- High-Speed Analog Input:
64 single-ended or 32 differential analog input channels with 12-bit resolution and up to 3 MS/s sampling rate.
Supports both unipolar and bipolar input ranges from ±0.05 V to ±10 V and 0–10 V to 0–0.1 V.
- Analog Output Capability:
Two 12-bit analog output channels with ±10 V or 0–10 V ranges and 1 MS/s maximum update rate.
Each channel includes a 1 k-sample FIFO buffer for waveform generation.
- Digital I/O:
24-channel TTL-compatible programmable digital I/O (8255 PIO) for control and monitoring applications.
- Timer/Counter:
Two 16-bit general-purpose up/down counters with 40 MHz internal or up to 10 MHz external clock input.
- Triggering and Synchronization:
Supports software, external analog/digital, and SSI (System Synchronization Interface) triggers.
Multiple trigger modes: pre-trigger, post-trigger, middle-trigger, delay-trigger, and re-trigger.
Synchronization across multiple cards via SSI or PXI trigger bus.
- Auto-Calibration:
Fully automatic calibration with onboard 5.000 V reference (±2 ppm/°C) ensures long-term accuracy.
- High Bandwidth and Low Noise:
2 MHz small-signal bandwidth at ±10 V range and 90 dB CMRR (gain = 1).
Typical system noise <1 LSB_rms.
- Software and OS Support:
Compatible with Windows 7/8 (x86/x64) and Linux.
Drivers and SDKs available for LabVIEW, MATLAB, C/C++, Visual Basic, and Visual Studio.NET.
Includes AD-Logger utility for data logging.
- Plug-and-Play PCI Interface:
32-bit, 3.3 V/5 V PCI bus interface with automatic resource configuration.
64 single-ended or 32 differential analog input channels with 12-bit resolution and up to 3 MS/s sampling rate.
Supports both unipolar and bipolar input ranges from ±0.05 V to ±10 V and 0–10 V to 0–0.1 V.
- Analog Output Capability:
Two 12-bit analog output channels with ±10 V or 0–10 V ranges and 1 MS/s maximum update rate.
Each channel includes a 1 k-sample FIFO buffer for waveform generation.
- Digital I/O:
24-channel TTL-compatible programmable digital I/O (8255 PIO) for control and monitoring applications.
- Timer/Counter:
Two 16-bit general-purpose up/down counters with 40 MHz internal or up to 10 MHz external clock input.
- Triggering and Synchronization:
Supports software, external analog/digital, and SSI (System Synchronization Interface) triggers.
Multiple trigger modes: pre-trigger, post-trigger, middle-trigger, delay-trigger, and re-trigger.
Synchronization across multiple cards via SSI or PXI trigger bus.
- Auto-Calibration:
Fully automatic calibration with onboard 5.000 V reference (±2 ppm/°C) ensures long-term accuracy.
- High Bandwidth and Low Noise:
2 MHz small-signal bandwidth at ±10 V range and 90 dB CMRR (gain = 1).
Typical system noise <1 LSB_rms.
- Software and OS Support:
Compatible with Windows 7/8 (x86/x64) and Linux.
Drivers and SDKs available for LabVIEW, MATLAB, C/C++, Visual Basic, and Visual Studio.NET.
Includes AD-Logger utility for data logging.
- Plug-and-Play PCI Interface:
32-bit, 3.3 V/5 V PCI bus interface with automatic resource configuration.
Comprehensive Product Summary – ADLINK DAQ-2204 PCI Data Acquisition Card
### 1. Product Overview
Product Name: DAQ-2204
Model: DAQ-2204
Series: PXI/DAQ/DAQe-2200 Series
Article Number: DAQ-2204
Manufacturer: ADLINK Technology Inc.
The ADLINK DAQ-2204 is a high-performance, multifunction PCI data acquisition (DAQ) card designed for precision analog and digital signal measurement and generation. It belongs to the PXI/DAQ/DAQe-2200 Series, which includes PCI, PXI, and PCI Express variants. The DAQ-2204 model specifically supports a 32-bit PCI bus interface and delivers up to 3 MS/s sampling rate with 12-bit resolution across 64 single-ended or 32 differential analog input channels. It integrates analog input/output, digital I/O, and counter/timer functions in a single board, making it ideal for laboratory automation, industrial testing, and signal analysis applications.
