topology with recovery time under 300 ms (at full load with up to 120 nodes).
- Patented Line-Swap Fast Recovery (<1 second) for rapid reconnection when network topology changes.
- Dual redundant DC power inputs for uninterrupted operation.
- Automatic IP address recovery for connected devices.
Industrial-Grade Design
- Rugged IP30-rated aluminum housing for mechanical durability.
- Wide operating temperature range (0–60°C standard; -40–75°C for -T models).
- Designed for hazardous locations (UL/cUL Class 1, Division 2, and ATEX Zone 2 certified).
- DIN-rail and wall-mount installation options.
Advanced Monitoring and Management
- Web browser, Telnet, serial console, and Windows utility configuration.
- Port mirroring for real-time diagnostics and debugging.
- Event-based e-mail and relay alarms for power, link, and configuration changes.
- Integration with EDS-SNMP OPC Server Pro for SCADA/OPC-based network management.
Ease of Integration
- Compatible with standard industrial Ethernet devices and SCADA systems.
- Supports MIB-II, Ethernet-Like MIB, and Bridge MIB for SNMP-based monitoring.
- Batch configuration utility for multi-device setup and parameter synchronization.
### 3. Technical Specifications
Technology and Standards
- IEEE Standards: 802.3 (Ethernet), 802.3u (Fast Ethernet), 802.3x (Flow Control), 802.1D (Spanning Tree Protocol)
- Protocols: SNMP v1/v2c, DHCP Server/Client, BootP, RARP, SMTP
- MIB Support: MIB-II, Ethernet-Like MIB, Bridge MIB
- Switching Method: Store-and-forward
- MAC Address Table: 4096 entries
- Flow Control: IEEE 802.3x (full-duplex), back pressure (half-duplex)
Interfaces
- Copper Ports: 6 × 10/100BaseT(X) RJ45 ports (auto-negotiation, auto MDI/MDI-X)
- Fiber Ports: 2 × 100BaseFX single-mode SC connectors
- Console Port: 1 × RS-232 (RJ45)
- Alarm Contact: 1 × relay output, 1A @ 24 VDC
- LED Indicators: P1, P2, Fault, 10/100 LNK/ACT
Optical Fiber Characteristics
- Transmission Distance: Up to 15 km (single-mode)
- Wavelength: 1310 nm
- TX Output Power: -15 dBm (min), -6 dBm (max)
- Receiver Sensitivity: -36 to -32 dBm
- Connector Type: SC
Power Requirements
- Input Voltage: 24 VDC nominal (9–32 VDC for pre-v2.0 units; 12–48 VDC for v2.0 and later)
- Input Current (@24V): 0.55 A typical
- Power Connection: Removable terminal block (max cable diameter 1.5 mm)
- Protection: Reverse polarity protection, thermal fuse (<2.5 A)
- Power Redundancy: Dual DC inputs
Mechanical
- Casing: Aluminum, IP30 protection
- Dimensions: 51.8 × 136.7 × 101.2 mm (W × H × D)
- Weight: 0.57 kg
- Mounting: DIN-rail or wall mount
Environmental
- Operating Temperature: 0–60°C (standard), -40–75°C (-T models)
- Storage Temperature: -40–85°C
- Humidity: 5–95% RH (non-condensing)
- MTBF: 230,000 hours (MIL-HDBK-217F, GB database)
### 4. Functionality
The ED6008-SS-SC functions as a managed Ethernet switch designed for industrial automation networks requiring high reliability and redundancy. It connects multiple Ethernet-enabled devices—such as PLCs, HMIs, sensors, and controllers—within a local industrial network. The device supports both copper and fiber connections, enabling flexible network topologies and long-distance communication.
Operational Modes and Use Cases
- Redundant Ring Networks: Turbo Ring™ ensures sub-300 ms recovery in case of link failure, maintaining continuous communication for SCADA and control systems.
- Device Replacement: DHCP/BootP and RARP protocols automatically reassign IP addresses to replacement devices, minimizing downtime.
- Network Diagnostics: Port mirroring and ping utilities allow real-time monitoring and troubleshooting.
- Event Notification: Configurable e-mail and relay alarms alert operators to power failures, link loss, or configuration changes.
