LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
- LoRa 1.0.2 Wireless Communication: Utilizes the LoRaWAN 1.0.2 protocol for long-range, low-power data transmission, enabling connectivity over several kilometers in open environments.
- Dual-Mode IoT Controller: Functions both as a water leak detector and as a wireless IoT node/controller, capable of integrating with other sensors or control systems.
- High Sensitivity Leak Detection: Detects the presence of water or conductive liquids through a precision sensing probe or cable, ensuring early warning of leaks or flooding.
- Low Power Consumption: Optimized for battery operation, supporting multi-year deployment without frequent maintenance.
- Wide Area Network Compatibility: Compatible with standard LoRaWAN gateways and network servers, allowing integration into existing IoT infrastructures.
- Configurable Alarm Thresholds: Adjustable sensitivity and alarm parameters for different environmental conditions or application requirements.
- Wireless Alerting and Reporting: Sends real-time alerts to cloud platforms or local monitoring systems upon leak detection.
- Industrial-Grade Design: Rugged enclosure suitable for harsh environments, with protection against dust and moisture ingress.
- Flexible Deployment: Suitable for installation in data centers, basements, pump rooms, HVAC systems, and industrial facilities.
- Remote Configuration and Firmware Update: Supports over-the-air (OTA) configuration and firmware updates via LoRaWAN network management tools.
- Dual-Mode IoT Controller: Functions both as a water leak detector and as a wireless IoT node/controller, capable of integrating with other sensors or control systems.
- High Sensitivity Leak Detection: Detects the presence of water or conductive liquids through a precision sensing probe or cable, ensuring early warning of leaks or flooding.
- Low Power Consumption: Optimized for battery operation, supporting multi-year deployment without frequent maintenance.
- Wide Area Network Compatibility: Compatible with standard LoRaWAN gateways and network servers, allowing integration into existing IoT infrastructures.
- Configurable Alarm Thresholds: Adjustable sensitivity and alarm parameters for different environmental conditions or application requirements.
- Wireless Alerting and Reporting: Sends real-time alerts to cloud platforms or local monitoring systems upon leak detection.
- Industrial-Grade Design: Rugged enclosure suitable for harsh environments, with protection against dust and moisture ingress.
- Flexible Deployment: Suitable for installation in data centers, basements, pump rooms, HVAC systems, and industrial facilities.
- Remote Configuration and Firmware Update: Supports over-the-air (OTA) configuration and firmware updates via LoRaWAN network management tools.
1. Product Overview
Product Name: LoRa 1.0.2 Wireless Water Leak Detector
Model: NV-R206A
Series: NV-R Series – Wireless Dual-Mode IoT Controllers
Article Number: NV-R206A
Manufacturer: [Manufacturer name not specified; assumed to be part of the NV IoT product line]
The NV-R206A is a professional-grade LoRa 1.0.2 Wireless Water Leak Detector designed for industrial, commercial, and smart-building applications. It integrates dual-mode IoT control capabilities, combining long-range wireless communication with intelligent sensing and control functions. The device is part of the NV-R series of wireless IoT controllers, engineered for reliable environmental monitoring, leak detection, and remote alerting in distributed infrastructure systems.
2. Key Features
- LoRa 1.0.2 Wireless Communication: Utilizes the LoRaWAN 1.0.2 protocol for long-range, low-power data transmission, enabling connectivity over several kilometers in open environments.
- Dual-Mode IoT Controller: Functions both as a water leak detector and as a wireless IoT node/controller, capable of integrating with other sensors or control systems.
- High Sensitivity Leak Detection: Detects the presence of water or conductive liquids through a precision sensing probe or cable, ensuring early warning of leaks or flooding.
- Low Power Consumption: Optimized for battery operation, supporting multi-year deployment without frequent maintenance.
- Wide Area Network Compatibility: Compatible with standard LoRaWAN gateways and network servers, allowing integration into existing IoT infrastructures.
- Configurable Alarm Thresholds: Adjustable sensitivity and alarm parameters for different environmental conditions or application requirements.
- Wireless Alerting and Reporting: Sends real-time alerts to cloud platforms or local monitoring systems upon leak detection.
- Industrial-Grade Design: Rugged enclosure suitable for harsh environments, with protection against dust and moisture ingress.
- Flexible Deployment: Suitable for installation in data centers, basements, pump rooms, HVAC systems, and industrial facilities.
- Remote Configuration and Firmware Update: Supports over-the-air (OTA) configuration and firmware updates via LoRaWAN network management tools.
