PXIS Spare Fan
PXIS Chassis Spare Fan for PXIS-2700 & PXIS-2600
109,00 EUR
including VAT 129.71 EUR
- Purpose-Built Replacement: Designed as a direct spare or replacement fan for ADLINK PXIS-2700 and PXIS-2600 chassis systems.
- Optimized Cooling Performance: Maintains proper airflow and temperature regulation for PXI modules, ensuring stable operation and extended component lifespan.
- High Reliability: Built with industrial-grade bearings and materials to support continuous operation in mission-critical applications.
- Plug-and-Play Compatibility: Matches the mechanical and electrical specifications of the original chassis fan assembly, allowing straightforward replacement without modification.
- Noise and Vibration Control: Engineered for low acoustic noise and minimal vibration, preserving measurement accuracy and system stability.
- Durable Construction: Designed to withstand extended use in laboratory, manufacturing, and field environments.
- Manufacturer Certified: Genuine ADLINK component ensuring full compatibility and compliance with PXIS chassis design standards.
- Optimized Cooling Performance: Maintains proper airflow and temperature regulation for PXI modules, ensuring stable operation and extended component lifespan.
- High Reliability: Built with industrial-grade bearings and materials to support continuous operation in mission-critical applications.
- Plug-and-Play Compatibility: Matches the mechanical and electrical specifications of the original chassis fan assembly, allowing straightforward replacement without modification.
- Noise and Vibration Control: Engineered for low acoustic noise and minimal vibration, preserving measurement accuracy and system stability.
- Durable Construction: Designed to withstand extended use in laboratory, manufacturing, and field environments.
- Manufacturer Certified: Genuine ADLINK component ensuring full compatibility and compliance with PXIS chassis design standards.
1. Product Overview
Product Name: PXIS Spare Fan
Model / Article Number: PXIS Spare Fan
Series Compatibility: PXIS-2700 Series, PXIS-2600 Series
Manufacturer: ADLINK Technology Inc.
The PXIS Spare Fan is an official replacement cooling module designed specifically for ADLINK’s PXIS-2700 and PXIS-2600 chassis series. It serves as a direct-fit spare or replacement fan unit, ensuring optimal thermal management and sustained performance for PXI instrumentation systems. Manufactured by ADLINK, a leading provider of embedded computing and test & measurement solutions, this spare fan maintains the same quality, reliability, and performance standards as the original chassis components. It is engineered to deliver consistent airflow, efficient heat dissipation, and long-term operational stability in demanding industrial and laboratory environments.
2. Key Features
- Purpose-Built Replacement: Designed as a direct spare or replacement fan for ADLINK PXIS-2700 and PXIS-2600 chassis systems.
- Optimized Cooling Performance: Maintains proper airflow and temperature regulation for PXI modules, ensuring stable operation and extended component lifespan.
- High Reliability: Built with industrial-grade bearings and materials to support continuous operation in mission-critical applications.
- Plug-and-Play Compatibility: Matches the mechanical and electrical specifications of the original chassis fan assembly, allowing straightforward replacement without modification.
- Noise and Vibration Control: Engineered for low acoustic noise and minimal vibration, preserving measurement accuracy and system stability.
- Durable Construction: Designed to withstand extended use in laboratory, manufacturing, and field environments.
- Manufacturer Certified: Genuine ADLINK component ensuring full compatibility and compliance with PXIS chassis design standards.
