LOOKING FOR THE RIGHT
INDUSTRIAL SOLUTION?
Discover embedded, communication and automation solutions tailored to your application.
- Universal Compatibility: Works with virtually all industrial box‑PCs and embedded controllers without requiring proprietary drivers or software.
- Supercapacitor‑Based Energy Storage: Utilizes four 370 F / 3.0 V supercapacitors, providing 4600 J of stored energy for uninterruptible operation.
- Wide Operating Temperature: Reliable performance from –25 °C to +65 °C (up to 85 °C with reduced capacity).
- Long Service Life: Over 10 years of expected lifespan and 500,000 charge/discharge cycles.
- High Output Power: Delivers up to 100 W continuous output (180 W peak) to the connected system.
- Patented CAP Energy Management: Intelligent microcontroller‑based energy management ensures safe shutdown, optimized charge/discharge cycles, and extended capacitor life (up to 4.8× longer).
- Multiple Operating Modes:
- Normal Backup Mode – standard UPS‑like operation.
- Ignition Control Mode – for in‑vehicle systems requiring ignition‑based power sequencing.
- Ignition Relay Mode – relays ignition signals for transportation controllers.
- Automatic System Control: Supports automatic boot and shutdown via RS‑232 and isolated digital I/O (PWR_BTN# / SYS_STAT).
- Maintenance‑Free Operation: No battery replacement required; supercapacitors are solid‑state and environmentally friendly.
- Industrial Certifications: EN50155, CE, and FCC Class A compliance for vibration, shock, and EMC.
- Flexible Mounting: DIN‑rail and wall‑mount options for versatile installation.
- Compact Rugged Design: 82.5 mm (W) × 175.2 mm (H) × 128.2 mm (D), 1.68 kg aluminum chassis.
- Supercapacitor‑Based Energy Storage: Utilizes four 370 F / 3.0 V supercapacitors, providing 4600 J of stored energy for uninterruptible operation.
- Wide Operating Temperature: Reliable performance from –25 °C to +65 °C (up to 85 °C with reduced capacity).
- Long Service Life: Over 10 years of expected lifespan and 500,000 charge/discharge cycles.
- High Output Power: Delivers up to 100 W continuous output (180 W peak) to the connected system.
- Patented CAP Energy Management: Intelligent microcontroller‑based energy management ensures safe shutdown, optimized charge/discharge cycles, and extended capacitor life (up to 4.8× longer).
- Multiple Operating Modes:
- Normal Backup Mode – standard UPS‑like operation.
- Ignition Control Mode – for in‑vehicle systems requiring ignition‑based power sequencing.
- Ignition Relay Mode – relays ignition signals for transportation controllers.
- Automatic System Control: Supports automatic boot and shutdown via RS‑232 and isolated digital I/O (PWR_BTN# / SYS_STAT).
- Maintenance‑Free Operation: No battery replacement required; supercapacitors are solid‑state and environmentally friendly.
- Industrial Certifications: EN50155, CE, and FCC Class A compliance for vibration, shock, and EMC.
- Flexible Mounting: DIN‑rail and wall‑mount options for versatile installation.
- Compact Rugged Design: 82.5 mm (W) × 175.2 mm (H) × 128.2 mm (D), 1.68 kg aluminum chassis.
Comprehensive Product Summary – Neousys PB‑4600J‑SA Supercapacitor‑Based Uninterruptible Power Backup
### 1. Product Overview
Product Name: PB‑4600J‑SA
Article Number: PB‑4600J‑SA
Series: PB‑J‑SA Industrial Supercapacitor UPS Modules
Manufacturer: Neousys Technology Inc.
Product Type: Standalone intelligent supercapacitor‑based uninterruptible power backup module
Energy Capacity: 4600 J (watt‑seconds)
Patented Technology: CAP Energy Management Technology (R.O.C. Patent No. I598820)
Certification: EN50155 certified for railway and transportation applications
The Neousys PB‑4600J‑SA is a rugged, industrial‑grade, maintenance‑free power backup solution designed to protect embedded box‑PCs and industrial controllers from power interruptions. It employs high‑reliability supercapacitors instead of traditional batteries, offering extended service life, rapid charge/discharge capability, and wide‑temperature operation suitable for harsh environments.
### 2. Key Features
- Universal Compatibility: Works with virtually all industrial box‑PCs and embedded controllers without requiring proprietary drivers or software.