### 2. Key Features
- High-Speed Analog Input:
64 single-ended or 32 differential analog input channels with 12-bit resolution and up to 3 MS/s sampling rate.
Supports both unipolar and bipolar input ranges from ±0.05 V to ±10 V and 0–10 V to 0–0.1 V.
- Analog Output Capability:
Two 12-bit analog output channels with ±10 V or 0–10 V ranges and 1 MS/s maximum update rate.
Each channel includes a 1 k-sample FIFO buffer for waveform generation.
- Digital I/O:
24-channel TTL-compatible programmable digital I/O (8255 PIO) for control and monitoring applications.
- Timer/Counter:
Two 16-bit general-purpose up/down counters with 40 MHz internal or up to 10 MHz external clock input.
- Triggering and Synchronization:
Supports software, external analog/digital, and SSI (System Synchronization Interface) triggers.
Multiple trigger modes: pre-trigger, post-trigger, middle-trigger, delay-trigger, and re-trigger.
Synchronization across multiple cards via SSI or PXI trigger bus.
- Auto-Calibration:
Fully automatic calibration with onboard 5.000 V reference (±2 ppm/°C) ensures long-term accuracy.
- High Bandwidth and Low Noise:
2 MHz small-signal bandwidth at ±10 V range and 90 dB CMRR (gain = 1).
Typical system noise <1 LSB_rms.
- Software and OS Support:
Compatible with Windows 7/8 (x86/x64) and Linux.
Drivers and SDKs available for LabVIEW, MATLAB, C/C++, Visual Basic, and Visual Studio.NET.
Includes AD-Logger utility for data logging.
- Plug-and-Play PCI Interface:
32-bit, 3.3 V/5 V PCI bus interface with automatic resource configuration.
### 3. Technical Specifications
Analog Input (AI):
- Channels: 64 SE / 32 DI (software selectable per channel)
- Resolution: 12-bit, no missing codes
- Sampling Rate: Up to 3 MS/s (single channel)
- Input Ranges (Bipolar): ±10 V, ±5 V, ±2.5 V, ±1.25 V, ±0.05 V
- Input Ranges (Unipolar): 0–10 V, 0–5 V, 0–2.5 V, 0–1.25 V, 0–0.1 V
- Programmable Gains: x1, x2, x4, x5, x8, x10, x20, x40, x50, x200
- Input Coupling: DC
- Input Impedance: 1 GΩ / 100 pF
- Overvoltage Protection: ±30 V (power on), ±15 V (power off)
- Offset Error: ±2 mV
- Gain Error: ±0.06% of FSR
- CMRR: 90 dB (gain = 1)
- Settling Time: 1 µs to 0.1% error
- Bandwidth (-3 dB): 2 MHz (±10 V, gain = 1)
- FIFO Buffer: 1 k-sample
- Data Transfer: Polling or scatter-gather DMA
Analog Output (AO):
- Channels: 2
- Resolution: 12-bit
- Output Range: ±10 V, 0–10 V, ±AOEXTREF, 0–AOEXTREF
- Update Rate: 1 MS/s
- Slew Rate: 20 V/µs
- Settling Time: 3 µs to ±0.5 LSB
- Output Drive: ±5 mA, stable up to 1500 pF load
- FIFO Buffer: 1 k-sample
- Trigger Sources: Software, external analog/digital, SSI
- Data Transfer: Programmed I/O or scatter-gather DMA
Digital I/O:
- Channels: 24 (8255 PIO)
- Logic Level: 5 V TTL
- Direction: Programmable input/output
Timer/Counter:
- Channels: 2
- Resolution: 16-bit
- Base Clock: 40 MHz internal, up to 10 MHz external
General:
- Auto Calibration: Yes (+5 V reference, ±2 ppm/°C)
- Dimensions: 175 mm × 107 mm (6.82" × 4.17")
- Connectors: Two 68-pin VHDCI female connectors
- Operating Temperature: 0°C to 55°C
- Storage Temperature: -20°C to 70°C
- Humidity: 5–95%, non-condensing
- Power Requirements: +5 V @ 1.3 A typical
### 4. Functionality
The DAQ-2204 performs high-speed analog-to-digital (A/D) and digital-to-analog (D/A) conversions, digital I/O operations, and timing/counter functions. It supports both single-ended and differential analog input configurations, selectable per channel. The card’s programmable gain amplifier allows flexible scaling of input signals, while the onboard FIFO buffers enable continuous high-speed data streaming via DMA.
