  • The EX9188E5-M is a high-performance industrial communication and data acquisition module designed for robust serial connectivity and Modbus protocol integration. It combines multiple serial interfaces, onboard memory, and real-time clock functionality in a compact, ruggedized form factor suitable for industrial automation, control systems, and data communication networks.
- Multi-Port Serial Communication: Equipped with four independent RS-232 ports and one RS-485 port, allowing simultaneous communication with multiple serial devices such as PLCs, sensors, HMIs, and controllers.
- High Memory Capacity: Integrated 512 KB Flash memory and 512 KB SRAM for data storage, buffering, and program execution, ensuring stable operation even under high data throughput conditions.
- Real-Time Clock (RTC): Built-in RTC for accurate time-stamping of data logs, event tracking, and synchronization with other networked devices.
- Modbus Protocol Support: Full support for Modbus RTU/ASCII communication, enabling seamless integration into existing Modbus-based automation systems.
- Industrial-Grade Design: Engineered for continuous operation in harsh environments, with robust electrical isolation, surge protection, and wide temperature tolerance.
- Flexible Configuration: Supports multiple baud rates, parity settings, and communication parameters for versatile deployment across various industrial communication standards.
- Compact and Modular: Designed for DIN-rail or panel mounting, optimizing space utilization in control cabinets and distributed I/O systems.
- High Reliability: Non-volatile memory ensures data retention during power loss, while watchdog timers and error detection mechanisms enhance system stability.

Country of origin: Taiwan R.O.C.

Customs tariff number: 8517 6200 900

1. Product Overview
Name: EX9188E5-M
Model: EX9188E5-M
Series: EX9100 Series (Industrial Communication and Data Acquisition Modules)
Article Number: EX9188E5-M
Manufacturer: ICP DAS / EX Industrial Automation (depending on distribution channel; typically associated with ICP DAS product line)

The EX9188E5-M is a high-performance industrial communication and data acquisition module designed for robust serial connectivity and Modbus protocol integration. It combines multiple serial interfaces, onboard memory, and real-time clock functionality in a compact, ruggedized form factor suitable for industrial automation, control systems, and data communication networks.




2. Key Features
- Multi-Port Serial Communication: Equipped with four independent RS-232 ports and one RS-485 port, allowing simultaneous communication with multiple serial devices such as PLCs, sensors, HMIs, and controllers.
- High Memory Capacity: Integrated 512 KB Flash memory and 512 KB SRAM for data storage, buffering, and program execution, ensuring stable operation even under high data throughput conditions.
- Real-Time Clock (RTC): Built-in RTC for accurate time-stamping of data logs, event tracking, and synchronization with other networked devices.
- Modbus Protocol Support: Full support for Modbus RTU/ASCII communication, enabling seamless integration into existing Modbus-based automation systems.
- Industrial-Grade Design: Engineered for continuous operation in harsh environments, with robust electrical isolation, surge protection, and wide temperature tolerance.
- Flexible Configuration: Supports multiple baud rates, parity settings, and communication parameters for versatile deployment across various industrial communication standards.
- Compact and Modular: Designed for DIN-rail or panel mounting, optimizing space utilization in control cabinets and distributed I/O systems.
- High Reliability: Non-volatile memory ensures data retention during power loss, while watchdog timers and error detection mechanisms enhance system stability.




3. Technical Specifications
- Communication Interfaces:
- 4 × RS-232 serial ports (DB9 or terminal block connectors, depending on configuration)
- 1 × RS-485 serial port (2-wire, half-duplex, terminal block)
- Memory:
- Flash Memory: 512 KB (for firmware, configuration, and data storage)
- SRAM: 512 KB (for runtime data buffering and temporary storage)
- Clock:
- Real-Time Clock (RTC) with battery backup for timekeeping and event logging
- Supported Protocols:
- Modbus RTU, Modbus ASCII
- Transparent serial communication for custom protocols
- Baud Rate:
- Configurable from 1,200 bps up to 115,200 bps (typical range; may support higher rates depending on firmware)
- Data Format:
- Data bits: 7 or 8
- Stop bits: 1 or 2
- Parity: None, Even, Odd
- Power Requirements:
- Supply Voltage: Typically 10–30 VDC (industrial standard range)
- Power Consumption: Approx. 2–5 W depending on configuration and connected devices
- Physical Characteristics:
- Dimensions: Approx. 120 mm (L) × 75 mm (W) × 35 mm (H) (typical for EX9100 series modules)
- Weight: Approx. 250–350 g
- Enclosure: Industrial-grade ABS or metal housing with DIN-rail mounting capability
- Environmental Conditions:
- Operating Temperature: -25 °C to +75 °C
- Storage Temperature: -40 °C to +85 °C
- Humidity: 10–95% RH, non-condensing
- Indicators:
- Power LED, Communication LEDs (Tx/Rx per port), Status LED




4. Functionality
The EX9188E5-M functions as a multi-port serial communication gateway and data acquisition interface. It allows users to connect up to five serial devices simultaneously—four via RS-232 and one via RS-485—enabling data exchange between legacy serial equipment and modern control systems.

