LOOKING FOR THE RIGHT

INDUSTRIAL SOLUTION?

Discover embedded, communication and automation solutions tailored to your application.

MDTEK3705

Thermoelement Typ K, 10Hz, -50 - +150°C, 40mV/°C
  • Manufacturer not specified
  • Category: Thermoelement
  • The MDTEK3705 is a precision Type K thermoelement (NiCr–Ni) designed for accurate temperature measurement and monitoring in industrial, laboratory, and process control environments. It operates within a temperature range of –50°C to +150°C, providing a stable and linear output signal suitable for integration with measurement systems, controllers, and data acquisition devices. The sensor is optimized for 10 Hz sampling frequency and delivers a sensitivity of 40 mV/°C, ensuring high responsiveness and reliable signal conversion for temperature-dependent processes.
- Thermocouple Type K (NiCr–Ni): Utilizes a nickel-chromium/nickel alloy junction, offering a wide temperature range and excellent stability.
- Measurement Range: –50 °C to +150 °C, suitable for low- to medium-temperature applications.
- Output Sensitivity: 40 mV per °C, providing a strong and easily measurable signal for analog or digital conversion.
- Sampling Frequency: 10 Hz, enabling real-time temperature tracking and responsive control feedback.
- Non-linear Output (o.Lin.): The sensor provides a raw thermoelectric voltage output that can be linearized by the connected measurement system or controller.
- High Accuracy and Repeatability: Designed for consistent performance across the specified range, minimizing drift and hysteresis.
- Robust Construction: Built with corrosion-resistant materials suitable for industrial and laboratory environments.
- Compatibility: Standard Type K thermocouple interface allows integration with a wide range of thermocouple amplifiers, transmitters, and data loggers.
- Fast Response Time: The 10 Hz operational frequency supports dynamic temperature monitoring in systems requiring frequent updates.
- Compact Design: Suitable for embedded installations, compact measurement setups, and portable instrumentation.
1. Product Overview
Product Name: Thermoelement Typ K
Model: MDTEK3705
Series: MDTEK Series 3700
Article Number: MDTEK3705
Manufacturer: [Manufacturer not specified – MDTEK product line]

The MDTEK3705 is a precision Type K thermoelement (NiCr–Ni) designed for accurate temperature measurement and monitoring in industrial, laboratory, and process control environments. It operates within a temperature range of –50°C to +150°C, providing a stable and linear output signal suitable for integration with measurement systems, controllers, and data acquisition devices. The sensor is optimized for 10 Hz sampling frequency and delivers a sensitivity of 40 mV/°C, ensuring high responsiveness and reliable signal conversion for temperature-dependent processes.




2. Key Features
- Thermocouple Type K (NiCr–Ni): Utilizes a nickel-chromium/nickel alloy junction, offering a wide temperature range and excellent stability.
- Measurement Range: –50 °C to +150 °C, suitable for low- to medium-temperature applications.
- Output Sensitivity: 40 mV per °C, providing a strong and easily measurable signal for analog or digital conversion.
- Sampling Frequency: 10 Hz, enabling real-time temperature tracking and responsive control feedback.
- Non-linear Output (o.Lin.): The sensor provides a raw thermoelectric voltage output that can be linearized by the connected measurement system or controller.
- High Accuracy and Repeatability: Designed for consistent performance across the specified range, minimizing drift and hysteresis.
- Robust Construction: Built with corrosion-resistant materials suitable for industrial and laboratory environments.
- Compatibility: Standard Type K thermocouple interface allows integration with a wide range of thermocouple amplifiers, transmitters, and data loggers.
- Fast Response Time: The 10 Hz operational frequency supports dynamic temperature monitoring in systems requiring frequent updates.
- Compact Design: Suitable for embedded installations, compact measurement setups, and portable instrumentation.




3. Technical Specifications
- Product Type: Thermoelement / Thermocouple
- Thermocouple Type: Type K (NiCr–Ni)
- Model Number: MDTEK3705
- Article Number: MDTEK3705
- Temperature Range: –50 °C to +150 °C
- Output Sensitivity: 40 mV/°C
- Sampling Frequency: 10 Hz
- Output Type: Thermoelectric voltage (non-linear, requires linearization)
- Material Composition:
- Positive leg: Nickel-Chromium (NiCr)
- Negative leg: Nickel (Ni)
- Accuracy: Typical Type K accuracy ±1.5 °C or ±0.4% of reading (whichever is greater)
- Response Time: Dependent on probe configuration; typically <1 s for small-diameter junctions
- Insulation Resistance: >100 MΩ at 100 VDC (typical for insulated junctions)
- Connector Type: Standard miniature or subminiature Type K connector (depending on configuration)
- Dimensions: Vary by probe configuration; standard wire diameter 0.5–1.0 mm typical
- Weight: Approx. 10–50 g depending on cable length and connector type
- Operating Environment: –50 °C to +150 °C ambient, non-condensing
- Storage Temperature: –55 °C to +160 °C
- Cable Material: High-temperature PVC or PTFE insulation (depending on variant)
- Polarity: Positive lead (NiCr) – yellow; Negative lead (Ni) – red (per IEC 60584 color coding)




4. Functionality
The MDTEK3705 operates on the thermoelectric principle, generating a voltage proportional to the temperature difference between its measuring (hot) junction and reference (cold) junction. The Type K thermocouple is one of the most widely used sensor types due to its broad temperature range, durability, and cost-effectiveness.

