- High-Speed Sampling: 100 MS/s maximum sample rate for accurate waveform reproduction.
- High Resolution: 14-bit vertical resolution for fine amplitude granularity and low distortion.
- Large Memory Depth: 1 M-point standard waveform memory, expandable to 2 M points.
- Advanced Sequencing: Supports up to 4096 sequence steps and 128k segment loops for complex waveform generation.
- Multi-Instrument Synchronization: Enables synchronization of up to six PXI instruments with <15 ns skew.
- Flexible Modulation Modes: FM, FSK, ramped FSK, and sweep modes with internal or external control.
- Low Phase Noise: Stable, low-jitter clock source with optional 1 ppm TCXO reference.
- Internal Trigger Generation: Built-in trigger sources for autonomous operation.
- Comprehensive Waveform Library: Includes standard waveforms such as sine, square, triangle, pulse, ramp, sinc, Gaussian, exponential, noise, and DC.
- PXI Integration: Fully compatible with PXI backplane timing and triggering resources.
- Software Compatibility: Supports Windows 2000/XP/Vista/2003 and ARBDetector software for waveform management.
- High Resolution: 14-bit vertical resolution for fine amplitude granularity and low distortion.
- Large Memory Depth: 1 M-point standard waveform memory, expandable to 2 M points.
- Advanced Sequencing: Supports up to 4096 sequence steps and 128k segment loops for complex waveform generation.
- Multi-Instrument Synchronization: Enables synchronization of up to six PXI instruments with <15 ns skew.
- Flexible Modulation Modes: FM, FSK, ramped FSK, and sweep modes with internal or external control.
- Low Phase Noise: Stable, low-jitter clock source with optional 1 ppm TCXO reference.
- Internal Trigger Generation: Built-in trigger sources for autonomous operation.
- Comprehensive Waveform Library: Includes standard waveforms such as sine, square, triangle, pulse, ramp, sinc, Gaussian, exponential, noise, and DC.
- PXI Integration: Fully compatible with PXI backplane timing and triggering resources.
- Software Compatibility: Supports Windows 2000/XP/Vista/2003 and ARBDetector software for waveform management.
1. Product Overview
Product Name: TE-5201
Model: TE-5201
Series: PXI Arbitrary Waveform Generator Series
Article Number: TE-5201
Manufacturer: ADLINK Technology, Inc.
The ADLINK TE-5201 is a high-performance, single-channel PXI arbitrary waveform generator (AWG) designed for precision signal generation in automated test and measurement systems. Built on a 3U PXI form factor, the TE-5201 delivers a maximum sampling rate of 100 mega-samples per second (MS/s) with 14-bit vertical resolution and up to 2 mega-samples (MS) of waveform memory. It supports advanced sequencing, modulation, and synchronization capabilities, making it suitable for complex waveform synthesis, multi-instrument synchronization, and high-speed signal generation applications.
2. Key Features
- High-Speed Sampling: 100 MS/s maximum sample rate for accurate waveform reproduction.
- High Resolution: 14-bit vertical resolution for fine amplitude granularity and low distortion.
- Large Memory Depth: 1 M-point standard waveform memory, expandable to 2 M points.
- Advanced Sequencing: Supports up to 4096 sequence steps and 128k segment loops for complex waveform generation.
- Multi-Instrument Synchronization: Enables synchronization of up to six PXI instruments with <15 ns skew.
- Flexible Modulation Modes: FM, FSK, ramped FSK, and sweep modes with internal or external control.
- Low Phase Noise: Stable, low-jitter clock source with optional 1 ppm TCXO reference.
- Internal Trigger Generation: Built-in trigger sources for autonomous operation.
- Comprehensive Waveform Library: Includes standard waveforms such as sine, square, triangle, pulse, ramp, sinc, Gaussian, exponential, noise, and DC.
- PXI Integration: Fully compatible with PXI backplane timing and triggering resources.
- Software Compatibility: Supports Windows 2000/XP/Vista/2003 and ARBDetector software for waveform management.