Applications
- Factory automation and process control
- Power generation and distribution networks
- Transportation and traffic control systems
- Oil, gas, and petrochemical facilities
- Water and wastewater treatment plants
- Building automation and security systems
Compatibility
- Fully interoperable with standard Ethernet devices and industrial protocols.
- Integrates with SNMP-based network management systems and OPC-compatible SCADA software.
### 5. Components & Accessories
Included Items
- ED6008-SS-SC switch unit
- User’s manual and documentation
- DIN-rail mounting kit
Optional Accessories
- Power Supplies:
- DR-4524: 45W/2A DIN-rail 24 VDC power supply (85–264 VAC input)
- DR-75-24: 75W/3.2A DIN-rail 24 VDC power supply (85–264 VAC input)
- DR-120-24: 120W/5A DIN-rail 24 VDC power supply (88–132 VAC / 176–264 VAC input)
- Software:
- EDS-SNMP OPC Server Pro (CD with software and manual) for SNMP-to-OPC integration
Connectors
- RJ45 connectors for copper Ethernet ports
- SC connectors for fiber ports
- Removable terminal block for power input
- RJ45 console port for serial management
### 6. Installation & Setup
Installation Requirements
- 24 VDC power source (redundant inputs recommended)
- DIN-rail or wall-mount surface
- Proper grounding and shielding for industrial environments
Mounting Options
- DIN-Rail Mounting: Standard 35 mm DIN-rail clip for quick installation in control cabinets.
- Wall Mounting: Optional brackets for panel or enclosure mounting.
Configuration Interfaces
- Web Browser: Intuitive GUI for configuration and monitoring.
- Telnet/Serial Console: Command-line interface for advanced setup.
- Windows Utility: Moxa’s configuration software for batch setup and parameter management.
- Batch Configurator: Enables import/export of configuration files across multiple devices.
Setup Process
1. Mount the device on DIN-rail or wall surface.
2. Connect power inputs (P1 and P2) for redundancy.
3. Connect Ethernet and fiber cables to respective ports.
4. Access the device via web browser or console for initial configuration.
5. Configure IP settings, VLANs, redundancy, and alarm parameters.
6. Verify network connectivity and redundancy status.
### 7. Performance & Capabilities
Switching Performance
- Store-and-forward architecture ensures reliable data transmission.
- 4096 MAC address entries support large-scale industrial networks.
- Full wire-speed switching for 10/100 Mbps traffic.
Redundancy and Recovery
- Turbo Ring™ recovery time <300 ms under full load.
- Line-Swap Fast Recovery <1 second for topology changes.
- Dual power inputs ensure continuous operation during power source failure.
Capacity and Efficiency
- Supports up to 8 simultaneous Ethernet connections.
- Fiber ports extend network reach up to 15 km.
- Efficient thermal design for continuous operation in high-temperature environments.
Limitations
- 100 Mbps maximum per port (no Gigabit support).
- Limited to 8 ports; expansion requires additional switches.
- Management features optimized for Ethernet-based automation (no PoE support).
### 8. Standards & Compliance
Safety Certifications
- UL60950 (E212360)
- UL508
- CSA C22.2 No. 60950
- EN60950
Hazardous Location Approvals
- UL/cUL Class 1, Division 2, Groups A, B, C, D (E238559)
- ATEX Class 1, Zone 2, EEx nC IIC (03CA24537)
EMI/EMS Compliance
- EMI: FCC Part 15, CISPR (EN55022) Class A
- EMS:
- EN61000-4-2 (ESD) Level 3
- EN61000-4-3 (RS) Level 3
- EN61000-4-4 (EFT) Level 3
- EN61000-4-5 (Surge) Level 3
- EN61000-4-6 (CS) Level 3
Environmental and Mechanical Standards
- Shock: IEC60068-2-27
- Vibration: IEC60068-2-6
- Free Fall: IEC60068-2-32
Reliability
- MTBF: 230,000 hours (MIL-HDBK-217F, GB database)
- Designed for continuous 24/7 operation in industrial environments.
### 9. Additional Information
Warranty and Support
- Warranty: 5 years standard manufacturer warranty.
- Technical Support: Available via MOXA’s global support network and online resources.
- Firmware Updates: Provided through MOXA’s website for enhanced functionality and security.
Maintenance
- Minimal maintenance required due to fanless, solid-state design.
- Periodic inspection of power and network connections recommended.