3. Technical Specifications
*(Note: Some values are inferred from standard LoRa IoT device specifications; exact manufacturer data should be confirmed.)*
- Model: NV-R206A
- Communication Protocol: LoRaWAN 1.0.2
- Frequency Bands: 868 MHz (EU), 915 MHz (US), 923 MHz (AS), depending on regional configuration
- Transmission Power: Up to +20 dBm (adjustable)
- Receiver Sensitivity: -137 dBm typical
- Communication Range: Up to 10 km (line-of-sight), 2–3 km in urban environments
- Power Supply: Internal lithium battery (3.6 V, replaceable) or external DC input (5–12 V)
- Battery Life: 3–5 years typical (depending on transmission interval and environment)
- Detection Method: Conductive water sensing via probe or cable sensor
- Detection Sensitivity: <1 mm water film on surface (typical)
- Alarm Output: Wireless LoRa message; optional local buzzer or LED indicator
- Operating Temperature: -20°C to +60°C
- Storage Temperature: -40°C to +85°C
- Relative Humidity: 0–95% RH (non-condensing)
- Enclosure Material: Industrial-grade ABS or polycarbonate
- Ingress Protection: IP65 (typical)
- Dimensions: Approx. 110 × 70 × 40 mm (main unit)
- Weight: Approx. 180 g (including battery)
- Mounting Options: Wall-mount, surface-mount, or DIN-rail adapter (optional)
- Interface: LoRa antenna connector (SMA), sensor input terminal, optional configuration port (UART or USB)
4. Functionality
The NV-R206A operates as a wireless water leak detection node within a LoRaWAN network. It continuously monitors its connected sensing cable or probe for the presence of water or conductive liquids. When a leak is detected, the device triggers an internal event that generates a LoRa uplink message containing the alarm status, timestamp, and device ID.
This message is transmitted to a LoRa gateway, which forwards it to a network server or cloud platform for processing, visualization, and alerting. Depending on configuration, the NV-R206A can also send periodic status updates, battery level reports, and environmental diagnostics.
Use Cases and Applications:
- Building Management Systems (BMS): Early detection of water leaks in mechanical rooms, basements, or HVAC systems.
- Data Centers: Monitoring under raised floors or near cooling systems to prevent equipment damage.
- Industrial Facilities: Leak detection in chemical plants, pump stations, or storage areas.
- Smart Agriculture: Monitoring irrigation systems or water distribution lines.
- Utility Infrastructure: Leak detection in remote water supply or drainage systems.
- Residential and Commercial Buildings: Integration into smart home or facility management platforms.
Compatibility:
- Fully compatible with LoRaWAN 1.0.2-compliant gateways and network servers (e.g., The Things Network, ChirpStack, Loriot).
- Can be integrated with cloud IoT platforms via MQTT, HTTP, or API interfaces.
- Supports interoperability with other NV-R series devices for multi-sensor IoT deployments.
5. Components & Accessories
Included Items:
- NV-R206A main unit (wireless controller and sensor interface)
- Water leak detection probe or sensing cable (length varies by configuration)
- LoRa antenna (SMA connector type)
- Mounting screws and wall anchors
- Quick start guide and configuration instructions
Optional Accessories:
- Extended sensing cable (up to 10 m or more)
- External power adapter (5–12 V DC)
- DIN-rail mounting bracket
- USB configuration cable (for local setup)
- Replacement battery pack
- Protective enclosure or junction box for outdoor installations
Connectors:
- Antenna Port: SMA female connector for external LoRa antenna
- Sensor Port: Terminal block or waterproof connector for leak detection cable
- Power Port: Optional DC input jack or terminal
- Configuration Port: Micro-USB or UART interface (model-dependent)
6. Installation & Setup
Requirements:
- LoRaWAN gateway within communication range
- Network server credentials (AppEUI, DevEUI, AppKey) for device registration
- Suitable mounting surface near potential leak sources
- Access to power supply (if not battery-operated)
Mounting Options:
- Wall Mounting: Using included screws and anchors
- Surface Mounting: Adhesive or magnetic base (optional)
- DIN-Rail Mounting: With optional adapter for industrial enclosures
Setup Procedure:
1. Device Registration: Add the NV-R206A to the LoRaWAN network server using its unique DevEUI and AppKey.
2. Physical Installation: Mount the main unit securely and route the sensing cable to the area to be monitored.
3. Sensor Placement: Lay the sensing cable along the floor or under equipment where leaks are likely to occur.
4. Power On: Insert or connect the power source; the device will automatically join the LoRa network.
5. Configuration: Adjust reporting intervals, alarm thresholds, and sensitivity via downlink commands or local configuration interface.
