EX9053-MTCP
ATMEL CPU Modbus TCP 12*DI 4*DO(w/ EXT. PWR)
288,00 EUR
including VAT 342.72 EUR
- Ethernet Connectivity:
Built‑in 10/100 Base‑T (IEEE 802.3/802.3u) interface with RJ‑45 connector for direct Ethernet networking.
Supports both TCP/IP and UDP communication protocols.
- Modbus/TCP Protocol:
Fully compliant with the Modbus/TCP standard for open interoperability with industrial controllers, SCADA, and HMI software.
- High‑Density Digital I/O:
12 digital input channels (DI0–DI11) and 4 digital output channels (DO0–DO3) in a single compact module.
- Isolation Protection:
3750 Vrms optical isolation between I/O and logic circuits ensures reliable operation in noisy industrial environments.
- Flexible Input Modes:
Each DI channel supports both dry contact (mechanical switch) and wet contact (voltage‑driven) operation.
Configurable logic polarity (active‑high or active‑low) via Modbus or ASCII commands.
- Advanced DI Functions:
- Input latch for capturing transient pulses.
- 32‑bit counter per channel (500 Hz maximum count frequency).
- Software‑controlled counter start/stop/clear.
- Advanced DO Functions:
- Open‑collector (NPN) outputs rated up to 30 V DC, 500 mA per channel.
- Pulse output generation up to 500 Hz.
- Programmable pulse width and delay timing.
- Power Supply Flexibility:
Operates from an unregulated 10 – 30 V DC external power source.
- Industrial Design:
Rugged ABS enclosure with DIN‑rail, wall, or stack mounting options.
Wide operating temperature range (–25 °C to +75 °C).
- Software Support:
- Windows configuration utility (EX9000‑MTCP Utility).
- ActiveX control (TCPDAQ.OCX) and DLL API for custom application development.
- Built‑in web server for remote monitoring and control via standard browsers.
- Smart Functions:
- Dual watchdog system (module watchdog + host watchdog).
- Power‑on and safe output values for fail‑safe operation.
- DHCP support for automatic IP assignment.
- Built‑in password protection and security configuration.
Built‑in 10/100 Base‑T (IEEE 802.3/802.3u) interface with RJ‑45 connector for direct Ethernet networking.
Supports both TCP/IP and UDP communication protocols.
- Modbus/TCP Protocol:
Fully compliant with the Modbus/TCP standard for open interoperability with industrial controllers, SCADA, and HMI software.
- High‑Density Digital I/O:
12 digital input channels (DI0–DI11) and 4 digital output channels (DO0–DO3) in a single compact module.
- Isolation Protection:
3750 Vrms optical isolation between I/O and logic circuits ensures reliable operation in noisy industrial environments.
- Flexible Input Modes:
Each DI channel supports both dry contact (mechanical switch) and wet contact (voltage‑driven) operation.
Configurable logic polarity (active‑high or active‑low) via Modbus or ASCII commands.
- Advanced DI Functions:
- Input latch for capturing transient pulses.
- 32‑bit counter per channel (500 Hz maximum count frequency).
- Software‑controlled counter start/stop/clear.
- Advanced DO Functions:
- Open‑collector (NPN) outputs rated up to 30 V DC, 500 mA per channel.
- Pulse output generation up to 500 Hz.
- Programmable pulse width and delay timing.
- Power Supply Flexibility:
Operates from an unregulated 10 – 30 V DC external power source.
- Industrial Design:
Rugged ABS enclosure with DIN‑rail, wall, or stack mounting options.
Wide operating temperature range (–25 °C to +75 °C).
- Software Support:
- Windows configuration utility (EX9000‑MTCP Utility).
- ActiveX control (TCPDAQ.OCX) and DLL API for custom application development.
- Built‑in web server for remote monitoring and control via standard browsers.
- Smart Functions:
- Dual watchdog system (module watchdog + host watchdog).
- Power‑on and safe output values for fail‑safe operation.
