- High-Density Analog I/O: 16 voltage input channels and 2 voltage output channels integrated on one board.
- Robust Construction: Metal cover provides mechanical protection and EMI shielding for industrial reliability.
- HSL Communication Interface: Utilizes ADLINK’s High-Speed Link (HSL) technology for fast, deterministic data transfer between remote I/O modules and host controllers.
- Flexible Voltage Input Range: Supports multiple voltage input ranges (typically ±10 V, 0–10 V, or configurable per channel, depending on system setup).
- Precision Analog Conversion: High-resolution A/D and D/A converters ensure accurate signal measurement and output control.
- Compact Modular Design: Optimized for distributed I/O architectures, reducing wiring complexity and installation footprint.
- Scalable System Integration: Compatible with other ADLINK HSL modules for mixed analog/digital I/O configurations.
- Industrial Reliability: Designed for continuous operation in environments with electrical noise, vibration, and temperature variations.
- Easy Configuration: Software tools and drivers available for seamless integration with ADLINK controllers and third-party automation software.
- Versatile Application Support: Suitable for process monitoring, test benches, machine automation, and laboratory instrumentation.
- Robust Construction: Metal cover provides mechanical protection and EMI shielding for industrial reliability.
- HSL Communication Interface: Utilizes ADLINK’s High-Speed Link (HSL) technology for fast, deterministic data transfer between remote I/O modules and host controllers.
- Flexible Voltage Input Range: Supports multiple voltage input ranges (typically ±10 V, 0–10 V, or configurable per channel, depending on system setup).
- Precision Analog Conversion: High-resolution A/D and D/A converters ensure accurate signal measurement and output control.
- Compact Modular Design: Optimized for distributed I/O architectures, reducing wiring complexity and installation footprint.
- Scalable System Integration: Compatible with other ADLINK HSL modules for mixed analog/digital I/O configurations.
- Industrial Reliability: Designed for continuous operation in environments with electrical noise, vibration, and temperature variations.
- Easy Configuration: Software tools and drivers available for seamless integration with ADLINK controllers and third-party automation software.
- Versatile Application Support: Suitable for process monitoring, test benches, machine automation, and laboratory instrumentation.
1. Product Overview
Product Name: Robust HSL Board 16-Channel Voltage Input
Model: HSL-AI16AO2-M-VV
Series: HSL (High-Speed Link) Modular I/O Series
Article Number: HSL-AI16AO2-M-VV
Manufacturer: ADLINK Technology Inc.
The ADLINK HSL-AI16AO2-M-VV is a robust, industrial-grade HSL (High-Speed Link) analog I/O module designed for distributed data acquisition and control applications. It integrates 16 analog voltage input channels and 2 analog voltage output channels on a single board, providing a compact and efficient solution for analog signal interfacing in automation, process control, and machine monitoring systems. The module features a metal cover enclosure for enhanced durability and electromagnetic shielding, ensuring reliable operation in harsh industrial environments.
2. Key Features
- High-Density Analog I/O: 16 voltage input channels and 2 voltage output channels integrated on one board.
- Robust Construction: Metal cover provides mechanical protection and EMI shielding for industrial reliability.
- HSL Communication Interface: Utilizes ADLINK’s High-Speed Link (HSL) technology for fast, deterministic data transfer between remote I/O modules and host controllers.
- Flexible Voltage Input Range: Supports multiple voltage input ranges (typically ±10 V, 0–10 V, or configurable per channel, depending on system setup).
- Precision Analog Conversion: High-resolution A/D and D/A converters ensure accurate signal measurement and output control.
- Compact Modular Design: Optimized for distributed I/O architectures, reducing wiring complexity and installation footprint.
- Scalable System Integration: Compatible with other ADLINK HSL modules for mixed analog/digital I/O configurations.
- Industrial Reliability: Designed for continuous operation in environments with electrical noise, vibration, and temperature variations.
- Easy Configuration: Software tools and drivers available for seamless integration with ADLINK controllers and third-party automation software.
- Versatile Application Support: Suitable for process monitoring, test benches, machine automation, and laboratory instrumentation.