- Supercapacitor‑Based Energy Storage: Utilizes four 370 F / 3.0 V supercapacitors, providing 4600 J of stored energy for uninterruptible operation.
- Wide Operating Temperature: Reliable performance from –25 °C to +65 °C (up to 85 °C with reduced capacity).
- Long Service Life: Over 10 years of expected lifespan and 500,000 charge/discharge cycles.
- High Output Power: Delivers up to 100 W continuous output (180 W peak) to the connected system.
- Patented CAP Energy Management: Intelligent microcontroller‑based energy management ensures safe shutdown, optimized charge/discharge cycles, and extended capacitor life (up to 4.8× longer).
- Multiple Operating Modes:
- Normal Backup Mode – standard UPS‑like operation.
- Ignition Control Mode – for in‑vehicle systems requiring ignition‑based power sequencing.
- Ignition Relay Mode – relays ignition signals for transportation controllers.
- Automatic System Control: Supports automatic boot and shutdown via RS‑232 and isolated digital I/O (PWR_BTN# / SYS_STAT).
- Maintenance‑Free Operation: No battery replacement required; supercapacitors are solid‑state and environmentally friendly.
- Industrial Certifications: EN50155, CE, and FCC Class A compliance for vibration, shock, and EMC.
- Flexible Mounting: DIN‑rail and wall‑mount options for versatile installation.
- Compact Rugged Design: 82.5 mm (W) × 175.2 mm (H) × 128.2 mm (D), 1.68 kg aluminum chassis.
### 3. Technical Specifications
Supercapacitor Configuration
- Composition: 4 × 370 F / 3.0 V supercapacitors
- Energy Capacity: 4600 J (watt‑seconds)
- Expected Lifespan: > 10 years*
- Lifecycle: 500,000 charge/discharge cycles*
Electrical Characteristics
- Input Voltage: 12 – 35 V DC
- Input Connector: 1 × 3‑pin pluggable terminal block (V+, GND, IGN_IN)
- Output Voltage: 12 V or 24 V (software‑configurable during discharge)
- Output Power: Maximum 100 W continuous (up to 180 W peak)
- Output Connector: 1 × 3‑pin pluggable terminal block (V+, GND, IGN_OUT)
- I/O Interface:
- 1 × DB9 RS‑232 (3‑wire)
- 1 × 10‑pin pluggable terminal block for isolated DIO (PWR_BTN# output / SYS_STAT input)
Mechanical
- Dimensions: 82.5 mm (W) × 175.2 mm (H) × 128.2 mm (D)
- Weight: 1.68 kg
- Mounting: DIN‑rail and wall‑mount brackets
Environmental
- Operating Temperature: –25 °C to +65 °C (–40 °C to +85 °C with reduced capacity)
- Storage Temperature: –40 °C to +85 °C
- Vibration: IEC 61373:2010 Category 1 Class B (EN50155 compliant)
- Shock: IEC 61373:2010 Category 1 Class B (EN50155 compliant)
- EMC: EN50155:2007, CE/FCC Class A (EN 55032 & EN 55035)
\* To achieve > 10 years lifespan under 24/7 operation at 65 °C, charge to 3245 J energy level using 4.8× SuperCAP Lifetime Extension setting.
### 4. Functionality
The PB‑4600J‑SA functions as an intelligent, standalone uninterruptible power backup module. It continuously monitors input voltage and system status, charging its supercapacitors when external DC power is available. Upon power loss, it instantly switches to discharge mode, supplying regulated 12 V or 24 V DC to the connected system, ensuring uninterrupted operation and controlled shutdown.
Operating Modes:
1. Normal Backup Mode:
- Standard UPS operation for industrial PCs.
- Automatically charges when DC input is present.
- Provides backup power during outages and initiates safe shutdown via PWR_BTN# signal.
2. Ignition Control Mode:
- Designed for in‑vehicle controllers lacking native ignition control.
- Responds to IGN signal input to power on/off the system with user‑defined on/off delays.
3. Ignition Relay Mode:
- Passes ignition signals directly to the back‑end system.
- Suitable for transportation and automotive applications requiring synchronized ignition behavior.
Compatibility:
- Works with most off‑the‑shelf box‑PCs, embedded controllers, and industrial automation systems.
- Communicates via RS‑232 COM port and isolated digital I/O for system integration.