- DHCP support for automatic IP assignment.
- Built‑in password protection and security configuration.
Comprehensive Product Summary – EX9053‑MTCP Ethernet I/O Module
### 1. Product Overview
Product Name: EX9053‑MTCP
Model: EX9053‑MTCP
Series: EX9000‑MTCP Ethernet I/O Series
Article Number: EX9053‑MTCP
Manufacturer: TOPSCCC / ExpertDAQ (www.topsccc.com.tw)
Manual Reference: EX9000‑MTCP User’s Manual, Ethernet I/O Version 2.0 (Printed June 1, 2016)
The EX9053‑MTCP is a compact, high‑density digital input/output (DIO) module designed for industrial data acquisition and remote control applications over Ethernet. It integrates an ATMEL CPU and a 10/100 Base‑T Ethernet interface supporting the Modbus/TCP protocol, enabling seamless integration with SCADA, PLC, and HMI systems. The module provides 12 optically isolated digital input channels and 4 open‑collector digital output channels, each with advanced functions such as input latching, pulse counting, and pulse output generation.
### 2. Key Features
- Ethernet Connectivity:
Built‑in 10/100 Base‑T (IEEE 802.3/802.3u) interface with RJ‑45 connector for direct Ethernet networking.
Supports both TCP/IP and UDP communication protocols.
- Modbus/TCP Protocol:
Fully compliant with the Modbus/TCP standard for open interoperability with industrial controllers, SCADA, and HMI software.
- High‑Density Digital I/O:
12 digital input channels (DI0–DI11) and 4 digital output channels (DO0–DO3) in a single compact module.
- Isolation Protection:
3750 Vrms optical isolation between I/O and logic circuits ensures reliable operation in noisy industrial environments.
- Flexible Input Modes:
Each DI channel supports both dry contact (mechanical switch) and wet contact (voltage‑driven) operation.
Configurable logic polarity (active‑high or active‑low) via Modbus or ASCII commands.
- Advanced DI Functions:
- Input latch for capturing transient pulses.
- 32‑bit counter per channel (500 Hz maximum count frequency).
- Software‑controlled counter start/stop/clear.
- Advanced DO Functions:
- Open‑collector (NPN) outputs rated up to 30 V DC, 500 mA per channel.
- Pulse output generation up to 500 Hz.
- Programmable pulse width and delay timing.
- Power Supply Flexibility:
Operates from an unregulated 10 – 30 V DC external power source.
- Industrial Design:
Rugged ABS enclosure with DIN‑rail, wall, or stack mounting options.
Wide operating temperature range (–25 °C to +75 °C).
- Software Support:
- Windows configuration utility (EX9000‑MTCP Utility).
- ActiveX control (TCPDAQ.OCX) and DLL API for custom application development.
- Built‑in web server for remote monitoring and control via standard browsers.
- Smart Functions:
- Dual watchdog system (module watchdog + host watchdog).
- Power‑on and safe output values for fail‑safe operation.
- DHCP support for automatic IP assignment.
- Built‑in password protection and security configuration.
