cBP-3062A
SUCHEN SIE DIE PASSENDE
INDUSTRIELLE LÖSUNG?
Entdecken Sie Embedded-, Kommunikations- und Automatisierungslösungen für Ihre Anwendung.
- Universal AC Input Range: 85 – 265 VAC, 45 – 440 Hz, supporting global operation without manual voltage selection.
- Output Power: 150 W continuous total output, optimized for CompactPCI 3U systems.
- Redundant Operation: Supports dual‑redundant configurations for uninterrupted system power.
- Standard 47‑Pin Interface: Compliant with PICMG 2.11 power connector standard (Positronic PCIH47 series).
- Hot‑Swappable Design: Enables live insertion and removal without system shutdown.
- Compact 3U Form Factor: Fits standard 3U CompactPCI chassis and backplanes.
- High Efficiency: Typical conversion efficiency of approximately 73 %.
- Comprehensive Protection: Over‑current, over‑voltage, under‑voltage, surge, and thermal protection with automatic recovery.
- Status Indicators: Front‑panel LEDs for Power (ON/OK) and Fault (FAIL) conditions.
- Parallel Current Sharing: Supports load sharing across multiple units on +5 V and +3.3 V rails.
- Safety and EMC Compliance: Meets UL 1950, CSA C22.2 No. 950, EN 60950, and CE EMI/EMS standards.
- Industrial‑Grade Reliability: MTBF > 100,000 hours (MIL‑HDBK‑217E), designed for 24/7 operation.
- Operating Temperature Range: 0 °C – 70 °C (full power to 40 °C with forced air).
- Output Power: 150 W continuous total output, optimized for CompactPCI 3U systems.
- Redundant Operation: Supports dual‑redundant configurations for uninterrupted system power.
- Standard 47‑Pin Interface: Compliant with PICMG 2.11 power connector standard (Positronic PCIH47 series).
- Hot‑Swappable Design: Enables live insertion and removal without system shutdown.
- Compact 3U Form Factor: Fits standard 3U CompactPCI chassis and backplanes.
- High Efficiency: Typical conversion efficiency of approximately 73 %.
- Comprehensive Protection: Over‑current, over‑voltage, under‑voltage, surge, and thermal protection with automatic recovery.
- Status Indicators: Front‑panel LEDs for Power (ON/OK) and Fault (FAIL) conditions.
- Parallel Current Sharing: Supports load sharing across multiple units on +5 V and +3.3 V rails.
- Safety and EMC Compliance: Meets UL 1950, CSA C22.2 No. 950, EN 60950, and CE EMI/EMS standards.
- Industrial‑Grade Reliability: MTBF > 100,000 hours (MIL‑HDBK‑217E), designed for 24/7 operation.
- Operating Temperature Range: 0 °C – 70 °C (full power to 40 °C with forced air).
Comprehensive Product Summary: ADLINK cPWR‑1500A CompactPCI Power Supply
### 1. Product Overview
Product Name: cPWR‑1500A
Model: cPWR‑1500A
Series: cPCI 3U Power Supply Series
Article Number: cPWR‑1500A
Manufacturer: ADLINK Technology Inc.
Product Type: CompactPCI 3U redundant AC power supply module
Description: 47‑pin CompactPCI power supply unit, 85–265 VAC input, 150 W output capacity, designed for 3U CompactPCI systems with redundant power configurations.
The cPWR‑1500A is part of ADLINK’s NuIPC® CompactPCI subsystem family, engineered for industrial and embedded computing platforms requiring high‑reliability power delivery in modular, hot‑swappable configurations. It conforms to the PICMG 2.11 CompactPCI Power Interface Specification and integrates seamlessly with ADLINK’s cPCIS‑1000/2000 chassis and backplane assemblies.
### 2. Key Features
- Universal AC Input Range: 85 – 265 VAC, 45 – 440 Hz, supporting global operation without manual voltage selection.
- Output Power: 150 W continuous total output, optimized for CompactPCI 3U systems.
- Redundant Operation: Supports dual‑redundant configurations for uninterrupted system power.
- Standard 47‑Pin Interface: Compliant with PICMG 2.11 power connector standard (Positronic PCIH47 series).
- Hot‑Swappable Design: Enables live insertion and removal without system shutdown.
- Compact 3U Form Factor: Fits standard 3U CompactPCI chassis and backplanes.
- High Efficiency: Typical conversion efficiency of approximately 73 %.
- Comprehensive Protection: Over‑current, over‑voltage, under‑voltage, surge, and thermal protection with automatic recovery.