- No additional drivers or software required for basic operation.
Applications:
- Industrial automation and control systems
- Transportation and railway computing (EN50155 certified)
- In‑vehicle data acquisition and surveillance systems
- Edge computing and embedded AI controllers
- Harsh‑environment industrial PCs requiring power continuity
### 5. Components & Accessories
Included Items (Standard Packing List):
1. PB‑4600J‑SA unit × 1
2. 3‑pin power terminal blocks × 2 (for DC input and output)
3. 10‑pin I/O terminal block × 1
4. DIN‑rail clip set (standard) / wall‑mount bracket (optional) × 1
5. DB9 (Female‑to‑Female) RS‑232 cable × 1
Front Panel Indicators and Controls:
- Charging Current Switch: Selectable 5 A or 10 A charging current.
- Supercapacitor Energy Level LEDs: Indicate 25 %, 50 %, 75 %, 100 % charge levels.
- Charging/Discharging Status LED: Orange (Charging), Red (Discharging).
- Reset Button: Recessed button for system reset and default configuration restore.
Side Panel I/O:
- RS‑232 COM Port (9‑pin D‑sub) for communication with host PC.
- 10‑pin I/O Terminal Block for PWR_BTN# and SYS_STAT signals.
### 6. Installation & Setup
Power Connection:
- Connect 12 – 35 V DC input to the 3‑pin terminal block (V+, GND, IGN_IN).
- Connect DC output (V+, GND, IGN_OUT) to the back‑end system’s power input.
- If input voltage ≥ 17 V, discharge output = 24 V; if < 17 V, output = 12 V.
Mounting Options:
- DIN‑rail mount for industrial cabinets.
- Wall‑mount bracket for fixed installations.
Configuration:
- Use the Power Backup Parameter Configurer software via RS‑232 to set operating mode, voltage thresholds, and shutdown delays.
- Windows systems should be configured to “Shut down” on power button press to enable controlled shutdown.
Charging Time (from 0 % to full):
- 5 A charging @ 24 V: 35 – 55 s
- 5 A charging @ 12 V: 60 – 110 s
- 10 A charging @ 24 V: 15 – 30 s
- 10 A charging @ 12 V: 25 – 45 s
Power Supply Requirements:
- ≥ 8 A for 5 A charging mode
- ≥ 13 A for 10 A charging mode
### 7. Performance & Capabilities
Energy Storage and Backup Duration:
- 4600 J energy capacity provides backup time depending on load:
- 0 – 50 W load: 130 – 680 s
- 50 – 100 W load: 60 – 130 s
- 100 – 150 W load: 30 – 60 s
- 150 – 200 W load: 15 – 30 s
Efficiency and Reliability:
- Instantaneous switch‑over to backup mode (< 1 ms).
- High charge/discharge efficiency due to low ESR supercapacitors.
- Automatic energy management prevents over‑voltage and deep discharge.
Limitations:
- Backup time reduces with higher load power consumption.
- At temperatures above 65 °C, energy capacity and lifespan may decrease without lifetime extension settings.
SuperCAP Lifetime Extension Settings (at 65 °C):
| Extension Factor | Energy Utilization (PB‑4600J‑SA) | Estimated Lifespan |
| 1× | 4600 J | 34,000 h |
| 1.5× | 4240 J | 51,000 h |
| 2.2× | 3890 J | 76,000 h |
| 3.3× | 3560 J | ≈ 10 years |
| 4.8× | 3245 J | ≈ 10 years |
### 8. Standards & Compliance
- EN50155: Certified for railway and transportation applications (vibration, shock, temperature).
- IEC 61373:2010: Category 1 Class B body‑mounted vibration and shock resistance.
- CE Marking: Complies with European Union directives for EMC and safety.
- FCC Class A: Conforms to Part 15 of FCC Rules for industrial environments.
- EN 55032 / EN 55035: Electromagnetic compatibility and immunity standards.
- RoHS Compliance: Lead‑free and environmentally safe components.
### 9. Additional Information
Warranty and Support:
- Covered under Neousys Technology’s standard hardware warranty policy.
- Firmware and software updates available via Neousys website or authorized service partners.
- Technical support available through regional offices in Taiwan, USA, and China.
Maintenance:
- Maintenance‑free operation (no battery replacement required).
- Periodic visual inspection recommended for connectors and mounting hardware.
- Only qualified personnel should service the unit.
