LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
- Precision Voltage Amplification: Converts low-level input signals (±750 mV) into a standardized ±5 V output range, ensuring compatibility with measurement and control systems.
- Wide Dynamic Range: Supports bipolar input and output signals, allowing accurate amplification of both positive and negative voltages.
- Low-Frequency Operation: Optimized for DC to 4 Hz, ideal for slow-changing signals such as strain gauges, thermocouples, or other transducers with low-frequency outputs.
- High Linearity and Stability: Ensures minimal distortion and drift over time and temperature, maintaining measurement accuracy.
- Compact Modular Design: Designed as a module for integration into instrumentation racks, control cabinets, or custom measurement setups.
- Noise-Optimized Circuitry: Internal design minimizes noise and interference, preserving signal integrity even at low frequencies.
- Standardized Output: ±5 V output range compatible with most analog-to-digital converters (ADCs), data acquisition systems, and control interfaces.
- Robust Construction: Built for industrial and laboratory environments, with durable materials and reliable electronic components.
- Ease of Integration: Simple electrical connections and standardized signal levels facilitate integration into existing systems.
- Wide Dynamic Range: Supports bipolar input and output signals, allowing accurate amplification of both positive and negative voltages.
- Low-Frequency Operation: Optimized for DC to 4 Hz, ideal for slow-changing signals such as strain gauges, thermocouples, or other transducers with low-frequency outputs.
- High Linearity and Stability: Ensures minimal distortion and drift over time and temperature, maintaining measurement accuracy.
- Compact Modular Design: Designed as a module for integration into instrumentation racks, control cabinets, or custom measurement setups.
- Noise-Optimized Circuitry: Internal design minimizes noise and interference, preserving signal integrity even at low frequencies.
- Standardized Output: ±5 V output range compatible with most analog-to-digital converters (ADCs), data acquisition systems, and control interfaces.
- Robust Construction: Built for industrial and laboratory environments, with durable materials and reliable electronic components.
- Ease of Integration: Simple electrical connections and standardized signal levels facilitate integration into existing systems.
1. Product Overview
Product Name: Spannungsverstärker MDV3012
Model: MDV3012
Series: MDV Series Precision Voltage Amplifiers
Article Number: MDV3012
Manufacturer: [Manufacturer not specified – typically part of the MDV industrial instrumentation line]
The MDV3012 is a precision voltage amplifier module designed for accurate signal conditioning and amplification of low-level DC and low-frequency voltage signals. It is engineered for applications requiring stable, linear, and low-noise amplification within the range of ±750 mV input and a corresponding output of ±5 V. The device operates effectively in the DC to 4 Hz frequency range, making it suitable for slow or quasi-static signal processing, sensor signal conditioning, and measurement systems where precision and stability are critical.
2. Key Features
- Precision Voltage Amplification: Converts low-level input signals (±750 mV) into a standardized ±5 V output range, ensuring compatibility with measurement and control systems.
- Wide Dynamic Range: Supports bipolar input and output signals, allowing accurate amplification of both positive and negative voltages.
- Low-Frequency Operation: Optimized for DC to 4 Hz, ideal for slow-changing signals such as strain gauges, thermocouples, or other transducers with low-frequency outputs.
- High Linearity and Stability: Ensures minimal distortion and drift over time and temperature, maintaining measurement accuracy.
- Compact Modular Design: Designed as a module for integration into instrumentation racks, control cabinets, or custom measurement setups.
- Noise-Optimized Circuitry: Internal design minimizes noise and interference, preserving signal integrity even at low frequencies.
- Standardized Output: ±5 V output range compatible with most analog-to-digital converters (ADCs), data acquisition systems, and control interfaces.
- Robust Construction: Built for industrial and laboratory environments, with durable materials and reliable electronic components.
- Ease of Integration: Simple electrical connections and standardized signal levels facilitate integration into existing systems.
