LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
- Industrial Managed Switch: 20-port managed Ethernet switch with 16×10/100/1000Base‑T(X) RJ‑45 ports and 4×100/1000Base‑X SFP combo ports.
- High Voltage Power Input: Dual redundant power inputs supporting 85–264 VAC or 88–373 VDC for maximum reliability.
- Rugged Design: IP‑30 metal enclosure, fanless operation, and extended operating temperature range from ‑40 °C to +70 °C.
- Smart Grid & Railway Compliance: Fully compliant with IEC 61850‑3, IEEE 1613, and EN50155 standards for power automation and rolling stock applications.
- Advanced Network Redundancy: Supports O‑Ring, Open‑Ring, O‑Chain, MRP, and MSTP (RSTP/STP compatible) with recovery time < 30 ms over 250 nodes.
- Comprehensive Management: Web browser, Telnet, console, SNMP, and ORing’s Open‑Vision utility for centralized management.
- Enhanced Security: Supports 802.1x authentication, SNMPv3 encryption, HTTPS/SSH, MAC‑based port security, and RADIUS centralized password management.
- QoS and VLAN Support: IEEE 802.1p QoS, IEEE 802.1Q VLAN tagging, GVRP, and IGMP snooping for traffic prioritization and multicast control.
- High Performance: 40 Gbps switching bandwidth, 8 K MAC address table, 4 Mbit packet buffer, and 8 priority queues.
- Reliability Features: Redundant power inputs, relay output for fault alarm, and hardware watchdog for system stability.
- High Voltage Power Input: Dual redundant power inputs supporting 85–264 VAC or 88–373 VDC for maximum reliability.
- Rugged Design: IP‑30 metal enclosure, fanless operation, and extended operating temperature range from ‑40 °C to +70 °C.
- Smart Grid & Railway Compliance: Fully compliant with IEC 61850‑3, IEEE 1613, and EN50155 standards for power automation and rolling stock applications.
- Advanced Network Redundancy: Supports O‑Ring, Open‑Ring, O‑Chain, MRP, and MSTP (RSTP/STP compatible) with recovery time < 30 ms over 250 nodes.
- Comprehensive Management: Web browser, Telnet, console, SNMP, and ORing’s Open‑Vision utility for centralized management.
- Enhanced Security: Supports 802.1x authentication, SNMPv3 encryption, HTTPS/SSH, MAC‑based port security, and RADIUS centralized password management.
- QoS and VLAN Support: IEEE 802.1p QoS, IEEE 802.1Q VLAN tagging, GVRP, and IGMP snooping for traffic prioritization and multicast control.
- High Performance: 40 Gbps switching bandwidth, 8 K MAC address table, 4 Mbit packet buffer, and 8 priority queues.
- Reliability Features: Redundant power inputs, relay output for fault alarm, and hardware watchdog for system stability.
Comprehensive Product Summary – ORing IGS-P9164GC-HV Industrial Managed Ethernet Switch
### 1. Product Overview
Product Name: IGS-P9164GC-HV
Model: IGS-P9164GC-HV
Series: IGS-P9164 Series
Article Number: IGS-P9164GC-HV
Manufacturer: ORing Industrial Networking Corp.
Manufacturer Contact:
- Website: [www.oring-networking.com](http://www.oring-networking.com)
- Tel: +886-2-2218-1066
- Fax: +886-2-2218-1014
- Email: support@oring-networking.com
The ORing IGS-P9164GC-HV is a high-performance, industrial-grade managed Ethernet switch designed for mission-critical applications in power substations, smart grids, and railway systems. It is part of ORing’s IGS-P9164 series, which includes models IGS-P9164GF, IGS-P9164FX, and IGS-P9164GC. The HV variant supports high-voltage dual power inputs (85–264 VAC / 88–373 VDC) and complies with stringent industrial standards such as IEC 61850‑3 and EN50155, ensuring reliable operation in harsh environments.
### 2. Key Features
- Industrial Managed Switch: 20-port managed Ethernet switch with 16×10/100/1000Base‑T(X) RJ‑45 ports and 4×100/1000Base‑X SFP combo ports.
- High Voltage Power Input: Dual redundant power inputs supporting 85–264 VAC or 88–373 VDC for maximum reliability.
- Rugged Design: IP‑30 metal enclosure, fanless operation, and extended operating temperature range from ‑40 °C to +70 °C.
- Smart Grid & Railway Compliance: Fully compliant with IEC 61850‑3, IEEE 1613, and EN50155 standards for power automation and rolling stock applications.