Safety Precautions:
- Ensure correct input voltage (12 – 35 V DC).
- Install on a sturdy DIN rail or wall surface.
- Disconnect power before servicing or replacing components.
- Use anti‑static precautions when handling internal modules.
Manufacturer Contact Information:
- Neousys Technology Inc.
15F, No. 868‑3, Zhongzheng Rd., Zhonghe Dist., New Taipei City 23586, Taiwan
Tel: +886‑2‑2223‑6182 Fax: +886‑2‑2223‑6183
Email: sales@neousys‑tech.com Website: [www.neousys‑tech.com](https://www.neousys‑tech.com)
- Neousys Technology America Inc.
3384 Commercial Avenue, Northbrook, IL 60062, USA
Tel: +1‑847‑656‑3298 Email: sales@neousys‑tech.com
- Neousys Technology (China) Ltd.
Room 612, Building 32, Guiping Road 680, Shanghai, China
Tel: +86‑21‑61155366 Email: sales.cn@neousys‑tech.com
### Summary
The Neousys PB‑4600J‑SA is a compact, intelligent, and rugged supercapacitor‑based UPS module engineered for industrial and transportation computing systems. With 4600 J of energy storage, up to 100 W output power, and a wide temperature range, it ensures continuous operation and safe shutdown of connected devices during power interruptions. Its patented CAP Energy Management Technology provides precise energy control, automatic shutdown sequencing, and extended component lifespan. Certified to EN50155 and FCC/CE standards, the PB‑4600J‑SA is ideal for mission‑critical applications in industrial automation, railway systems, and in‑vehicle computing where reliability and durability are paramount.
### 1. Product Overview
Product Name: PB‑4600J‑SA
Article Number: PB‑4600J‑SA
Series: PB‑J‑SA Industrial Supercapacitor UPS Modules
Manufacturer: Neousys Technology Inc.
Product Type: Standalone intelligent supercapacitor‑based uninterruptible power backup module
Energy Capacity: 4600 J (watt‑seconds)
Patented Technology: CAP Energy Management Technology (R.O.C. Patent No. I598820)
Certification: EN50155 certified for railway and transportation applications
The Neousys PB‑4600J‑SA is a rugged, industrial‑grade, maintenance‑free power backup solution designed to protect embedded box‑PCs and industrial controllers from power interruptions. It employs high‑reliability supercapacitors instead of traditional batteries, offering extended service life, rapid charge/discharge capability, and wide‑temperature operation suitable for harsh environments.
### 2. Key Features
- Universal Compatibility: Works with virtually all industrial box‑PCs and embedded controllers without requiring proprietary drivers or software.
- Supercapacitor‑Based Energy Storage: Utilizes four 370 F / 3.0 V supercapacitors, providing 4600 J of stored energy for uninterruptible operation.
- Wide Operating Temperature: Reliable performance from –25 °C to +65 °C (up to 85 °C with reduced capacity).
- Long Service Life: Over 10 years of expected lifespan and 500,000 charge/discharge cycles.
- High Output Power: Delivers up to 100 W continuous output (180 W peak) to the connected system.
- Patented CAP Energy Management: Intelligent microcontroller‑based energy management ensures safe shutdown, optimized charge/discharge cycles, and extended capacitor life (up to 4.8× longer).
- Multiple Operating Modes:
- Normal Backup Mode – standard UPS‑like operation.
- Ignition Control Mode – for in‑vehicle systems requiring ignition‑based power sequencing.
- Ignition Relay Mode – relays ignition signals for transportation controllers.
- Automatic System Control: Supports automatic boot and shutdown via RS‑232 and isolated digital I/O (PWR_BTN# / SYS_STAT).
- Maintenance‑Free Operation: No battery replacement required; supercapacitors are solid‑state and environmentally friendly.
- Industrial Certifications: EN50155, CE, and FCC Class A compliance for vibration, shock, and EMC.
- Flexible Mounting: DIN‑rail and wall‑mount options for versatile installation.
- Compact Rugged Design: 82.5 mm (W) × 175.2 mm (H) × 128.2 mm (D), 1.68 kg aluminum chassis.