Use Cases:
- Data logging and waveform acquisition
- Signal analysis and transient capture
- Automated test equipment (ATE)
- Process control and monitoring
- Biomedical and biotech instrumentation
- Automotive and cable testing
Compatibility:
- PCI bus systems (32-bit, 3.3 V/5 V)
- Compatible with ADLINK terminal boards (DIN-68S-01, ACL-10568-1)
- Software integration with LabVIEW, MATLAB, and C/C++ environments
### 5. Components & Accessories
Included Items:
- DAQ-2204 PCI data acquisition card
- ADLINK All-in-One software CD
- Software Installation Guide
- User’s Manual
Optional Accessories:
- Terminal Boards: DIN-68S-01, ACL-10568-1
- Cables: ACL-SSI-2/3/4 for multi-card synchronization
- SSI Connector: 20-pin ribbon connector for synchronization
Connectors:
- Two 68-pin VHDCI connectors for analog, digital, and timing I/O
- 20-pin SSI connector for synchronization signals
### 6. Installation & Setup
Requirements:
- PCI slot (32-bit, 3.3 V or 5 V)
- Supported OS: Windows 7/8 (x86/x64), Linux
Mounting:
- Standard PCI form factor, 175 × 107 mm board size
- Plug-and-play configuration (no jumpers required)
Configuration:
- Automatic IRQ and I/O address assignment via BIOS
- Software-configurable channel modes, gains, and ranges
- Supports multiple cards synchronized via SSI or PXI trigger bus
Setup Steps:
1. Install the card in a grounded PCI slot.
2. Connect VHDCI cables to terminal boards.
3. Install drivers and SDK from the ADLINK CD.
4. Configure channels and triggers using AD-Logger or SDK functions.
### 7. Performance & Capabilities
- Analog Input Performance:
3 MS/s maximum sampling rate with 12-bit resolution ensures accurate high-speed data capture.
2 MHz analog bandwidth supports wide dynamic signal measurement.
- Analog Output Performance:
1 MS/s update rate with 12-bit resolution for precise waveform generation.
Supports continuous, finite, and iterative waveform modes.
- DMA and FIFO Efficiency:
Scatter-gather DMA enables large data transfers without CPU overhead.
1 k-sample FIFO buffers for both A/D and D/A channels ensure smooth streaming.
- Triggering Flexibility:
Supports software, analog, and digital triggers with multiple modes (pre-, post-, middle-, delay-, re-trigger).
External synchronization via SSI allows multi-card timing alignment.
- Limitations:
- Analog output limited to ±10 V or 0–10 V ranges.
- Maximum load capacitance 1500 pF.
- Operating temperature limited to 55°C.
### 8. Standards & Compliance
- Bus Interface: 32-bit PCI (3.3 V/5 V)
- PXI Compliance: PXI Specification Rev. 2.2 (for PXI variant)
- Electrical Standards: TTL-compatible digital I/O
- Environmental: 0–55°C operation, 5–95% RH non-condensing
- Safety & EMC: Designed to meet industrial DAQ standards
- Software Standards: Compatible with major development environments (LabVIEW, MATLAB, C/C++, VB)
### 9. Additional Information
Warranty:
- Two-year limited warranty (one year in China).
- Covers manufacturing defects; excludes damage from misuse or environmental factors.
Support & Maintenance:
- Global technical support via ADLINK offices in Taiwan, USA, Europe, Singapore, India, Korea, and China.
- Email: service@adlinktech.com
- Website: [www.adlinktech.com](http://www.adlinktech.com)
Maintenance:
- Periodic calibration recommended for optimal accuracy.
- Auto-calibration feature compensates for drift and temperature variations.
Software Updates:
- Driver and SDK updates available via ADLINK website.
