IES-A3062GF-MM-SC

Oil&Gas Ind. Managed Switch 2*1000FX MM 6*100TX C1D2 ATEX
  • Manufacturer Oring
  • Category: Oil & Gas (C1D2 Approved)
  • The IES-A3062GF-MM-SC is a rugged, managed industrial Ethernet switch designed for Oil & Gas and other hazardous environments requiring C1D2 and ATEX Class 1 Zone 2 compliance. It belongs to ORing’s IES-A3 Series, engineered for high reliability, network redundancy, and advanced management in mission-critical industrial networks.
- Industrial-Grade Managed Switch: Designed for hazardous environments with C1D2/ATEX certification.
- Port Configuration:
- 6 × 10/100Base‑T(X) RJ‑45 ports (Auto MDI/MDI‑X)
- 2 × 1000Base‑X Gigabit fiber ports (Multi‑Mode SC connectors)
- High Availability & Redundancy:
- O‑Ring technology with recovery time <10 ms over 250 nodes
- Open‑Ring, O‑Chain, Dual Homing, and Coupling Ring support
- STP/RSTP/MSTP (IEEE 802.1D/w/s) and IEC 62439‑2 MRP
- Network Management:
- Web GUI, Telnet, Console (CLI), SNMP v1/v2c/v3, and ORing’s Open‑Vision centralized management utility
- Supports RMON, LLDP, QoS (802.1p), VLAN (802.1Q, QinQ), and IGMP Snooping
- Security:
- 802.1X port-based access control, MAC-based port security, IP security lists, SNMPv3 authentication, and RADIUS integration
- Time Synchronization:
- PTP Client (IEEE 1588) and SNTP for precise clock synchronization
- Event Notification:
- Syslog, SMTP (email alerts), SNMP traps, and relay output for fault indication
- Power System:
- Triple redundant DC inputs (12–48 VDC) with reverse polarity protection
- Environmental Robustness:
- Operating temperature: –40 °C to +70 °C
- IP‑30 metal enclosure, DIN‑rail and wall‑mountable
- Warranty: 5 years standard manufacturer warranty

Country of origin: Taiwan R.O.C.

Customs tariff number: 8517 6200 900

Comprehensive Product Summary – ORing IES-A3062GF-MM-SC Industrial Managed Switch




### 1. Product Overview

Product Name: ORing IES-A3062GF-MM-SC
Article Number: IES-A3062GF-MM-SC
Series: IES-A3 Series – Industrial Managed Ethernet Switches
Manufacturer: ORing Industrial Networking Corp.
Manufacturer Address: 3F, 542-2 Zhongzheng Road, Xindian District, New Taipei City 231, Taiwan
Website: [www.oring-networking.com](http://www.oring-networking.com)
Contact: Tel: +886-2-2218-1066 | Fax: +886-2-2218-1014 | Email: support@oring-networking.com

The IES-A3062GF-MM-SC is a rugged, managed industrial Ethernet switch designed for Oil & Gas and other hazardous environments requiring C1D2 and ATEX Class 1 Zone 2 compliance. It belongs to ORing’s IES-A3 Series, engineered for high reliability, network redundancy, and advanced management in mission-critical industrial networks.




### 2. Key Features

- Industrial-Grade Managed Switch: Designed for hazardous environments with C1D2/ATEX certification.
- Port Configuration:
- 6 × 10/100Base‑T(X) RJ‑45 ports (Auto MDI/MDI‑X)
- 2 × 1000Base‑X Gigabit fiber ports (Multi‑Mode SC connectors)
- High Availability & Redundancy:
- O‑Ring technology with recovery time <10 ms over 250 nodes
- Open‑Ring, O‑Chain, Dual Homing, and Coupling Ring support
- STP/RSTP/MSTP (IEEE 802.1D/w/s) and IEC 62439‑2 MRP
- Network Management:
- Web GUI, Telnet, Console (CLI), SNMP v1/v2c/v3, and ORing’s Open‑Vision centralized management utility
- Supports RMON, LLDP, QoS (802.1p), VLAN (802.1Q, QinQ), and IGMP Snooping
- Security:
- 802.1X port-based access control, MAC-based port security, IP security lists, SNMPv3 authentication, and RADIUS integration
- Time Synchronization:
- PTP Client (IEEE 1588) and SNTP for precise clock synchronization
- Event Notification:
- Syslog, SMTP (email alerts), SNMP traps, and relay output for fault indication
- Power System:
- Triple redundant DC inputs (12–48 VDC) with reverse polarity protection
- Environmental Robustness:
- Operating temperature: –40 °C to +70 °C
- IP‑30 metal enclosure, DIN‑rail and wall‑mountable
- Warranty: 5 years standard manufacturer warranty