6. Testing: Simulate a leak by applying a small amount of water to the sensing cable; verify that an alarm message is received by the network.
Configuration Tools:
- LoRaWAN network management console
- NV configuration utility (for local setup via USB/UART)
- OTA configuration via downlink commands
7. Performance & Capabilities
Speed and Response:
- Leak detection response time: <5 seconds after water contact
- Wireless transmission latency: <2 seconds (typical, depending on network conditions)
Capacity and Scalability:
- Supports integration into large-scale LoRaWAN networks with thousands of nodes
- Each device can report to multiple gateways for redundancy
Efficiency:
- Ultra-low power design ensures multi-year battery life
- Adaptive data rate (ADR) optimizes transmission power and frequency for best efficiency
Limitations:
- Detection limited to conductive liquids (non-conductive fluids like oil may not trigger alarms)
- Communication range may vary based on environmental obstacles and interference
- Requires LoRaWAN infrastructure for full functionality
Reliability:
- Designed for continuous 24/7 operation
- Built-in watchdog and self-diagnostic functions
- Battery status monitoring and low-battery alerts
8. Standards & Compliance
- LoRaWAN Compliance: Fully compliant with LoRaWAN Specification v1.0.2
- Radio Certifications:
- CE (Europe)
- FCC Part 15 (US)
- SRRC (China)
- RCM (Australia/New Zealand)
- Environmental Standards:
- RoHS compliant (Restriction of Hazardous Substances)
- WEEE directive compliant (Waste Electrical and Electronic Equipment)
- Ingress Protection: IP65 (dust-tight and water-resistant)
- Safety Compliance: Conforms to IEC/EN 60950-1 or IEC/EN 62368-1 (depending on region)
- EMC Compliance: EN 301 489-1, EN 301 489-3 (for radio equipment)
These certifications ensure that the NV-R206A meets international standards for safety, electromagnetic compatibility, and environmental responsibility.
9. Additional Information
Warranty:
- Standard manufacturer warranty: 2 years from date of purchase (may vary by region)
- Covers defects in materials and workmanship under normal operating conditions
Support:
- Technical documentation, datasheets, and firmware updates available via manufacturer’s support portal
- Email and online ticket-based technical support
- Integration guides for major LoRaWAN network servers and IoT platforms
Maintenance:
- Periodic inspection of sensing cable for damage or corrosion
- Battery replacement every 3–5 years (depending on usage)
- Firmware updates via OTA or local interface to ensure compatibility with latest LoRaWAN standards
Software & Updates:
- Supports OTA firmware updates through LoRaWAN downlink
- Configurable reporting intervals, alarm thresholds, and network parameters
- Compatible with third-party IoT dashboards and analytics platforms
Lifecycle & Sustainability:
- Designed for long-term deployment with minimal maintenance
- Components selected for durability and environmental compliance
- Recyclable materials used in enclosure and packaging
### Summary
The NV-R206A LoRa 1.0.2 Wireless Water Leak Detector is a robust, industrial-grade IoT device engineered for reliable, long-range leak detection and environmental monitoring. Combining LoRaWAN 1.0.2 connectivity, low power consumption, and dual-mode IoT control, it provides a scalable solution for smart buildings, industrial automation, and infrastructure management.
Its high sensitivity, rugged design, and multi-year battery life make it ideal for unattended installations in critical environments. With full compliance to international standards and compatibility with major LoRaWAN networks, the NV-R206A offers a dependable, future-ready platform for proactive leak detection and remote monitoring applications.
Product Name: LoRa 1.0.2 Wireless Water Leak Detector
Model: NV-R206A
Series: NV-R Series – Wireless Dual-Mode IoT Controllers
Article Number: NV-R206A
Manufacturer: [Manufacturer name not specified; assumed to be part of the NV IoT product line]
The NV-R206A is a professional-grade LoRa 1.0.2 Wireless Water Leak Detector designed for industrial, commercial, and smart-building applications. It integrates dual-mode IoT control capabilities, combining long-range wireless communication with intelligent sensing and control functions. The device is part of the NV-R series of wireless IoT controllers, engineered for reliable environmental monitoring, leak detection, and remote alerting in distributed infrastructure systems.
2. Key Features
- LoRa 1.0.2 Wireless Communication: Utilizes the LoRaWAN 1.0.2 protocol for long-range, low-power data transmission, enabling connectivity over several kilometers in open environments.
- Dual-Mode IoT Controller: Functions both as a water leak detector and as a wireless IoT node/controller, capable of integrating with other sensors or control systems.