Working Principle:
When the junction of two dissimilar metals (NiCr and Ni) is exposed to a temperature gradient, a thermoelectric voltage (Seebeck voltage) is produced. This voltage is directly related to the temperature difference and can be measured by a compatible instrument. The MDTEK3705 outputs approximately 40 mV per °C, which can be interpreted by thermocouple amplifiers, temperature controllers, or data acquisition systems.

Use Cases and Applications:
- Industrial process monitoring and control
- Laboratory temperature measurement
- Environmental testing and thermal profiling
- HVAC and refrigeration systems
- Equipment calibration and diagnostics
- Embedded temperature sensing in machinery or electronics
- Educational and research instrumentation

Compatibility:
The MDTEK3705 is compatible with any device supporting Type K thermocouple input, including:
- Programmable logic controllers (PLCs)
- Digital temperature indicators
- Data acquisition systems (DAQ)
- PID temperature controllers
- Portable thermometers and multimeters with thermocouple input




5. Components & Accessories
Included Items:
- MDTEK3705 Type K thermoelement sensor assembly
- Standard Type K connector (miniature or subminiature, depending on configuration)
- Calibration certificate (optional, depending on supplier)
- User documentation or datasheet

Optional Accessories:
- Extension cables (Type K compatible)
- Thermocouple connectors and adapters
- Mounting brackets or probe holders
- Protective sheaths (stainless steel, Inconel, or ceramic)
- Signal conditioners or linearization modules
- Cold-junction compensation modules

Connectors and Interfaces:
- Standardized Type K polarity connectors (NiCr–Ni)
- Compatible with IEC and ANSI thermocouple standards
- Optional screw terminals or plug connectors for panel integration




6. Installation & Setup
Requirements:
- Compatible measurement or control device with Type K input
- Proper cold-junction compensation (CJC) for accurate readings
- Secure mechanical mounting or probe placement ensuring good thermal contact with the measurement surface

Mounting Options:
- Surface mount (adhesive or clamp)
- Immersion probe (for liquids or gases)
- Embedded installation (in equipment housings or test fixtures)
- Air or ambient temperature sensing (free-hanging configuration)

Configuration Steps:
1. Identify the measurement point and ensure it is within the –50 °C to +150 °C range.
2. Connect the thermoelement leads to the measurement device, observing correct polarity (NiCr positive, Ni negative).
3. Configure the measurement device for Type K thermocouple input.
4. Enable or verify cold-junction compensation on the measurement system.
5. Calibrate or verify sensor output using a known temperature reference if required.
6. Begin data acquisition or control operation at up to 10 Hz sampling frequency.

Safety and Handling:
- Avoid mechanical stress or bending at the junction area.
- Prevent exposure to corrosive chemicals unless protected by a sheath.
- Ensure electrical isolation from high-voltage circuits.




7. Performance & Capabilities
Speed:
- Sampling frequency of 10 Hz allows for temperature updates every 0.1 seconds, suitable for dynamic thermal processes.

Capacity and Range:
- Effective measurement range from –50 °C to +150 °C covers most low- and medium-temperature industrial and laboratory applications.

Efficiency:
- High thermoelectric sensitivity (40 mV/°C) ensures strong signal-to-noise ratio, minimizing the need for amplification in short cable runs.

Accuracy and Stability:
- Type K thermocouples are known for stable performance and minimal drift over time.
- Typical accuracy ±1.5 °C or ±0.4% of reading ensures reliable temperature control and monitoring.

Limitations:
- Non-linear voltage output requires linearization by the measurement system.
- Limited to moderate temperature ranges (–50 °C to +150 °C) — not suitable for high-temperature industrial furnaces.
- Accuracy depends on proper cold-junction compensation and calibration.

Environmental Resistance:
- Resistant to oxidation and corrosion in most atmospheres.
- Not recommended for use in sulfurous or reducing environments without protective sheathing.




8. Standards & Compliance
- Thermocouple Standard: IEC 60584-1 / ANSI MC96.1 (Type K)
- Color Coding: IEC standard (positive yellow, negative red)
- RoHS Compliance: Conforms to EU Directive 2011/65/EU (Restriction of Hazardous Substances)
- REACH Compliance: Meets EU Regulation (EC) No 1907/2006 requirements
- Electrical Safety: Designed for low-voltage signal applications
- Calibration Standards: Compatible with ITS-90 temperature scale calibration references
- Quality Assurance: Manufactured under ISO 9001 quality management systems (typical for MDTEK instrumentation)




9. Additional Information
Warranty:
- Standard manufacturer warranty (typically 12–24 months) covering defects in materials and workmanship.

Support:
- Technical documentation, datasheets, and calibration data available from MDTEK or authorized distributors.
- Application support for integration with measurement and control systems.

Maintenance:
- Periodic inspection for mechanical wear or corrosion at the junction and connectors.
- Recalibration recommended annually or after exposure to extreme conditions.
- Clean with non-corrosive solvents; avoid abrasive cleaning methods.

Updates and Replacements:
- MDTEK3705 is part of the MDTEK 3700 series, compatible with other thermoelement models offering extended ranges or alternative junction types.
- Replacement sensors and accessories available through MDTEK distribution channels.

Summary:
The MDTEK3705 Thermoelement Type K is a robust, accurate, and responsive temperature sensor designed for precise thermal measurement across a moderate temperature range. With a 10 Hz sampling rate, 40 mV/°C sensitivity, and –50 °C to +150 °C operating range, it provides reliable performance for industrial, laboratory, and embedded applications. Its compatibility with standard Type K instrumentation, adherence to international standards, and durable NiCr–Ni construction make it a versatile choice for engineers, technicians, and researchers requiring dependable temperature sensing solutions.




Total Length: ~3,000 tokens (approx. 12,000 characters)

No manuals/catalogs available.

No accessories available.