3. Technical Specifications
Form Factor: PXI 3U module
Number of Channels: 1
Sampling Rate: 50 S/s to 100 MS/s
Vertical Resolution: 14 bits (16,384 levels)
Waveform Memory: 1 M points standard, 2 M points optional
Memory Segmentation: 1 to 64K segments (128K with 2 M-point option)
Minimum Segment Size: 16 points
Memory Interleave: 4 (trace lengths must be multiples of 4)
Sequence Steps: 1 to 4096
Segment Loops: 1 to 128k
Amplitude Range:
- 80 mVpp to 8 Vpp into 50 Ω load
- 160 mVpp to 16 Vpp open circuit
Amplitude Resolution: 3.5 digits
Amplitude Accuracy (1 kHz):
- ±(1% + 25 mV) for 1.000 V to 10 Vpp
- ±(1% + 5 mV) for 80 mV to 999.9 mVpp
Offset Voltage:
- Range: 0 to ±3.6 V (amplitude dependent)
- Resolution: 22 mV
- Accuracy: ±(1% of reading + 1% of amplitude + 2 mV) within ±4 V window
Output Impedance: 50 Ω ±1%
Output Protection: Short-circuit protection to chassis ground
Filters: 25 MHz and 50 MHz, 7-pole elliptic filters
Rise/Fall Time (Square/Pulse): <10 ns (10–90%)
Aberration: <5%
Physical Dimensions: PXI 3U standard module (approx. 160 mm × 100 mm × 20 mm typical)
Weight: Approx. 0.6–0.8 kg (typical for PXI 3U module)
Material: Aluminum chassis with front-panel BNC/SMB connectors
4. Functionality
The TE-5201 operates as a precision arbitrary waveform generator capable of producing both standard and user-defined waveforms. It uses a high-speed digital-to-analog converter (DAC) to reconstruct analog signals from stored digital data. The internal clock or external reference drives the sampling process, ensuring precise timing and frequency control.
Use Cases and Applications:
- Automated test systems for electronic component validation
- Communication system simulation and modulation testing
- Sensor and transducer signal emulation
- Mixed-signal and RF test environments
- Education and research laboratories requiring flexible waveform synthesis
Compatibility:
- PXI and CompactPCI systems
- Windows-based control environments
- SCPI command interface for remote programming
- Synchronization with other PXI instruments via backplane triggers and clock lines
5. Components & Accessories
Included Items:
- TE-5201 PXI Arbitrary Waveform Generator module
- User documentation and software drivers
- Front-panel connectors:
- BNC for waveform output, trigger input, and SYNC/marker output
- SMB for sine output and 10 MHz reference input
Optional Accessories:
- 2 M-point memory upgrade
- 1 ppm TCXO precision clock option
- PXI chassis and controller (sold separately)
- ARBDetector waveform editing software
Connectors:
- Waveform Output: BNC, 50 Ω
- SYNC/Marker Output: BNC, 50 Ω
- Trigger Input: BNC, 10 kΩ
- Sine Output: SMB, 50 Ω
- 10 MHz Reference Input: SMB, 10 kΩ
6. Installation & Setup
Requirements:
- PXI or CompactPCI chassis with available 3U slot
- Compatible PXI controller or host PC with driver support
- Operating system: Windows 2000, XP, Vista, or 2003
Mounting Options:
- Standard PXI 3U slot installation
- Front-panel BNC/SMB connectors accessible for signal routing
Configuration:
- Software-controlled setup via SCPI commands or ARBDetector software
- Internal or external clock selection
- Trigger configuration (internal, external, or software)
- Synchronization setup for multi-instrument operation via PXI backplane
Synchronization Setup:
- Master-slave configuration through PXI local bus
- Initial skew <15 ns to first slave, cumulative 15 ns per additional slave
- External 10 MHz TTL reference input for system-wide synchronization
7. Performance & Capabilities
Sampling Clock:
- Internal Range: 50 S/s to 100 MS/s
- Resolution: 10 digits (1 µHz minimum step)
- Accuracy: Same as reference clock
- Stability: Same as reference clock
- Optional TCXO: 1 ppm initial tolerance (19–29°C), 1 ppm/°C drift, 1 ppm/year aging
External Reference: 10 MHz TTL, 50% ±2% duty cycle
Modulation Capabilities:
- FM (Fixed Waveforms):
- Internal modulation sources: sine, square, triangle, ramp
- Frequency range: 2 mHz to 100 kHz
- Peak deviation: DC to 50 MHz
- Resolution: 10 digits, accuracy 0.1%
- FM (User-Defined Waveforms):
- User waveform length: 10–20,000 points
- Peak deviation: DC to 100 MHz
- Download rate: 5 M points/s
- FSK:
- Frequency range: DC to 10 MHz
- Delay: 1 waveform cycle + 50 ns
- Ramped FSK:
- Ramp time: 10 µs to 1 s, ±0.1%
- Sweep:
- Range: 50 mS/s to 100 MS/s
- Sweep time: 1 ms to 1000 s
- Linear or logarithmic, up/down direction
Operating Modes:
- Normal (continuous)
- Triggered (single-cycle per trigger)
- Gated (output enabled by external signal)
- External Burst (up to 128k cycles per trigger)
Trigger Sources:
- External (BNC, TTL, 5 MHz–DC)
- Internal (100 mHz–2 MHz, 7-digit resolution)
- PXI backplane (TTL Trig0–Trig7, STAR)
- Software (SCPI command)
System Delay: Trigger to output = 1 sample clock + 120 ns
Waveform Performance:
- THD (sine wave): 0.3% up to 1 MHz
- Spurious-free dynamic range (SFDR):
- <–55 dBc below 1 MHz
- <–40 dBc below 5 MHz
- <–25 dBc below 25 MHz
Sine Output Performance:
- Frequency range: same as sample clock
- Flatness: –3 dB at 100 MHz
- THD: <40 dBc to 1 MHz
- Spurious: <50 dBc to 10 MHz, <38 dBc to 100 MHz
8. Standards & Compliance
- PXI Compliance: Fully compliant with PXI 3U mechanical and electrical standards
- Electrical Safety: Designed to meet IEC and CE safety requirements for laboratory instrumentation
- EMC Compliance: Conforms to industrial electromagnetic compatibility standards
- Environmental:
- Operating temperature: 0°C to 50°C
- Storage temperature: –20°C to 70°C
- Humidity: 10–90% non-condensing
- Clock Accuracy Options:
- Standard: 100 ppm (0.01%)
- Optional TCXO: 1 ppm (0.0001%)
9. Additional Information
Warranty: Standard manufacturer’s warranty (typically 1 year, extendable)
Support:
- Technical documentation and driver downloads available at [www.adlinktech.com](http://www.adlinktech.com)
- Software support for ARBDetector and SCPI command interface
- Firmware updates and calibration services available through ADLINK service centers
Maintenance:
- Periodic calibration recommended for optimal accuracy
- Clean front-panel connectors with appropriate electronic-grade solvents
- Verify clock synchronization and reference integrity during system integration
Software & Updates:
- ARBDetector software for waveform creation, editing, and download
- SCPI command set for automation and remote control
- Compatible with major PXI system controllers and test automation frameworks
Ordering Information:
- TE-5201: PXI 100 MS/s Arbitrary Waveform Generator
- Options:
- 2 M-point memory upgrade
- 1 ppm TCXO precision clock option
Summary
The ADLINK TE-5201 PXI 100 MS/s Arbitrary Waveform Generator is a robust, high-resolution signal source tailored for advanced test and measurement applications. Its combination of 14-bit resolution, deep waveform memory, and flexible modulation capabilities enables precise generation of complex analog signals. With built-in sequencing, synchronization, and modulation features, the TE-5201 integrates seamlessly into PXI-based automated test systems, supporting synchronized multi-channel operation and high-speed waveform updates. Its low phase noise, high accuracy, and extensive waveform control make it ideal for research, development, and production testing environments requiring reliable and repeatable signal generation.
Product Name: TE-5201
Model: TE-5201
Series: PXI Arbitrary Waveform Generator Series
Article Number: TE-5201
Manufacturer: ADLINK Technology, Inc.
The ADLINK TE-5201 is a high-performance, single-channel PXI arbitrary waveform generator (AWG) designed for precision signal generation in automated test and measurement systems. Built on a 3U PXI form factor, the TE-5201 delivers a maximum sampling rate of 100 mega-samples per second (MS/s) with 14-bit vertical resolution and up to 2 mega-samples (MS) of waveform memory. It supports advanced sequencing, modulation, and synchronization capabilities, making it suitable for complex waveform synthesis, multi-instrument synchronization, and high-speed signal generation applications.
2. Key Features
- High-Speed Sampling: 100 MS/s maximum sample rate for accurate waveform reproduction.
- High Resolution: 14-bit vertical resolution for fine amplitude granularity and low distortion.
- Large Memory Depth: 1 M-point standard waveform memory, expandable to 2 M points.
- Advanced Sequencing: Supports up to 4096 sequence steps and 128k segment loops for complex waveform generation.
- Multi-Instrument Synchronization: Enables synchronization of up to six PXI instruments with <15 ns skew.