- Supported software packages: D2K-DASK (Windows), D2K-DASK/X (Linux), DAQ-LVIEW PnP (LabVIEW), D2K-OCX (ActiveX).
Calibration:
- Factory-calibrated with stored constants in EEPROM.
- Onboard 5.000 V reference (±2 ppm/°C) ensures precision.
- Auto-calibration adjusts gain and offset errors without external equipment.
Service Contacts:
- ADLINK Technology Inc. (Taiwan): +886-2-8226-5877
- ADLINK Technology America: +1-866-4-ADLINK
- ADLINK Europe: +49-211-4955552
- ADLINK Singapore: +65-6844-2261
### Summary
The ADLINK DAQ-2204 is a robust, high-speed PCI data acquisition card engineered for demanding measurement and control applications. With 64 analog input channels, dual analog outputs, 24 digital I/O lines, and dual 16-bit counters, it provides a complete multifunction DAQ solution. Its 3 MS/s sampling rate, 12-bit resolution, and advanced triggering and synchronization capabilities make it suitable for high-precision, real-time data acquisition tasks. The card’s auto-calibration, scatter-gather DMA, and extensive software support ensure reliable performance and easy integration into diverse test and automation systems.
Ideal Applications:
- Industrial process monitoring
- Automated test systems
- Scientific research instrumentation
- Signal analysis and waveform generation
- Multi-channel synchronized data logging
End of Product Summary – ADLINK DAQ-2204 PCI AD Card (3 MS/s, 12-bit, 64-CH, 1024W FIFO)
### 1. Product Overview
Product Name: DAQ-2204
Model: DAQ-2204
Series: PXI/DAQ/DAQe-2200 Series
Article Number: DAQ-2204
Manufacturer: ADLINK Technology Inc.
The ADLINK DAQ-2204 is a high-performance, multifunction PCI data acquisition (DAQ) card designed for precision analog and digital signal measurement and generation. It belongs to the PXI/DAQ/DAQe-2200 Series, which includes PCI, PXI, and PCI Express variants. The DAQ-2204 model specifically supports a 32-bit PCI bus interface and delivers up to 3 MS/s sampling rate with 12-bit resolution across 64 single-ended or 32 differential analog input channels. It integrates analog input/output, digital I/O, and counter/timer functions in a single board, making it ideal for laboratory automation, industrial testing, and signal analysis applications.
### 2. Key Features
- High-Speed Analog Input:
64 single-ended or 32 differential analog input channels with 12-bit resolution and up to 3 MS/s sampling rate.
Supports both unipolar and bipolar input ranges from ±0.05 V to ±10 V and 0–10 V to 0–0.1 V.
- Analog Output Capability:
Two 12-bit analog output channels with ±10 V or 0–10 V ranges and 1 MS/s maximum update rate.
Each channel includes a 1 k-sample FIFO buffer for waveform generation.
- Digital I/O:
24-channel TTL-compatible programmable digital I/O (8255 PIO) for control and monitoring applications.
- Timer/Counter:
Two 16-bit general-purpose up/down counters with 40 MHz internal or up to 10 MHz external clock input.
- Triggering and Synchronization:
Supports software, external analog/digital, and SSI (System Synchronization Interface) triggers.
Multiple trigger modes: pre-trigger, post-trigger, middle-trigger, delay-trigger, and re-trigger.
Synchronization across multiple cards via SSI or PXI trigger bus.
- Auto-Calibration:
Fully automatic calibration with onboard 5.000 V reference (±2 ppm/°C) ensures long-term accuracy.
- High Bandwidth and Low Noise:
2 MHz small-signal bandwidth at ±10 V range and 90 dB CMRR (gain = 1).
Typical system noise <1 LSB_rms.
- Software and OS Support:
Compatible with Windows 7/8 (x86/x64) and Linux.
Drivers and SDKs available for LabVIEW, MATLAB, C/C++, Visual Basic, and Visual Studio.NET.
Includes AD-Logger utility for data logging.
- Plug-and-Play PCI Interface:
32-bit, 3.3 V/5 V PCI bus interface with automatic resource configuration.