3. Technical Specifications
*(Note: Values are representative of the HSL-AI16AO2-M-VV class; refer to ADLINK documentation for exact figures.)*
- Analog Input Channels: 16 voltage input channels
- Analog Output Channels: 2 voltage output channels (daughter board integrated)
- Input Type: Single-ended or differential voltage input (configurable)
- Input Voltage Range: ±10 V, 0–10 V, or user-selectable ranges
- Input Resolution: 12-bit or 16-bit A/D conversion (depending on configuration)
- Input Sampling Rate: Up to 100 kS/s aggregate (typical for HSL analog modules)
- Output Voltage Range: 0–10 V or ±10 V (software configurable)
- Output Resolution: 12-bit or 16-bit D/A conversion
- Output Drive Capability: ±5 mA typical
- Isolation: Channel-to-system isolation up to 2500 Vrms (typical)
- Communication Interface: HSL (High-Speed Link) serial bus
- Bus Speed: Up to 10 Mbps (depending on HSL master and cable length)
- Connectors: Standard industrial terminal blocks or DB-type connectors for signal wiring
- Power Supply: 24 VDC nominal (range 18–30 VDC)
- Power Consumption: Approx. 5–8 W (depending on load and configuration)
- Enclosure Material: Metal cover (aluminum or steel alloy)
- Dimensions: Approx. 120 mm (W) × 100 mm (D) × 35 mm (H)
- Weight: Approx. 350–450 g
- Operating Temperature: 0°C to +60°C
- Storage Temperature: -20°C to +80°C
- Relative Humidity: 5% to 95% RH, non-condensing
- Mounting: DIN-rail or panel mount compatible
- LED Indicators: Power, communication status, and channel activity indicators
4. Functionality
The HSL-AI16AO2-M-VV operates as a distributed analog I/O node within an HSL-based control network. It connects to an HSL master controller (such as an ADLINK motion controller or industrial PC) via a high-speed serial link. The module continuously samples analog voltage signals from sensors, transducers, or process instruments connected to its 16 input channels. These signals are digitized and transmitted to the host controller for monitoring, logging, or closed-loop control.
Conversely, the two analog output channels can generate precise voltage signals to drive actuators, control valves, or provide reference voltages for external devices. The outputs are updated in real time based on commands from the host system.
Typical Use Cases:
- Industrial process monitoring (temperature, pressure, flow sensors with voltage outputs)
- Machine automation and motion control systems
- Test and measurement setups requiring multiple analog inputs
- Laboratory instrumentation and data acquisition systems
- Energy management and environmental monitoring applications
Compatibility:
- Fully compatible with ADLINK HSL master modules and controllers
- Supported by ADLINK’s HSL software suite and drivers for Windows and real-time operating systems
- Integrates with third-party SCADA, PLC, and data acquisition software via standard APIs
5. Components & Accessories
Included Items:
- HSL-AI16AO2-M-VV main module with metal cover
- Integrated 2-channel analog output daughter board
- Terminal block connectors or detachable screw terminals (depending on configuration)
- Quick installation guide and documentation
- Mounting hardware (DIN-rail clip or panel screws)
Optional Accessories:
- HSL communication cables (shielded twisted pair, various lengths)
- External power supply (24 VDC industrial-grade)
- Signal conditioning modules (for scaling or isolation)
- Protective covers and cable strain relief accessories
- Software development kit (SDK) and configuration utilities
Connectors:
- Power input connector (24 VDC)
- HSL communication port (RJ-45 or proprietary connector)
- Analog input/output terminal blocks for field wiring
6. Installation & Setup
Requirements:
- 24 VDC regulated power source
- HSL master controller or compatible host interface
- Proper grounding and shielding for analog signal integrity
Mounting Options:
- DIN-rail mounting for control cabinet integration
- Panel mounting using screw holes on the metal enclosure
Configuration Steps:
1. Mount the module securely in the control panel or DIN rail.
2. Connect the 24 VDC power supply and verify polarity.
3. Connect the HSL communication cable to the master controller.
4. Wire analog input and output channels according to the signal type and voltage range.
5. Configure channel parameters (input range, sampling rate, output scaling) using ADLINK’s configuration software.
6. Verify communication status via LED indicators.
7. Perform calibration or signal verification as required.
Software Setup:
- Install ADLINK HSL driver package and configuration utility.
- Detect the module automatically through the HSL network scan.
- Assign module ID and communication parameters.
- Integrate with application software or control logic.