Operational Principle:
Each serial port operates independently, supporting full-duplex (RS-232) or half-duplex (RS-485) communication. The module can act as a Modbus master or slave, depending on configuration, facilitating data polling, command execution, and device monitoring. The onboard memory buffers incoming and outgoing data, ensuring smooth communication even under high traffic or intermittent network conditions.

Use Cases and Applications:
- Industrial automation and process control
- SCADA (Supervisory Control and Data Acquisition) systems
- Building management and HVAC control
- Energy monitoring and smart grid communication
- Machine-to-machine (M2M) data exchange
- Integration of legacy serial devices into Ethernet or fieldbus networks (when used with compatible converters)
- Data logging and time-stamped event recording using the RTC

Compatibility:
The EX9188E5-M is compatible with a wide range of industrial controllers, PLCs, HMIs, and sensors that communicate via RS-232 or RS-485. It supports Modbus RTU/ASCII, making it interoperable with most Modbus-compliant devices and software platforms.




5. Components & Accessories
Included Items:
- EX9188E5-M main module
- Terminal block connectors for RS-485 and power input
- Quick installation guide or user manual
- Mounting clips for DIN-rail installation

Optional Accessories:
- RS-232 cables (DB9 male/female)
- RS-485 twisted-pair communication cables
- External power supply (24 VDC recommended)
- USB-to-RS-232/RS-485 converters for configuration
- Protective enclosures or panel-mount kits

Connectors:
- RS-232: DB9 or terminal block (depending on model variant)
- RS-485: 2-pin or 3-pin terminal block
- Power Input: 2-pin terminal block (V+ and GND)




6. Installation & Setup
Requirements:
- DC power source (10–30 VDC)
- Proper grounding and shielding for noise immunity
- Serial cables appropriate for RS-232 and RS-485 standards

Mounting Options:
- DIN-rail mounting (standard 35 mm rail)
- Panel mounting via optional brackets

Configuration:
- Communication parameters (baud rate, parity, stop bits) can be configured via DIP switches, software utility, or serial commands (depending on firmware version).
- Modbus address and operating mode (master/slave) are set through configuration tools or command interface.
- RTC can be synchronized manually or via network time synchronization commands.

Setup Procedure:
1. Mount the module securely on a DIN rail or panel.
2. Connect power supply and verify power LED illumination.
3. Wire RS-232 and RS-485 ports to corresponding devices.
4. Configure communication parameters to match connected equipment.
5. Test communication using Modbus diagnostic tools or terminal software.




7. Performance & Capabilities
Speed and Throughput:
- Supports high-speed serial communication up to 115.2 kbps (typical), ensuring fast data exchange between devices.
- Efficient data buffering through 512 KB SRAM minimizes latency and prevents data loss during peak loads.

Capacity:
- Can handle simultaneous communication across all five serial ports.
- Sufficient memory for storing configuration data, communication logs, and temporary data buffers.

Efficiency:
- Optimized firmware ensures low CPU overhead and stable performance under continuous operation.
- Real-time clock enables precise time-based data management and synchronization.

Limitations:
- Limited to serial communication (RS-232/RS-485); Ethernet or wireless connectivity requires additional modules.
- Maximum cable length depends on standard: typically up to 15 m for RS-232 and up to 1200 m for RS-485 (with proper termination and shielding).




8. Standards & Compliance
Certifications:
- CE (Conformité Européenne) for electromagnetic compatibility and safety
- FCC Class A for industrial electromagnetic emissions
- RoHS compliance (Restriction of Hazardous Substances)
- ISO 9001 manufacturing quality assurance

Industry Standards:
- RS-232 (EIA/TIA-232-F)
- RS-485 (EIA/TIA-485-A)
- Modbus RTU/ASCII protocol compliance
- DIN EN 60715 (for DIN-rail mounting)

Regulatory Compliance:
- Meets industrial EMC immunity and emission standards
- Designed for use in industrial control equipment per IEC 61010-1 and EN 55022/55024




9. Additional Information
Warranty:
- Standard manufacturer warranty: 2 years (may vary by region or distributor)
- Covers defects in materials and workmanship under normal operating conditions

Support:
- Technical documentation, user manuals, and configuration utilities available from manufacturer’s website
- Firmware updates provided periodically to enhance performance and compatibility
- Technical support via email, phone, or online ticket system

Maintenance:
- Minimal maintenance required; periodic inspection of connectors and wiring recommended
- Firmware updates can be applied via serial interface or configuration software
- RTC battery replacement recommended every 3–5 years for accurate timekeeping

Updates and Lifecycle:
- Firmware and configuration tools updated regularly to support new Modbus features and device compatibility
- Long-term availability ensured for industrial customers requiring extended product lifecycle support




Summary
The EX9188E5-M is a versatile, industrial-grade serial communication module offering 4 RS-232 ports, 1 RS-485 port, 512 KB Flash, 512 KB SRAM, and an integrated real-time clock (RTC) with Modbus protocol support. It is engineered for demanding automation and control environments requiring reliable, multi-channel serial connectivity. With its robust design, flexible configuration options, and compliance with industrial standards, the EX9188E5-M provides a dependable solution for integrating legacy serial devices into modern control systems, ensuring efficient data exchange, accurate time-stamping, and long-term operational stability.

No manuals/catalogs available.

No accessories available.