- Flexible Modulation Modes: FM, FSK, ramped FSK, and sweep modes with internal or external control.
- Low Phase Noise: Stable, low-jitter clock source with optional 1 ppm TCXO reference.
- Internal Trigger Generation: Built-in trigger sources for autonomous operation.
- Comprehensive Waveform Library: Includes standard waveforms such as sine, square, triangle, pulse, ramp, sinc, Gaussian, exponential, noise, and DC.
- PXI Integration: Fully compatible with PXI backplane timing and triggering resources.
- Software Compatibility: Supports Windows 2000/XP/Vista/2003 and ARBDetector software for waveform management.
3. Technical Specifications
Form Factor: PXI 3U module
Number of Channels: 1
Sampling Rate: 50 S/s to 100 MS/s
Vertical Resolution: 14 bits (16,384 levels)
Waveform Memory: 1 M points standard, 2 M points optional
Memory Segmentation: 1 to 64K segments (128K with 2 M-point option)
Minimum Segment Size: 16 points
Memory Interleave: 4 (trace lengths must be multiples of 4)
Sequence Steps: 1 to 4096
Segment Loops: 1 to 128k
Amplitude Range:
- 80 mVpp to 8 Vpp into 50 Ω load
- 160 mVpp to 16 Vpp open circuit
Amplitude Resolution: 3.5 digits
Amplitude Accuracy (1 kHz):
- ±(1% + 25 mV) for 1.000 V to 10 Vpp
- ±(1% + 5 mV) for 80 mV to 999.9 mVpp
Offset Voltage:
- Range: 0 to ±3.6 V (amplitude dependent)
- Resolution: 22 mV
- Accuracy: ±(1% of reading + 1% of amplitude + 2 mV) within ±4 V window
Output Impedance: 50 Ω ±1%
Output Protection: Short-circuit protection to chassis ground
Filters: 25 MHz and 50 MHz, 7-pole elliptic filters
Rise/Fall Time (Square/Pulse): <10 ns (10–90%)
Aberration: <5%
Physical Dimensions: PXI 3U standard module (approx. 160 mm × 100 mm × 20 mm typical)
Weight: Approx. 0.6–0.8 kg (typical for PXI 3U module)
Material: Aluminum chassis with front-panel BNC/SMB connectors
4. Functionality
The TE-5201 operates as a precision arbitrary waveform generator capable of producing both standard and user-defined waveforms. It uses a high-speed digital-to-analog converter (DAC) to reconstruct analog signals from stored digital data. The internal clock or external reference drives the sampling process, ensuring precise timing and frequency control.
Use Cases and Applications:
- Automated test systems for electronic component validation
- Communication system simulation and modulation testing
- Sensor and transducer signal emulation
- Mixed-signal and RF test environments
- Education and research laboratories requiring flexible waveform synthesis
Compatibility:
- PXI and CompactPCI systems
- Windows-based control environments
- SCPI command interface for remote programming
- Synchronization with other PXI instruments via backplane triggers and clock lines
5. Components & Accessories
Included Items:
- TE-5201 PXI Arbitrary Waveform Generator module
- User documentation and software drivers
- Front-panel connectors:
- BNC for waveform output, trigger input, and SYNC/marker output
- SMB for sine output and 10 MHz reference input
Optional Accessories:
- 2 M-point memory upgrade
- 1 ppm TCXO precision clock option
- PXI chassis and controller (sold separately)
- ARBDetector waveform editing software
Connectors:
- Waveform Output: BNC, 50 Ω
- SYNC/Marker Output: BNC, 50 Ω
- Trigger Input: BNC, 10 kΩ
- Sine Output: SMB, 50 Ω
- 10 MHz Reference Input: SMB, 10 kΩ
6. Installation & Setup
Requirements:
- PXI or CompactPCI chassis with available 3U slot
- Compatible PXI controller or host PC with driver support
- Operating system: Windows 2000, XP, Vista, or 2003
Mounting Options:
- Standard PXI 3U slot installation
- Front-panel BNC/SMB connectors accessible for signal routing
Configuration:
- Software-controlled setup via SCPI commands or ARBDetector software
- Internal or external clock selection
- Trigger configuration (internal, external, or software)
- Synchronization setup for multi-instrument operation via PXI backplane
Synchronization Setup:
- Master-slave configuration through PXI local bus
- Initial skew <15 ns to first slave, cumulative 15 ns per additional slave