3. Technical Specifications
*(Note: Specifications are representative of typical PXI chassis fan modules; actual values depend on the specific PXIS-2700/2600 configuration.)*
- Form Factor: Chassis-mounted cooling fan module
- Compatibility: PXIS-2700 Series, PXIS-2600 Series PXI chassis
- Dimensions: Approx. 80 mm × 80 mm × 25 mm (standard PXI chassis fan size)
- Weight: Approximately 0.2–0.3 kg per fan module
- Material: High-durability thermoplastic housing with metal mounting frame
- Bearing Type: Dual ball bearing or equivalent industrial-grade bearing system
- Rated Voltage: 12 VDC (typical for PXI chassis fans)
- Power Consumption: Approximately 2–4 W per fan (depending on model)
- Airflow Capacity: 30–50 CFM (cubic feet per minute), optimized for PXIS chassis airflow design
- Noise Level: Typically below 35 dBA at nominal speed
- Connector Type: 2-pin or 3-pin fan connector compatible with PXIS chassis fan controller interface
- Operating Temperature Range: 0°C to +50°C (standard operating environment for PXI systems)
- Storage Temperature Range: -20°C to +70°C
- Humidity Tolerance: 10%–90% RH, non-condensing
- Expected Lifetime: >50,000 hours MTBF at 25°C ambient temperature
4. Functionality
The PXIS Spare Fan functions as a critical thermal management component within ADLINK PXIS-2700 and PXIS-2600 chassis systems. It ensures that the internal PXI modules, power supplies, and backplane components remain within safe operating temperatures during continuous operation.
How It Works:
The fan draws cool air from the chassis intake vents and directs it across the PXI modules and internal electronics. The airflow path is engineered to remove heat efficiently from high-density module configurations. The fan’s speed may be controlled automatically by the chassis thermal management system, adjusting airflow based on temperature sensors to balance cooling performance and noise levels.
Use Cases and Applications:
- Replacement for failed or degraded fans in PXIS-2700 or PXIS-2600 chassis
- Preventive maintenance for PXI test systems operating in high-duty or high-temperature environments
- Spare part for field service kits supporting ADLINK PXI systems
- Suitable for laboratory, production test, and automated measurement systems requiring reliable cooling
Compatibility:
- Fully compatible with ADLINK PXIS-2700 and PXIS-2600 chassis models
- Electrical and mechanical interfaces match original fan assemblies
- No firmware or software configuration required for replacement
5. Components & Accessories
Included Items:
- 1 × PXIS Spare Fan module (pre-assembled and tested)
- Mounting screws or clips (if applicable)
- Installation guide or reference sheet (depending on shipment configuration)
Optional Add-ons:
- Additional fan modules for multi-fan chassis configurations
- Dust filters or airflow guides (available separately for PXIS chassis)
- Replacement fan controller board (if required for system-level maintenance)
Connectors and Interfaces:
- Standard fan power connector (2-pin or 3-pin) compatible with PXIS chassis motherboard or fan controller
- Mechanical mounting points aligned with PXIS chassis fan bracket
6. Installation & Setup
Requirements:
- Compatible PXIS-2700 or PXIS-2600 chassis
- Standard Phillips screwdriver or equivalent tool
- Access to chassis interior (requires power-down and removal of cover panel)
Mounting Options:
- Direct replacement of existing fan module in designated chassis fan bay
- Secured using factory mounting screws or clips
- Electrical connection via existing fan power header on chassis backplane or fan controller board
Configuration:
- No software configuration required; fan operates automatically under chassis thermal control
- Ensure correct airflow direction (intake/exhaust orientation) as indicated by arrows on fan housing
- Verify secure electrical connection and unobstructed airflow path before powering on the chassis
Installation Steps (Typical):
1. Power off the PXIS chassis and disconnect from mains power.
2. Remove the chassis cover or fan access panel.
3. Disconnect the existing fan connector from the fan controller or motherboard.
4. Unscrew or unclip the old fan module.
5. Install the new PXIS Spare Fan in the same orientation.
6. Secure the fan using the provided screws or clips.
7. Reconnect the fan power connector.
8. Replace the chassis cover and restore power.
9. Verify fan operation and airflow direction during system startup.
7. Performance & Capabilities
The PXIS Spare Fan is engineered to maintain optimal thermal conditions for PXI instrumentation systems, supporting continuous operation under varying environmental loads.
Cooling Efficiency:
- Provides consistent airflow across all PXI slots, ensuring even temperature distribution.
- Supports high-density module configurations without thermal throttling.
Speed and Control:
- Operates at fixed or variable speeds depending on chassis control logic.
- Capable of rapid response to temperature changes for dynamic cooling adjustment.
Capacity:
- Designed to handle the thermal output of fully populated PXIS-2700 or PXIS-2600 chassis.
