EX9015H-M

6 AD,16-bit,12Hz,RTD:Pt,Ni,Cu,(2/3 wire),open loop detection, off-set, Individual Ch.Config. Parity setting(non),Modbus,50 & 60Hz rejection w WDT
308,00 EUR

inkl. Umsatzsteuer 366,52 EUR

  • Hersteller TOPSCCC
  • Kategorie: Modbus AD In
  • The EX9015H‑M is a high‑precision, 6‑channel analog input module designed for direct connection to resistance temperature detectors (RTDs). It operates as a Modbus RTU slave device over RS‑485 and provides 16‑bit resolution temperature measurement for platinum, nickel, and copper RTD sensors. The module is part of the EX‑9000 modular I/O family, offering robust isolation, flexible configuration, and industrial‑grade reliability for distributed temperature monitoring and process control systems.
- 6 Differential Analog Input Channels: Each channel is individually configurable for 2‑ or 3‑wire RTD sensors (Pt, Ni, Cu).
- High‑Resolution Measurement: 16‑bit analog‑to‑digital conversion using a 24‑bit sigma‑delta ADC core for superior accuracy and stability.
- Sampling Rate: 12 samples per second (12 Hz) per channel.
- Sensor Compatibility: Supports Pt100, Pt1000, Ni120, Cu100, Cu1000, and Cu50 RTDs with selectable α coefficients (0.00385, 0.003916, 0.00421, 0.00427, 0.00672).
- Open‑Loop Detection: Built‑in wire break detection for each channel.
- Individual Channel Configuration: Each input can be assigned a unique RTD type and range.
- Parity and Communication Settings: Supports None, Even, or Odd parity; baud rates from 1200 bps to 115200 bps.
- Modbus RTU Protocol: Fully compliant with Modbus RTU over RS‑485 for easy integration with PLCs, HMIs, and SCADA systems.
- High Isolation: 3000 VDC inter‑module isolation ensures signal integrity and protection against ground loops.
- Noise Rejection: 50 Hz and 60 Hz rejection filters with 150 dB CMR and 100 dB NMR minimum.
- Watchdog Timer (WDT): Hardware and host watchdogs for system reliability.
- Offset Adjustment: Per‑channel offset calibration via EX‑9000 utility software.
- Wide Operating Range: ‑25 °C to +75 °C operation for industrial environments.
- Compact, DIN‑rail Mountable Design: Suitable for distributed control panels and field installations.

Ursprungsland: Taiwan R.O.C.

Zolltarifnummer: 8517 6200 900

Comprehensive Product Summary – EX9015H‑M Analog Input Module




### 1. Product Overview

Product Name: EX9015H‑M
Model: EX9015H‑M
Series: EX‑9000 Series Distributed I/O Modules
Article Number: EX9015H‑M
Manufacturer: ICP DAS / TOPSCCC (EX‑9000 Series Family)

The EX9015H‑M is a high‑precision, 6‑channel analog input module designed for direct connection to resistance temperature detectors (RTDs). It operates as a Modbus RTU slave device over RS‑485 and provides 16‑bit resolution temperature measurement for platinum, nickel, and copper RTD sensors. The module is part of the EX‑9000 modular I/O family, offering robust isolation, flexible configuration, and industrial‑grade reliability for distributed temperature monitoring and process control systems.




### 2. Key Features

- 6 Differential Analog Input Channels: Each channel is individually configurable for 2‑ or 3‑wire RTD sensors (Pt, Ni, Cu).
- High‑Resolution Measurement: 16‑bit analog‑to‑digital conversion using a 24‑bit sigma‑delta ADC core for superior accuracy and stability.
- Sampling Rate: 12 samples per second (12 Hz) per channel.
- Sensor Compatibility: Supports Pt100, Pt1000, Ni120, Cu100, Cu1000, and Cu50 RTDs with selectable α coefficients (0.00385, 0.003916, 0.00421, 0.00427, 0.00672).
- Open‑Loop Detection: Built‑in wire break detection for each channel.
- Individual Channel Configuration: Each input can be assigned a unique RTD type and range.
- Parity and Communication Settings: Supports None, Even, or Odd parity; baud rates from 1200 bps to 115200 bps.
- Modbus RTU Protocol: Fully compliant with Modbus RTU over RS‑485 for easy integration with PLCs, HMIs, and SCADA systems.
- High Isolation: 3000 VDC inter‑module isolation ensures signal integrity and protection against ground loops.
- Noise Rejection: 50 Hz and 60 Hz rejection filters with 150 dB CMR and 100 dB NMR minimum.
- Watchdog Timer (WDT): Hardware and host watchdogs for system reliability.
- Offset Adjustment: Per‑channel offset calibration via EX‑9000 utility software.
- Wide Operating Range: ‑25 °C to +75 °C operation for industrial environments.
- Compact, DIN‑rail Mountable Design: Suitable for distributed control panels and field installations.