### 3. Technical Specifications
Supercapacitor Configuration
- Composition: 4 × 370 F / 3.0 V supercapacitors
- Energy Capacity: 4600 J (watt‑seconds)
- Expected Lifespan: > 10 years*
- Lifecycle: 500,000 charge/discharge cycles*
Electrical Characteristics
- Input Voltage: 12 – 35 V DC
- Input Connector: 1 × 3‑pin pluggable terminal block (V+, GND, IGN_IN)
- Output Voltage: 12 V or 24 V (software‑configurable during discharge)
- Output Power: Maximum 100 W continuous (up to 180 W peak)
- Output Connector: 1 × 3‑pin pluggable terminal block (V+, GND, IGN_OUT)
- I/O Interface:
- 1 × DB9 RS‑232 (3‑wire)
- 1 × 10‑pin pluggable terminal block for isolated DIO (PWR_BTN# output / SYS_STAT input)
Mechanical
- Dimensions: 82.5 mm (W) × 175.2 mm (H) × 128.2 mm (D)
- Weight: 1.68 kg
- Mounting: DIN‑rail and wall‑mount brackets
Environmental
- Operating Temperature: –25 °C to +65 °C (–40 °C to +85 °C with reduced capacity)
- Storage Temperature: –40 °C to +85 °C
- Vibration: IEC 61373:2010 Category 1 Class B (EN50155 compliant)
- Shock: IEC 61373:2010 Category 1 Class B (EN50155 compliant)
- EMC: EN50155:2007, CE/FCC Class A (EN 55032 & EN 55035)
\* To achieve > 10 years lifespan under 24/7 operation at 65 °C, charge to 3245 J energy level using 4.8× SuperCAP Lifetime Extension setting.
### 4. Functionality
The PB‑4600J‑SA functions as an intelligent, standalone uninterruptible power backup module. It continuously monitors input voltage and system status, charging its supercapacitors when external DC power is available. Upon power loss, it instantly switches to discharge mode, supplying regulated 12 V or 24 V DC to the connected system, ensuring uninterrupted operation and controlled shutdown.
Operating Modes:
1. Normal Backup Mode:
- Standard UPS operation for industrial PCs.
- Automatically charges when DC input is present.
- Provides backup power during outages and initiates safe shutdown via PWR_BTN# signal.
2. Ignition Control Mode:
- Designed for in‑vehicle controllers lacking native ignition control.
- Responds to IGN signal input to power on/off the system with user‑defined on/off delays.
3. Ignition Relay Mode:
- Passes ignition signals directly to the back‑end system.
- Suitable for transportation and automotive applications requiring synchronized ignition behavior.
Compatibility:
- Works with most off‑the‑shelf box‑PCs, embedded controllers, and industrial automation systems.
- Communicates via RS‑232 COM port and isolated digital I/O for system integration.
- No additional drivers or software required for basic operation.
Applications:
- Industrial automation and control systems
- Transportation and railway computing (EN50155 certified)
- In‑vehicle data acquisition and surveillance systems
- Edge computing and embedded AI controllers
- Harsh‑environment industrial PCs requiring power continuity
### 5. Components & Accessories
Included Items (Standard Packing List):
1. PB‑4600J‑SA unit × 1
2. 3‑pin power terminal blocks × 2 (for DC input and output)
3. 10‑pin I/O terminal block × 1
4. DIN‑rail clip set (standard) / wall‑mount bracket (optional) × 1
5. DB9 (Female‑to‑Female) RS‑232 cable × 1
Front Panel Indicators and Controls:
- Charging Current Switch: Selectable 5 A or 10 A charging current.
- Supercapacitor Energy Level LEDs: Indicate 25 %, 50 %, 75 %, 100 % charge levels.
- Charging/Discharging Status LED: Orange (Charging), Red (Discharging).
- Reset Button: Recessed button for system reset and default configuration restore.
Side Panel I/O:
- RS‑232 COM Port (9‑pin D‑sub) for communication with host PC.
- 10‑pin I/O Terminal Block for PWR_BTN# and SYS_STAT signals.
### 6. Installation & Setup
Power Connection:
- Connect 12 – 35 V DC input to the 3‑pin terminal block (V+, GND, IGN_IN).
- Connect DC output (V+, GND, IGN_OUT) to the back‑end system’s power input.
- If input voltage ≥ 17 V, discharge output = 24 V; if < 17 V, output = 12 V.
Mounting Options:
- DIN‑rail mount for industrial cabinets.
- Wall‑mount bracket for fixed installations.
