- Serial‑to‑Ethernet Conversion: Converts one RS‑422/485 serial interface into a standard 10/100Base‑T(X) Ethernet connection, enabling remote access and control of serial devices over IP networks.
- High Reliability: Supports Ethernet redundancy with recovery time under 10 ms, ensuring continuous communication in case of link failure.
- Multiple Operation Modes: Virtual COM, TCP Server, TCP Client, UDP, and Serial Tunnel modes for flexible deployment.
- Advanced Security: HTTPS, SSL, SSH, WEP/WPA/WPA2, 802.1X, Radius, and TKIP encryption for secure data transmission and management.
- Event Notification System: Real‑time alerts via Syslog, E‑mail, SNMP trap, relay output, and beeper for proactive fault management.
- Cross‑Platform Drivers: Virtual COM driver for Windows NT/2000/XP/2003/Vista and fixed TTY driver for Linux systems.
- Redundant Power Inputs: Dual 12–48 V DC inputs (terminal block and DC jack) with reverse polarity protection.
- Industrial‑Grade Design: Rugged metal enclosure (IP30 protection), 15 kV ESD protection, and 1.5 kV magnetic isolation on Ethernet port.
- Compact Form Factor: 72 × 31 × 125 mm (W × D × H) for space‑constrained installations.
- Flexible Mounting: DIN‑rail and wall‑mount options for versatile installation in control cabinets or equipment racks.
- Comprehensive Management Tools: IDS‑Tools Windows utility for device discovery, configuration, firmware updates, and monitoring.
- NAT Pass‑Through: Enables management through NAT routers, simplifying remote access across network boundaries.
- Up to Five Simultaneous Connections: Supports multiple concurrent sessions in Virtual COM, TCP Server, or Client modes.
- Long‑Term Reliability: 5‑year manufacturer warranty and industrial‑grade components for extended service life.
- High Reliability: Supports Ethernet redundancy with recovery time under 10 ms, ensuring continuous communication in case of link failure.
- Multiple Operation Modes: Virtual COM, TCP Server, TCP Client, UDP, and Serial Tunnel modes for flexible deployment.
- Advanced Security: HTTPS, SSL, SSH, WEP/WPA/WPA2, 802.1X, Radius, and TKIP encryption for secure data transmission and management.
- Event Notification System: Real‑time alerts via Syslog, E‑mail, SNMP trap, relay output, and beeper for proactive fault management.
- Cross‑Platform Drivers: Virtual COM driver for Windows NT/2000/XP/2003/Vista and fixed TTY driver for Linux systems.
- Redundant Power Inputs: Dual 12–48 V DC inputs (terminal block and DC jack) with reverse polarity protection.
- Industrial‑Grade Design: Rugged metal enclosure (IP30 protection), 15 kV ESD protection, and 1.5 kV magnetic isolation on Ethernet port.
- Compact Form Factor: 72 × 31 × 125 mm (W × D × H) for space‑constrained installations.
- Flexible Mounting: DIN‑rail and wall‑mount options for versatile installation in control cabinets or equipment racks.
- Comprehensive Management Tools: IDS‑Tools Windows utility for device discovery, configuration, firmware updates, and monitoring.
- NAT Pass‑Through: Enables management through NAT routers, simplifying remote access across network boundaries.
- Up to Five Simultaneous Connections: Supports multiple concurrent sessions in Virtual COM, TCP Server, or Client modes.
- Long‑Term Reliability: 5‑year manufacturer warranty and industrial‑grade components for extended service life.
1. Product Overview
Product Name: Serial 1×RS422/485 to Ethernet Device Server
Model: IDS‑2011
Series: IDS Industrial Device Server Series
Article Number: IDS‑2011
Manufacturer: SUNIX Co., Ltd. (Taiwan)
The SUNIX IDS‑2011 is a compact, industrial‑grade serial‑to‑Ethernet device server designed to connect legacy RS‑422/485 serial equipment to modern TCP/IP networks. It belongs to the SUNIX IDS series of Industrial Device Servers, which provide reliable, secure, and redundant networking for serial communication in industrial automation, data acquisition, and remote monitoring applications. The IDS‑2011 offers one RS‑422/485 serial port and one 10/100Base‑T(X) Ethernet port, supporting multiple communication modes and advanced management features for seamless integration into industrial Ethernet infrastructures.