- Status Indicators: Front‑panel LEDs for Power (ON/OK) and Fault (FAIL) conditions.
- Parallel Current Sharing: Supports load sharing across multiple units on +5 V and +3.3 V rails.
- Safety and EMC Compliance: Meets UL 1950, CSA C22.2 No. 950, EN 60950, and CE EMI/EMS standards.
- Industrial‑Grade Reliability: MTBF > 100,000 hours (MIL‑HDBK‑217E), designed for 24/7 operation.
- Operating Temperature Range: 0 °C – 70 °C (full power to 40 °C with forced air).
### 3. Technical Specifications
Electrical Input:
- Voltage Range: 85 – 265 VAC (single phase)
- Frequency: 45 – 440 Hz
- Input Current: ≤ 3.1 A @ 90 VAC full load
- Inrush Current: < 40 A @ 240 VAC
- Power Factor: 0.99 typical
- Efficiency: ≈ 73 % typical
Electrical Output:
| Output | Voltage | Max Current | Regulation | Ripple (p‑p) |
|---------|----------|--------------|-------------|--------------|
| +5 V | 5 V DC | 20 A (max), 2 A min | ±3 % | 1.0 % |
| +3.3 V | 3.3 V DC | 12 A | ±5 % | 1.5 % |
| +12 V | 12 V DC | 2 A | ±5 % | 1.0 % |
| −12 V | −12 V DC | 1 A | ±5 % | 1.0 % |
- Combined Output Power: 150 W continuous
- Hold‑Up Time: > 6 ms
- Rise Time: < 200 ms
- Temperature Coefficient: 0.05 % / °C
- Current Sharing: ±10 % on +5 V rail when paralleled
Mechanical:
- Form Factor: 3U CompactPCI module
- Connector: 47‑pin Positronic PCIH47M400A1 (male)
- Dimensions (typical): 40 (W) × 128.5 (H) × 172.8 (D) mm
- Weight: ≈ 0.85 kg
- Cooling: Forced‑air (≥ 15 CFM recommended)
Environmental:
- Operating Temperature: 0 °C – 70 °C (full load to 40 °C)
- Storage Temperature: −40 °C – +85 °C
- Relative Humidity: < 95 % @ 40 °C, non‑condensing
- Operating Altitude: ≤ 6,400 m
- Vibration: 5 – 55 Hz, 0.38 mm displacement, 2 cycles/axis
- Shock: per IEC 68‑2‑6
### 4. Functionality
The cPWR‑1500A converts universal AC mains input into regulated DC outputs required by CompactPCI backplanes and modules. It employs active power‑factor correction and high‑frequency switching (≈ 100 kHz) for efficient conversion. The unit interfaces through a 47‑pin connector providing power rails, sense lines, control, and status signals.
Typical Use Cases:
- Industrial automation controllers
- Telecommunications and networking CompactPCI systems
- Embedded computing platforms requiring redundant power
- Test and measurement instrumentation
Compatibility:
- Fully compatible with ADLINK cBP‑3062 and other 47‑pin PICMG 2.11 backplanes.
- Integrates with cPCIS‑2000 and cPCIS‑1000 chassis families.
- Supports mixed redundant operation with identical 47‑pin PSU modules.
### 5. Components & Accessories
Included Components:
- cPWR‑1500A power supply module
- Front‑panel handle and latch mechanism
- LED indicators (Power / Fault)
- 47‑pin Positronic interface connector
Optional Accessories:
- Redundant PSU backplane (cBP‑3062)
- AC input screw terminal block
- Power sharing cable harness
- Mounting rails for 3U chassis integration
Connectors and Signals (summary):
- AC Inputs: ACL (Line), ACN (Neutral)
- DC Outputs: +5 V, +3.3 V, +12 V, −12 V, GND
- Control/Status: EN#, INH#, DEG#, FAL#, GA[2..0], V1/V2 SENSE, V1/V2 SHARE, CGND
### 6. Installation & Setup
Requirements:
- Compatible 3U/6U CompactPCI chassis with PICMG 2.11‑compliant 47‑pin socket (Positronic PCIH47F300A1).
- Adequate forced‑air cooling (≥ 15 CFM).
- Proper grounding to chassis earth.
Installation Steps:
1. Power off or ensure redundant PSU is active before insertion.
2. Align module with guide rails and insert until latch engages.
3. Verify mating connector type and orientation.
4. Observe LED indicators: green = power OK, red = fault.
5. For redundant systems, ensure both units share load evenly via current‑share lines.
Configuration:
- Sense lines (V1SENSE, V2SENSE) must connect to backplane power planes.