### 3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| CPU | ATMEL microcontroller |
| Ethernet Interface | 10 Base‑T / 100 Base‑TX, IEEE 802.3/802.3u |
| Connector | RJ‑45 modular jack |
| Supported Protocols | Modbus/TCP over TCP/IP and UDP |
| Data Transfer Rate | Up to 100 Mbps |
| Digital Inputs | 12 channels, isolated single‑ended (common source/ground) |
| Input Type | Dry or wet contact (software‑selectable) |
| Logic Levels (Dry Contact) | Logic 0 = closed to GND; Logic 1 = open |
| Logic Levels (Wet Contact) | Logic 0 = 0 – 2 V DC max; Logic 1 = 10 – 50 V DC max |
| Input Impedance | 10 kΩ (wet contact) |
| Counter Function | 32‑bit counter per channel, 500 Hz max |
| Digital Outputs | 4 channels, open‑collector (NPN) |
| Output Voltage Range | +5 V to +30 V DC |
| Output Current | 500 mA max per channel |
| Pulse Output Frequency | Up to 500 Hz |
| Isolation Voltage | 3750 Vrms (I/O to logic) |
| Power Supply | Unregulated +10 V to +30 V DC |
| Power Consumption | 1.8 W typical |
| Indicators | Power, Link/Activity, CPU status LEDs |
| Enclosure Material | ABS plastic with captive mounting hardware |
| Wiring Terminal | Plug‑in screw terminal block, 0.5 – 2.5 mm² (AWG #12 – #22) |
| Operating Temperature | –25 °C to +75 °C |
| Storage Temperature | –25 °C to +85 °C |
| Humidity | 5 – 95 % RH, non‑condensing |
| Isolation (Ethernet) | 1500 V DC |
| Isolation (I/O) | 3750 Vrms |
| Protection | Over‑voltage and reverse‑polarity protection |
| Mounting | DIN‑rail, wall, or stack mounting |
| Dimensions | Compact modular housing (refer to EX9000 mechanical drawings) |
### 4. Functionality and Operation
Working Principle:
The EX9053‑MTCP acts as a remote Ethernet I/O node. It converts digital input and output signals into Modbus/TCP data accessible over Ethernet. Each input can detect logic transitions or count pulses, while each output can be switched or pulsed under host control.
Use Cases and Applications:
- Industrial automation and process control
- Remote machine monitoring
- Building management systems (BMS)
- Energy management and substation automation
- Distributed I/O expansion for PLCs and SCADA systems
- Event counting, alarm monitoring, and digital signal acquisition
Compatibility:
- Compatible with any Modbus/TCP master device (PLC, HMI, SCADA).
- Supported by ExpertDAQ Windows Utility, Modbus OPC servers, and third‑party SCADA software.
- Programmable via ActiveX, DLL API, or ASCII command set.
Communication Ports:
- TCP Port 502 (Modbus/TCP)
- UDP Port 1025 (ASCII commands)
- UDP Port 5168 (Event/Stream data)
- TCP Port 80 (HTTP Web Server)
### 5. Components & Accessories
Included:
- EX9053‑MTCP module
- Plug‑in terminal block connectors
- DIN‑rail mounting clip
- Quick start and safety documentation
Optional Accessories:
- 24 V DC industrial power supply
- Ethernet cables (Cat 5 or better)
- ExpertDAQ configuration utility (downloadable)
- ActiveX and DLL software libraries for integration
Connectors:
- Power: +Vs and GND screw terminals
- Digital Inputs: DI0 – DI11 and DI.COM (common)
- Digital Outputs: DO0 – DO3 and DO.GND (common)
- Ethernet: RJ‑45 10/100 Base‑T port
### 6. Installation & Setup
Requirements:
- IBM‑PC compatible host with Ethernet interface
- Windows 95/98/2000/XP/7/8/10 or later
- 10/100 Mbps Ethernet hub/switch
- Power supply +10 – 30 V DC (typ. 24 V DC)
Mounting Options:
- DIN‑rail (standard industrial mounting)
- Wall‑mount brackets
- Stackable configuration for multi‑module systems
Wiring Guidelines:
- Use shielded twisted‑pair cables for Ethernet (Cat 5 or higher).
- Keep I/O wiring short and separated from high‑voltage lines.
- Use continuous wire lengths; avoid splices.
- Ensure proper grounding to minimize noise.
Configuration Steps:
1. Connect power and Ethernet cables.
2. Assign IP address (default 10.0.0.1, Subnet 255.0.0.0).
3. Configure via Windows Utility or web interface.
4. Verify communication using Modbus/TCP or ASCII commands.
5. Integrate with SCADA/HMI software.
DHCP Support:
When enabled, the module can obtain its IP address automatically from a DHCP server. A unique Module ID allows identification even when IP is dynamically assigned.