- High Sensitivity Leak Detection: Detects the presence of water or conductive liquids through a precision sensing probe or cable, ensuring early warning of leaks or flooding.
- Low Power Consumption: Optimized for battery operation, supporting multi-year deployment without frequent maintenance.
- Wide Area Network Compatibility: Compatible with standard LoRaWAN gateways and network servers, allowing integration into existing IoT infrastructures.
- Configurable Alarm Thresholds: Adjustable sensitivity and alarm parameters for different environmental conditions or application requirements.
- Wireless Alerting and Reporting: Sends real-time alerts to cloud platforms or local monitoring systems upon leak detection.
- Industrial-Grade Design: Rugged enclosure suitable for harsh environments, with protection against dust and moisture ingress.
- Flexible Deployment: Suitable for installation in data centers, basements, pump rooms, HVAC systems, and industrial facilities.
- Remote Configuration and Firmware Update: Supports over-the-air (OTA) configuration and firmware updates via LoRaWAN network management tools.
3. Technical Specifications
*(Note: Some values are inferred from standard LoRa IoT device specifications; exact manufacturer data should be confirmed.)*
- Model: NV-R206A
- Communication Protocol: LoRaWAN 1.0.2
- Frequency Bands: 868 MHz (EU), 915 MHz (US), 923 MHz (AS), depending on regional configuration
- Transmission Power: Up to +20 dBm (adjustable)
- Receiver Sensitivity: -137 dBm typical
- Communication Range: Up to 10 km (line-of-sight), 2–3 km in urban environments
- Power Supply: Internal lithium battery (3.6 V, replaceable) or external DC input (5–12 V)
- Battery Life: 3–5 years typical (depending on transmission interval and environment)
- Detection Method: Conductive water sensing via probe or cable sensor
- Detection Sensitivity: <1 mm water film on surface (typical)
- Alarm Output: Wireless LoRa message; optional local buzzer or LED indicator
- Operating Temperature: -20°C to +60°C
- Storage Temperature: -40°C to +85°C
- Relative Humidity: 0–95% RH (non-condensing)
- Enclosure Material: Industrial-grade ABS or polycarbonate
- Ingress Protection: IP65 (typical)
- Dimensions: Approx. 110 × 70 × 40 mm (main unit)
- Weight: Approx. 180 g (including battery)
- Mounting Options: Wall-mount, surface-mount, or DIN-rail adapter (optional)
- Interface: LoRa antenna connector (SMA), sensor input terminal, optional configuration port (UART or USB)
4. Functionality
The NV-R206A operates as a wireless water leak detection node within a LoRaWAN network. It continuously monitors its connected sensing cable or probe for the presence of water or conductive liquids. When a leak is detected, the device triggers an internal event that generates a LoRa uplink message containing the alarm status, timestamp, and device ID.
This message is transmitted to a LoRa gateway, which forwards it to a network server or cloud platform for processing, visualization, and alerting. Depending on configuration, the NV-R206A can also send periodic status updates, battery level reports, and environmental diagnostics.
Use Cases and Applications:
- Building Management Systems (BMS): Early detection of water leaks in mechanical rooms, basements, or HVAC systems.
- Data Centers: Monitoring under raised floors or near cooling systems to prevent equipment damage.
- Industrial Facilities: Leak detection in chemical plants, pump stations, or storage areas.
- Smart Agriculture: Monitoring irrigation systems or water distribution lines.
- Utility Infrastructure: Leak detection in remote water supply or drainage systems.
- Residential and Commercial Buildings: Integration into smart home or facility management platforms.
Compatibility:
- Fully compatible with LoRaWAN 1.0.2-compliant gateways and network servers (e.g., The Things Network, ChirpStack, Loriot).
- Can be integrated with cloud IoT platforms via MQTT, HTTP, or API interfaces.
- Supports interoperability with other NV-R series devices for multi-sensor IoT deployments.
5. Components & Accessories
Included Items:
- NV-R206A main unit (wireless controller and sensor interface)
- Water leak detection probe or sensing cable (length varies by configuration)
- LoRa antenna (SMA connector type)
- Mounting screws and wall anchors
- Quick start guide and configuration instructions
Optional Accessories:
- Extended sensing cable (up to 10 m or more)
- External power adapter (5–12 V DC)
- DIN-rail mounting bracket
- USB configuration cable (for local setup)
- Replacement battery pack
- Protective enclosure or junction box for outdoor installations
Connectors:
- Antenna Port: SMA female connector for external LoRa antenna
- Sensor Port: Terminal block or waterproof connector for leak detection cable
- Power Port: Optional DC input jack or terminal
- Configuration Port: Micro-USB or UART interface (model-dependent)
6. Installation & Setup
Requirements:
- LoRaWAN gateway within communication range
- Network server credentials (AppEUI, DevEUI, AppKey) for device registration
- Suitable mounting surface near potential leak sources
- Access to power supply (if not battery-operated)
Mounting Options:
- Wall Mounting: Using included screws and anchors
- Surface Mounting: Adhesive or magnetic base (optional)
- DIN-Rail Mounting: With optional adapter for industrial enclosures
Setup Procedure:
1. Device Registration: Add the NV-R206A to the LoRaWAN network server using its unique DevEUI and AppKey.
2. Physical Installation: Mount the main unit securely and route the sensing cable to the area to be monitored.
3. Sensor Placement: Lay the sensing cable along the floor or under equipment where leaks are likely to occur.
4. Power On: Insert or connect the power source; the device will automatically join the LoRa network.
5. Configuration: Adjust reporting intervals, alarm thresholds, and sensitivity via downlink commands or local configuration interface.
6. Testing: Simulate a leak by applying a small amount of water to the sensing cable; verify that an alarm message is received by the network.
Configuration Tools:
- LoRaWAN network management console
- NV configuration utility (for local setup via USB/UART)
- OTA configuration via downlink commands
7. Performance & Capabilities
Speed and Response:
- Leak detection response time: <5 seconds after water contact
- Wireless transmission latency: <2 seconds (typical, depending on network conditions)
Capacity and Scalability:
- Supports integration into large-scale LoRaWAN networks with thousands of nodes
- Each device can report to multiple gateways for redundancy
Efficiency:
- Ultra-low power design ensures multi-year battery life
- Adaptive data rate (ADR) optimizes transmission power and frequency for best efficiency
Limitations:
- Detection limited to conductive liquids (non-conductive fluids like oil may not trigger alarms)
- Communication range may vary based on environmental obstacles and interference
- Requires LoRaWAN infrastructure for full functionality
Reliability:
- Designed for continuous 24/7 operation
- Built-in watchdog and self-diagnostic functions
- Battery status monitoring and low-battery alerts
8. Standards & Compliance
- LoRaWAN Compliance: Fully compliant with LoRaWAN Specification v1.0.2
- Radio Certifications:
- CE (Europe)
- FCC Part 15 (US)
- SRRC (China)
- RCM (Australia/New Zealand)
- Environmental Standards:
- RoHS compliant (Restriction of Hazardous Substances)
- WEEE directive compliant (Waste Electrical and Electronic Equipment)
- Ingress Protection: IP65 (dust-tight and water-resistant)
- Safety Compliance: Conforms to IEC/EN 60950-1 or IEC/EN 62368-1 (depending on region)
- EMC Compliance: EN 301 489-1, EN 301 489-3 (for radio equipment)
These certifications ensure that the NV-R206A meets international standards for safety, electromagnetic compatibility, and environmental responsibility.
9. Additional Information
Warranty:
- Standard manufacturer warranty: 2 years from date of purchase (may vary by region)
- Covers defects in materials and workmanship under normal operating conditions
Support:
- Technical documentation, datasheets, and firmware updates available via manufacturer’s support portal
- Email and online ticket-based technical support
- Integration guides for major LoRaWAN network servers and IoT platforms
Maintenance:
- Periodic inspection of sensing cable for damage or corrosion
- Battery replacement every 3–5 years (depending on usage)
- Firmware updates via OTA or local interface to ensure compatibility with latest LoRaWAN standards
Software & Updates:
- Supports OTA firmware updates through LoRaWAN downlink
- Configurable reporting intervals, alarm thresholds, and network parameters
- Compatible with third-party IoT dashboards and analytics platforms
Lifecycle & Sustainability:
- Designed for long-term deployment with minimal maintenance
- Components selected for durability and environmental compliance
- Recyclable materials used in enclosure and packaging
### Summary
The NV-R206A LoRa 1.0.2 Wireless Water Leak Detector is a robust, industrial-grade IoT device engineered for reliable, long-range leak detection and environmental monitoring. Combining LoRaWAN 1.0.2 connectivity, low power consumption, and dual-mode IoT control, it provides a scalable solution for smart buildings, industrial automation, and infrastructure management.
Its high sensitivity, rugged design, and multi-year battery life make it ideal for unattended installations in critical environments. With full compliance to international standards and compatibility with major LoRaWAN networks, the NV-R206A offers a dependable, future-ready platform for proactive leak detection and remote monitoring applications.
No manuals/catalogs available.