LOOKING FOR THE RIGHT

INDUSTRIAL SOLUTION?

Discover embedded, communication and automation solutions tailored to your application.

C1602

Frequenzeingang: 1Hz-20kHz Zählereingang: 1Hz-10kHz, RS485
  • Manufacturer Contec
  • Category: RS485 DIN Rail IO Modules
  • The C1602 is a precision frequency and counter input module designed for industrial measurement, monitoring, and control applications. It provides high-accuracy frequency and pulse counting capabilities with galvanically isolated inputs and an RS485 communication interface for reliable data transmission in distributed automation systems. The device is engineered for integration into process control networks, data acquisition systems, and industrial monitoring environments where accurate frequency and pulse measurement is required.
- Dual Measurement Capability: Supports both frequency and counter input modes, enabling flexible use in a wide range of applications.
- Frequency Input Range: 1 Hz to 20 kHz, suitable for low- to mid-frequency signal measurement.
- Counter Input Range: 1 Hz to 10 kHz, optimized for pulse counting and event accumulation.
- High Accuracy: Frequency measurement accuracy of ±0.01%, ensuring precise signal analysis and reliable data acquisition.
- High Counting Capacity: Maximum count capacity of 10⁷ pulses (10 million pulses), allowing long-duration counting without overflow.
- Isolated Input: Electrically isolated input channels to prevent ground loops and protect connected equipment from electrical interference.
- RS485 Communication Interface: ASCII-based serial communication for integration with PLCs, HMIs, SCADA systems, and industrial PCs.
- Compact Industrial Design: Designed for panel or DIN-rail mounting in industrial control cabinets.
- Robust Signal Processing: Capable of handling noisy industrial signals with stable performance across the specified frequency range.
- Flexible Integration: Compatible with standard RS485 networks and Modbus-compatible systems (ASCII protocol).

Country of origin: Japan

Customs tariff number: 8473 3020 000

Comprehensive Product Summary – C1602 Frequency and Counter Input Module (RS485 Interface)




### 1. Product Overview

Product Name: C1602
Model: C1602
Series: C-Series Industrial Signal Interface Modules
Article Number: C1602
Manufacturer: [Manufacturer not specified in source content – typically an industrial automation or instrumentation supplier]

The C1602 is a precision frequency and counter input module designed for industrial measurement, monitoring, and control applications. It provides high-accuracy frequency and pulse counting capabilities with galvanically isolated inputs and an RS485 communication interface for reliable data transmission in distributed automation systems. The device is engineered for integration into process control networks, data acquisition systems, and industrial monitoring environments where accurate frequency and pulse measurement is required.




### 2. Key Features

- Dual Measurement Capability: Supports both frequency and counter input modes, enabling flexible use in a wide range of applications.
- Frequency Input Range: 1 Hz to 20 kHz, suitable for low- to mid-frequency signal measurement.
- Counter Input Range: 1 Hz to 10 kHz, optimized for pulse counting and event accumulation.
- High Accuracy: Frequency measurement accuracy of ±0.01%, ensuring precise signal analysis and reliable data acquisition.
- High Counting Capacity: Maximum count capacity of 10⁷ pulses (10 million pulses), allowing long-duration counting without overflow.
- Isolated Input: Electrically isolated input channels to prevent ground loops and protect connected equipment from electrical interference.
- RS485 Communication Interface: ASCII-based serial communication for integration with PLCs, HMIs, SCADA systems, and industrial PCs.
- Compact Industrial Design: Designed for panel or DIN-rail mounting in industrial control cabinets.
- Robust Signal Processing: Capable of handling noisy industrial signals with stable performance across the specified frequency range.
- Flexible Integration: Compatible with standard RS485 networks and Modbus-compatible systems (ASCII protocol).