- Firmware updates can be applied remotely via web or Telnet interface.
Software Integration
- EDS-SNMP OPC Server Pro: Converts SNMP data into OPC format for integration with SCADA systems.
- Network Management: Supports SNMP-based monitoring and event logging for proactive maintenance.
Extended Temperature Models
- For extreme environments, the ED6008-SS-SC-T variant supports -40 to 75°C operation.
Ordering Information
- ED6008-SS-SC: 6 × 10/100BaseT(X) + 2 × 100BaseFX (single-mode SC), 0–60°C
- ED6008-SS-SC-T: Same configuration, extended temperature (-40–75°C)
### Summary
The MOXA ED6008-SS-SC is a robust, managed, redundant Ethernet switch engineered for industrial automation networks demanding high reliability, redundancy, and long-distance communication. With dual single-mode fiber ports, six copper ports, and advanced management capabilities, it ensures continuous operation even under adverse conditions. Its compliance with global safety and EMC standards, combined with MOXA’s Turbo Ring™ redundancy and Line-Swap Fast Recovery technologies, make it a trusted solution for mission-critical industrial Ethernet infrastructures.
This model’s combination of rugged hardware, intelligent management, and flexible configuration options positions it as a cornerstone component for modern industrial Ethernet networks, ensuring uptime, scalability, and operational resilience across diverse industrial sectors.
### 1. Product Overview
Product Name: EtherDevice™ Managed Redundant Industrial Ethernet Switch
Model: ED6008-SS-SC
Series: ED6008 Series
Article Number: ED6008-SS-SC
Manufacturer: MOXA Inc.
The MOXA ED6008-SS-SC is an industrial-grade, managed, redundant Ethernet device server designed for high-reliability networking in automation and control environments. As part of the EtherDevice™ ED6008 Series, this model integrates advanced redundancy, management, and diagnostic features to ensure continuous network operation in mission-critical industrial systems. It provides eight Ethernet ports—six 10/100BaseT(X) copper ports and two single-mode 100BaseFX fiber ports—optimized for long-distance, noise-immune communication. The device is engineered for rugged environments, supporting wide temperature ranges, redundant power inputs, and compliance with multiple industrial safety and EMC standards.
### 2. Key Features
High-Performance Network Switching
- Eight-port managed Ethernet switch supporting 10/100BaseT(X) and 100BaseFX (single-mode fiber).
- Store-and-forward switching architecture with a 4096-entry MAC address table.
- Full/Half-duplex operation with auto-negotiation and MDI/MDI-X auto-sensing.
- IEEE 802.3, 802.3u, 802.3x, and 802.1D compliant for seamless interoperability.
- SNMP v1/v2c, DHCP Server/Client, BootP, RARP, and SMTP protocol support.
Redundant Network Reliability
- MOXA Turbo Ring™ technology for redundant Ethernet ring topology with recovery time under 300 ms (at full load with up to 120 nodes).
- Patented Line-Swap Fast Recovery (<1 second) for rapid reconnection when network topology changes.
- Dual redundant DC power inputs for uninterrupted operation.
- Automatic IP address recovery for connected devices.
Industrial-Grade Design
- Rugged IP30-rated aluminum housing for mechanical durability.
- Wide operating temperature range (0–60°C standard; -40–75°C for -T models).
- Designed for hazardous locations (UL/cUL Class 1, Division 2, and ATEX Zone 2 certified).
- DIN-rail and wall-mount installation options.
Advanced Monitoring and Management
- Web browser, Telnet, serial console, and Windows utility configuration.
- Port mirroring for real-time diagnostics and debugging.
- Event-based e-mail and relay alarms for power, link, and configuration changes.
- Integration with EDS-SNMP OPC Server Pro for SCADA/OPC-based network management.
Ease of Integration
- Compatible with standard industrial Ethernet devices and SCADA systems.
- Supports MIB-II, Ethernet-Like MIB, and Bridge MIB for SNMP-based monitoring.
- Batch configuration utility for multi-device setup and parameter synchronization.