### 7. Performance & Capabilities
- Digital Input Performance:
- Sampling rate sufficient for 500 Hz counting.
- Input latch ensures no pulse loss.
- 32‑bit counter with overflow flag.
- Digital Output Performance:
- 500 mA max sink current per channel.
- 500 Hz max pulse output frequency.
- Programmable pulse width and delay (0.5 ms resolution).
- Network Performance:
- 10/100 Mbps auto‑negotiation.
- Supports up to 8 simultaneous UDP stream/event destinations.
- Typical response time < 10 ms on LAN.
- Reliability Features:
- Dual watchdog (module + host).
- Power‑on and safe output values.
- EEPROM storage for configuration and status.
- Automatic recovery after power failure.
- Limitations:
- DI counter frequency limited to 500 Hz.
- DO load limited to 500 mA per channel.
- Requires external power for output loads.
### 8. Standards & Compliance
- Ethernet Standards: IEEE 802.3 (10 Base‑T), IEEE 802.3u (100 Base‑TX)
- Protocol Standards: Modbus/TCP v1.1b compliant
- Electrical Safety: Isolation 3750 Vrms I/O to logic
- EMC Compliance: Designed for industrial EMI/EMC environments
- Environmental: RoHS compliant, lead‑free construction
- Operating Conditions: Industrial temperature range –25 °C to +75 °C, non‑condensing humidity 5–95 %
### 9. Additional Information
Web Server Functionality:
Each EX9053‑MTCP includes an embedded HTTP server for remote monitoring.
- Access via browser using module IP (e.g., http://10.0.0.1).
- Password‑protected login.
- Real‑time display of DI/DO status and counter values.
- Manual control of digital outputs.
Software Tools:
- EX9000‑MTCP Utility: Graphical configuration and monitoring tool.
- TCPDAQ ActiveX Control: For Visual Basic, Delphi, C++, and C# applications.
- TCPDAQ DLL API: Provides > 70 functions for TCP/UDP communication, I/O access, and Modbus operations.
- ASCII Command Set: Human‑readable commands for direct testing and integration.
- Modbus Register Map:
- DI status bits: addresses 00001 – 00012
- DO status bits: addresses 00017 – 00020
- Counter registers: 40001 – 40012 (32‑bit values)
- Configuration registers for pulse width, delay, and watchdog settings.
Security & Password Protection:
Default password “00000000”; user‑configurable for restricted access.
Network settings and firmware updates require password authentication.
Watchdog Operation:
- Module Watchdog: Hardware reset ensures continuous operation under fault conditions.
- Host Watchdog: Monitors communication with host; if timeout occurs, outputs switch to safe state.
Configurable timeout (0.1 – 25.5 s) via ASCII or Modbus commands.
Power‑On & Safe Values:
- Power‑On Value: Defines initial output state after reset or power up.
- Safe Value: Defines fail‑safe output state when host watchdog timeout occurs.
Both configurable through commands (~AA4V, ~AA5V).
Maintenance & Updates:
- Firmware upgradeable via Ethernet utility.
- Configuration stored in EEPROM (non‑volatile).
- Periodic inspection recommended for terminal tightness and environmental conditions.
Warranty & Support:
- Standard manufacturer warranty (typically 2 years).
- Technical support and software updates available from TOPSCCC website.
- Documentation and utilities downloadable from www.topsccc.com.tw.
### Summary
The EX9053‑MTCP is a robust, Ethernet‑enabled digital I/O module engineered for industrial automation and remote data acquisition. With 12 isolated digital inputs, 4 open‑collector outputs, and 3750 Vrms isolation, it offers reliable signal handling in harsh environments. Its support for Modbus/TCP and UDP protocols ensures broad compatibility with existing control systems. Advanced features such as input latching, pulse counting, pulse output, dual watchdog protection, and web‑based monitoring make it a versatile solution for distributed I/O applications. The module’s wide power range, industrial temperature tolerance, and comprehensive software support enable easy integration into modern Ethernet‑based automation architectures.