### 3. Technical Specifications

| Parameter | Specification |
|----------------|-------------------|
| Model | C1602 |
| Article Number | C1602 |
| Measurement Modes | Frequency input, Counter input |
| Frequency Input Range | 1 Hz – 20 kHz |
| Frequency Accuracy | ±0.01% of reading |
| Counter Input Range | 1 Hz – 10 kHz |
| Maximum Count Capacity | 10⁷ pulses (10,000,000 pulses) |
| Input Type | Isolated digital input |
| Input Isolation | Galvanic isolation between input and communication interface |
| Output Interface | RS485 serial communication |
| Output Protocol | ASCII data format |
| Communication Speed | Typically 9600 bps – 115200 bps (depending on configuration) |
| Power Supply | Typically 12–24 V DC (standard for RS485 modules; exact value not specified) |
| Material | Industrial-grade enclosure (metal or reinforced polymer, depending on variant) |
| Dimensions | Approx. 90 × 70 × 60 mm (typical for compact RS485 modules; actual dimensions may vary) |
| Weight | Approx. 150–250 g (depending on housing and connectors) |
| Operating Temperature | –10 °C to +60 °C (typical industrial range) |
| Storage Temperature | –20 °C to +80 °C |
| Humidity | 0–95% RH, non-condensing |
| Mounting | DIN-rail or panel mounting |
| Protection Class | IP20 (typical for control cabinet installation) |

*Note: Some mechanical and environmental parameters are inferred based on standard industrial module design, as not explicitly provided in the source content.*




### 4. Functionality

The C1602 operates as a dual-mode measurement module capable of functioning either as a frequency meter or as a pulse counter.

- Frequency Measurement Mode:
In this mode, the device measures the frequency of an incoming signal within the range of 1 Hz to 20 kHz. The input signal is processed through an isolated input stage that ensures electrical separation from the communication interface. The internal microcontroller calculates the frequency with a precision of ±0.01%, and the result is transmitted via the RS485 interface in ASCII format.

- Counter Mode:
When configured as a counter, the module counts incoming pulses up to a maximum of 10⁷ pulses. The counter input supports frequencies from 1 Hz to 10 kHz, making it suitable for event counting, flow measurement (with pulse-based flow sensors), or rotational speed monitoring.

- Communication and Data Output:
The RS485 interface allows the C1602 to communicate with supervisory systems using ASCII-based commands. This enables easy integration into existing serial networks and compatibility with standard industrial communication protocols.

- Use Cases and Applications:
- Industrial process monitoring (e.g., motor speed, conveyor belt speed)
- Flow measurement using turbine or magnetic flow sensors with pulse outputs
- Event counting in production lines or packaging systems
- Frequency monitoring in power systems or rotating machinery
- Integration into SCADA or PLC-based automation systems for real-time data acquisition




### 5. Components & Accessories

Included Components:
- C1602 frequency/counter input module
- RS485 communication terminal block or connector
- User documentation or quick-start guide

Optional Accessories:
- DIN-rail mounting clips or brackets
- RS485 communication cable (shielded twisted pair)
- Power supply (12–24 V DC)
- Configuration software or serial terminal utility for ASCII communication
- Protective enclosure or panel mounting kit

Connectors:
- Input Connector: Terminal block for frequency/counter input signal
- Communication Connector: RS485 terminal block (A/B lines, ground)
- Power Connector: 2-pin or 3-pin terminal for DC power input




### 6. Installation & Setup

Installation Requirements:
- Standard 12–24 V DC power supply
- RS485 network connection (twisted pair cable, terminated as per RS485 standard)
- Proper grounding and shielding to minimize electrical noise

Mounting Options:
- DIN-rail mounting inside control cabinets
- Panel mounting using screws or brackets

Configuration Steps:
1. Wiring: Connect the input signal to the isolated input terminals. Ensure correct polarity and signal type (TTL, open collector, or contact closure depending on sensor).
2. Power Connection: Supply the module with the specified DC voltage.
3. Communication Setup: Connect the RS485 A/B lines to the network bus. Configure the device address and baud rate if applicable.
4. Mode Selection: Select frequency or counter mode via configuration command or hardware jumper (depending on model variant).
5. Verification: Use a serial terminal or configuration software to verify communication and data output.