2. Key Features
- Serial‑to‑Ethernet Conversion: Converts one RS‑422/485 serial interface into a standard 10/100Base‑T(X) Ethernet connection, enabling remote access and control of serial devices over IP networks.
- High Reliability: Supports Ethernet redundancy with recovery time under 10 ms, ensuring continuous communication in case of link failure.
- Multiple Operation Modes: Virtual COM, TCP Server, TCP Client, UDP, and Serial Tunnel modes for flexible deployment.
- Advanced Security: HTTPS, SSL, SSH, WEP/WPA/WPA2, 802.1X, Radius, and TKIP encryption for secure data transmission and management.
- Event Notification System: Real‑time alerts via Syslog, E‑mail, SNMP trap, relay output, and beeper for proactive fault management.
- Cross‑Platform Drivers: Virtual COM driver for Windows NT/2000/XP/2003/Vista and fixed TTY driver for Linux systems.
- Redundant Power Inputs: Dual 12–48 V DC inputs (terminal block and DC jack) with reverse polarity protection.
- Industrial‑Grade Design: Rugged metal enclosure (IP30 protection), 15 kV ESD protection, and 1.5 kV magnetic isolation on Ethernet port.
- Compact Form Factor: 72 × 31 × 125 mm (W × D × H) for space‑constrained installations.
- Flexible Mounting: DIN‑rail and wall‑mount options for versatile installation in control cabinets or equipment racks.
- Comprehensive Management Tools: IDS‑Tools Windows utility for device discovery, configuration, firmware updates, and monitoring.
- NAT Pass‑Through: Enables management through NAT routers, simplifying remote access across network boundaries.
- Up to Five Simultaneous Connections: Supports multiple concurrent sessions in Virtual COM, TCP Server, or Client modes.
- Long‑Term Reliability: 5‑year manufacturer warranty and industrial‑grade components for extended service life.
3. Technical Specifications
Serial Communication
- Port Type: 1 × RS‑422/485 (2‑wire or 4‑wire selectable)
- Connector: 5‑pin terminal block
- Baud Rate: 110 bps – 460.8 kbps
- Data Bits: 5, 6, 7, 8
- Parity: Odd, Even, None, Mark, Space
- Stop Bits: 1, 1.5, 2
- Flow Control: XON/XOFF, RTS/CTS, DTR/DSR
- RS‑422 Signals: TxD+, TxD−, RxD+, RxD−, GND
- RS‑485 (4‑wire): TxD+, TxD−, RxD+, RxD−, GND
- RS‑485 (2‑wire): Data+, Data−, GND
- ESD Protection: 15 kV
- Isolation: 1.5 kV magnetic isolation on Ethernet interface
Ethernet Interface
- Port: 1 × RJ‑45 10/100 Mbps (auto‑negotiation, Auto MDI/MDI‑X)
- Protocols Supported: ICMP, IP, TCP, UDP, DHCP, BootP, ARP/RARP, DNS, SNMP MIB II, HTTPS, SSL, SSH
- Operation Modes: Virtual COM, TCP Server, TCP Client, UDP, Serial Tunnel
- Redundancy: Ethernet redundancy with recovery < 10 ms
Power Requirements
- Input Voltage: 12 – 48 V DC (dual inputs: terminal block + DC jack)
- Power Consumption: Max 7 W
- Protection: Reverse polarity protection
Mechanical & Environmental
- Enclosure: Metal housing, IP30 protection
- Dimensions: 72 × 31 × 125 mm (W × D × H, without connectors)
- Mounting: DIN‑rail and wall‑mount options
- Weight: Approx. 0.4 kg (typical)
- Operating Temperature: −10 °C to 55 °C
- Storage Temperature: −20 °C to 85 °C
- Operating Humidity: 5 % – 95 % RH, non‑condensing
Certifications & Standards
- EMI: FCC Part 15, CISPR (EN55022) Class A
- EMS: EN61000‑4‑2 (ESD), EN61000‑4‑3 (RS), EN61000‑4‑4 (EFT), EN61000‑4‑5 (Surge Level 3), EN61000‑4‑6 (CS Level 3)
- Shock: IEC 60068‑2‑27
- Free Fall: IEC 60068‑2‑32
- Vibration: IEC 60068‑2‑6
- Compliance: CE Class A, RoHS
Warranty: 5 years
4. Functionality
The IDS‑2011 functions as a transparent bridge between serial and Ethernet networks. It encapsulates serial data into TCP/IP packets, allowing remote hosts to communicate with serial devices as if they were locally connected. The device supports multiple communication modes:
- Virtual COM Mode: Maps the serial port to a virtual COM port on a Windows host, enabling legacy applications to operate without modification.
