LOOKING FOR THE RIGHT

INDUSTRIAL SOLUTION?

Discover embedded, communication and automation solutions tailored to your application.

DAQ-2206

PCI AD Card 250kS/s 16bit 64chan 1024W FIFO
1231,00 EUR

including VAT 1,464.89 EUR

  • Manufacturer Adlink Technology Inc.
  • Category: A/D Intelligent PCI
  • The ADLINK DAQ-2206 is a high-performance, 32-bit PCI-based data acquisition card designed for precision analog and digital signal measurement and generation. It belongs to the PXI/DAQ/DAQe-2200 Series, which includes multi-function DAQ cards supporting up to 3 MS/s sampling rates and 12/16-bit resolution. The DAQ-2206 specifically offers 16-bit resolution, a maximum sampling rate of 250 kS/s, and 64 single-ended or 32 differential analog input channels.
- Bus Interface: 32-bit PCI bus supporting 3.3 V or 5 V signaling; plug-and-play configuration.
- Analog Inputs: 64 single-ended or 32 differential channels, software-selectable per channel.
- Resolution: 16-bit, no missing codes.
- Sampling Rate: Up to 250 kS/s aggregate throughput.
- Input Range: Bipolar ±10 V, ±5 V, ±2.5 V, ±1.25 V; Unipolar 0–10 V, 0–5 V, 0–2.5 V, 0–1.25 V.
- Programmable Gain: x1, x2, x4, x8.
- FIFO Buffer: 1024-sample A/D FIFO and 1024-sample D/A FIFO.
- Analog Outputs: Two 12-bit voltage output channels (0–10 V, ±10 V, or external reference).
- Digital I/O: 24-channel TTL-compatible programmable I/O (8255 PIO).
- Counters/Timers: Two 16-bit general-purpose up/down counters with 40 MHz base clock.
- Triggering: Supports software, external analog, and digital triggers; pre-, post-, middle-, and delay-trigger modes.
- Auto Calibration: Fully automatic calibration with onboard 5.000 V reference (±2 ppm/°C).
- Synchronization: Multi-card synchronization via SSI (System Synchronization Interface) or PXI trigger bus.
- Software Support: Compatible with Windows and Linux; drivers for LabVIEW, MATLAB, C/C++, Visual Basic, and .NET.
- Utility Software: AD-Logger for data logging and analysis.
- Connectors: Two 68-pin VHDCI connectors for analog, digital, and timing signals.
- Form Factor: PCI card, dimensions 175 mm × 107 mm.

Country of origin: Taiwan R.O.C.

Customs tariff number: 8473 3020 000

Comprehensive Product Summary: ADLINK DAQ-2206 PCI Data Acquisition Card




### 1. Product Overview

Product Name: DAQ-2206
Model: DAQ-2206
Series: PXI/DAQ/DAQe-2200 Series
Article Number: DAQ-2206
Manufacturer: ADLINK Technology Inc.
Product Type: PCI Multi-Function Data Acquisition (DAQ) Card
Description: PCI AD Card 250 kS/s, 16-bit, 64-channel, 1024-word FIFO

The ADLINK DAQ-2206 is a high-performance, 32-bit PCI-based data acquisition card designed for precision analog and digital signal measurement and generation. It belongs to the PXI/DAQ/DAQe-2200 Series, which includes multi-function DAQ cards supporting up to 3 MS/s sampling rates and 12/16-bit resolution. The DAQ-2206 specifically offers 16-bit resolution, a maximum sampling rate of 250 kS/s, and 64 single-ended or 32 differential analog input channels. It integrates analog input/output, digital I/O, and counter/timer functions in a single board, making it ideal for laboratory automation, process control, and test applications.




### 2. Key Features

- Bus Interface: 32-bit PCI bus supporting 3.3 V or 5 V signaling; plug-and-play configuration.
- Analog Inputs: 64 single-ended or 32 differential channels, software-selectable per channel.
- Resolution: 16-bit, no missing codes.
- Sampling Rate: Up to 250 kS/s aggregate throughput.
- Input Range: Bipolar ±10 V, ±5 V, ±2.5 V, ±1.25 V; Unipolar 0–10 V, 0–5 V, 0–2.5 V, 0–1.25 V.
- Programmable Gain: x1, x2, x4, x8.
- FIFO Buffer: 1024-sample A/D FIFO and 1024-sample D/A FIFO.
- Analog Outputs: Two 12-bit voltage output channels (0–10 V, ±10 V, or external reference).
- Digital I/O: 24-channel TTL-compatible programmable I/O (8255 PIO).
- Counters/Timers: Two 16-bit general-purpose up/down counters with 40 MHz base clock.
- Triggering: Supports software, external analog, and digital triggers; pre-, post-, middle-, and delay-trigger modes.
- Auto Calibration: Fully automatic calibration with onboard 5.000 V reference (±2 ppm/°C).
- Synchronization: Multi-card synchronization via SSI (System Synchronization Interface) or PXI trigger bus.
- Software Support: Compatible with Windows and Linux; drivers for LabVIEW, MATLAB, C/C++, Visual Basic, and .NET.
- Utility Software: AD-Logger for data logging and analysis.
- Connectors: Two 68-pin VHDCI connectors for analog, digital, and timing signals.
- Form Factor: PCI card, dimensions 175 mm × 107 mm.