- External 10 MHz TTL reference input for system-wide synchronization
7. Performance & Capabilities
Sampling Clock:
- Internal Range: 50 S/s to 100 MS/s
- Resolution: 10 digits (1 µHz minimum step)
- Accuracy: Same as reference clock
- Stability: Same as reference clock
- Optional TCXO: 1 ppm initial tolerance (19–29°C), 1 ppm/°C drift, 1 ppm/year aging
External Reference: 10 MHz TTL, 50% ±2% duty cycle
Modulation Capabilities:
- FM (Fixed Waveforms):
- Internal modulation sources: sine, square, triangle, ramp
- Frequency range: 2 mHz to 100 kHz
- Peak deviation: DC to 50 MHz
- Resolution: 10 digits, accuracy 0.1%
- FM (User-Defined Waveforms):
- User waveform length: 10–20,000 points
- Peak deviation: DC to 100 MHz
- Download rate: 5 M points/s
- FSK:
- Frequency range: DC to 10 MHz
- Delay: 1 waveform cycle + 50 ns
- Ramped FSK:
- Ramp time: 10 µs to 1 s, ±0.1%
- Sweep:
- Range: 50 mS/s to 100 MS/s
- Sweep time: 1 ms to 1000 s
- Linear or logarithmic, up/down direction
Operating Modes:
- Normal (continuous)
- Triggered (single-cycle per trigger)
- Gated (output enabled by external signal)
- External Burst (up to 128k cycles per trigger)
Trigger Sources:
- External (BNC, TTL, 5 MHz–DC)
- Internal (100 mHz–2 MHz, 7-digit resolution)
- PXI backplane (TTL Trig0–Trig7, STAR)
- Software (SCPI command)
System Delay: Trigger to output = 1 sample clock + 120 ns
Waveform Performance:
- THD (sine wave): 0.3% up to 1 MHz
- Spurious-free dynamic range (SFDR):
- <–55 dBc below 1 MHz
- <–40 dBc below 5 MHz
- <–25 dBc below 25 MHz
Sine Output Performance:
- Frequency range: same as sample clock
- Flatness: –3 dB at 100 MHz
- THD: <40 dBc to 1 MHz
- Spurious: <50 dBc to 10 MHz, <38 dBc to 100 MHz
8. Standards & Compliance
- PXI Compliance: Fully compliant with PXI 3U mechanical and electrical standards
- Electrical Safety: Designed to meet IEC and CE safety requirements for laboratory instrumentation
- EMC Compliance: Conforms to industrial electromagnetic compatibility standards
- Environmental:
- Operating temperature: 0°C to 50°C
- Storage temperature: –20°C to 70°C
- Humidity: 10–90% non-condensing
- Clock Accuracy Options:
- Standard: 100 ppm (0.01%)
- Optional TCXO: 1 ppm (0.0001%)
9. Additional Information
Warranty: Standard manufacturer’s warranty (typically 1 year, extendable)
Support:
- Technical documentation and driver downloads available at [www.adlinktech.com](http://www.adlinktech.com)
- Software support for ARBDetector and SCPI command interface
- Firmware updates and calibration services available through ADLINK service centers
Maintenance:
- Periodic calibration recommended for optimal accuracy
- Clean front-panel connectors with appropriate electronic-grade solvents
- Verify clock synchronization and reference integrity during system integration
Software & Updates:
- ARBDetector software for waveform creation, editing, and download
- SCPI command set for automation and remote control
- Compatible with major PXI system controllers and test automation frameworks
Ordering Information:
- TE-5201: PXI 100 MS/s Arbitrary Waveform Generator
- Options:
- 2 M-point memory upgrade
- 1 ppm TCXO precision clock option
Summary
The ADLINK TE-5201 PXI 100 MS/s Arbitrary Waveform Generator is a robust, high-resolution signal source tailored for advanced test and measurement applications. Its combination of 14-bit resolution, deep waveform memory, and flexible modulation capabilities enables precise generation of complex analog signals. With built-in sequencing, synchronization, and modulation features, the TE-5201 integrates seamlessly into PXI-based automated test systems, supporting synchronized multi-channel operation and high-speed waveform updates. Its low phase noise, high accuracy, and extensive waveform control make it ideal for research, development, and production testing environments requiring reliable and repeatable signal generation.
-
TE-5201_Datasheet_en_1.pdf
PDF Catalog
-
TE-5201_Datasheet_5.pdf
PDF Catalog
Kein Zubehör vorhanden.