- TCP Server Mode: Waits for incoming TCP connections from clients; supports up to five simultaneous connections.
- TCP Client Mode: Actively initiates a TCP connection to a designated server upon startup or data transmission.
- UDP Mode: Provides fast, connectionless data transfer for broadcast or multicast applications.
- Serial Tunnel Mode: Couples two IDS devices to create a serial‑over‑Ethernet tunnel, extending serial communication over long distances.
Use Cases & Applications:
- Industrial automation and PLC communication
- SCADA and remote monitoring systems
- Data acquisition and measurement equipment
- POS terminals and digital signage control
- Access control and card reader integration
- Medical instrumentation and laboratory systems
- Transportation and energy management networks
Compatibility:
- Operating Systems: Windows NT/2000/XP/2003/Vista (Virtual COM driver), Linux (TTY driver)
- Network Environments: Supports NAT pass‑through, DHCP, static IP, and DNS configurations.
- Management Interfaces: Web console (HTTPS), serial console, and IDS‑Tools Windows utility.
5. Components & Accessories
Included Items:
- IDS‑2011 Device Server unit
- Quick Installation Guide (QIG)
- DIN‑rail mount kit
- Wall‑mount kit
- Dust cover for connectors
- Software CD with IDS‑Tools utility and drivers
Optional Accessories:
- 12–48 V DC power adapter (sold separately)
- Additional DIN‑rail mounting brackets
- Terminal block connectors for custom wiring
Connectors:
- 5‑pin terminal block for RS‑422/485 serial port
- 3‑pin removable terminal block for power input
- DC jack for secondary power input
- RJ‑45 Ethernet port (10/100 Mbps)
6. Installation & Setup
Requirements:
- DC power supply (12–48 V DC, 7 W max)
- Standard CAT 5/5e Ethernet cable (up to 100 m)
- RS‑422/485 serial cable with 5‑pin terminal block connector
Mounting Options:
- DIN‑Rail Installation: Attach the included DIN‑rail clip to the rear panel and snap onto a standard 35 mm DIN rail.
- Wall Mounting: Remove the DIN‑rail kit and use the provided screws to secure the wall‑mount bracket.
Configuration Procedure:
1. Connect the power supply to PWR1 or PWR2 input.
2. Connect the Ethernet port to a LAN switch or router.
3. Connect the RS‑422/485 device to the serial port using the terminal block.
4. Install the IDS‑Tools utility on a Windows PC.
5. Discover the device (default IP 192.168.1.1) and assign a static or DHCP address.
6. Configure serial parameters (baud rate, data bits, parity, stop bits) and select the desired operation mode.
7. Save settings and reboot the device to apply changes.
Reset Function: Press and hold the reset button for 5 seconds to restore factory defaults.
7. Performance & Capabilities
- Ethernet Redundancy: Automatic failover within 10 ms ensures continuous operation in critical systems.
- Simultaneous Connections: Supports up to five concurrent TCP or Virtual COM sessions.
- Throughput: Optimized for high‑speed serial data transfer up to 460.8 kbps.
- Latency Optimization: Configurable for low‑latency or high‑throughput operation modes.
- Power Efficiency: Consumes less than 7 W under full load.
- Reliability: Dual power inputs and redundant Ethernet design minimize downtime.
- Limitations: Single serial port model — for multi‑port applications, SUNIX offers IDS‑3012 and IDS‑3042 variants.
8. Standards & Compliance
The IDS‑2011 meets international industrial and electromagnetic compatibility standards for safe and reliable operation in harsh environments.
- EMI Compliance: FCC Part 15 Class A, CISPR (EN55022) Class A
- EMS Immunity: EN61000‑4‑2 (ESD), EN61000‑4‑3 (RS), EN61000‑4‑4 (EFT), EN61000‑4‑5 (Surge Level 3), EN61000‑4‑6 (CS Level 3)
- Environmental Testing: IEC 60068‑2‑27 (Shock), IEC 60068‑2‑32 (Free Fall), IEC 60068‑2‑6 (Vibration)
- Safety & Reliability: IP30 metal enclosure for industrial protection, RoHS compliant materials.
