IDS-5011F-SS

Industrial Device Server 1*RS232/422/485 to 1*100FX SS Slim
  • Hersteller Oring
  • Kategorie: Industrial Device Server
  • The ORing IDS-5011F-SS is a rugged, industrial-grade single-port serial-to-fiber device server designed to connect RS-232/422/485 serial devices to a 100Base-FX single-mode fiber Ethernet network. It provides secure, redundant, and high-performance serial-to-Ethernet communication for mission-critical industrial applications. The device is part of ORing’s IDS-5011F series, which includes both multi-mode (IDS-5011F-MM) and single-mode (IDS-5011F-SS) variants.
- 1-Port Serial to 1-Port Fiber Ethernet Conversion: Supports RS-232, RS-422, and 2/4-wire RS-485 interfaces via a DB9 male connector, converting serial data to 100Base-FX single-mode fiber Ethernet.
- High Security: HTTPS, SSH, and SSL encryption ensure secure data transmission and management.
- Redundant Host Support: Simultaneous data transfer to up to five host PCs in Virtual COM, TCP Server, TCP Client, or UDP modes for enhanced reliability.
- Dual Redundant Power Inputs: Accepts 12–48 VDC via both a terminal block and a DC power jack, ensuring uninterrupted operation.
- NAT Pass-Through: Enables remote management through NAT routers, supporting DDNS and PPPoE for flexible deployment across IP domains.
- Event Notification System: Alerts via Syslog, Email, SNMP trap, relay, or beeper for system events and faults.
- Industrial-Grade Design: IP-30 metal enclosure, DIN-rail and wall-mount options, and wide operating temperature range (-40°C to 70°C).
- Fast Ethernet Redundancy: Ethernet recovery time under 10 ms for high-availability networks.
- Comprehensive Management Tools: Configurable via web browser, SSH console, or Windows utility (DS-Tool).
- Fixed TTY Driver for Linux: Ensures compatibility with Linux-based systems.
- Wide OS Support: Compatible with Windows NT, 2000, XP, 2003, and Vista (32-bit).

Ursprungsland: Taiwan R.O.C.

Zolltarifnummer: 8517 6200 900

Comprehensive Product Summary – IDS-5011F-SS Industrial Device Server




### 1. Product Overview

Product Name: Industrial Device Server
Model: IDS-5011F-SS
Series: IDS-5011F Series
Article Number: IDS-5011F-SS
Manufacturer: ORing Industrial Networking Corp.
Manufacturer Address: 4F., No.3, Lane 235, Baociao Rd., Sindian City, Taipei County 23145, Taiwan, R.O.C.
Website: [www.oring-networking.com](http://www.oring-networking.com)
Support Email: support@oring-networking.com

The ORing IDS-5011F-SS is a rugged, industrial-grade single-port serial-to-fiber device server designed to connect RS-232/422/485 serial devices to a 100Base-FX single-mode fiber Ethernet network. It provides secure, redundant, and high-performance serial-to-Ethernet communication for mission-critical industrial applications. The device is part of ORing’s IDS-5011F series, which includes both multi-mode (IDS-5011F-MM) and single-mode (IDS-5011F-SS) variants.




### 2. Key Features

- 1-Port Serial to 1-Port Fiber Ethernet Conversion: Supports RS-232, RS-422, and 2/4-wire RS-485 interfaces via a DB9 male connector, converting serial data to 100Base-FX single-mode fiber Ethernet.
- High Security: HTTPS, SSH, and SSL encryption ensure secure data transmission and management.
- Redundant Host Support: Simultaneous data transfer to up to five host PCs in Virtual COM, TCP Server, TCP Client, or UDP modes for enhanced reliability.
- Dual Redundant Power Inputs: Accepts 12–48 VDC via both a terminal block and a DC power jack, ensuring uninterrupted operation.
- NAT Pass-Through: Enables remote management through NAT routers, supporting DDNS and PPPoE for flexible deployment across IP domains.
- Event Notification System: Alerts via Syslog, Email, SNMP trap, relay, or beeper for system events and faults.
- Industrial-Grade Design: IP-30 metal enclosure, DIN-rail and wall-mount options, and wide operating temperature range (-40°C to 70°C).
- Fast Ethernet Redundancy: Ethernet recovery time under 10 ms for high-availability networks.
- Comprehensive Management Tools: Configurable via web browser, SSH console, or Windows utility (DS-Tool).
- Fixed TTY Driver for Linux: Ensures compatibility with Linux-based systems.
- Wide OS Support: Compatible with Windows NT, 2000, XP, 2003, and Vista (32-bit).