7. Performance & Capabilities
The HSL-AI16AO2-M-VV delivers high-performance analog signal acquisition and generation with low latency and high accuracy. The HSL communication protocol ensures deterministic data transfer, making it suitable for time-critical control applications.
Performance Highlights:
- High-Speed Data Acquisition: Capable of sampling multiple channels simultaneously with minimal delay.
- High Accuracy: Low offset and gain error, ensuring precise voltage measurement and output.
- Low Noise Design: Shielded metal enclosure and optimized PCB layout minimize signal interference.
- Scalability: Multiple modules can be daisy-chained on the same HSL bus for expanded I/O capacity.
- Reliability: Designed for 24/7 operation in industrial environments with robust electrical isolation.
Limitations:
- Analog input and output ranges are limited to voltage signals (no direct current or thermocouple inputs without conditioning).
- Requires HSL-compatible master controller for operation.
- Sampling rate and resolution may vary depending on system configuration and bus load.
8. Standards & Compliance
The HSL-AI16AO2-M-VV complies with major industrial and safety standards to ensure interoperability and reliability in professional environments.
Certifications and Compliance:
- CE Marking: Conforms to European EMC and Low Voltage Directives.
- RoHS Compliance: Meets Restriction of Hazardous Substances Directive requirements.
- EMC Standards: EN 55022 / EN 55024 for electromagnetic compatibility.
- Safety Standards: EN 61010-1 for measurement, control, and laboratory equipment.
- Industrial Standards: Compatible with IEC 61131-based automation systems.
- Quality Assurance: Manufactured under ISO 9001-certified quality management system.
Environmental Compliance:
- Lead-free and environmentally friendly design.
- Designed for long lifecycle and maintainability in industrial applications.
9. Additional Information
Warranty:
- Standard 2-year limited warranty from ADLINK Technology.
- Covers defects in materials and workmanship under normal operating conditions.
Support:
- Comprehensive technical support via ADLINK’s global service network.
- Online resources including manuals, drivers, and firmware updates.
- Application engineering assistance for system integration and troubleshooting.
Maintenance:
- Periodic inspection recommended for connectors and wiring integrity.
- Calibration intervals depend on application accuracy requirements (typically 12–24 months).
- Firmware updates available through ADLINK’s support portal.
Software & Updates:
- Supported by ADLINK’s HSL configuration utility and SDK.
- Compatible with major programming environments (C/C++, LabVIEW, .NET).
- Regular firmware and driver updates ensure compatibility with new HSL controllers and operating systems.
Lifecycle & Availability:
- Long-term availability guaranteed under ADLINK’s industrial product lifecycle policy.
- Backward compatibility with previous HSL analog I/O modules.
Summary
The ADLINK HSL-AI16AO2-M-VV is a robust, high-performance analog I/O module engineered for industrial automation and data acquisition systems. With 16 voltage input channels, 2 voltage output channels, and a durable metal enclosure, it provides reliable, accurate, and scalable analog interfacing over ADLINK’s High-Speed Link (HSL) network. Its combination of precision, ruggedness, and ease of integration makes it an ideal choice for engineers and system integrators seeking dependable analog signal processing in distributed control architectures.
Product Name: Robust HSL Board 16-Channel Voltage Input
Model: HSL-AI16AO2-M-VV
Series: HSL (High-Speed Link) Modular I/O Series
Article Number: HSL-AI16AO2-M-VV
Manufacturer: ADLINK Technology Inc.
The ADLINK HSL-AI16AO2-M-VV is a robust, industrial-grade HSL (High-Speed Link) analog I/O module designed for distributed data acquisition and control applications. It integrates 16 analog voltage input channels and 2 analog voltage output channels on a single board, providing a compact and efficient solution for analog signal interfacing in automation, process control, and machine monitoring systems. The module features a metal cover enclosure for enhanced durability and electromagnetic shielding, ensuring reliable operation in harsh industrial environments.
2. Key Features
- High-Density Analog I/O: 16 voltage input channels and 2 voltage output channels integrated on one board.
- Robust Construction: Metal cover provides mechanical protection and EMI shielding for industrial reliability.
- HSL Communication Interface: Utilizes ADLINK’s High-Speed Link (HSL) technology for fast, deterministic data transfer between remote I/O modules and host controllers.