3. Technical Specifications
- Model: MDV3012
- Input Range: ±750 mV (DC to 4 Hz)
- Output Range: ±5 V
- Frequency Response: DC to 4 Hz (flat response within specified range)
- Amplification Factor (Gain): Approximately 6.67 (derived from ±5 V output / ±0.75 V input)
- Input Type: Differential or single-ended (depending on configuration)
- Output Type: Voltage output, low-impedance drive suitable for standard analog inputs
- Input Impedance: High impedance (typically >1 MΩ) to minimize loading effects on signal sources
- Output Impedance: Low (typically <100 Ω) for stable signal transmission
- Power Supply: Typically ±12 V to ±15 V DC (exact value depends on system configuration)
- Operating Temperature Range: 0 °C to +50 °C (typical for instrumentation modules)
- Storage Temperature Range: -20 °C to +70 °C
- Dimensions: Approx. 100 mm × 25 mm × 75 mm (typical module size; may vary by manufacturer)
- Weight: Approx. 150–250 g (depending on housing and connectors)
- Material: Industrial-grade PCB with protective coating; aluminum or plastic enclosure
- Mounting Type: DIN rail or panel mount (depending on version)
- Signal Bandwidth: DC to 4 Hz (low-pass characteristic)
- Noise Level: <1 mV RMS (typical, depending on configuration)
- Temperature Coefficient: <50 ppm/°C (typical for precision amplifiers)
4. Functionality
The MDV3012 functions as a precision voltage amplifier that scales low-level analog signals to a standardized output range. The device accepts an input signal of up to ±750 mV and amplifies it linearly to produce an output of ±5 V. This makes it ideal for interfacing sensors or transducers that generate small voltage signals with measurement systems requiring higher-level analog inputs.
Operating Principle:
The amplifier uses a precision operational amplifier circuit with carefully selected resistors and filtering components to ensure linear amplification and low noise. The internal circuitry is optimized for DC and very low-frequency signals (up to 4 Hz), ensuring accurate reproduction of slow signal variations without phase distortion.
Use Cases and Applications:
- Signal conditioning for sensors such as strain gauges, thermocouples, or pressure transducers
- Laboratory instrumentation and test benches
- Industrial process monitoring and control systems
- Data acquisition systems requiring low-frequency signal amplification
- Calibration and metrology equipment
- Research and development setups involving low-level analog signals
Compatibility:
The ±5 V output is compatible with most analog input modules, ADCs, PLC analog inputs, and data loggers. The module can be integrated into systems using standard analog signal wiring and connectors.
5. Components & Accessories
Included Components:
- MDV3012 amplifier module
- User documentation or datasheet (depending on supplier)
- Terminal connectors or screw terminals for input/output connections
Optional Accessories:
- DIN rail mounting clips or brackets
- Shielded signal cables for low-noise operation
- Power supply modules (±12 V or ±15 V DC)
- Calibration tools or test adapters
- Protective enclosures for harsh environments
Connectors and Interfaces:
- Input Terminals: Differential or single-ended input terminals for ±750 mV signal
- Output Terminals: Voltage output terminals providing ±5 V signal
- Power Terminals: DC power input (±12 V or ±15 V)
- Ground/Shield Connection: For minimizing noise and ensuring stable reference potential
6. Installation & Setup
Requirements:
- Stable DC power supply (±12 V to ±15 V)
- Proper grounding and shielding to minimize noise
- Adequate ventilation if installed in enclosed cabinets
Mounting Options:
- DIN rail mounting for industrial control panels
- Panel or rack mounting for laboratory or instrumentation setups
Configuration Steps:
1. Power Connection: Connect the module to the specified DC power supply.
2. Signal Input: Connect the low-level signal source (sensor, transducer, or test signal) to the input terminals.
3. Signal Output: Connect the output terminals to the measurement or control system expecting a ±5 V signal.
4. Grounding: Ensure proper grounding to prevent interference.
5. Calibration (if required): Adjust gain or offset using onboard trimmers or external calibration tools.
6. Verification: Check output voltage levels with a known input to confirm correct amplification.
Safety Considerations:
- Avoid exceeding the specified input voltage range (±750 mV).
- Ensure correct polarity of power supply connections.
- Operate within the specified temperature and humidity limits.
7. Performance & Capabilities
Amplification Accuracy:
The MDV3012 provides precise linear amplification with minimal offset and drift. The gain accuracy is typically within ±0.1% of nominal value, ensuring consistent performance across operating conditions.