- INH# and EN# signals control output enable/disable.
- DEG# and FAL# provide derating and fault feedback to system management.
### 7. Performance & Capabilities
- Rated Output Power: 150 W continuous
- Efficiency: ≈ 73 % typical at nominal load
- Power Factor: 0.99 typical
- Hold‑Up Time: > 6 ms at full load
- Rise Time: < 200 ms
- MTBF: > 100,000 hours (MIL‑HDBK‑217E)
- MTTR: ≈ 5 minutes (module replacement)
- Load Regulation: ±1 % (+5 V), ±3 % (+3.3 V, ±12 V)
- Line Regulation: ±0.3 %
- Operating Temperature Derating: Full power to 40 °C; linear derate to 70 °C.
- Noise & Ripple: ≤ 100 mV p‑p or 1 % of output voltage.
Limitations:
- Minimum load requirement: 2 A @ +5 V for stable regulation.
- Forced‑air cooling mandatory for full‑load operation above 40 °C.
- Interoperability of current‑share signals between different manufacturers not guaranteed.
### 8. Standards & Compliance
Electrical and Safety:
- UL 1950
- CSA C22.2 No. 950
- EN 60950 / TÜV certified
EMC / EMI / EMS:
- FCC Part 15 Class A
- EN 55022 Class A (radiated and conducted)
- EN 61000‑3‑2 (1995) / EN 61000‑3‑3 (harmonics and flicker)
- EN 50082‑2 (industrial immunity)
- EN 61000‑4‑2 (ESD)
- EN 61000‑4‑3 (RF immunity)
- EN 61000‑4‑4 (EFT/burst)
- EN 61000‑4‑6 (conducted RF)
- EN 61000‑4‑8 (magnetic field)
- ENV 50204 (radiated field from digital communications)
Mechanical & Environmental:
- Conforms to PICMG 2.11 CompactPCI Power Interface Specification
- Meets IEC 68‑2‑6 vibration and shock requirements
### 9. Additional Information
Warranty:
- One‑year limited warranty from date of purchase against defects in materials and workmanship.
- Warranty excludes damage from misuse, modification, or operation beyond specified limits.
Support & Service:
ADLINK Technology Inc.
9F, No. 166, Jian Yi Road, Chungho City, Taipei 235, Taiwan R.O.C.
Tel: +886‑2‑8226‑5877 Fax: +886‑2‑8226‑5717
Web: [www.adlinktech.com](http://www.adlinktech.com)
Email: service@adlink.com.tw
Maintenance:
- Periodically inspect and clean air filters and fans in the host chassis.
- Verify connector integrity and grounding.
- Replace PSU module if fault LED persists after power cycling.
Firmware / Updates:
The cPWR‑1500A is a hardware‑only device; no firmware updates are required.
Recommended Operating Practices:
- Use within specified environmental limits.
- Ensure redundant PSU synchronization for mission‑critical systems.
- Maintain proper airflow and avoid obstruction of ventilation paths.
### Summary
The ADLINK cPWR‑1500A is a robust, industrial‑grade 3U CompactPCI 150 W redundant AC power supply designed for high‑availability embedded systems. With its wide AC input range (85–265 VAC), 47‑pin PICMG 2.11 interface, and hot‑swappable modular design, it ensures reliable, uninterrupted power delivery in demanding environments. Comprehensive protection circuits, international safety certifications, and compatibility with ADLINK’s cPCIS chassis and backplanes make it an ideal choice for industrial automation, telecommunications, and embedded computing applications requiring compact, redundant, and serviceable power solutions.
### 1. Product Overview
Product Name: cPWR‑1500A
Model: cPWR‑1500A
Series: cPCI 3U Power Supply Series
Article Number: cPWR‑1500A
Manufacturer: ADLINK Technology Inc.
Product Type: CompactPCI 3U redundant AC power supply module
Description: 47‑pin CompactPCI power supply unit, 85–265 VAC input, 150 W output capacity, designed for 3U CompactPCI systems with redundant power configurations.
The cPWR‑1500A is part of ADLINK’s NuIPC® CompactPCI subsystem family, engineered for industrial and embedded computing platforms requiring high‑reliability power delivery in modular, hot‑swappable configurations. It conforms to the PICMG 2.11 CompactPCI Power Interface Specification and integrates seamlessly with ADLINK’s cPCIS‑1000/2000 chassis and backplane assemblies.