### 3. Technical Specifications
Analog Input (AI):
- Channels: 64 SE / 32 DI (software selectable per channel)
- Resolution: 12-bit, no missing codes
- Sampling Rate: Up to 3 MS/s (single channel)
- Input Ranges (Bipolar): ±10 V, ±5 V, ±2.5 V, ±1.25 V, ±0.05 V
- Input Ranges (Unipolar): 0–10 V, 0–5 V, 0–2.5 V, 0–1.25 V, 0–0.1 V
- Programmable Gains: x1, x2, x4, x5, x8, x10, x20, x40, x50, x200
- Input Coupling: DC
- Input Impedance: 1 GΩ / 100 pF
- Overvoltage Protection: ±30 V (power on), ±15 V (power off)
- Offset Error: ±2 mV
- Gain Error: ±0.06% of FSR
- CMRR: 90 dB (gain = 1)
- Settling Time: 1 µs to 0.1% error
- Bandwidth (-3 dB): 2 MHz (±10 V, gain = 1)
- FIFO Buffer: 1 k-sample
- Data Transfer: Polling or scatter-gather DMA
Analog Output (AO):
- Channels: 2
- Resolution: 12-bit
- Output Range: ±10 V, 0–10 V, ±AOEXTREF, 0–AOEXTREF
- Update Rate: 1 MS/s
- Slew Rate: 20 V/µs
- Settling Time: 3 µs to ±0.5 LSB
- Output Drive: ±5 mA, stable up to 1500 pF load
- FIFO Buffer: 1 k-sample
- Trigger Sources: Software, external analog/digital, SSI
- Data Transfer: Programmed I/O or scatter-gather DMA
Digital I/O:
- Channels: 24 (8255 PIO)
- Logic Level: 5 V TTL
- Direction: Programmable input/output
Timer/Counter:
- Channels: 2
- Resolution: 16-bit
- Base Clock: 40 MHz internal, up to 10 MHz external
General:
- Auto Calibration: Yes (+5 V reference, ±2 ppm/°C)
- Dimensions: 175 mm × 107 mm (6.82" × 4.17")
- Connectors: Two 68-pin VHDCI female connectors
- Operating Temperature: 0°C to 55°C
- Storage Temperature: -20°C to 70°C
- Humidity: 5–95%, non-condensing
- Power Requirements: +5 V @ 1.3 A typical
### 4. Functionality
The DAQ-2204 performs high-speed analog-to-digital (A/D) and digital-to-analog (D/A) conversions, digital I/O operations, and timing/counter functions. It supports both single-ended and differential analog input configurations, selectable per channel. The card’s programmable gain amplifier allows flexible scaling of input signals, while the onboard FIFO buffers enable continuous high-speed data streaming via DMA.
Use Cases:
- Data logging and waveform acquisition
- Signal analysis and transient capture
- Automated test equipment (ATE)
- Process control and monitoring
- Biomedical and biotech instrumentation
- Automotive and cable testing
Compatibility:
- PCI bus systems (32-bit, 3.3 V/5 V)
- Compatible with ADLINK terminal boards (DIN-68S-01, ACL-10568-1)
- Software integration with LabVIEW, MATLAB, and C/C++ environments
### 5. Components & Accessories
Included Items:
- DAQ-2204 PCI data acquisition card
- ADLINK All-in-One software CD
- Software Installation Guide
- User’s Manual
Optional Accessories:
- Terminal Boards: DIN-68S-01, ACL-10568-1
- Cables: ACL-SSI-2/3/4 for multi-card synchronization
- SSI Connector: 20-pin ribbon connector for synchronization
Connectors:
- Two 68-pin VHDCI connectors for analog, digital, and timing I/O
- 20-pin SSI connector for synchronization signals
### 6. Installation & Setup
Requirements:
- PCI slot (32-bit, 3.3 V or 5 V)
- Supported OS: Windows 7/8 (x86/x64), Linux
Mounting:
- Standard PCI form factor, 175 × 107 mm board size
- Plug-and-play configuration (no jumpers required)
Configuration:
- Automatic IRQ and I/O address assignment via BIOS
- Software-configurable channel modes, gains, and ranges
- Supports multiple cards synchronized via SSI or PXI trigger bus
Setup Steps:
1. Install the card in a grounded PCI slot.
2. Connect VHDCI cables to terminal boards.
3. Install drivers and SDK from the ADLINK CD.
4. Configure channels and triggers using AD-Logger or SDK functions.
### 7. Performance & Capabilities
- Analog Input Performance:
3 MS/s maximum sampling rate with 12-bit resolution ensures accurate high-speed data capture.
2 MHz analog bandwidth supports wide dynamic signal measurement.
- Analog Output Performance:
1 MS/s update rate with 12-bit resolution for precise waveform generation.
Supports continuous, finite, and iterative waveform modes.