### 3. Technical Specifications
Technology and Standards
- IEEE Standards: 802.3 (Ethernet), 802.3u (Fast Ethernet), 802.3x (Flow Control), 802.1D (Spanning Tree Protocol)
- Protocols: SNMP v1/v2c, DHCP Server/Client, BootP, RARP, SMTP
- MIB Support: MIB-II, Ethernet-Like MIB, Bridge MIB
- Switching Method: Store-and-forward
- MAC Address Table: 4096 entries
- Flow Control: IEEE 802.3x (full-duplex), back pressure (half-duplex)
Interfaces
- Copper Ports: 6 × 10/100BaseT(X) RJ45 ports (auto-negotiation, auto MDI/MDI-X)
- Fiber Ports: 2 × 100BaseFX single-mode SC connectors
- Console Port: 1 × RS-232 (RJ45)
- Alarm Contact: 1 × relay output, 1A @ 24 VDC
- LED Indicators: P1, P2, Fault, 10/100 LNK/ACT
Optical Fiber Characteristics
- Transmission Distance: Up to 15 km (single-mode)
- Wavelength: 1310 nm
- TX Output Power: -15 dBm (min), -6 dBm (max)
- Receiver Sensitivity: -36 to -32 dBm
- Connector Type: SC
Power Requirements
- Input Voltage: 24 VDC nominal (9–32 VDC for pre-v2.0 units; 12–48 VDC for v2.0 and later)
- Input Current (@24V): 0.55 A typical
- Power Connection: Removable terminal block (max cable diameter 1.5 mm)
- Protection: Reverse polarity protection, thermal fuse (<2.5 A)
- Power Redundancy: Dual DC inputs
Mechanical
- Casing: Aluminum, IP30 protection
- Dimensions: 51.8 × 136.7 × 101.2 mm (W × H × D)
- Weight: 0.57 kg
- Mounting: DIN-rail or wall mount
Environmental
- Operating Temperature: 0–60°C (standard), -40–75°C (-T models)
- Storage Temperature: -40–85°C
- Humidity: 5–95% RH (non-condensing)
- MTBF: 230,000 hours (MIL-HDBK-217F, GB database)
### 4. Functionality
The ED6008-SS-SC functions as a managed Ethernet switch designed for industrial automation networks requiring high reliability and redundancy. It connects multiple Ethernet-enabled devices—such as PLCs, HMIs, sensors, and controllers—within a local industrial network. The device supports both copper and fiber connections, enabling flexible network topologies and long-distance communication.
Operational Modes and Use Cases
- Redundant Ring Networks: Turbo Ring™ ensures sub-300 ms recovery in case of link failure, maintaining continuous communication for SCADA and control systems.
- Device Replacement: DHCP/BootP and RARP protocols automatically reassign IP addresses to replacement devices, minimizing downtime.
- Network Diagnostics: Port mirroring and ping utilities allow real-time monitoring and troubleshooting.
- Event Notification: Configurable e-mail and relay alarms alert operators to power failures, link loss, or configuration changes.
Applications
- Factory automation and process control
- Power generation and distribution networks
- Transportation and traffic control systems
- Oil, gas, and petrochemical facilities
- Water and wastewater treatment plants
- Building automation and security systems
Compatibility
- Fully interoperable with standard Ethernet devices and industrial protocols.
- Integrates with SNMP-based network management systems and OPC-compatible SCADA software.
### 5. Components & Accessories
Included Items
- ED6008-SS-SC switch unit
- User’s manual and documentation
- DIN-rail mounting kit
Optional Accessories
- Power Supplies:
- DR-4524: 45W/2A DIN-rail 24 VDC power supply (85–264 VAC input)
- DR-75-24: 75W/3.2A DIN-rail 24 VDC power supply (85–264 VAC input)
- DR-120-24: 120W/5A DIN-rail 24 VDC power supply (88–132 VAC / 176–264 VAC input)
- Software:
- EDS-SNMP OPC Server Pro (CD with software and manual) for SNMP-to-OPC integration
Connectors
- RJ45 connectors for copper Ethernet ports
- SC connectors for fiber ports
- Removable terminal block for power input
- RJ45 console port for serial management
### 6. Installation & Setup
Installation Requirements
- 24 VDC power source (redundant inputs recommended)
- DIN-rail or wall-mount surface
- Proper grounding and shielding for industrial environments
Mounting Options
- DIN-Rail Mounting: Standard 35 mm DIN-rail clip for quick installation in control cabinets.
- Wall Mounting: Optional brackets for panel or enclosure mounting.