### 3. Technical Specifications

Network Interface:
- 1 × 100Base-FX single-mode fiber port (SC connector)
- Fiber Type: 9/125 µm single-mode
- Wavelength: 1310 nm
- Typical Distance: 30 km
- Optical Power Output: Max -8 dBm, Min -15 dBm
- Optical Power Sensitivity: Min -34 dBm
- Link Budget: 19 dB

Serial Interface:
- 1 × RS-232/422/485 port (DB9 male)
- Configurable via DS-Tool or web interface
- Baud Rate: 110 bps to 460.8 Kbps
- Data Bits: 5, 6, 7, 8
- Parity: Odd, Even, None, Mark, Space
- Stop Bits: 1, 1.5, 2
- Flow Control: XON/XOFF, RTS/CTS, DTR/DSR
- RS-232 Signals: TxD, RxD, RTS, CTS, DTR, DSR, DCD, RI, GND
- RS-422 Signals: Tx+, Tx-, Rx+, Rx-, GND
- RS-485 (4-wire): Tx+, Tx-, Rx+, Rx-, GND
- RS-485 (2-wire): Data+, Data-, GND
- Built-in 15 kV ESD protection

Power:
- Dual DC Inputs: 12–48 VDC (3-pin terminal block and DC jack)
- Power Consumption: 4 W (typical)
- Reverse Polarity Protection: Present on terminal block
- Overload Current Protection: Present

Physical Characteristics:
- Dimensions: 72(W) × 29.4(D) × 123.4(H) mm (2.83 × 1.16 × 4.86 in)
- Weight: 325 g
- Enclosure: IP-30 rated metal housing
- Mounting: DIN-rail and wall-mount options

Environmental:
- Operating Temperature: -40°C to 70°C (-40°F to 158°F)
- Storage Temperature: -40°C to 85°C (-40°F to 185°F)
- Humidity: 5%–95% non-condensing

LED Indicators:
- PWR1/PWR2: Green (normal), Red (booting/IP conflict)
- Fiber Link/Act: Green for 100 Mbps link/activity
- Serial TX/RX: Green (transmit), Red (receive)




### 4. Functionality

The IDS-5011F-SS functions as a secure, high-performance bridge between serial devices and Ethernet networks. It supports multiple communication modes:

- Virtual COM Mode: Maps the serial port to a virtual COM port on a host PC, allowing legacy applications to communicate over Ethernet transparently. Supports up to five simultaneous host connections.
- TCP Server Mode: Waits for incoming TCP connections from clients; supports up to five concurrent connections.
- TCP Client Mode: Initiates TCP connections to a designated server upon startup or data transmission.
- UDP Mode: Enables fast, connectionless data transmission for multicast or unicast communication.
- Serial Tunnel Mode: Creates a transparent serial link between two IDS-5011F devices over Ethernet.

Use Cases:
- Industrial automation and SCADA systems
- Remote monitoring of PLCs, sensors, and controllers
- Transportation and energy management systems
- Secure data acquisition in harsh environments
- Integration of legacy serial devices into modern Ethernet networks

Compatibility:
- Operating Systems: Windows NT/2000/XP/2003/Vista (32-bit)
- Linux (via fixed TTY driver)
- Network Protocols: ICMP, IP, TCP, UDP, DHCP, BOOTP, ARP/RARP, DNS, SNMP v1/v2c, HTTPS, SSH, SMTP, SSL, PPPoE, DDNS




### 5. Components & Accessories

Included Items:
- IDS-5011F-SS device server
- DIN-rail mounting kit
- Wall-mount kit
- ORing Tool CD (includes DS-Tool software)
- Quick Installation Guide

Optional Accessories:
- Power Supplies:
- DR-45 series (45 W DIN-rail power supply)
- DR-75 series (75 W DIN-rail power supply)
- DR-120 series (120 W DIN-rail power supply)
- PAA-121000 (12 VDC/1000 mA, US plug)
- PAE-121000 (12 VDC/1000 mA, EU plug)

Connectors:
- Fiber: SC connector (single-mode)
- Serial: DB9 male connector
- Power: 3-pin terminal block and DC jack




### 6. Installation & Setup

Mounting Options:
- DIN-Rail Installation:
Each unit includes a pre-installed DIN-rail clip. To mount, align the spring clip with the rail, press until a “click” is heard.
- Wall Mounting:
Remove the DIN-rail clip, attach the wall-mount bracket using six screws, and secure the unit to the wall.