### 3. Technical Specifications

Analog Input (AI):
- Channels: 64 SE / 32 DI (software-selectable)
- Resolution: 16-bit, no missing codes
- Sampling Rate: 250 kS/s max
- Input Ranges:
- Bipolar: ±10 V, ±5 V, ±2.5 V, ±1.25 V
- Unipolar: 0–10 V, 0–5 V, 0–2.5 V, 0–1.25 V
- Input Coupling: DC
- Input Impedance: 1 GΩ / 100 pF
- Overvoltage Protection: ±30 V (power on), ±15 V (power off)
- Offset Error: ±2 mV
- Gain Error: ±0.06% of FSR
- CMRR (Gain=1): 83 dB
- Settling Time: 4 µs to 0.01% error
- Bandwidth (-3 dB): 600 kHz (±10 V, gain=1)
- FIFO Buffer: 1 k-sample
- Data Transfer: Polling or scatter-gather DMA

Analog Output (AO):
- Channels: 2
- Resolution: 12-bit
- Output Range: 0–10 V, ±10 V, 0–AOEXTREF, ±AOEXTREF
- Update Rate: 1 µs (1 MS/s)
- Slew Rate: 20 V/µs
- Settling Time: 3 µs to ±0.5 LSB
- Offset Error: ±1 mV
- Gain Error: ±0.02% of max output
- Drive Capability: ±5 mA, stable up to 1500 pF load
- Trigger Sources: Software, external analog/digital, SSI bus
- FIFO Buffer: 1 k-sample
- Data Transfer: Programmed I/O or scatter-gather DMA

Digital I/O:
- Channels: 24 (8255 PIO)
- Logic Levels: TTL (5 V compatible)
- Transfer Mode: Programmed I/O

Timer/Counter:
- Channels: 2
- Resolution: 16-bit
- Base Clock: 40 MHz internal, up to 10 MHz external

General Specifications:
- Auto Calibration: Yes (+5 V reference, ±2 ppm/°C)
- Dimensions: 175 mm × 107 mm (6.82" × 4.17")
- Connectors: Two 68-pin VHDCI female connectors
- Operating Temperature: 0°C to 55°C
- Storage Temperature: -20°C to 70°C
- Humidity: 5–95%, non-condensing
- Power Requirements: +5 V @ 1.2 A typical
- Weight: Approx. 300 g




### 4. Functionality

The DAQ-2206 performs high-precision analog-to-digital (A/D) and digital-to-analog (D/A) conversions, digital I/O control, and timing/counter operations. It is designed for applications requiring simultaneous multi-channel data acquisition, waveform generation, and event counting.

Use Cases and Applications:
- Laboratory automation and instrumentation
- Process control and monitoring
- Automotive and cable testing
- Transient signal measurement
- Automated Test Equipment (ATE)
- Biotech and medical signal acquisition

Compatibility:
- PCI bus (32-bit, 3.3 V/5 V)
- Supported OS: Windows 7/8 (x86/x64), Linux
- Supported APIs: LabVIEW, MATLAB, C/C++, Visual Basic, Visual Studio.NET

Operation Modes:
- A/D Conversion: Software polling or programmable scan acquisition with precise timing control.
- Triggering: Supports pre-, post-, middle-, and delay-trigger modes for flexible data capture.
- D/A Conversion: Software update or timed waveform generation with programmable delay and iteration.
- Digital I/O: Configurable as input or output for control and monitoring.
- Timer/Counter: Eight programmable modes for event counting, pulse generation, and frequency measurement.