### 1. Product Overview
Product Name: EX9053‑MTCP
Model: EX9053‑MTCP
Series: EX9000‑MTCP Ethernet I/O Series
Article Number: EX9053‑MTCP
Manufacturer: TOPSCCC / ExpertDAQ (www.topsccc.com.tw)
Manual Reference: EX9000‑MTCP User’s Manual, Ethernet I/O Version 2.0 (Printed June 1, 2016)
The EX9053‑MTCP is a compact, high‑density digital input/output (DIO) module designed for industrial data acquisition and remote control applications over Ethernet. It integrates an ATMEL CPU and a 10/100 Base‑T Ethernet interface supporting the Modbus/TCP protocol, enabling seamless integration with SCADA, PLC, and HMI systems. The module provides 12 optically isolated digital input channels and 4 open‑collector digital output channels, each with advanced functions such as input latching, pulse counting, and pulse output generation.
### 2. Key Features
- Ethernet Connectivity:
Built‑in 10/100 Base‑T (IEEE 802.3/802.3u) interface with RJ‑45 connector for direct Ethernet networking.
Supports both TCP/IP and UDP communication protocols.
- Modbus/TCP Protocol:
Fully compliant with the Modbus/TCP standard for open interoperability with industrial controllers, SCADA, and HMI software.
- High‑Density Digital I/O:
12 digital input channels (DI0–DI11) and 4 digital output channels (DO0–DO3) in a single compact module.
- Isolation Protection:
3750 Vrms optical isolation between I/O and logic circuits ensures reliable operation in noisy industrial environments.
- Flexible Input Modes:
Each DI channel supports both dry contact (mechanical switch) and wet contact (voltage‑driven) operation.
Configurable logic polarity (active‑high or active‑low) via Modbus or ASCII commands.
- Advanced DI Functions:
- Input latch for capturing transient pulses.
- 32‑bit counter per channel (500 Hz maximum count frequency).
- Software‑controlled counter start/stop/clear.
- Advanced DO Functions:
- Open‑collector (NPN) outputs rated up to 30 V DC, 500 mA per channel.
- Pulse output generation up to 500 Hz.
- Programmable pulse width and delay timing.
- Power Supply Flexibility:
Operates from an unregulated 10 – 30 V DC external power source.
- Industrial Design:
Rugged ABS enclosure with DIN‑rail, wall, or stack mounting options.
Wide operating temperature range (–25 °C to +75 °C).
- Software Support:
- Windows configuration utility (EX9000‑MTCP Utility).
- ActiveX control (TCPDAQ.OCX) and DLL API for custom application development.
- Built‑in web server for remote monitoring and control via standard browsers.
- Smart Functions:
- Dual watchdog system (module watchdog + host watchdog).
- Power‑on and safe output values for fail‑safe operation.
- DHCP support for automatic IP assignment.
- Built‑in password protection and security configuration.