- Advanced Network Redundancy: Supports O‑Ring, Open‑Ring, O‑Chain, MRP, and MSTP (RSTP/STP compatible) with recovery time < 30 ms over 250 nodes.
- Comprehensive Management: Web browser, Telnet, console, SNMP, and ORing’s Open‑Vision utility for centralized management.
- Enhanced Security: Supports 802.1x authentication, SNMPv3 encryption, HTTPS/SSH, MAC‑based port security, and RADIUS centralized password management.
- QoS and VLAN Support: IEEE 802.1p QoS, IEEE 802.1Q VLAN tagging, GVRP, and IGMP snooping for traffic prioritization and multicast control.
- High Performance: 40 Gbps switching bandwidth, 8 K MAC address table, 4 Mbit packet buffer, and 8 priority queues.
- Reliability Features: Redundant power inputs, relay output for fault alarm, and hardware watchdog for system stability.
### 3. Technical Specifications
Physical Characteristics:
- Dimensions (W × D × H): 115 × 159 × 154 mm (4.52 × 6.26 × 6.06 in)
- Weight: Approx. 2.186 kg (HV model)
- Enclosure: IP‑30 rated metal housing
- Mounting Options: DIN‑rail or wall‑mount
Power:
- Input Voltage (HV model): Dual 85–264 VAC or 88–373 VDC
- Power Consumption (Typical): 18.5 W
- Protection: Overload current protection and reverse polarity protection
- Redundancy: Dual power inputs (PWR1 and PWR2)
Environmental:
- Operating Temperature: ‑40 °C to +70 °C
- Storage Temperature: ‑40 °C to +85 °C
- Operating Humidity: 5 %–95 % (non‑condensing)
Performance:
- Switching Bandwidth: 40 Gbps
- Switch Latency: 7 µs
- MAC Table: 8 K entries
- Packet Buffer: 4 Mbits
- Max. VLANs: 256
- IGMP Multicast Groups: 128 per VLAN
- Processing Type: Store‑and‑Forward
- Jumbo Frame Support: Up to 9.6 KB
### 4. Functionality
Operation & Management:
The IGS‑P9164GC‑HV is a fully managed switch that can be configured via:
- Web browser (default IP: 192.168.10.1)
- Telnet or console (RS‑232, RJ‑45 to DB‑9 cable, 115200 bps, 8‑N‑1)
- SNMP (v1/v2c/v3)
- ORing Open‑Vision management software
Network Redundancy:
- O‑Ring: Proprietary fast recovery (< 30 ms over 250 devices)
- Open‑Ring: Interoperable redundancy with third‑party devices
- O‑Chain: Chain topology redundancy
- MRP: Media Redundancy Protocol
- MSTP/RSTP/STP: IEEE 802.1s/w/D compatibility
Security & Access Control:
- IEEE 802.1x port‑based authentication
- SNMPv3 encrypted management
- HTTPS/SSH secure access
- MAC‑based port security
- RADIUS centralized authentication
- Device binding and DoS/DDoS auto‑prevention
Quality of Service (QoS):
- IEEE 802.1p priority queues (8 levels)
- TOS/DiffServ support
- Application‑based QoS management
- IP‑based bandwidth control
VLAN & Multicast:
- IEEE 802.1Q VLAN tagging
- GVRP (GARP VLAN Registration Protocol)
- IGMP snooping for multicast filtering
Additional Protocols:
- DHCP Server/Client
- SMTP Client for event notifications
- Modbus TCP for industrial automation integration
Use Cases:
- Power substations and smart grid networks
- Railway and rolling stock Ethernet backbones
- Industrial automation and control systems
- Mission‑critical redundant network infrastructures
### 5. Components & Accessories
Package Contents:
- 1 × IGS‑P9164GC‑HV switch unit
- 1 × DIN‑rail mounting kit
- 1 × Wall‑mount kit
- 2 × Power cables (for HV model)
- 1 × Console cable (RJ‑45 to DB‑9)
- 1 × CD (documentation and management software)
- 1 × Quick Installation Guide (QIG)
Optional Accessories:
- SFP transceivers (100/1000Base‑X, multi‑mode or single‑mode)
- Additional DIN‑rail or wall‑mount brackets
- Industrial power supplies (if external redundancy required)
Connectors:
- Ethernet Ports: 16 × RJ‑45 (10/100/1000Base‑T(X), Auto MDI/MDIX)
- Combo Ports: 4 × 100/1000Base‑X SFP slots
- Console Port: 1 × RJ‑45 (RS‑232)
- Power Inputs: 2 × 3‑pin terminal blocks (V+/L, V‑/N)
- Relay Output: 1 × 3‑pin terminal block (COM, Fail Close, Fail Open)
### 6. Installation & Setup
Mounting Options:
- DIN‑Rail Installation:
1. Attach the DIN‑rail kit to the back panel.
2. Slide the switch onto the DIN‑rail until it clicks securely.
- Wall‑Mount Installation:
1. Attach wall‑mount brackets to both sides of the rear panel (six screws).
2. Mark and drill holes on the wall according to bracket positions.
3. Insert screws and slide the unit downward to lock in place.
Power Wiring:
1. Connect positive and negative wires to V+/L and V‑/N terminals respectively.
2. Tighten wire‑clamp screws to secure connections.
3. Connect both PWR1 and PWR2 for redundancy.
Grounding:
Connect the ground screw to a proper earth ground to minimize EMI effects.
Network Connection:
- Use Cat 5/5e UTP cables for 1000Base‑T connections (max 100 m).
- Use Cat 5 UTP for 100Base‑TX and Cat 3/4/5 for 10Base‑T.
- SFP ports support 100/1000Base‑X fiber modules (SC or LC connectors).
Configuration:
- Default IP: 192.168.10.1
- Default Username/Password: admin / admin
- Access via web browser or console for initial setup.
LED Indicators:
- PWR: Green – Power on
- PWR1/PWR2: Green – Respective power module active
- R.M: Green – Ring Master mode active
- Ring: Green – Ring mode active; Blinking – Ring broken
- Fault: Amber – System fault detected
- LNK/ACT: Green/Amber – Link/activity status per port
### 7. Performance & Capabilities
Switching Performance:
- Bandwidth: 40 Gbps
- Latency: 7 µs
- MAC Table: 8 K entries
- Buffer Memory: 4 Mbits
- VLANs: Up to 256
- Multicast Groups: 128 per VLAN
- Jumbo Frames: Up to 9.6 KB
Network Redundancy:
- O‑Ring recovery < 30 ms over 250 nodes
- MSTP/RSTP/STP for loop prevention
- O‑Chain and MRP for flexible topologies
Power Efficiency:
- Typical consumption: 18.5 W (HV model)
- Dual power redundancy ensures uninterrupted operation
Reliability:
- Hardware watchdog for system recovery
- Relay output for fault alarm integration
- Fanless design for silent, maintenance‑free operation
Limitations:
- No PoE support (data only)
- SFP modules sold separately
- Requires proper grounding and ventilation for full temperature range operation
### 8. Standards & Compliance
Ethernet Standards:
- IEEE 802.3 (10Base‑T)
- IEEE 802.3u (100Base‑TX/FX)
- IEEE 802.3z (1000Base‑X)
- IEEE 802.3ab (1000Base‑T)
- IEEE 802.3ad (LACP)
- IEEE 802.3x (Flow Control)
- IEEE 802.1p (Class of Service)
- IEEE 802.1Q (VLAN Tagging)
- IEEE 802.1w (RSTP)
- IEEE 802.1s (MSTP)
- IEEE 802.1x (Authentication)
- IEEE 802.1AB (LLDP)
Industrial & Environmental Standards:
- IEC 61850‑3 / IEEE 1613: Power automation and substation communication
- EN50155: Railway applications (EN50121‑3‑2, EN55011, EN55012‑4)
- EN60950‑1: Safety standard for IT equipment
- IP‑30: Ingress protection rating
EMI/EMS Compliance:
- EMI: FCC Part 15 Class A, CISPR (EN55022) Class A
- EMS:
- EN61000‑4‑2 (ESD)
- EN61000‑4‑3 (RS)
- EN61000‑4‑4 (EFT)
- EN61000‑4‑5 (Surge)
- EN61000‑4‑6 (CS)
- EN61000‑4‑8 (Magnetic Field)
- EN61000‑4‑11 (Dip/Interruption)
Mechanical & Environmental Tests:
- Vibration: IEC 60068‑2‑6
- Shock: IEC 60068‑2‑27
- Free Fall: IEC 60068‑2‑32
Certifications:
- CE, FCC, EN50155, IEC 61850‑3, IEEE 1613
### 9. Additional Information
Warranty: 5 years limited warranty
Maintenance:
- Periodic inspection of power and grounding connections recommended.
- Firmware updates available via ORing’s website.