### 2. Key Features
- Universal AC Input Range: 85 – 265 VAC, 45 – 440 Hz, supporting global operation without manual voltage selection.
- Output Power: 150 W continuous total output, optimized for CompactPCI 3U systems.
- Redundant Operation: Supports dual‑redundant configurations for uninterrupted system power.
- Standard 47‑Pin Interface: Compliant with PICMG 2.11 power connector standard (Positronic PCIH47 series).
- Hot‑Swappable Design: Enables live insertion and removal without system shutdown.
- Compact 3U Form Factor: Fits standard 3U CompactPCI chassis and backplanes.
- High Efficiency: Typical conversion efficiency of approximately 73 %.
- Comprehensive Protection: Over‑current, over‑voltage, under‑voltage, surge, and thermal protection with automatic recovery.
- Status Indicators: Front‑panel LEDs for Power (ON/OK) and Fault (FAIL) conditions.
- Parallel Current Sharing: Supports load sharing across multiple units on +5 V and +3.3 V rails.
- Safety and EMC Compliance: Meets UL 1950, CSA C22.2 No. 950, EN 60950, and CE EMI/EMS standards.
- Industrial‑Grade Reliability: MTBF > 100,000 hours (MIL‑HDBK‑217E), designed for 24/7 operation.
- Operating Temperature Range: 0 °C – 70 °C (full power to 40 °C with forced air).
### 3. Technical Specifications
Electrical Input:
- Voltage Range: 85 – 265 VAC (single phase)
- Frequency: 45 – 440 Hz
- Input Current: ≤ 3.1 A @ 90 VAC full load
- Inrush Current: < 40 A @ 240 VAC
- Power Factor: 0.99 typical
- Efficiency: ≈ 73 % typical
Electrical Output:
| Output | Voltage | Max Current | Regulation | Ripple (p‑p) |
|---------|----------|--------------|-------------|--------------|
| +5 V | 5 V DC | 20 A (max), 2 A min | ±3 % | 1.0 % |
| +3.3 V | 3.3 V DC | 12 A | ±5 % | 1.5 % |
| +12 V | 12 V DC | 2 A | ±5 % | 1.0 % |
| −12 V | −12 V DC | 1 A | ±5 % | 1.0 % |
- Combined Output Power: 150 W continuous
- Hold‑Up Time: > 6 ms
- Rise Time: < 200 ms
- Temperature Coefficient: 0.05 % / °C
- Current Sharing: ±10 % on +5 V rail when paralleled
Mechanical:
- Form Factor: 3U CompactPCI module
- Connector: 47‑pin Positronic PCIH47M400A1 (male)
- Dimensions (typical): 40 (W) × 128.5 (H) × 172.8 (D) mm
- Weight: ≈ 0.85 kg
- Cooling: Forced‑air (≥ 15 CFM recommended)
Environmental:
- Operating Temperature: 0 °C – 70 °C (full load to 40 °C)
- Storage Temperature: −40 °C – +85 °C
- Relative Humidity: < 95 % @ 40 °C, non‑condensing
- Operating Altitude: ≤ 6,400 m
- Vibration: 5 – 55 Hz, 0.38 mm displacement, 2 cycles/axis
- Shock: per IEC 68‑2‑6
### 4. Functionality
The cPWR‑1500A converts universal AC mains input into regulated DC outputs required by CompactPCI backplanes and modules. It employs active power‑factor correction and high‑frequency switching (≈ 100 kHz) for efficient conversion. The unit interfaces through a 47‑pin connector providing power rails, sense lines, control, and status signals.
Typical Use Cases:
- Industrial automation controllers
- Telecommunications and networking CompactPCI systems
- Embedded computing platforms requiring redundant power
- Test and measurement instrumentation
Compatibility:
- Fully compatible with ADLINK cBP‑3062 and other 47‑pin PICMG 2.11 backplanes.
- Integrates with cPCIS‑2000 and cPCIS‑1000 chassis families.
- Supports mixed redundant operation with identical 47‑pin PSU modules.