Configuration Interfaces
- Web Browser: Intuitive GUI for configuration and monitoring.
- Telnet/Serial Console: Command-line interface for advanced setup.
- Windows Utility: Moxa’s configuration software for batch setup and parameter management.
- Batch Configurator: Enables import/export of configuration files across multiple devices.
Setup Process
1. Mount the device on DIN-rail or wall surface.
2. Connect power inputs (P1 and P2) for redundancy.
3. Connect Ethernet and fiber cables to respective ports.
4. Access the device via web browser or console for initial configuration.
5. Configure IP settings, VLANs, redundancy, and alarm parameters.
6. Verify network connectivity and redundancy status.
### 7. Performance & Capabilities
Switching Performance
- Store-and-forward architecture ensures reliable data transmission.
- 4096 MAC address entries support large-scale industrial networks.
- Full wire-speed switching for 10/100 Mbps traffic.
Redundancy and Recovery
- Turbo Ring™ recovery time <300 ms under full load.
- Line-Swap Fast Recovery <1 second for topology changes.
- Dual power inputs ensure continuous operation during power source failure.
Capacity and Efficiency
- Supports up to 8 simultaneous Ethernet connections.
- Fiber ports extend network reach up to 15 km.
- Efficient thermal design for continuous operation in high-temperature environments.
Limitations
- 100 Mbps maximum per port (no Gigabit support).
- Limited to 8 ports; expansion requires additional switches.
- Management features optimized for Ethernet-based automation (no PoE support).
### 8. Standards & Compliance
Safety Certifications
- UL60950 (E212360)
- UL508
- CSA C22.2 No. 60950
- EN60950
Hazardous Location Approvals
- UL/cUL Class 1, Division 2, Groups A, B, C, D (E238559)
- ATEX Class 1, Zone 2, EEx nC IIC (03CA24537)
EMI/EMS Compliance
- EMI: FCC Part 15, CISPR (EN55022) Class A
- EMS:
- EN61000-4-2 (ESD) Level 3
- EN61000-4-3 (RS) Level 3
- EN61000-4-4 (EFT) Level 3
- EN61000-4-5 (Surge) Level 3
- EN61000-4-6 (CS) Level 3
Environmental and Mechanical Standards
- Shock: IEC60068-2-27
- Vibration: IEC60068-2-6
- Free Fall: IEC60068-2-32
Reliability
- MTBF: 230,000 hours (MIL-HDBK-217F, GB database)
- Designed for continuous 24/7 operation in industrial environments.
### 9. Additional Information
Warranty and Support
- Warranty: 5 years standard manufacturer warranty.
- Technical Support: Available via MOXA’s global support network and online resources.
- Firmware Updates: Provided through MOXA’s website for enhanced functionality and security.
Maintenance
- Minimal maintenance required due to fanless, solid-state design.
- Periodic inspection of power and network connections recommended.
- Firmware updates can be applied remotely via web or Telnet interface.
Software Integration
- EDS-SNMP OPC Server Pro: Converts SNMP data into OPC format for integration with SCADA systems.
- Network Management: Supports SNMP-based monitoring and event logging for proactive maintenance.
Extended Temperature Models
- For extreme environments, the ED6008-SS-SC-T variant supports -40 to 75°C operation.
Ordering Information
- ED6008-SS-SC: 6 × 10/100BaseT(X) + 2 × 100BaseFX (single-mode SC), 0–60°C
- ED6008-SS-SC-T: Same configuration, extended temperature (-40–75°C)
### Summary
The MOXA ED6008-SS-SC is a robust, managed, redundant Ethernet switch engineered for industrial automation networks demanding high reliability, redundancy, and long-distance communication. With dual single-mode fiber ports, six copper ports, and advanced management capabilities, it ensures continuous operation even under adverse conditions. Its compliance with global safety and EMC standards, combined with MOXA’s Turbo Ring™ redundancy and Line-Swap Fast Recovery technologies, make it a trusted solution for mission-critical industrial Ethernet infrastructures.
This model’s combination of rugged hardware, intelligent management, and flexible configuration options positions it as a cornerstone component for modern industrial Ethernet networks, ensuring uptime, scalability, and operational resilience across diverse industrial sectors.
-
ED6008.pdf
PDF Catalog
No accessories available.