- Flexible Voltage Input Range: Supports multiple voltage input ranges (typically ±10 V, 0–10 V, or configurable per channel, depending on system setup).
- Precision Analog Conversion: High-resolution A/D and D/A converters ensure accurate signal measurement and output control.
- Compact Modular Design: Optimized for distributed I/O architectures, reducing wiring complexity and installation footprint.
- Scalable System Integration: Compatible with other ADLINK HSL modules for mixed analog/digital I/O configurations.
- Industrial Reliability: Designed for continuous operation in environments with electrical noise, vibration, and temperature variations.
- Easy Configuration: Software tools and drivers available for seamless integration with ADLINK controllers and third-party automation software.
- Versatile Application Support: Suitable for process monitoring, test benches, machine automation, and laboratory instrumentation.
3. Technical Specifications
*(Note: Values are representative of the HSL-AI16AO2-M-VV class; refer to ADLINK documentation for exact figures.)*
- Analog Input Channels: 16 voltage input channels
- Analog Output Channels: 2 voltage output channels (daughter board integrated)
- Input Type: Single-ended or differential voltage input (configurable)
- Input Voltage Range: ±10 V, 0–10 V, or user-selectable ranges
- Input Resolution: 12-bit or 16-bit A/D conversion (depending on configuration)
- Input Sampling Rate: Up to 100 kS/s aggregate (typical for HSL analog modules)
- Output Voltage Range: 0–10 V or ±10 V (software configurable)
- Output Resolution: 12-bit or 16-bit D/A conversion
- Output Drive Capability: ±5 mA typical
- Isolation: Channel-to-system isolation up to 2500 Vrms (typical)
- Communication Interface: HSL (High-Speed Link) serial bus
- Bus Speed: Up to 10 Mbps (depending on HSL master and cable length)
- Connectors: Standard industrial terminal blocks or DB-type connectors for signal wiring
- Power Supply: 24 VDC nominal (range 18–30 VDC)
- Power Consumption: Approx. 5–8 W (depending on load and configuration)
- Enclosure Material: Metal cover (aluminum or steel alloy)
- Dimensions: Approx. 120 mm (W) × 100 mm (D) × 35 mm (H)
- Weight: Approx. 350–450 g
- Operating Temperature: 0°C to +60°C
- Storage Temperature: -20°C to +80°C
- Relative Humidity: 5% to 95% RH, non-condensing
- Mounting: DIN-rail or panel mount compatible
- LED Indicators: Power, communication status, and channel activity indicators
4. Functionality
The HSL-AI16AO2-M-VV operates as a distributed analog I/O node within an HSL-based control network. It connects to an HSL master controller (such as an ADLINK motion controller or industrial PC) via a high-speed serial link. The module continuously samples analog voltage signals from sensors, transducers, or process instruments connected to its 16 input channels. These signals are digitized and transmitted to the host controller for monitoring, logging, or closed-loop control.
Conversely, the two analog output channels can generate precise voltage signals to drive actuators, control valves, or provide reference voltages for external devices. The outputs are updated in real time based on commands from the host system.
Typical Use Cases:
- Industrial process monitoring (temperature, pressure, flow sensors with voltage outputs)
- Machine automation and motion control systems
- Test and measurement setups requiring multiple analog inputs
- Laboratory instrumentation and data acquisition systems
- Energy management and environmental monitoring applications
Compatibility:
- Fully compatible with ADLINK HSL master modules and controllers
- Supported by ADLINK’s HSL software suite and drivers for Windows and real-time operating systems
- Integrates with third-party SCADA, PLC, and data acquisition software via standard APIs
5. Components & Accessories
Included Items:
- HSL-AI16AO2-M-VV main module with metal cover
- Integrated 2-channel analog output daughter board
- Terminal block connectors or detachable screw terminals (depending on configuration)
- Quick installation guide and documentation
- Mounting hardware (DIN-rail clip or panel screws)
Optional Accessories:
- HSL communication cables (shielded twisted pair, various lengths)
- External power supply (24 VDC industrial-grade)
- Signal conditioning modules (for scaling or isolation)
- Protective covers and cable strain relief accessories
- Software development kit (SDK) and configuration utilities
Connectors:
- Power input connector (24 VDC)
- HSL communication port (RJ-45 or proprietary connector)
- Analog input/output terminal blocks for field wiring
6. Installation & Setup
Requirements:
- 24 VDC regulated power source
- HSL master controller or compatible host interface
- Proper grounding and shielding for analog signal integrity
Mounting Options:
- DIN-rail mounting for control cabinet integration
- Panel mounting using screw holes on the metal enclosure
Configuration Steps:
1. Mount the module securely in the control panel or DIN rail.
2. Connect the 24 VDC power supply and verify polarity.
3. Connect the HSL communication cable to the master controller.
4. Wire analog input and output channels according to the signal type and voltage range.
5. Configure channel parameters (input range, sampling rate, output scaling) using ADLINK’s configuration software.
6. Verify communication status via LED indicators.
7. Perform calibration or signal verification as required.
Software Setup:
- Install ADLINK HSL driver package and configuration utility.
- Detect the module automatically through the HSL network scan.
- Assign module ID and communication parameters.
- Integrate with application software or control logic.
7. Performance & Capabilities
The HSL-AI16AO2-M-VV delivers high-performance analog signal acquisition and generation with low latency and high accuracy. The HSL communication protocol ensures deterministic data transfer, making it suitable for time-critical control applications.
Performance Highlights:
- High-Speed Data Acquisition: Capable of sampling multiple channels simultaneously with minimal delay.
- High Accuracy: Low offset and gain error, ensuring precise voltage measurement and output.
- Low Noise Design: Shielded metal enclosure and optimized PCB layout minimize signal interference.
- Scalability: Multiple modules can be daisy-chained on the same HSL bus for expanded I/O capacity.
- Reliability: Designed for 24/7 operation in industrial environments with robust electrical isolation.
Limitations:
- Analog input and output ranges are limited to voltage signals (no direct current or thermocouple inputs without conditioning).
- Requires HSL-compatible master controller for operation.
- Sampling rate and resolution may vary depending on system configuration and bus load.
8. Standards & Compliance
The HSL-AI16AO2-M-VV complies with major industrial and safety standards to ensure interoperability and reliability in professional environments.
Certifications and Compliance:
- CE Marking: Conforms to European EMC and Low Voltage Directives.
- RoHS Compliance: Meets Restriction of Hazardous Substances Directive requirements.
- EMC Standards: EN 55022 / EN 55024 for electromagnetic compatibility.
- Safety Standards: EN 61010-1 for measurement, control, and laboratory equipment.
- Industrial Standards: Compatible with IEC 61131-based automation systems.
- Quality Assurance: Manufactured under ISO 9001-certified quality management system.
Environmental Compliance:
- Lead-free and environmentally friendly design.
- Designed for long lifecycle and maintainability in industrial applications.
9. Additional Information
Warranty:
- Standard 2-year limited warranty from ADLINK Technology.
- Covers defects in materials and workmanship under normal operating conditions.
Support:
- Comprehensive technical support via ADLINK’s global service network.
- Online resources including manuals, drivers, and firmware updates.
- Application engineering assistance for system integration and troubleshooting.
Maintenance:
- Periodic inspection recommended for connectors and wiring integrity.
- Calibration intervals depend on application accuracy requirements (typically 12–24 months).
- Firmware updates available through ADLINK’s support portal.
Software & Updates:
- Supported by ADLINK’s HSL configuration utility and SDK.
- Compatible with major programming environments (C/C++, LabVIEW, .NET).
- Regular firmware and driver updates ensure compatibility with new HSL controllers and operating systems.
Lifecycle & Availability:
- Long-term availability guaranteed under ADLINK’s industrial product lifecycle policy.
- Backward compatibility with previous HSL analog I/O modules.
Summary
The ADLINK HSL-AI16AO2-M-VV is a robust, high-performance analog I/O module engineered for industrial automation and data acquisition systems. With 16 voltage input channels, 2 voltage output channels, and a durable metal enclosure, it provides reliable, accurate, and scalable analog interfacing over ADLINK’s High-Speed Link (HSL) network. Its combination of precision, ruggedness, and ease of integration makes it an ideal choice for engineers and system integrators seeking dependable analog signal processing in distributed control architectures.
-
HSL-AI16AO2-M-VV+-AV_Datasheet_9.pdf
PDF Catalog
No accessories available.