4.4.1.2.2 1*DA 12-bit analog out RS485 Module EX9021
1*DA 12-bit analog out RS485 Module

- **Single Analog Output Channel:** Provides one analog output channel configurable for voltage or current output modes. - **12-bit Resolution:** Ensures fine output granularity and high signal accuracy for industrial control applications. - **Output Range Flexibility:** Supports voltage output from 0–10 VDC and current output ranges of 0–20 mA or 4–20 mA. - **RS485 Communication Interface:** Fully compatible with standard RS485 networks, enabling multi-drop communication and long-distance data transmission. - **Wide Operating Temperature Range:** Designed for reliable operation in extended industrial temperature environments. - **Dual Watchdog Timer (WDT):** Provides system reliability by monitoring both host and module operation, ensuring safe fallback states in case of communication failure. - **Selectable Power Source:** Internal power (default) supports up to 500 Ω load; external 24 V power option supports up to 1050 Ω load. - **Programmable Slew Rate Control:** Allows smooth, controlled output transitions to prevent abrupt signal changes that could affect sensitive equipment. - **Safe and Power-On Values:** Configurable safe-state and power-on output values ensure predictable behavior during startup or communication loss. - **Current Readback Function:** Enables monitoring of actual output current for diagnostic and verification purposes. - **Low Power Consumption:** Typical power consumption of 2 W, suitable for distributed I/O systems. - **Calibration and Configuration Commands:** Comprehensive command set for calibration, configuration, and monitoring via RS485 communication.

Manufacturer: TOPSCCC

Category: Module AD Out

Request a quote
4.4.1.2.2 1*DA 16-bit analog out RS485 Module EX9021P
1*DA 16-bit analog out RS485 Module

- **High Resolution:** 16-bit digital-to-analog conversion for precise output control. - **Single Analog Output Channel:** Supports one configurable output channel for voltage or current signals. - **Output Range Flexibility:** Selectable output ranges of 0–10 VDC, 0–20 mA, or 4–20 mA. - **RS-485 Communication Interface:** Fully compatible with standard RS-485 networks using ASCII command protocol. - **Wide Operating Temperature Range:** Designed for industrial environments with extended temperature tolerance. - **Dual Watchdog Timer (WDT):** Ensures system reliability by monitoring both host and module operation. - **Safe and Power-On Values:** Configurable safe-state and power-on output values for fail-safe operation. - **Internal or External Power Drive:** Internal power supports up to 500 Ω load; external 24 V supply supports up to 1050 Ω load. - **Programmable Slew Rate Control:** Adjustable output transition rate from immediate change to gradual ramping (0.0625 V/s to 512 V/s or equivalent current rates). - **Current Readback Function:** Integrated A/D converter for monitoring actual output current, enabling fault detection. - **Low Power Consumption:** Typical consumption of 2 W. - **Compact Modular Design:** Fits within the EX9000 series modular I/O system for distributed automation.

Manufacturer: TOPSCCC

Category: Module AD Out

Request a quote
4.4.1.2.2 2*DA 12-bit analog (isolated channel to channel) RS485 EX9022
2*DA 12-bit analog (isolated channel to channel) RS485

- **Dual Isolated Analog Outputs:** Two independent, channel-to-channel isolated outputs for enhanced signal integrity and noise immunity. - **12-bit Resolution:** Provides fine analog signal granularity suitable for precision control applications. - **Flexible Output Ranges:** Supports voltage output (0–10 VDC) and current output (0–20 mA or 4–20 mA). - **RS-485 Communication Interface:** Enables multi-drop networking and long-distance communication in industrial environments. - **Wide Operating Temperature Range:** Designed for extended temperature operation, suitable for harsh industrial conditions. - **Programmable Slew Rate Control:** Allows smooth, controlled transitions between output values to prevent abrupt signal changes. - **Current Readback Function:** Integrated A/D converter enables real-time monitoring of output current for diagnostics and verification. - **Dual Watchdog Timers (WDT):** Ensures system reliability by monitoring both host communication and internal operation. - **Safe and Power-On Values:** Configurable default output states for power-up and communication failure conditions. - **Low Power Consumption:** Typical power usage of 2 W, minimizing system energy requirements. - **Flexible Power Options:** Can operate with internal power (up to 500 Ω load) or external 24 V supply (up to 1050 Ω load). - **Compact Modular Design:** Easily integrates into distributed control systems with minimal wiring complexity.

Manufacturer: TOPSCCC

Category: Module AD Out

260,00 EUR (w/o VAT)
4.4.1.2.2 4*AD 14-bit analog RS485 Module EX9024
4*AD 14-bit analog RS485 Module

- **Four Analog Output Channels:** Each channel can be independently configured for voltage or current output. - **High Resolution:** 14-bit digital-to-analog conversion ensures fine output granularity and precise signal generation. - **Multiple Output Ranges:** Supports ±10 V, ±5 V, 0–10 V, 0–5 V, 0–20 mA, and 4–20 mA ranges. - **RS-485 Communication Interface:** Fully compatible with standard RS-485 networks, allowing multi-drop communication and long-distance data transmission. - **Programmable Slew Rate Control:** Adjustable output transition rate from immediate change to gradual slopes up to 1024 V/s or 2048 mA/s, minimizing transient effects in sensitive systems. - **Dual Watchdog Timers:** Ensures reliable operation and automatic recovery in case of communication or host failure. - **Safe and Power-On Values:** Configurable default output states for power-up and communication failure conditions. - **Flexible Power Options:** Internal power mode supports up to 500 Ω load; external 24 V supply supports up to 1050 Ω load. - **Wide Operating Temperature Range:** Designed for industrial environments with extended temperature tolerance. - **Compact and Modular Design:** Fits within the EX9000 AIO modular system for scalable analog I/O expansion. - **Low Power Consumption:** Typical consumption of 2 W. - **Firmware and Configuration Commands:** Comprehensive command set for calibration, configuration, and diagnostics via serial interface.

Manufacturer: TOPSCCC

Category: Module AD Out

208,00 EUR (w/o VAT)