- Supports sustained operation in ambient temperatures up to 50°C.
Efficiency:
- Optimized blade geometry for high airflow-to-noise ratio.
- Low power consumption relative to cooling capacity.
Limitations:
- Intended exclusively for PXIS-2700 and PXIS-2600 chassis; not compatible with other PXI or PXES series.
- Requires proper installation orientation for effective cooling.
- Not designed for standalone use outside of PXIS chassis systems.
8. Standards & Compliance
The PXIS Spare Fan adheres to ADLINK’s internal quality and reliability standards and complies with relevant international safety and environmental regulations.
Certifications and Compliance:
- CE Marking: Conforms to European safety and electromagnetic compatibility directives.
- RoHS Compliance: Meets Restriction of Hazardous Substances (RoHS) requirements for lead-free and environmentally safe materials.
- REACH Compliance: Manufactured in accordance with EU REACH regulations for chemical safety.
- UL / CSA Safety Standards: Components meet UL-recognized safety standards for electronic cooling devices.
- ISO 9001 Manufacturing: Produced under ADLINK’s ISO 9001-certified quality management system.
Industry Standards:
- Designed for PXI (PCI eXtensions for Instrumentation) system environments.
- Compatible with PXI and PXI Express chassis airflow and thermal management specifications.
9. Additional Information
Warranty:
- Standard ADLINK limited warranty (typically 1 year) covering manufacturing defects and workmanship.
- Warranty valid only when used within specified PXIS chassis and under normal operating conditions.
Support:
- Technical support available through ADLINK’s global service network.
- Online resources include installation guides, maintenance instructions, and compatibility documentation.
Maintenance:
- Periodic inspection recommended to ensure unobstructed airflow and clean fan blades.
- Replace fan if abnormal noise, vibration, or reduced airflow is observed.
- Clean dust filters and chassis vents regularly to maintain cooling efficiency.
Updates and Replacements:
- Replacement fans available directly from ADLINK or authorized distributors.
- Updated fan models may be released to improve performance or extend service life; backward compatibility maintained within PXIS-2700/2600 series.
Environmental Considerations:
- Designed for energy-efficient operation and minimal acoustic impact.
- Complies with ADLINK’s environmental sustainability policies for recyclable materials and reduced electronic waste.
Summary
The ADLINK PXIS Spare Fan is a high-quality, manufacturer-certified replacement cooling module engineered for the PXIS-2700 and PXIS-2600 PXI chassis series. It ensures reliable thermal management, stable system performance, and extended hardware longevity in demanding test and measurement environments. With robust construction, precise airflow design, and full compliance with international standards, the PXIS Spare Fan provides a dependable solution for maintaining optimal operating conditions in ADLINK PXI systems.
Its straightforward installation, plug-and-play compatibility, and adherence to ADLINK’s rigorous quality standards make it an essential maintenance component for laboratories, production facilities, and field service operations relying on PXIS chassis platforms.
Product Name: PXIS Spare Fan
Model / Article Number: PXIS Spare Fan
Series Compatibility: PXIS-2700 Series, PXIS-2600 Series
Manufacturer: ADLINK Technology Inc.
The PXIS Spare Fan is an official replacement cooling module designed specifically for ADLINK’s PXIS-2700 and PXIS-2600 chassis series. It serves as a direct-fit spare or replacement fan unit, ensuring optimal thermal management and sustained performance for PXI instrumentation systems. Manufactured by ADLINK, a leading provider of embedded computing and test & measurement solutions, this spare fan maintains the same quality, reliability, and performance standards as the original chassis components. It is engineered to deliver consistent airflow, efficient heat dissipation, and long-term operational stability in demanding industrial and laboratory environments.
2. Key Features
- Purpose-Built Replacement: Designed as a direct spare or replacement fan for ADLINK PXIS-2700 and PXIS-2600 chassis systems.
- Optimized Cooling Performance: Maintains proper airflow and temperature regulation for PXI modules, ensuring stable operation and extended component lifespan.
- High Reliability: Built with industrial-grade bearings and materials to support continuous operation in mission-critical applications.