### 3. Technical Specifications

Analog Input
- Channels: 6 differential isolated inputs
- Input Type: 2‑ or 3‑wire RTD (channels 0–2 support 2/3/4‑wire; channels 3–5 support 2/3‑wire)
- Supported RTD Types:
- Pt100 (α = 0.00385, 0.003916)
- Pt1000 (α = 0.00385)
- Ni120 (α = 0.00672)
- Cu100 (α = 0.00421, 0.00427)
- Cu1000 (α = 0.00421)
- Cu50 (α = 0.00427)
- Resolution: 16 bits
- ADC Type: 24‑bit sigma‑delta converter
- Sampling Rate: 12 samples/sec
- Bandwidth: 5.24 Hz
- Accuracy: ±0.05 % of full scale
- Zero Drift: 0.5 µV/°C
- Span Drift: 20 µV/°C
- Common‑Mode Rejection (CMR): ≥ 150 dB @ 50/60 Hz
- Normal‑Mode Rejection (NMR): ≥ 100 dB @ 50/60 Hz
- Input Impedance: High impedance differential input
- Isolation Voltage: 3000 VDC inter‑module isolation

Power Requirements
- Supply Voltage: +10 VDC to +30 VDC
- Power Consumption: 1.1 W typical

Environmental
- Operating Temperature: ‑25 °C to +75 °C
- Storage Temperature: ‑30 °C to +75 °C
- Warm‑Up Time: 30 minutes recommended for full accuracy
- Humidity: 10 %–90 % RH, non‑condensing

Physical
- Mounting: DIN‑rail or panel mount
- Wiring: 26–12 AWG signal wires; shielded twisted pair recommended
- RS‑485 Cabling: 24 AWG twisted pair (e.g., Belden 9841)
- Isolation: Optical and galvanic isolation between channels and communication bus




### 4. Functionality

The EX9015H‑M functions as a Modbus RTU slave device that converts RTD resistance values into temperature readings. Each channel can be independently configured for a specific RTD type and temperature range. The module continuously samples each input at 12 Hz, applies digital filtering for 50/60 Hz noise rejection, and transmits the processed temperature data via RS‑485.

Use Cases and Applications:
- Industrial process temperature monitoring
- HVAC and building automation systems
- Energy management and environmental control
- Laboratory instrumentation and test benches
- Distributed data acquisition systems
- Integration with PLCs, SCADA, and DCS platforms

Compatibility:
- Modbus RTU master devices (PLCs, HMIs, PCs)
- EX‑9000 configuration utility software
- Standard RS‑485 networks (multi‑drop topology, up to 32 nodes per segment)




### 5. Components & Accessories

Included Items:
- EX9015H‑M module
- Removable terminal block connectors
- Quick start guide or CD with wiring diagrams and configuration software

Optional Accessories:
- RS‑485 communication cables
- DIN‑rail mounting clips
- External power supply (24 VDC typical)
- Shielded twisted‑pair signal cables
- Calibration resistors (for zero/span calibration)

Connectors:
- Screw‑type terminal blocks for signal and power
- RS‑485 communication terminals (D+, D‑, GND)
- INIT* terminal for configuration mode activation




### 6. Installation & Setup

Requirements:
- DC power supply (10–30 VDC)
- RS‑485 network connection
- Proper grounding and shielding for signal integrity

Mounting Options:
- DIN‑rail mounting in control cabinets
- Panel mounting with screws

Wiring Guidelines:
- Use shielded cables for RTD inputs; connect shield to A.GND terminal.
- For RS‑485, use twisted‑pair 24 AWG cable (Belden 9841 or equivalent).
- Maintain consistent polarity across all RS‑485 devices.