### 3. Technical Specifications
| Parameter | Specification |
|----------------|-------------------|
| CPU | ATMEL microcontroller |
| Ethernet Interface | 10 Base‑T / 100 Base‑TX, IEEE 802.3/802.3u |
| Connector | RJ‑45 modular jack |
| Supported Protocols | Modbus/TCP over TCP/IP and UDP |
| Data Transfer Rate | Up to 100 Mbps |
| Digital Inputs | 12 channels, isolated single‑ended (common source/ground) |
| Input Type | Dry or wet contact (software‑selectable) |
| Logic Levels (Dry Contact) | Logic 0 = closed to GND; Logic 1 = open |
| Logic Levels (Wet Contact) | Logic 0 = 0 – 2 V DC max; Logic 1 = 10 – 50 V DC max |
| Input Impedance | 10 kΩ (wet contact) |
| Counter Function | 32‑bit counter per channel, 500 Hz max |
| Digital Outputs | 4 channels, open‑collector (NPN) |
| Output Voltage Range | +5 V to +30 V DC |
| Output Current | 500 mA max per channel |
| Pulse Output Frequency | Up to 500 Hz |
| Isolation Voltage | 3750 Vrms (I/O to logic) |
| Power Supply | Unregulated +10 V to +30 V DC |
| Power Consumption | 1.8 W typical |
| Indicators | Power, Link/Activity, CPU status LEDs |
| Enclosure Material | ABS plastic with captive mounting hardware |
| Wiring Terminal | Plug‑in screw terminal block, 0.5 – 2.5 mm² (AWG #12 – #22) |
| Operating Temperature | –25 °C to +75 °C |
| Storage Temperature | –25 °C to +85 °C |
| Humidity | 5 – 95 % RH, non‑condensing |
| Isolation (Ethernet) | 1500 V DC |
| Isolation (I/O) | 3750 Vrms |
| Protection | Over‑voltage and reverse‑polarity protection |
| Mounting | DIN‑rail, wall, or stack mounting |
| Dimensions | Compact modular housing (refer to EX9000 mechanical drawings) |
### 4. Functionality and Operation
Working Principle:
The EX9053‑MTCP acts as a remote Ethernet I/O node. It converts digital input and output signals into Modbus/TCP data accessible over Ethernet. Each input can detect logic transitions or count pulses, while each output can be switched or pulsed under host control.
Use Cases and Applications:
- Industrial automation and process control
- Remote machine monitoring
- Building management systems (BMS)
- Energy management and substation automation
- Distributed I/O expansion for PLCs and SCADA systems
- Event counting, alarm monitoring, and digital signal acquisition
Compatibility:
- Compatible with any Modbus/TCP master device (PLC, HMI, SCADA).
- Supported by ExpertDAQ Windows Utility, Modbus OPC servers, and third‑party SCADA software.
- Programmable via ActiveX, DLL API, or ASCII command set.
Communication Ports:
- TCP Port 502 (Modbus/TCP)
- UDP Port 1025 (ASCII commands)
- UDP Port 5168 (Event/Stream data)
- TCP Port 80 (HTTP Web Server)
### 5. Components & Accessories
Included:
- EX9053‑MTCP module
- Plug‑in terminal block connectors
- DIN‑rail mounting clip
- Quick start and safety documentation
Optional Accessories:
- 24 V DC industrial power supply
- Ethernet cables (Cat 5 or better)
- ExpertDAQ configuration utility (downloadable)
- ActiveX and DLL software libraries for integration
Connectors:
- Power: +Vs and GND screw terminals
- Digital Inputs: DI0 – DI11 and DI.COM (common)
- Digital Outputs: DO0 – DO3 and DO.GND (common)
- Ethernet: RJ‑45 10/100 Base‑T port
### 6. Installation & Setup
Requirements:
- IBM‑PC compatible host with Ethernet interface
- Windows 95/98/2000/XP/7/8/10 or later
- 10/100 Mbps Ethernet hub/switch
- Power supply +10 – 30 V DC (typ. 24 V DC)
Mounting Options:
- DIN‑rail (standard industrial mounting)
- Wall‑mount brackets
- Stackable configuration for multi‑module systems
Wiring Guidelines:
- Use shielded twisted‑pair cables for Ethernet (Cat 5 or higher).
- Keep I/O wiring short and separated from high‑voltage lines.
- Use continuous wire lengths; avoid splices.
- Ensure proper grounding to minimize noise.
Configuration Steps:
1. Connect power and Ethernet cables.
2. Assign IP address (default 10.0.0.1, Subnet 255.0.0.0).
3. Configure via Windows Utility or web interface.
4. Verify communication using Modbus/TCP or ASCII commands.
5. Integrate with SCADA/HMI software.
DHCP Support:
When enabled, the module can obtain its IP address automatically from a DHCP server. A unique Module ID allows identification even when IP is dynamically assigned.
### 7. Performance & Capabilities
- Digital Input Performance:
- Sampling rate sufficient for 500 Hz counting.