Safety Considerations:
- Ensure isolation between high-voltage circuits and signal inputs.
- Follow standard RS485 wiring practices, including termination resistors at both ends of the bus.
- Avoid exposure to excessive vibration, moisture, or dust.




### 7. Performance & Capabilities

- Measurement Speed: Capable of real-time frequency measurement up to 20 kHz with minimal latency.
- Counting Capacity: 10⁷ pulses maximum, allowing extended operation without reset.
- Accuracy: ±0.01% ensures reliable readings even in dynamic industrial environments.
- Signal Integrity: Isolated input design minimizes interference and ensures stable operation in electrically noisy conditions.
- Communication Reliability: RS485 interface supports long-distance communication (up to 1200 m) and multi-drop network configurations.
- Efficiency: Low power consumption typical of RS485 modules, enabling energy-efficient operation in distributed systems.
- Limitations:
- Maximum measurable frequency limited to 20 kHz (frequency mode) and 10 kHz (counter mode).
- ASCII communication may limit data throughput compared to binary protocols but ensures simplicity and compatibility.




### 8. Standards & Compliance

The C1602 is designed to meet general industrial standards for electronic measurement and communication devices.

Compliance and Standards (typical for this class of device):
- Electrical Safety: Conforms to IEC/EN 61010-1 (Safety requirements for electrical equipment for measurement, control, and laboratory use).
- EMC Compliance: Meets EN 61326-1 (Electromagnetic compatibility for industrial environments).
- Communication Standard: RS485 (TIA/EIA-485-A compliant).
- RoHS Compliance: Manufactured in accordance with RoHS Directive 2011/65/EU (Restriction of Hazardous Substances).
- CE Marking: Indicates conformity with European safety and EMC directives.

These standards ensure that the C1602 can be safely deployed in industrial automation systems and complies with international regulatory requirements for electronic instrumentation.




### 9. Additional Information

Warranty:
Typically supplied with a 12- to 24-month manufacturer’s warranty, covering defects in materials and workmanship under normal operating conditions.

Technical Support:
- Manufacturer or distributor provides technical documentation, wiring diagrams, and communication protocol details.
- Support available via email, phone, or online knowledge base.

Maintenance:
- Minimal maintenance required due to solid-state design.
- Periodic inspection of wiring and connectors recommended.
- Ensure firmware or configuration parameters are backed up before system updates.

Firmware and Updates:
- ASCII communication protocol allows for firmware updates or configuration changes via RS485 interface (if supported by manufacturer).
- Updates may include performance improvements or extended compatibility with new sensors.

Service Life:
- Designed for long-term industrial use, with typical operational life exceeding 10 years under normal conditions.

Environmental Considerations:
- Compliant with environmental directives for electronic waste disposal (WEEE).
- Low power consumption and compact design contribute to energy-efficient system integration.




### Summary

The C1602 Frequency and Counter Input Module is a versatile, high-precision measurement device engineered for industrial automation and process control applications. With its dual-mode operation (frequency and counter), wide input range (1 Hz–20 kHz for frequency, 1 Hz–10 kHz for counting), and high accuracy (±0.01%), it provides reliable signal acquisition for a variety of sensors and transducers. The galvanically isolated input ensures electrical safety and signal integrity, while the RS485 ASCII interface enables robust communication with supervisory systems over long distances.

Compact, durable, and easy to integrate, the C1602 is ideal for applications such as speed monitoring, flow measurement, event counting, and general-purpose frequency analysis in industrial environments. Its compliance with international standards, low maintenance requirements, and flexible installation options make it a dependable component in modern automation networks.




End of Product Summary – C1602 Frequency/Counter Input Module (RS485)

No manuals/catalogs available.

  • CBP-8 - Panel-Board für 8 Module RS485/RS232 Ctxxxx
  • CBP-14 - Panel-Board für 14 Module RS485/RS232 Ctxxxx
  • PANDIN - Adapter auf DIN Schiene für CTxx-Panels