Configuration:
- Default module address: 01
- Default RTD type: Pt100 (Type 20, –100 °C to +100 °C)
- Default baud rate: 9600 bps
- Default parity: None
- Default filter: 60 Hz rejection
- Default data format: Engineering units

Setup Procedure:
1. Connect power and RS‑485 communication lines.
2. Configure module address and communication parameters using Modbus commands or EX‑9000 utility.
3. Assign RTD type and range per channel using `$AA7CiRrr` command.
4. Verify channel enable status with `$AA6`.
5. Perform calibration if required (zero and span).
6. Integrate with Modbus master system and verify data acquisition.




### 7. Performance & Capabilities

Measurement Performance:
- High‑accuracy temperature conversion with ±0.05 % error.
- Stable readings due to low drift and high CMR/NMR.
- 16‑bit resolution ensures fine temperature granularity.
- 12 Hz sampling rate suitable for slow‑changing thermal processes.

Capacity:
- Six independent RTD channels per module.
- Each channel configurable for different sensor types and ranges.
- Supports up to 32 modules on a single RS‑485 bus (address range 00–FF).

Efficiency and Reliability:
- Watchdog timers prevent communication lock‑ups.
- Host watchdog timeout configurable from 0.1 s to 25.5 s.
- EEPROM storage for configuration parameters.
- Automatic open‑loop detection for broken or disconnected sensors.

Limitations:
- Designed for RTD sensors only (no thermocouple or voltage input).
- Channels 3–5 limited to 2/3‑wire RTD connection (no 4‑wire).
- Requires warm‑up for optimal accuracy.




### 8. Standards & Compliance

- Communication Protocol: Modbus RTU (RS‑485, 8 data bits, 1 stop bit, selectable parity)
- Isolation Standard: 3000 VDC inter‑module isolation
- Noise Rejection: 50 Hz/60 Hz rejection filters compliant with industrial EMC requirements
- Electrical Safety: Designed for low‑voltage DC operation (10–30 VDC)
- Environmental Compliance: Industrial temperature range (‑25 °C to +75 °C)
- Quality Assurance: Factory‑calibrated with internal and external calibration options
- Regulatory: CE‑compliant (typical for EX‑9000 series), RoHS‑compliant materials




### 9. Additional Information

Calibration and Maintenance:
- Supports internal calibration (`$AAS0`) and factory default reload (`$AAS1`).
- Zero and span calibration per channel using `$AA0Ci` and `$AA1Ci` commands.
- Calibration resistors:
- Type 20 (Pt100): 0 Ω (Zero), 320 Ω (Span)
- Type 2A/2D (Pt1000/Cu1000): 0 Ω (Zero), 3000 Ω (Span)
- Calibration should only be performed by qualified personnel after 30 min warm‑up.

Firmware and Diagnostics:
- Firmware version readable via `$AAF` command.
- Module name readable and writable via `$AAM` and `~AAO(Data)` commands.
- Diagnostic command `$AAB` detects over‑range, under‑range, and wire‑open conditions.
- Host watchdog status and timeout configurable via `~AA0`, `~AA1`, `~AA2`, `~AA3EVV`.

Warranty and Support:
- Standard manufacturer warranty (typically 1 year, depending on distributor).
- Technical support and firmware updates available from ICP DAS/TOPSCCC.
- Configuration utilities and manuals downloadable from official website.

Maintenance Recommendations:
- Periodic verification of calibration accuracy.
- Ensure proper shielding and grounding to minimize noise.
- Inspect wiring connections regularly for corrosion or looseness.
- Maintain ambient temperature within specified range for long‑term stability.

Software Integration:
- Compatible with Modbus master software, SCADA systems, and custom applications.
- Configuration and monitoring via EX‑9000 Utility or Modbus commands.
- Supports synchronized sampling (`#` command) for multi‑module data acquisition.




###
Summary

The
EX9015H‑M is a robust, high‑accuracy 6‑channel RTD input module engineered for industrial temperature measurement applications. Its 16‑bit resolution, 3000 VDC isolation, and flexible per‑channel configuration make it ideal for distributed control systems requiring reliable and precise thermal data acquisition. With Modbus RTU communication, wide sensor compatibility, and comprehensive calibration and diagnostic functions, the EX9015H‑M delivers dependable performance in demanding environments such as manufacturing, energy management, and process automation.




End of Product Summary – EX9015H‑M**

Kein Zubehör vorhanden.