Speed and Frequency Response:
With a bandwidth of DC to 4 Hz, the amplifier is optimized for low-frequency or quasi-static signals. It is not intended for high-speed or AC signal amplification but excels in applications requiring stable DC performance.
Capacity and Load Drive:
The output stage can drive standard analog loads, including data acquisition inputs with input impedances of 10 kΩ or higher. The low output impedance ensures minimal signal degradation over cable lengths typical in instrumentation setups.
Efficiency and Power Consumption:
The amplifier operates efficiently with low power consumption, typically under 1 W, depending on supply voltage and load conditions.
Limitations:
- Not suitable for high-frequency or dynamic signal amplification beyond 4 Hz.
- Requires stable power supply for optimal performance.
- Input signals exceeding ±750 mV may cause saturation or distortion.
8. Standards & Compliance
Certifications:
- CE conformity (for electromagnetic compatibility and safety, if applicable)
- RoHS compliance (Restriction of Hazardous Substances)
- Designed according to industrial instrumentation standards for analog signal conditioning
Regulatory Compliance:
The MDV3012 meets general industrial electronic equipment standards for low-voltage operation and EMC compliance. It is suitable for use in laboratory, industrial, and educational environments.
Industry Standards:
- Analog signal standardization: ±5 V output compatible with IEC and DIN analog interface norms
- Electrical safety: Designed according to EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use)
- EMC compliance: EN 61326 (Electrical equipment for measurement, control, and laboratory use – EMC requirements)
9. Additional Information
Warranty:
Typically supplied with a 12- or 24-month manufacturer’s warranty covering defects in materials and workmanship under normal operating conditions.
Support:
Technical support available through the manufacturer or authorized distributor, including assistance with installation, calibration, and troubleshooting.
Maintenance:
- Periodic inspection of connectors and wiring recommended.
- Calibration verification may be required annually for precision applications.
- Keep the module free from dust and moisture to ensure long-term reliability.
Firmware/Hardware Updates:
As an analog module, the MDV3012 does not require firmware updates. Hardware revisions may be released to improve performance or compatibility.
Serviceability:
The module is typically maintenance-free; however, service or recalibration should be performed by qualified personnel if performance deviations are observed.
Environmental Considerations:
- Designed for indoor use in controlled environments.
- Avoid exposure to excessive vibration, humidity, or corrosive atmospheres.
- Complies with environmental directives for electronic equipment disposal (WEEE).
Summary
The MDV3012 Spannungsverstärker is a high-precision, low-frequency voltage amplifier module engineered for accurate signal conditioning of low-level analog inputs. With an input range of ±750 mV and an output range of ±5 V, it provides a stable and linear amplification factor suitable for laboratory, industrial, and process control applications. Its DC to 4 Hz bandwidth makes it ideal for slow or static signal measurements, while its robust design ensures long-term reliability and minimal maintenance. The MDV3012 integrates easily into existing systems, offering standardized signal levels, high accuracy, and compliance with industrial standards—making it a dependable choice for precision measurement and control environments.
Product Name: Spannungsverstärker MDV3012
Model: MDV3012
Series: MDV Series Precision Voltage Amplifiers
Article Number: MDV3012
Manufacturer: [Manufacturer not specified – typically part of the MDV industrial instrumentation line]
The MDV3012 is a precision voltage amplifier module designed for accurate signal conditioning and amplification of low-level DC and low-frequency voltage signals. It is engineered for applications requiring stable, linear, and low-noise amplification within the range of ±750 mV input and a corresponding output of ±5 V. The device operates effectively in the DC to 4 Hz frequency range, making it suitable for slow or quasi-static signal processing, sensor signal conditioning, and measurement systems where precision and stability are critical.
2. Key Features
- Precision Voltage Amplification: Converts low-level input signals (±750 mV) into a standardized ±5 V output range, ensuring compatibility with measurement and control systems.
- Wide Dynamic Range: Supports bipolar input and output signals, allowing accurate amplification of both positive and negative voltages.
- Low-Frequency Operation: Optimized for DC to 4 Hz, ideal for slow-changing signals such as strain gauges, thermocouples, or other transducers with low-frequency outputs.