- Input latch ensures no pulse loss.
- 32‑bit counter with overflow flag.
- Digital Output Performance:
- 500 mA max sink current per channel.
- 500 Hz max pulse output frequency.
- Programmable pulse width and delay (0.5 ms resolution).
- Network Performance:
- 10/100 Mbps auto‑negotiation.
- Supports up to 8 simultaneous UDP stream/event destinations.
- Typical response time < 10 ms on LAN.
- Reliability Features:
- Dual watchdog (module + host).
- Power‑on and safe output values.
- EEPROM storage for configuration and status.
- Automatic recovery after power failure.
- Limitations:
- DI counter frequency limited to 500 Hz.
- DO load limited to 500 mA per channel.
- Requires external power for output loads.
### 8. Standards & Compliance
- Ethernet Standards: IEEE 802.3 (10 Base‑T), IEEE 802.3u (100 Base‑TX)
- Protocol Standards: Modbus/TCP v1.1b compliant
- Electrical Safety: Isolation 3750 Vrms I/O to logic
- EMC Compliance: Designed for industrial EMI/EMC environments
- Environmental: RoHS compliant, lead‑free construction
- Operating Conditions: Industrial temperature range –25 °C to +75 °C, non‑condensing humidity 5–95 %
### 9. Additional Information
Web Server Functionality:
Each EX9053‑MTCP includes an embedded HTTP server for remote monitoring.
- Access via browser using module IP (e.g., http://10.0.0.1).
- Password‑protected login.
- Real‑time display of DI/DO status and counter values.
- Manual control of digital outputs.
Software Tools:
- EX9000‑MTCP Utility: Graphical configuration and monitoring tool.
- TCPDAQ ActiveX Control: For Visual Basic, Delphi, C++, and C# applications.
- TCPDAQ DLL API: Provides > 70 functions for TCP/UDP communication, I/O access, and Modbus operations.
- ASCII Command Set: Human‑readable commands for direct testing and integration.
- Modbus Register Map:
- DI status bits: addresses 00001 – 00012
- DO status bits: addresses 00017 – 00020
- Counter registers: 40001 – 40012 (32‑bit values)
- Configuration registers for pulse width, delay, and watchdog settings.
Security & Password Protection:
Default password “00000000”; user‑configurable for restricted access.
Network settings and firmware updates require password authentication.
Watchdog Operation:
- Module Watchdog: Hardware reset ensures continuous operation under fault conditions.
- Host Watchdog: Monitors communication with host; if timeout occurs, outputs switch to safe state.
Configurable timeout (0.1 – 25.5 s) via ASCII or Modbus commands.
Power‑On & Safe Values:
- Power‑On Value: Defines initial output state after reset or power up.
- Safe Value: Defines fail‑safe output state when host watchdog timeout occurs.
Both configurable through commands (~AA4V, ~AA5V).
Maintenance & Updates:
- Firmware upgradeable via Ethernet utility.
- Configuration stored in EEPROM (non‑volatile).
- Periodic inspection recommended for terminal tightness and environmental conditions.
Warranty & Support:
- Standard manufacturer warranty (typically 2 years).
- Technical support and software updates available from TOPSCCC website.
- Documentation and utilities downloadable from www.topsccc.com.tw.
### Summary
The EX9053‑MTCP is a robust, Ethernet‑enabled digital I/O module engineered for industrial automation and remote data acquisition. With 12 isolated digital inputs, 4 open‑collector outputs, and 3750 Vrms isolation, it offers reliable signal handling in harsh environments. Its support for Modbus/TCP and UDP protocols ensures broad compatibility with existing control systems. Advanced features such as input latching, pulse counting, pulse output, dual watchdog protection, and web‑based monitoring make it a versatile solution for distributed I/O applications. The module’s wide power range, industrial temperature tolerance, and comprehensive software support enable easy integration into modern Ethernet‑based automation architectures.
No accessories available.