- Configuration backup and restore supported through web interface.
Support & Documentation:
- Quick Installation Guide (QIG) included.
- Full user manual and Open‑Vision management software available online.
- Technical support via email or phone.
Firmware & Updates:
- Supports remote firmware upgrade via web or TFTP.
- Configuration export/import for easy deployment across multiple units.
Safety Considerations:
- Ensure adequate ventilation and ambient temperature within specified limits.
- Avoid mechanical stress or uneven loading during installation.
- Maintain proper grounding to reduce EMI and ensure safety.
### Summary
The ORing IGS‑P9164GC‑HV is a robust, high‑voltage industrial managed Ethernet switch engineered for demanding environments such as power substations, smart grids, and railway systems. With 20 Gigabit ports (16 RJ‑45 + 4 SFP combo), dual redundant high‑voltage power inputs, and compliance with IEC 61850‑3 and EN50155, it delivers exceptional reliability and performance. Its advanced redundancy protocols, comprehensive management options, and extensive security features make it ideal for mission‑critical industrial networks requiring continuous uptime and secure communication.
The switch’s rugged IP‑30 enclosure, wide temperature tolerance, and compliance with international standards ensure long‑term durability and interoperability in harsh industrial conditions. Backed by a 5‑year warranty and ORing’s global support, the IGS‑P9164GC‑HV represents a dependable solution for industrial Ethernet infrastructure where reliability, performance, and compliance are paramount.
### 1. Product Overview
Product Name: IGS-P9164GC-HV
Model: IGS-P9164GC-HV
Series: IGS-P9164 Series
Article Number: IGS-P9164GC-HV
Manufacturer: ORing Industrial Networking Corp.
Manufacturer Contact:
- Website: [www.oring-networking.com](http://www.oring-networking.com)
- Tel: +886-2-2218-1066
- Fax: +886-2-2218-1014
- Email: support@oring-networking.com
The ORing IGS-P9164GC-HV is a high-performance, industrial-grade managed Ethernet switch designed for mission-critical applications in power substations, smart grids, and railway systems. It is part of ORing’s IGS-P9164 series, which includes models IGS-P9164GF, IGS-P9164FX, and IGS-P9164GC. The HV variant supports high-voltage dual power inputs (85–264 VAC / 88–373 VDC) and complies with stringent industrial standards such as IEC 61850‑3 and EN50155, ensuring reliable operation in harsh environments.
### 2. Key Features
- Industrial Managed Switch: 20-port managed Ethernet switch with 16×10/100/1000Base‑T(X) RJ‑45 ports and 4×100/1000Base‑X SFP combo ports.
- High Voltage Power Input: Dual redundant power inputs supporting 85–264 VAC or 88–373 VDC for maximum reliability.
- Rugged Design: IP‑30 metal enclosure, fanless operation, and extended operating temperature range from ‑40 °C to +70 °C.
- Smart Grid & Railway Compliance: Fully compliant with IEC 61850‑3, IEEE 1613, and EN50155 standards for power automation and rolling stock applications.
- Advanced Network Redundancy: Supports O‑Ring, Open‑Ring, O‑Chain, MRP, and MSTP (RSTP/STP compatible) with recovery time < 30 ms over 250 nodes.
- Comprehensive Management: Web browser, Telnet, console, SNMP, and ORing’s Open‑Vision utility for centralized management.
- Enhanced Security: Supports 802.1x authentication, SNMPv3 encryption, HTTPS/SSH, MAC‑based port security, and RADIUS centralized password management.
- QoS and VLAN Support: IEEE 802.1p QoS, IEEE 802.1Q VLAN tagging, GVRP, and IGMP snooping for traffic prioritization and multicast control.
- High Performance: 40 Gbps switching bandwidth, 8 K MAC address table, 4 Mbit packet buffer, and 8 priority queues.
- Reliability Features: Redundant power inputs, relay output for fault alarm, and hardware watchdog for system stability.