### 5. Components & Accessories

Included Items:
- DAQ-2206 PCI Data Acquisition Card
- ADLINK All-in-One Software CD
- Software Installation Guide
- User’s Manual

Optional Accessories:
- Terminal Boards: DIN-68S-01
- Cables: ACL-10568-1 (68-pin VHDCI cable)
- Synchronization Cable: ACL-SSI-2/3/4 for multi-card synchronization

Connectors:
- Two 68-pin VHDCI connectors for analog, digital, and timing signals
- One 20-pin SSI connector for synchronization




### 6. Installation & Setup

Requirements:
- Available PCI slot (32-bit, 3.3 V or 5 V)
- Compatible operating system (Windows or Linux)
- Administrative privileges for driver installation

Mounting:
- Standard PCI card installation in desktop or industrial PC chassis
- Ensure anti-static handling during installation

Configuration:
- Plug-and-play PCI configuration (no jumpers required)
- Automatic IRQ and memory address assignment by BIOS
- Software utilities (PCI_SCAN) available for system configuration verification

Signal Connections:
- CN1: Analog input channels (AI0–AI63), EXTATRIG, AIGND
- CN2: Analog outputs (DA0OUT, DA1OUT), digital I/O ports (PA, PB, PC), GPTC signals, and external triggers
- SSI Connector: 20-pin header for synchronization signals (TIMEBASE, ADCONV, SCAN_START, etc.)




### 7. Performance & Capabilities

Analog Input Performance:
- 16-bit resolution ensures high precision with minimal quantization noise.
- 250 kS/s sampling rate suitable for medium-speed data acquisition.
- 600 kHz bandwidth supports accurate signal capture for dynamic signals.
- ±30 V overvoltage protection ensures robust operation in industrial environments.

Analog Output Performance:
- 12-bit resolution with 1 MS/s update rate for waveform generation.
- ±10 V output range supports standard instrumentation signals.
- Low offset and gain errors ensure accurate analog reproduction.

Digital I/O Performance:
- 24 TTL-compatible lines for control and monitoring.
- Programmable direction per port (input/output).

Counter/Timer Performance:
- Two 16-bit counters with 40 MHz internal clock.
- Supports event counting, frequency measurement, and pulse generation.

Efficiency & Limitations:
- Optimized for medium-speed, high-resolution applications.
- Not intended for ultra-high-speed (MHz-level) acquisition.
- Limited to 64 SE or 32 DI channels per card; expansion possible via SSI synchronization.




### 8. Standards & Compliance

- Bus Interface: PCI Local Bus Specification compliant
- PXI Compliance: PXI Specification Rev. 2.2 (for PXI variants)
- Electrical Standards: TTL-compatible digital I/O
- Environmental: Operating 0–55°C, storage -20–70°C, 5–95% RH non-condensing
- Safety & EMC: Designed to meet industrial EMC and safety standards
- Software Drivers: D2K-DASK (Windows), D2K-DASK/X (Linux)
- Supported Development Environments:
- LabVIEW (DAQ-LVIEW PnP)
- MATLAB
- Visual Studio (C/C++, VB, .NET)
- ActiveX (D2K-OCX)
- HP VEE (D2K-VEE)




### 9. Additional Information

Warranty:
- Standard 2-year limited warranty (1 year in China)
- Covers manufacturing defects and hardware failures under normal use
- Excludes damage from misuse, improper installation, or environmental factors

Support & Maintenance:
- Global technical support via ADLINK regional offices (Taiwan, USA, Europe, Singapore, China, Korea, India)
- Email: service@adlinktech.com
- Website: [www.adlinktech.com](http://www.adlinktech.com)
- RMA and repair services available via [rma.adlinktech.com/policy](http://rma.adlinktech.com/policy)

Calibration & Maintenance:
- Factory-calibrated with stored constants in EEPROM
- Auto-calibration feature compensates for drift and temperature variations
- Recommended warm-up time: 15 minutes before calibration
- Calibration constants can be saved and reloaded for different environments

Software Updates:
- Driver and SDK updates available from ADLINK’s website
- Compatible with legacy and modern OS versions
- Includes sample programs and documentation for rapid development




### Summary

The ADLINK DAQ-2206 is a robust, high-precision PCI data acquisition card engineered for multi-channel analog and digital signal processing. With 16-bit resolution, 250 kS/s sampling rate, and comprehensive I/O capabilities, it provides a balanced solution for laboratory, industrial, and research applications. Its auto-calibration, flexible triggering, and synchronization features make it suitable for complex measurement systems requiring reliability and accuracy. The DAQ-2206 integrates seamlessly with major software environments and supports both Windows and Linux platforms, ensuring long-term usability and scalability in diverse automation and testing setups.