- Network Security Standards: Supports HTTPS (SSL), SSH, 802.1X authentication, and Radius integration for secure management.
9. Additional Information
Warranty & Support:
- 5‑year limited hardware warranty from SUNIX Co., Ltd.
- Technical support available via email (info@sunix.com.tw) and official website (www.sunix.com.tw).
- Firmware and driver updates provided through the SUNIX support portal.
Maintenance:
- Periodically check terminal connections and clean ventilation openings.
- Use IDS‑Tools for firmware updates and configuration backups.
- Maintain redundant power and network connections for maximum uptime.
Software Updates & Utilities:
- IDS‑Tools Utility: Provides device discovery, group configuration, firmware upgrade, and monitoring functions.
- Web Management Interface: Accessible via HTTPS for configuration and status monitoring.
- SSH Console: Secure command‑line access for advanced users.
Manufacturer Contact:
SUNIX Co., Ltd.
Tel: +886‑2‑8913‑1987 Fax: +886‑2‑8913‑1986
Email: info@sunix.com.tw Website: [www.sunix.com.tw](http://www.sunix.com.tw)
### Summary
The SUNIX IDS‑2011 is a robust, industrial‑grade 1‑port RS‑422/485 to Ethernet device server engineered for mission‑critical applications requiring secure, redundant, and high‑performance serial communication over IP networks. Its combination of fast recovery redundancy (<10 ms), comprehensive security protocols, and cross‑platform software support makes it ideal for industrial automation, SCADA, and remote monitoring systems. With a rugged metal enclosure, wide voltage range, and flexible mounting options, the IDS‑2011 delivers long‑term reliability and ease of integration into existing industrial networks.
Product Name: Serial 1×RS422/485 to Ethernet Device Server
Model: IDS‑2011
Series: IDS Industrial Device Server Series
Article Number: IDS‑2011
Manufacturer: SUNIX Co., Ltd. (Taiwan)
The SUNIX IDS‑2011 is a compact, industrial‑grade serial‑to‑Ethernet device server designed to connect legacy RS‑422/485 serial equipment to modern TCP/IP networks. It belongs to the SUNIX IDS series of Industrial Device Servers, which provide reliable, secure, and redundant networking for serial communication in industrial automation, data acquisition, and remote monitoring applications. The IDS‑2011 offers one RS‑422/485 serial port and one 10/100Base‑T(X) Ethernet port, supporting multiple communication modes and advanced management features for seamless integration into industrial Ethernet infrastructures.
2. Key Features
- Serial‑to‑Ethernet Conversion: Converts one RS‑422/485 serial interface into a standard 10/100Base‑T(X) Ethernet connection, enabling remote access and control of serial devices over IP networks.
- High Reliability: Supports Ethernet redundancy with recovery time under 10 ms, ensuring continuous communication in case of link failure.
- Multiple Operation Modes: Virtual COM, TCP Server, TCP Client, UDP, and Serial Tunnel modes for flexible deployment.
- Advanced Security: HTTPS, SSL, SSH, WEP/WPA/WPA2, 802.1X, Radius, and TKIP encryption for secure data transmission and management.
- Event Notification System: Real‑time alerts via Syslog, E‑mail, SNMP trap, relay output, and beeper for proactive fault management.
- Cross‑Platform Drivers: Virtual COM driver for Windows NT/2000/XP/2003/Vista and fixed TTY driver for Linux systems.
- Redundant Power Inputs: Dual 12–48 V DC inputs (terminal block and DC jack) with reverse polarity protection.
- Industrial‑Grade Design: Rugged metal enclosure (IP30 protection), 15 kV ESD protection, and 1.5 kV magnetic isolation on Ethernet port.
- Compact Form Factor: 72 × 31 × 125 mm (W × D × H) for space‑constrained installations.
- Flexible Mounting: DIN‑rail and wall‑mount options for versatile installation in control cabinets or equipment racks.
- Comprehensive Management Tools: IDS‑Tools Windows utility for device discovery, configuration, firmware updates, and monitoring.
- NAT Pass‑Through: Enables management through NAT routers, simplifying remote access across network boundaries.
- Up to Five Simultaneous Connections: Supports multiple concurrent sessions in Virtual COM, TCP Server, or Client modes.
- Long‑Term Reliability: 5‑year manufacturer warranty and industrial‑grade components for extended service life.