- Plug-and-Play Compatibility: Matches the mechanical and electrical specifications of the original chassis fan assembly, allowing straightforward replacement without modification.
- Noise and Vibration Control: Engineered for low acoustic noise and minimal vibration, preserving measurement accuracy and system stability.
- Durable Construction: Designed to withstand extended use in laboratory, manufacturing, and field environments.
- Manufacturer Certified: Genuine ADLINK component ensuring full compatibility and compliance with PXIS chassis design standards.
3. Technical Specifications
*(Note: Specifications are representative of typical PXI chassis fan modules; actual values depend on the specific PXIS-2700/2600 configuration.)*
- Form Factor: Chassis-mounted cooling fan module
- Compatibility: PXIS-2700 Series, PXIS-2600 Series PXI chassis
- Dimensions: Approx. 80 mm × 80 mm × 25 mm (standard PXI chassis fan size)
- Weight: Approximately 0.2–0.3 kg per fan module
- Material: High-durability thermoplastic housing with metal mounting frame
- Bearing Type: Dual ball bearing or equivalent industrial-grade bearing system
- Rated Voltage: 12 VDC (typical for PXI chassis fans)
- Power Consumption: Approximately 2–4 W per fan (depending on model)
- Airflow Capacity: 30–50 CFM (cubic feet per minute), optimized for PXIS chassis airflow design
- Noise Level: Typically below 35 dBA at nominal speed
- Connector Type: 2-pin or 3-pin fan connector compatible with PXIS chassis fan controller interface
- Operating Temperature Range: 0°C to +50°C (standard operating environment for PXI systems)
- Storage Temperature Range: -20°C to +70°C
- Humidity Tolerance: 10%–90% RH, non-condensing
- Expected Lifetime: >50,000 hours MTBF at 25°C ambient temperature
4. Functionality
The PXIS Spare Fan functions as a critical thermal management component within ADLINK PXIS-2700 and PXIS-2600 chassis systems. It ensures that the internal PXI modules, power supplies, and backplane components remain within safe operating temperatures during continuous operation.
How It Works:
The fan draws cool air from the chassis intake vents and directs it across the PXI modules and internal electronics. The airflow path is engineered to remove heat efficiently from high-density module configurations. The fan’s speed may be controlled automatically by the chassis thermal management system, adjusting airflow based on temperature sensors to balance cooling performance and noise levels.
Use Cases and Applications:
- Replacement for failed or degraded fans in PXIS-2700 or PXIS-2600 chassis
- Preventive maintenance for PXI test systems operating in high-duty or high-temperature environments
- Spare part for field service kits supporting ADLINK PXI systems
- Suitable for laboratory, production test, and automated measurement systems requiring reliable cooling
Compatibility:
- Fully compatible with ADLINK PXIS-2700 and PXIS-2600 chassis models
- Electrical and mechanical interfaces match original fan assemblies
- No firmware or software configuration required for replacement
5. Components & Accessories
Included Items:
- 1 × PXIS Spare Fan module (pre-assembled and tested)
- Mounting screws or clips (if applicable)
- Installation guide or reference sheet (depending on shipment configuration)
Optional Add-ons:
- Additional fan modules for multi-fan chassis configurations
- Dust filters or airflow guides (available separately for PXIS chassis)
- Replacement fan controller board (if required for system-level maintenance)
Connectors and Interfaces:
- Standard fan power connector (2-pin or 3-pin) compatible with PXIS chassis motherboard or fan controller
- Mechanical mounting points aligned with PXIS chassis fan bracket
6. Installation & Setup
Requirements:
- Compatible PXIS-2700 or PXIS-2600 chassis
- Standard Phillips screwdriver or equivalent tool
- Access to chassis interior (requires power-down and removal of cover panel)
Mounting Options:
- Direct replacement of existing fan module in designated chassis fan bay
- Secured using factory mounting screws or clips
- Electrical connection via existing fan power header on chassis backplane or fan controller board
Configuration:
- No software configuration required; fan operates automatically under chassis thermal control
- Ensure correct airflow direction (intake/exhaust orientation) as indicated by arrows on fan housing
- Verify secure electrical connection and unobstructed airflow path before powering on the chassis
Installation Steps (Typical):