### 3. Technical Specifications
Physical Characteristics:
- Dimensions (W × D × H): 115 × 159 × 154 mm (4.52 × 6.26 × 6.06 in)
- Weight: Approx. 2.186 kg (HV model)
- Enclosure: IP‑30 rated metal housing
- Mounting Options: DIN‑rail or wall‑mount
Power:
- Input Voltage (HV model): Dual 85–264 VAC or 88–373 VDC
- Power Consumption (Typical): 18.5 W
- Protection: Overload current protection and reverse polarity protection
- Redundancy: Dual power inputs (PWR1 and PWR2)
Environmental:
- Operating Temperature: ‑40 °C to +70 °C
- Storage Temperature: ‑40 °C to +85 °C
- Operating Humidity: 5 %–95 % (non‑condensing)
Performance:
- Switching Bandwidth: 40 Gbps
- Switch Latency: 7 µs
- MAC Table: 8 K entries
- Packet Buffer: 4 Mbits
- Max. VLANs: 256
- IGMP Multicast Groups: 128 per VLAN
- Processing Type: Store‑and‑Forward
- Jumbo Frame Support: Up to 9.6 KB
### 4. Functionality
Operation & Management:
The IGS‑P9164GC‑HV is a fully managed switch that can be configured via:
- Web browser (default IP: 192.168.10.1)
- Telnet or console (RS‑232, RJ‑45 to DB‑9 cable, 115200 bps, 8‑N‑1)
- SNMP (v1/v2c/v3)
- ORing Open‑Vision management software
Network Redundancy:
- O‑Ring: Proprietary fast recovery (< 30 ms over 250 devices)
- Open‑Ring: Interoperable redundancy with third‑party devices
- O‑Chain: Chain topology redundancy
- MRP: Media Redundancy Protocol
- MSTP/RSTP/STP: IEEE 802.1s/w/D compatibility
Security & Access Control:
- IEEE 802.1x port‑based authentication
- SNMPv3 encrypted management
- HTTPS/SSH secure access
- MAC‑based port security
- RADIUS centralized authentication
- Device binding and DoS/DDoS auto‑prevention
Quality of Service (QoS):
- IEEE 802.1p priority queues (8 levels)
- TOS/DiffServ support
- Application‑based QoS management
- IP‑based bandwidth control
VLAN & Multicast:
- IEEE 802.1Q VLAN tagging
- GVRP (GARP VLAN Registration Protocol)
- IGMP snooping for multicast filtering
Additional Protocols:
- DHCP Server/Client
- SMTP Client for event notifications
- Modbus TCP for industrial automation integration
Use Cases:
- Power substations and smart grid networks
- Railway and rolling stock Ethernet backbones
- Industrial automation and control systems
- Mission‑critical redundant network infrastructures
### 5. Components & Accessories
Package Contents:
- 1 × IGS‑P9164GC‑HV switch unit
- 1 × DIN‑rail mounting kit
- 1 × Wall‑mount kit
- 2 × Power cables (for HV model)
- 1 × Console cable (RJ‑45 to DB‑9)
- 1 × CD (documentation and management software)
- 1 × Quick Installation Guide (QIG)
Optional Accessories:
- SFP transceivers (100/1000Base‑X, multi‑mode or single‑mode)
- Additional DIN‑rail or wall‑mount brackets
- Industrial power supplies (if external redundancy required)
Connectors:
- Ethernet Ports: 16 × RJ‑45 (10/100/1000Base‑T(X), Auto MDI/MDIX)
- Combo Ports: 4 × 100/1000Base‑X SFP slots
- Console Port: 1 × RJ‑45 (RS‑232)
- Power Inputs: 2 × 3‑pin terminal blocks (V+/L, V‑/N)
- Relay Output: 1 × 3‑pin terminal block (COM, Fail Close, Fail Open)
### 6. Installation & Setup
Mounting Options:
- DIN‑Rail Installation:
1. Attach the DIN‑rail kit to the back panel.
2. Slide the switch onto the DIN‑rail until it clicks securely.
- Wall‑Mount Installation:
1. Attach wall‑mount brackets to both sides of the rear panel (six screws).
2. Mark and drill holes on the wall according to bracket positions.
3. Insert screws and slide the unit downward to lock in place.
Power Wiring:
1. Connect positive and negative wires to V+/L and V‑/N terminals respectively.
2. Tighten wire‑clamp screws to secure connections.
3. Connect both PWR1 and PWR2 for redundancy.
Grounding:
Connect the ground screw to a proper earth ground to minimize EMI effects.
Network Connection:
- Use Cat 5/5e UTP cables for 1000Base‑T connections (max 100 m).
- Use Cat 5 UTP for 100Base‑TX and Cat 3/4/5 for 10Base‑T.
- SFP ports support 100/1000Base‑X fiber modules (SC or LC connectors).
Configuration:
- Default IP: 192.168.10.1
- Default Username/Password: admin / admin
- Access via web browser or console for initial setup.