3. Technical Specifications
Serial Communication
- Port Type: 1 × RS‑422/485 (2‑wire or 4‑wire selectable)
- Connector: 5‑pin terminal block
- Baud Rate: 110 bps – 460.8 kbps
- Data Bits: 5, 6, 7, 8
- Parity: Odd, Even, None, Mark, Space
- Stop Bits: 1, 1.5, 2
- Flow Control: XON/XOFF, RTS/CTS, DTR/DSR
- RS‑422 Signals: TxD+, TxD−, RxD+, RxD−, GND
- RS‑485 (4‑wire): TxD+, TxD−, RxD+, RxD−, GND
- RS‑485 (2‑wire): Data+, Data−, GND
- ESD Protection: 15 kV
- Isolation: 1.5 kV magnetic isolation on Ethernet interface
Ethernet Interface
- Port: 1 × RJ‑45 10/100 Mbps (auto‑negotiation, Auto MDI/MDI‑X)
- Protocols Supported: ICMP, IP, TCP, UDP, DHCP, BootP, ARP/RARP, DNS, SNMP MIB II, HTTPS, SSL, SSH
- Operation Modes: Virtual COM, TCP Server, TCP Client, UDP, Serial Tunnel
- Redundancy: Ethernet redundancy with recovery < 10 ms
Power Requirements
- Input Voltage: 12 – 48 V DC (dual inputs: terminal block + DC jack)
- Power Consumption: Max 7 W
- Protection: Reverse polarity protection
Mechanical & Environmental
- Enclosure: Metal housing, IP30 protection
- Dimensions: 72 × 31 × 125 mm (W × D × H, without connectors)
- Mounting: DIN‑rail and wall‑mount options
- Weight: Approx. 0.4 kg (typical)
- Operating Temperature: −10 °C to 55 °C
- Storage Temperature: −20 °C to 85 °C
- Operating Humidity: 5 % – 95 % RH, non‑condensing
Certifications & Standards
- EMI: FCC Part 15, CISPR (EN55022) Class A
- EMS: EN61000‑4‑2 (ESD), EN61000‑4‑3 (RS), EN61000‑4‑4 (EFT), EN61000‑4‑5 (Surge Level 3), EN61000‑4‑6 (CS Level 3)
- Shock: IEC 60068‑2‑27
- Free Fall: IEC 60068‑2‑32
- Vibration: IEC 60068‑2‑6
- Compliance: CE Class A, RoHS
Warranty: 5 years
4. Functionality
The IDS‑2011 functions as a transparent bridge between serial and Ethernet networks. It encapsulates serial data into TCP/IP packets, allowing remote hosts to communicate with serial devices as if they were locally connected. The device supports multiple communication modes:
- Virtual COM Mode: Maps the serial port to a virtual COM port on a Windows host, enabling legacy applications to operate without modification.
- TCP Server Mode: Waits for incoming TCP connections from clients; supports up to five simultaneous connections.
- TCP Client Mode: Actively initiates a TCP connection to a designated server upon startup or data transmission.
- UDP Mode: Provides fast, connectionless data transfer for broadcast or multicast applications.
- Serial Tunnel Mode: Couples two IDS devices to create a serial‑over‑Ethernet tunnel, extending serial communication over long distances.
Use Cases & Applications:
- Industrial automation and PLC communication
- SCADA and remote monitoring systems
- Data acquisition and measurement equipment
- POS terminals and digital signage control
- Access control and card reader integration
- Medical instrumentation and laboratory systems
- Transportation and energy management networks
Compatibility:
- Operating Systems: Windows NT/2000/XP/2003/Vista (Virtual COM driver), Linux (TTY driver)
- Network Environments: Supports NAT pass‑through, DHCP, static IP, and DNS configurations.
- Management Interfaces: Web console (HTTPS), serial console, and IDS‑Tools Windows utility.
5. Components & Accessories
Included Items:
- IDS‑2011 Device Server unit
- Quick Installation Guide (QIG)
- DIN‑rail mount kit
- Wall‑mount kit
- Dust cover for connectors
- Software CD with IDS‑Tools utility and drivers
Optional Accessories:
- 12–48 V DC power adapter (sold separately)
- Additional DIN‑rail mounting brackets
- Terminal block connectors for custom wiring
Connectors:
- 5‑pin terminal block for RS‑422/485 serial port
- 3‑pin removable terminal block for power input
- DC jack for secondary power input
- RJ‑45 Ethernet port (10/100 Mbps)
6. Installation & Setup
Requirements:
- DC power supply (12–48 V DC, 7 W max)
- Standard CAT 5/5e Ethernet cable (up to 100 m)
- RS‑422/485 serial cable with 5‑pin terminal block connector
Mounting Options:
- DIN‑Rail Installation: Attach the included DIN‑rail clip to the rear panel and snap onto a standard 35 mm DIN rail.