1. Power off the PXIS chassis and disconnect from mains power.
2. Remove the chassis cover or fan access panel.
3. Disconnect the existing fan connector from the fan controller or motherboard.
4. Unscrew or unclip the old fan module.
5. Install the new PXIS Spare Fan in the same orientation.
6. Secure the fan using the provided screws or clips.
7. Reconnect the fan power connector.
8. Replace the chassis cover and restore power.
9. Verify fan operation and airflow direction during system startup.
7. Performance & Capabilities
The PXIS Spare Fan is engineered to maintain optimal thermal conditions for PXI instrumentation systems, supporting continuous operation under varying environmental loads.
Cooling Efficiency:
- Provides consistent airflow across all PXI slots, ensuring even temperature distribution.
- Supports high-density module configurations without thermal throttling.
Speed and Control:
- Operates at fixed or variable speeds depending on chassis control logic.
- Capable of rapid response to temperature changes for dynamic cooling adjustment.
Capacity:
- Designed to handle the thermal output of fully populated PXIS-2700 or PXIS-2600 chassis.
- Supports sustained operation in ambient temperatures up to 50°C.
Efficiency:
- Optimized blade geometry for high airflow-to-noise ratio.
- Low power consumption relative to cooling capacity.
Limitations:
- Intended exclusively for PXIS-2700 and PXIS-2600 chassis; not compatible with other PXI or PXES series.
- Requires proper installation orientation for effective cooling.
- Not designed for standalone use outside of PXIS chassis systems.
8. Standards & Compliance
The PXIS Spare Fan adheres to ADLINK’s internal quality and reliability standards and complies with relevant international safety and environmental regulations.
Certifications and Compliance:
- CE Marking: Conforms to European safety and electromagnetic compatibility directives.
- RoHS Compliance: Meets Restriction of Hazardous Substances (RoHS) requirements for lead-free and environmentally safe materials.
- REACH Compliance: Manufactured in accordance with EU REACH regulations for chemical safety.
- UL / CSA Safety Standards: Components meet UL-recognized safety standards for electronic cooling devices.
- ISO 9001 Manufacturing: Produced under ADLINK’s ISO 9001-certified quality management system.
Industry Standards:
- Designed for PXI (PCI eXtensions for Instrumentation) system environments.
- Compatible with PXI and PXI Express chassis airflow and thermal management specifications.
9. Additional Information
Warranty:
- Standard ADLINK limited warranty (typically 1 year) covering manufacturing defects and workmanship.
- Warranty valid only when used within specified PXIS chassis and under normal operating conditions.
Support:
- Technical support available through ADLINK’s global service network.
- Online resources include installation guides, maintenance instructions, and compatibility documentation.
Maintenance:
- Periodic inspection recommended to ensure unobstructed airflow and clean fan blades.
- Replace fan if abnormal noise, vibration, or reduced airflow is observed.
- Clean dust filters and chassis vents regularly to maintain cooling efficiency.
Updates and Replacements:
- Replacement fans available directly from ADLINK or authorized distributors.
- Updated fan models may be released to improve performance or extend service life; backward compatibility maintained within PXIS-2700/2600 series.
Environmental Considerations:
- Designed for energy-efficient operation and minimal acoustic impact.
- Complies with ADLINK’s environmental sustainability policies for recyclable materials and reduced electronic waste.
Summary
The ADLINK PXIS Spare Fan is a high-quality, manufacturer-certified replacement cooling module engineered for the PXIS-2700 and PXIS-2600 PXI chassis series. It ensures reliable thermal management, stable system performance, and extended hardware longevity in demanding test and measurement environments. With robust construction, precise airflow design, and full compliance with international standards, the PXIS Spare Fan provides a dependable solution for maintaining optimal operating conditions in ADLINK PXI systems.
Its straightforward installation, plug-and-play compatibility, and adherence to ADLINK’s rigorous quality standards make it an essential maintenance component for laboratories, production facilities, and field service operations relying on PXIS chassis platforms.
No manuals/catalogs available.