Power Connection:
- Connect 12–48 VDC to either the terminal block or DC jack. Both inputs can be used simultaneously for redundancy.

Fiber Connection:
- Connect the TX port of the IDS-5011F-SS to the RX port of the switch (and vice versa) using single-mode fiber (9/125 µm).

Serial Connection:
- Use the DB9 male connector for RS-232/422/485 communication. DIP switches configure termination for long-distance RS-422/485 lines.

Configuration:
- Web Interface: Access via HTTPS at default IP 192.168.10.2.
- DS-Tool Utility: Windows-based software for device discovery, configuration, firmware updates, and monitoring.
- SSH Console: Secure command-line configuration using SSH tools (e.g., PuTTY).

Default Settings:
- IP Address: 192.168.10.2
- No default password (user-defined during setup)




### 7. Performance & Capabilities

- Data Rate: Up to 460.8 Kbps on serial interface
- Network Speed: 100 Mbps (fiber)
- Redundancy: Supports up to five simultaneous host connections for data backup and failover
- Ethernet Recovery Time: <10 ms
- Power Efficiency: Typical consumption 4 W
- Reliability: MTBF > 560,000 hours (MIL-HDBK-217F2, 25°C)
- Event Notification: Configurable alerts for power failure, link loss, unauthorized access, and serial signal changes (DCD, DSR, RI, CTS)
- Security: HTTPS, SSH, SSL encryption; IP access control; password protection
- Data Handling: Configurable delimiters, buffer flush intervals, and force TX intervals for optimized throughput or latency

Limitations:
- Single serial port (1x RS-232/422/485)
- Single Ethernet fiber port (no copper port)
- Requires external power supply (not included)




### 8. Standards & Compliance

EMI/EMS Compliance:
- FCC Part 15, CISPR (EN55022) Class A
- EN61000-4-2 (ESD)
- EN61000-4-3 (Radiated Susceptibility)
- EN61000-4-4 (EFT)
- EN61000-4-5 (Surge)
- EN61000-4-6 (Conducted Susceptibility)
- EN61000-4-8 (Magnetic Field)
- EN61000-4-11 (Voltage Dips/Interruptions)

Environmental & Safety:
- Shock: IEC 60068-2-27
- Vibration: IEC 60068-2-6
- Free Fall: IEC 60068-2-32
- Safety: EN60950-1

Ingress Protection:
- IP-30 rated metal enclosure

Certifications:
- CE, FCC, RoHS compliant




### 9. Additional Information

Warranty:
5-year limited warranty covering manufacturing defects and hardware failures under normal operating conditions.

Support & Maintenance:
- Firmware updates available via DS-Tool or web interface
- Technical support via ORing’s global service network
- Configuration backup and restore functions for easy maintenance
- Event logging and SNMP monitoring for proactive system management

Software Utility (DS-Tool):
- Device discovery and configuration
- Group firmware updates
- Serial port monitoring
- Event notification setup
- Access control and IP filtering
- Real-time device status reporting

Firmware Management:
- Upgradeable via web interface or DS-Tool
- Supports configuration export/import for backup and replication

Mean Time Between Failures (MTBF):
- IDS-5011F-MM: 561,145 hours
- IDS-5011F-SS: 562,542 hours

Ordering Information:
- IDS-5011F-MM-SC: Multi-mode fiber, 2 km, 1310 nm, SC connector
- IDS-5011F-SS-SC: Single-mode fiber, 30 km, 1310 nm, SC connector




### Summary

The ORing IDS-5011F-SS is a robust, secure, and high-performance industrial device server engineered for reliable serial-to-fiber Ethernet communication in demanding environments. Its combination of redundant power inputs, multi-host connectivity, and advanced security protocols makes it ideal for mission-critical applications such as industrial automation, transportation, and energy systems. With flexible configuration options, comprehensive management tools, and compliance with international standards, the IDS-5011F-SS delivers exceptional reliability, security, and performance for modern industrial networking infrastructures.

Kein Zubehör vorhanden.