- Wall Mounting: Remove the DIN‑rail kit and use the provided screws to secure the wall‑mount bracket.
Configuration Procedure:
1. Connect the power supply to PWR1 or PWR2 input.
2. Connect the Ethernet port to a LAN switch or router.
3. Connect the RS‑422/485 device to the serial port using the terminal block.
4. Install the IDS‑Tools utility on a Windows PC.
5. Discover the device (default IP 192.168.1.1) and assign a static or DHCP address.
6. Configure serial parameters (baud rate, data bits, parity, stop bits) and select the desired operation mode.
7. Save settings and reboot the device to apply changes.
Reset Function: Press and hold the reset button for 5 seconds to restore factory defaults.
7. Performance & Capabilities
- Ethernet Redundancy: Automatic failover within 10 ms ensures continuous operation in critical systems.
- Simultaneous Connections: Supports up to five concurrent TCP or Virtual COM sessions.
- Throughput: Optimized for high‑speed serial data transfer up to 460.8 kbps.
- Latency Optimization: Configurable for low‑latency or high‑throughput operation modes.
- Power Efficiency: Consumes less than 7 W under full load.
- Reliability: Dual power inputs and redundant Ethernet design minimize downtime.
- Limitations: Single serial port model — for multi‑port applications, SUNIX offers IDS‑3012 and IDS‑3042 variants.
8. Standards & Compliance
The IDS‑2011 meets international industrial and electromagnetic compatibility standards for safe and reliable operation in harsh environments.
- EMI Compliance: FCC Part 15 Class A, CISPR (EN55022) Class A
- EMS Immunity: EN61000‑4‑2 (ESD), EN61000‑4‑3 (RS), EN61000‑4‑4 (EFT), EN61000‑4‑5 (Surge Level 3), EN61000‑4‑6 (CS Level 3)
- Environmental Testing: IEC 60068‑2‑27 (Shock), IEC 60068‑2‑32 (Free Fall), IEC 60068‑2‑6 (Vibration)
- Safety & Reliability: IP30 metal enclosure for industrial protection, RoHS compliant materials.
- Network Security Standards: Supports HTTPS (SSL), SSH, 802.1X authentication, and Radius integration for secure management.
9. Additional Information
Warranty & Support:
- 5‑year limited hardware warranty from SUNIX Co., Ltd.
- Technical support available via email (info@sunix.com.tw) and official website (www.sunix.com.tw).
- Firmware and driver updates provided through the SUNIX support portal.
Maintenance:
- Periodically check terminal connections and clean ventilation openings.
- Use IDS‑Tools for firmware updates and configuration backups.
- Maintain redundant power and network connections for maximum uptime.
Software Updates & Utilities:
- IDS‑Tools Utility: Provides device discovery, group configuration, firmware upgrade, and monitoring functions.
- Web Management Interface: Accessible via HTTPS for configuration and status monitoring.
- SSH Console: Secure command‑line access for advanced users.
Manufacturer Contact:
SUNIX Co., Ltd.
Tel: +886‑2‑8913‑1987 Fax: +886‑2‑8913‑1986
Email: info@sunix.com.tw Website: [www.sunix.com.tw](http://www.sunix.com.tw)
### Summary
The SUNIX IDS‑2011 is a robust, industrial‑grade 1‑port RS‑422/485 to Ethernet device server engineered for mission‑critical applications requiring secure, redundant, and high‑performance serial communication over IP networks. Its combination of fast recovery redundancy (<10 ms), comprehensive security protocols, and cross‑platform software support makes it ideal for industrial automation, SCADA, and remote monitoring systems. With a rugged metal enclosure, wide voltage range, and flexible mounting options, the IDS‑2011 delivers long‑term reliability and ease of integration into existing industrial networks.
-
IndustrialDeviceServers.pdf
PDF Catalog
-
IDS-3012.pdf
Manual
-
IDS_quick_start.pdf
Manual
Kein Zubehör vorhanden.