Configuration:
- Use the Power Backup Parameter Configurer software via RS‑232 to set operating mode, voltage thresholds, and shutdown delays.
- Windows systems should be configured to “Shut down” on power button press to enable controlled shutdown.
Charging Time (from 0 % to full):
- 5 A charging @ 24 V: 35 – 55 s
- 5 A charging @ 12 V: 60 – 110 s
- 10 A charging @ 24 V: 15 – 30 s
- 10 A charging @ 12 V: 25 – 45 s
Power Supply Requirements:
- ≥ 8 A for 5 A charging mode
- ≥ 13 A for 10 A charging mode
### 7. Performance & Capabilities
Energy Storage and Backup Duration:
- 4600 J energy capacity provides backup time depending on load:
- 0 – 50 W load: 130 – 680 s
- 50 – 100 W load: 60 – 130 s
- 100 – 150 W load: 30 – 60 s
- 150 – 200 W load: 15 – 30 s
Efficiency and Reliability:
- Instantaneous switch‑over to backup mode (< 1 ms).
- High charge/discharge efficiency due to low ESR supercapacitors.
- Automatic energy management prevents over‑voltage and deep discharge.
Limitations:
- Backup time reduces with higher load power consumption.
- At temperatures above 65 °C, energy capacity and lifespan may decrease without lifetime extension settings.
SuperCAP Lifetime Extension Settings (at 65 °C):
| Extension Factor | Energy Utilization (PB‑4600J‑SA) | Estimated Lifespan |
| 1× | 4600 J | 34,000 h |
| 1.5× | 4240 J | 51,000 h |
| 2.2× | 3890 J | 76,000 h |
| 3.3× | 3560 J | ≈ 10 years |
| 4.8× | 3245 J | ≈ 10 years |
### 8. Standards & Compliance
- EN50155: Certified for railway and transportation applications (vibration, shock, temperature).
- IEC 61373:2010: Category 1 Class B body‑mounted vibration and shock resistance.
- CE Marking: Complies with European Union directives for EMC and safety.
- FCC Class A: Conforms to Part 15 of FCC Rules for industrial environments.
- EN 55032 / EN 55035: Electromagnetic compatibility and immunity standards.
- RoHS Compliance: Lead‑free and environmentally safe components.
### 9. Additional Information
Warranty and Support:
- Covered under Neousys Technology’s standard hardware warranty policy.
- Firmware and software updates available via Neousys website or authorized service partners.
- Technical support available through regional offices in Taiwan, USA, and China.
Maintenance:
- Maintenance‑free operation (no battery replacement required).
- Periodic visual inspection recommended for connectors and mounting hardware.
- Only qualified personnel should service the unit.
Safety Precautions:
- Ensure correct input voltage (12 – 35 V DC).
- Install on a sturdy DIN rail or wall surface.
- Disconnect power before servicing or replacing components.
- Use anti‑static precautions when handling internal modules.
Manufacturer Contact Information:
- Neousys Technology Inc.
15F, No. 868‑3, Zhongzheng Rd., Zhonghe Dist., New Taipei City 23586, Taiwan
Tel: +886‑2‑2223‑6182 Fax: +886‑2‑2223‑6183
Email: sales@neousys‑tech.com Website: [www.neousys‑tech.com](https://www.neousys‑tech.com)
- Neousys Technology America Inc.
3384 Commercial Avenue, Northbrook, IL 60062, USA
Tel: +1‑847‑656‑3298 Email: sales@neousys‑tech.com
- Neousys Technology (China) Ltd.
Room 612, Building 32, Guiping Road 680, Shanghai, China
Tel: +86‑21‑61155366 Email: sales.cn@neousys‑tech.com
### Summary
The Neousys PB‑4600J‑SA is a compact, intelligent, and rugged supercapacitor‑based UPS module engineered for industrial and transportation computing systems. With 4600 J of energy storage, up to 100 W output power, and a wide temperature range, it ensures continuous operation and safe shutdown of connected devices during power interruptions. Its patented CAP Energy Management Technology provides precise energy control, automatic shutdown sequencing, and extended component lifespan. Certified to EN50155 and FCC/CE standards, the PB‑4600J‑SA is ideal for mission‑critical applications in industrial automation, railway systems, and in‑vehicle computing where reliability and durability are paramount.
-
ds_pb-4600j-sa_pb-9250j-sa.pdf
PDF Catalog
No accessories available.