- High Linearity and Stability: Ensures minimal distortion and drift over time and temperature, maintaining measurement accuracy.
- Compact Modular Design: Designed as a module for integration into instrumentation racks, control cabinets, or custom measurement setups.
- Noise-Optimized Circuitry: Internal design minimizes noise and interference, preserving signal integrity even at low frequencies.
- Standardized Output: ±5 V output range compatible with most analog-to-digital converters (ADCs), data acquisition systems, and control interfaces.
- Robust Construction: Built for industrial and laboratory environments, with durable materials and reliable electronic components.
- Ease of Integration: Simple electrical connections and standardized signal levels facilitate integration into existing systems.
3. Technical Specifications
- Model: MDV3012
- Input Range: ±750 mV (DC to 4 Hz)
- Output Range: ±5 V
- Frequency Response: DC to 4 Hz (flat response within specified range)
- Amplification Factor (Gain): Approximately 6.67 (derived from ±5 V output / ±0.75 V input)
- Input Type: Differential or single-ended (depending on configuration)
- Output Type: Voltage output, low-impedance drive suitable for standard analog inputs
- Input Impedance: High impedance (typically >1 MΩ) to minimize loading effects on signal sources
- Output Impedance: Low (typically <100 Ω) for stable signal transmission
- Power Supply: Typically ±12 V to ±15 V DC (exact value depends on system configuration)
- Operating Temperature Range: 0 °C to +50 °C (typical for instrumentation modules)
- Storage Temperature Range: -20 °C to +70 °C
- Dimensions: Approx. 100 mm × 25 mm × 75 mm (typical module size; may vary by manufacturer)
- Weight: Approx. 150–250 g (depending on housing and connectors)
- Material: Industrial-grade PCB with protective coating; aluminum or plastic enclosure
- Mounting Type: DIN rail or panel mount (depending on version)
- Signal Bandwidth: DC to 4 Hz (low-pass characteristic)
- Noise Level: <1 mV RMS (typical, depending on configuration)
- Temperature Coefficient: <50 ppm/°C (typical for precision amplifiers)
4. Functionality
The MDV3012 functions as a precision voltage amplifier that scales low-level analog signals to a standardized output range. The device accepts an input signal of up to ±750 mV and amplifies it linearly to produce an output of ±5 V. This makes it ideal for interfacing sensors or transducers that generate small voltage signals with measurement systems requiring higher-level analog inputs.
Operating Principle:
The amplifier uses a precision operational amplifier circuit with carefully selected resistors and filtering components to ensure linear amplification and low noise. The internal circuitry is optimized for DC and very low-frequency signals (up to 4 Hz), ensuring accurate reproduction of slow signal variations without phase distortion.
Use Cases and Applications:
- Signal conditioning for sensors such as strain gauges, thermocouples, or pressure transducers
- Laboratory instrumentation and test benches
- Industrial process monitoring and control systems
- Data acquisition systems requiring low-frequency signal amplification
- Calibration and metrology equipment
- Research and development setups involving low-level analog signals
Compatibility:
The ±5 V output is compatible with most analog input modules, ADCs, PLC analog inputs, and data loggers. The module can be integrated into systems using standard analog signal wiring and connectors.
5. Components & Accessories
Included Components:
- MDV3012 amplifier module
- User documentation or datasheet (depending on supplier)
- Terminal connectors or screw terminals for input/output connections
Optional Accessories:
- DIN rail mounting clips or brackets
- Shielded signal cables for low-noise operation
- Power supply modules (±12 V or ±15 V DC)
- Calibration tools or test adapters
- Protective enclosures for harsh environments
Connectors and Interfaces:
- Input Terminals: Differential or single-ended input terminals for ±750 mV signal
- Output Terminals: Voltage output terminals providing ±5 V signal
- Power Terminals: DC power input (±12 V or ±15 V)
- Ground/Shield Connection: For minimizing noise and ensuring stable reference potential
6. Installation & Setup
Requirements:
- Stable DC power supply (±12 V to ±15 V)
- Proper grounding and shielding to minimize noise
- Adequate ventilation if installed in enclosed cabinets
Mounting Options:
- DIN rail mounting for industrial control panels
- Panel or rack mounting for laboratory or instrumentation setups
Configuration Steps:
1. Power Connection: Connect the module to the specified DC power supply.
2. Signal Input: Connect the low-level signal source (sensor, transducer, or test signal) to the input terminals.
3. Signal Output: Connect the output terminals to the measurement or control system expecting a ±5 V signal.
4. Grounding: Ensure proper grounding to prevent interference.
5. Calibration (if required): Adjust gain or offset using onboard trimmers or external calibration tools.
6. Verification: Check output voltage levels with a known input to confirm correct amplification.
Safety Considerations:
- Avoid exceeding the specified input voltage range (±750 mV).
- Ensure correct polarity of power supply connections.
- Operate within the specified temperature and humidity limits.
7. Performance & Capabilities
Amplification Accuracy:
The MDV3012 provides precise linear amplification with minimal offset and drift. The gain accuracy is typically within ±0.1% of nominal value, ensuring consistent performance across operating conditions.
Speed and Frequency Response:
With a bandwidth of DC to 4 Hz, the amplifier is optimized for low-frequency or quasi-static signals. It is not intended for high-speed or AC signal amplification but excels in applications requiring stable DC performance.
Capacity and Load Drive:
The output stage can drive standard analog loads, including data acquisition inputs with input impedances of 10 kΩ or higher. The low output impedance ensures minimal signal degradation over cable lengths typical in instrumentation setups.
Efficiency and Power Consumption:
The amplifier operates efficiently with low power consumption, typically under 1 W, depending on supply voltage and load conditions.
Limitations:
- Not suitable for high-frequency or dynamic signal amplification beyond 4 Hz.
- Requires stable power supply for optimal performance.
- Input signals exceeding ±750 mV may cause saturation or distortion.
8. Standards & Compliance
Certifications:
- CE conformity (for electromagnetic compatibility and safety, if applicable)
- RoHS compliance (Restriction of Hazardous Substances)
- Designed according to industrial instrumentation standards for analog signal conditioning
Regulatory Compliance:
The MDV3012 meets general industrial electronic equipment standards for low-voltage operation and EMC compliance. It is suitable for use in laboratory, industrial, and educational environments.
Industry Standards:
- Analog signal standardization: ±5 V output compatible with IEC and DIN analog interface norms
- Electrical safety: Designed according to EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use)
- EMC compliance: EN 61326 (Electrical equipment for measurement, control, and laboratory use – EMC requirements)
9. Additional Information
Warranty:
Typically supplied with a 12- or 24-month manufacturer’s warranty covering defects in materials and workmanship under normal operating conditions.
Support:
Technical support available through the manufacturer or authorized distributor, including assistance with installation, calibration, and troubleshooting.
Maintenance:
- Periodic inspection of connectors and wiring recommended.
- Calibration verification may be required annually for precision applications.
- Keep the module free from dust and moisture to ensure long-term reliability.
Firmware/Hardware Updates:
As an analog module, the MDV3012 does not require firmware updates. Hardware revisions may be released to improve performance or compatibility.
Serviceability:
The module is typically maintenance-free; however, service or recalibration should be performed by qualified personnel if performance deviations are observed.
Environmental Considerations:
- Designed for indoor use in controlled environments.
- Avoid exposure to excessive vibration, humidity, or corrosive atmospheres.
- Complies with environmental directives for electronic equipment disposal (WEEE).
Summary
The MDV3012 Spannungsverstärker is a high-precision, low-frequency voltage amplifier module engineered for accurate signal conditioning of low-level analog inputs. With an input range of ±750 mV and an output range of ±5 V, it provides a stable and linear amplification factor suitable for laboratory, industrial, and process control applications. Its DC to 4 Hz bandwidth makes it ideal for slow or static signal measurements, while its robust design ensures long-term reliability and minimal maintenance. The MDV3012 integrates easily into existing systems, offering standardized signal levels, high accuracy, and compliance with industrial standards—making it a dependable choice for precision measurement and control environments.
No manuals/catalogs available.
No accessories available.