### 5. Components & Accessories
Included Components:
- cPWR‑1500A power supply module
- Front‑panel handle and latch mechanism
- LED indicators (Power / Fault)
- 47‑pin Positronic interface connector
Optional Accessories:
- Redundant PSU backplane (cBP‑3062)
- AC input screw terminal block
- Power sharing cable harness
- Mounting rails for 3U chassis integration
Connectors and Signals (summary):
- AC Inputs: ACL (Line), ACN (Neutral)
- DC Outputs: +5 V, +3.3 V, +12 V, −12 V, GND
- Control/Status: EN#, INH#, DEG#, FAL#, GA[2..0], V1/V2 SENSE, V1/V2 SHARE, CGND
### 6. Installation & Setup
Requirements:
- Compatible 3U/6U CompactPCI chassis with PICMG 2.11‑compliant 47‑pin socket (Positronic PCIH47F300A1).
- Adequate forced‑air cooling (≥ 15 CFM).
- Proper grounding to chassis earth.
Installation Steps:
1. Power off or ensure redundant PSU is active before insertion.
2. Align module with guide rails and insert until latch engages.
3. Verify mating connector type and orientation.
4. Observe LED indicators: green = power OK, red = fault.
5. For redundant systems, ensure both units share load evenly via current‑share lines.
Configuration:
- Sense lines (V1SENSE, V2SENSE) must connect to backplane power planes.
- INH# and EN# signals control output enable/disable.
- DEG# and FAL# provide derating and fault feedback to system management.
### 7. Performance & Capabilities
- Rated Output Power: 150 W continuous
- Efficiency: ≈ 73 % typical at nominal load
- Power Factor: 0.99 typical
- Hold‑Up Time: > 6 ms at full load
- Rise Time: < 200 ms
- MTBF: > 100,000 hours (MIL‑HDBK‑217E)
- MTTR: ≈ 5 minutes (module replacement)
- Load Regulation: ±1 % (+5 V), ±3 % (+3.3 V, ±12 V)
- Line Regulation: ±0.3 %
- Operating Temperature Derating: Full power to 40 °C; linear derate to 70 °C.
- Noise & Ripple: ≤ 100 mV p‑p or 1 % of output voltage.
Limitations:
- Minimum load requirement: 2 A @ +5 V for stable regulation.
- Forced‑air cooling mandatory for full‑load operation above 40 °C.
- Interoperability of current‑share signals between different manufacturers not guaranteed.
### 8. Standards & Compliance
Electrical and Safety:
- UL 1950
- CSA C22.2 No. 950
- EN 60950 / TÜV certified
EMC / EMI / EMS:
- FCC Part 15 Class A
- EN 55022 Class A (radiated and conducted)
- EN 61000‑3‑2 (1995) / EN 61000‑3‑3 (harmonics and flicker)
- EN 50082‑2 (industrial immunity)
- EN 61000‑4‑2 (ESD)
- EN 61000‑4‑3 (RF immunity)
- EN 61000‑4‑4 (EFT/burst)
- EN 61000‑4‑6 (conducted RF)
- EN 61000‑4‑8 (magnetic field)
- ENV 50204 (radiated field from digital communications)
Mechanical & Environmental:
- Conforms to PICMG 2.11 CompactPCI Power Interface Specification
- Meets IEC 68‑2‑6 vibration and shock requirements
### 9. Additional Information
Warranty:
- One‑year limited warranty from date of purchase against defects in materials and workmanship.
- Warranty excludes damage from misuse, modification, or operation beyond specified limits.
Support & Service:
ADLINK Technology Inc.
9F, No. 166, Jian Yi Road, Chungho City, Taipei 235, Taiwan R.O.C.
Tel: +886‑2‑8226‑5877 Fax: +886‑2‑8226‑5717
Web: [www.adlinktech.com](http://www.adlinktech.com)
Email: service@adlink.com.tw
Maintenance:
- Periodically inspect and clean air filters and fans in the host chassis.
- Verify connector integrity and grounding.
- Replace PSU module if fault LED persists after power cycling.
Firmware / Updates:
The cPWR‑1500A is a hardware‑only device; no firmware updates are required.
Recommended Operating Practices:
- Use within specified environmental limits.
- Ensure redundant PSU synchronization for mission‑critical systems.
- Maintain proper airflow and avoid obstruction of ventilation paths.
### Summary
The ADLINK cPWR‑1500A is a robust, industrial‑grade 3U CompactPCI 150 W redundant AC power supply designed for high‑availability embedded systems. With its wide AC input range (85–265 VAC), 47‑pin PICMG 2.11 interface, and hot‑swappable modular design, it ensures reliable, uninterrupted power delivery in demanding environments. Comprehensive protection circuits, international safety certifications, and compatibility with ADLINK’s cPCIS chassis and backplanes make it an ideal choice for industrial automation, telecommunications, and embedded computing applications requiring compact, redundant, and serviceable power solutions.