- DMA and FIFO Efficiency:
Scatter-gather DMA enables large data transfers without CPU overhead.
1 k-sample FIFO buffers for both A/D and D/A channels ensure smooth streaming.
- Triggering Flexibility:
Supports software, analog, and digital triggers with multiple modes (pre-, post-, middle-, delay-, re-trigger).
External synchronization via SSI allows multi-card timing alignment.
- Limitations:
- Analog output limited to ±10 V or 0–10 V ranges.
- Maximum load capacitance 1500 pF.
- Operating temperature limited to 55°C.
### 8. Standards & Compliance
- Bus Interface: 32-bit PCI (3.3 V/5 V)
- PXI Compliance: PXI Specification Rev. 2.2 (for PXI variant)
- Electrical Standards: TTL-compatible digital I/O
- Environmental: 0–55°C operation, 5–95% RH non-condensing
- Safety & EMC: Designed to meet industrial DAQ standards
- Software Standards: Compatible with major development environments (LabVIEW, MATLAB, C/C++, VB)
### 9. Additional Information
Warranty:
- Two-year limited warranty (one year in China).
- Covers manufacturing defects; excludes damage from misuse or environmental factors.
Support & Maintenance:
- Global technical support via ADLINK offices in Taiwan, USA, Europe, Singapore, India, Korea, and China.
- Email: service@adlinktech.com
- Website: [www.adlinktech.com](http://www.adlinktech.com)
Maintenance:
- Periodic calibration recommended for optimal accuracy.
- Auto-calibration feature compensates for drift and temperature variations.
Software Updates:
- Driver and SDK updates available via ADLINK website.
- Supported software packages: D2K-DASK (Windows), D2K-DASK/X (Linux), DAQ-LVIEW PnP (LabVIEW), D2K-OCX (ActiveX).
Calibration:
- Factory-calibrated with stored constants in EEPROM.
- Onboard 5.000 V reference (±2 ppm/°C) ensures precision.
- Auto-calibration adjusts gain and offset errors without external equipment.
Service Contacts:
- ADLINK Technology Inc. (Taiwan): +886-2-8226-5877
- ADLINK Technology America: +1-866-4-ADLINK
- ADLINK Europe: +49-211-4955552
- ADLINK Singapore: +65-6844-2261
### Summary
The ADLINK DAQ-2204 is a robust, high-speed PCI data acquisition card engineered for demanding measurement and control applications. With 64 analog input channels, dual analog outputs, 24 digital I/O lines, and dual 16-bit counters, it provides a complete multifunction DAQ solution. Its 3 MS/s sampling rate, 12-bit resolution, and advanced triggering and synchronization capabilities make it suitable for high-precision, real-time data acquisition tasks. The card’s auto-calibration, scatter-gather DMA, and extensive software support ensure reliable performance and easy integration into diverse test and automation systems.
Ideal Applications:
- Industrial process monitoring
- Automated test systems
- Scientific research instrumentation
- Signal analysis and waveform generation
- Multi-channel synchronized data logging
End of Product Summary – ADLINK DAQ-2204 PCI AD Card (3 MS/s, 12-bit, 64-CH, 1024W FIFO)
-
DAQ_DAQe_PXI-2204_2205_2206_Datasheet_en_2.pdf
PDF Catalog
- DIN-68S-01 - 68pin SCSI-II termination board DIN rail w/o cable
- ACL-10568-1 - SCSI-VHDCI cable 1m for DAQ series
- ACL-10568-2 - SCSI-VHDCI cable 2m for DAQ series
- ACL-10568-3 - SCSI-VHDCI cable 3m for DAQ series