LED Indicators:
- PWR: Green – Power on
- PWR1/PWR2: Green – Respective power module active
- R.M: Green – Ring Master mode active
- Ring: Green – Ring mode active; Blinking – Ring broken
- Fault: Amber – System fault detected
- LNK/ACT: Green/Amber – Link/activity status per port
### 7. Performance & Capabilities
Switching Performance:
- Bandwidth: 40 Gbps
- Latency: 7 µs
- MAC Table: 8 K entries
- Buffer Memory: 4 Mbits
- VLANs: Up to 256
- Multicast Groups: 128 per VLAN
- Jumbo Frames: Up to 9.6 KB
Network Redundancy:
- O‑Ring recovery < 30 ms over 250 nodes
- MSTP/RSTP/STP for loop prevention
- O‑Chain and MRP for flexible topologies
Power Efficiency:
- Typical consumption: 18.5 W (HV model)
- Dual power redundancy ensures uninterrupted operation
Reliability:
- Hardware watchdog for system recovery
- Relay output for fault alarm integration
- Fanless design for silent, maintenance‑free operation
Limitations:
- No PoE support (data only)
- SFP modules sold separately
- Requires proper grounding and ventilation for full temperature range operation
### 8. Standards & Compliance
Ethernet Standards:
- IEEE 802.3 (10Base‑T)
- IEEE 802.3u (100Base‑TX/FX)
- IEEE 802.3z (1000Base‑X)
- IEEE 802.3ab (1000Base‑T)
- IEEE 802.3ad (LACP)
- IEEE 802.3x (Flow Control)
- IEEE 802.1p (Class of Service)
- IEEE 802.1Q (VLAN Tagging)
- IEEE 802.1w (RSTP)
- IEEE 802.1s (MSTP)
- IEEE 802.1x (Authentication)
- IEEE 802.1AB (LLDP)
Industrial & Environmental Standards:
- IEC 61850‑3 / IEEE 1613: Power automation and substation communication
- EN50155: Railway applications (EN50121‑3‑2, EN55011, EN55012‑4)
- EN60950‑1: Safety standard for IT equipment
- IP‑30: Ingress protection rating
EMI/EMS Compliance:
- EMI: FCC Part 15 Class A, CISPR (EN55022) Class A
- EMS:
- EN61000‑4‑2 (ESD)
- EN61000‑4‑3 (RS)
- EN61000‑4‑4 (EFT)
- EN61000‑4‑5 (Surge)
- EN61000‑4‑6 (CS)
- EN61000‑4‑8 (Magnetic Field)
- EN61000‑4‑11 (Dip/Interruption)
Mechanical & Environmental Tests:
- Vibration: IEC 60068‑2‑6
- Shock: IEC 60068‑2‑27
- Free Fall: IEC 60068‑2‑32
Certifications:
- CE, FCC, EN50155, IEC 61850‑3, IEEE 1613
### 9. Additional Information
Warranty: 5 years limited warranty
Maintenance:
- Periodic inspection of power and grounding connections recommended.
- Firmware updates available via ORing’s website.
- Configuration backup and restore supported through web interface.
Support & Documentation:
- Quick Installation Guide (QIG) included.
- Full user manual and Open‑Vision management software available online.
- Technical support via email or phone.
Firmware & Updates:
- Supports remote firmware upgrade via web or TFTP.
- Configuration export/import for easy deployment across multiple units.
Safety Considerations:
- Ensure adequate ventilation and ambient temperature within specified limits.
- Avoid mechanical stress or uneven loading during installation.
- Maintain proper grounding to reduce EMI and ensure safety.
### Summary
The ORing IGS‑P9164GC‑HV is a robust, high‑voltage industrial managed Ethernet switch engineered for demanding environments such as power substations, smart grids, and railway systems. With 20 Gigabit ports (16 RJ‑45 + 4 SFP combo), dual redundant high‑voltage power inputs, and compliance with IEC 61850‑3 and EN50155, it delivers exceptional reliability and performance. Its advanced redundancy protocols, comprehensive management options, and extensive security features make it ideal for mission‑critical industrial networks requiring continuous uptime and secure communication.
The switch’s rugged IP‑30 enclosure, wide temperature tolerance, and compliance with international standards ensure long‑term durability and interoperability in harsh industrial conditions. Backed by a 5‑year warranty and ORing’s global support, the IGS‑P9164GC‑HV represents a dependable solution for industrial Ethernet infrastructure where reliability, performance, and compliance are paramount.
-
DataSheet_IGS-P9164GF(X)_GC_Series_V1.0.pdf
PDF Catalog
No accessories available.