### 3. Technical Specifications

Ethernet Standards:
IEEE 802.3 (10Base‑T), 802.3u (100Base‑TX/FX), 802.3z (1000Base‑SX/LX), 802.3ab (1000Base‑T), 802.3ad (LACP), 802.3x (Flow Control), 802.1D (STP), 802.1p (CoS), 802.1Q (VLAN), 802.1w (RSTP), 802.1s (MSTP), 802.1X (Authentication), 802.1ad (QinQ), 802.1AB (LLDP)

Switching Performance:
- Switching bandwidth: 5.2 Gbps
- Switching latency: 7 µs
- MAC address table: 8,192 entries
- Priority queues: 4
- VLANs supported: up to 4,096
- IGMP multicast groups: 1,024
- Store‑and‑forward architecture

Ports:
- 6 × 10/100Base‑T(X) RJ‑45 ports (Auto MDI/MDI‑X)
- 2 × 1000Base‑X fiber ports (Multi‑Mode SC)
- Wavelength: 850 nm
- Fiber type: 50/125 µm or 62.5/125 µm
- Typical distance: up to 550 m
- Optical power: Tx –4 to –9.5 dBm, Rx 0 to –18 dBm

LED Indicators:
- Power (PWR1/PWR2/PWR3): Green
- Ring Master (R.M.): Green (flashing when active)
- Ring Status: Green (normal) / blinking (fault)
- Fault Relay: Amber
- LAN Ports: Green (Link/Activity), Amber (Full Duplex)
- Fiber Ports: Green (Activity), Amber (Link)

Power Requirements:
- Inputs:
- PWR1/PWR2: 12–48 VDC via 7‑pin terminal block
- PWR3: 12–48 VDC via power jack *(not for hazardous locations)*
- Power Consumption: ~7 W typical
- Protection: Reverse polarity and overload protection

Mechanical & Environmental:
- Dimensions (W × D × H): 52 × 106 × 144 mm
- Weight: ~740 g
- Enclosure: IP‑30 aluminum housing
- Mounting: DIN‑rail or wall‑mount
- Operating Temperature: –40 °C to +70 °C
- Storage Temperature: –40 °C to +85 °C
- Humidity: 5 % – 95 %, non‑condensing

Electrical Ratings:
- Rated supply input: 12–48 VDC
- Max. surrounding air temperature: 70 °C




### 4. Functionality

Operation & Management:
The IES‑A3062GF‑MM‑SC is a fully managed Layer 2 switch supporting multiple management interfaces:
- Web Browser (HTTP/HTTPS) for intuitive configuration
- Telnet/CLI for command‑line control
- RS‑232 Console Port (RJ‑45 to DB‑9 cable, 9600 bps, 8N1)
- SNMP v1/v2c/v3 for network monitoring
- ORing Open‑Vision Utility for centralized configuration and topology visualization

Use Cases & Applications:
- Oil & Gas field automation
- Hazardous industrial zones (C1D2/ATEX Zone 2)
- Power substations and SCADA networks
- Transportation and rail signaling systems
- Factory automation and process control

Compatibility:
Interoperable with standard Ethernet devices, supporting IEEE protocols and third‑party SNMP management tools.




### 5. Components & Accessories

Included in Package:
- IES‑A3062GF‑MM‑SC switch unit
- DIN‑rail mounting kit
- Wall‑mount bracket kit
- 7‑pin terminal block connector
- RS‑232 console cable (RJ‑45 ↔ DB‑9 F)
- Dust covers for RJ‑45 ports
- Quick Installation Guide (QIG)
- Product CD (manuals and Open‑Vision utility)
- Mounting screws (M3 × 5 mm)

Optional Accessories:
- External DC power supply (12–48 VDC)
- Fiber patch cords (SC multi‑mode)
- DIN‑rail power adapters

Connectors:
- RJ‑45 for Ethernet ports
- SC connectors for fiber ports
- 7‑pin terminal block for dual DC inputs
- Power jack for auxiliary DC input
- RJ‑45 console port for serial management




### 6. Installation & Setup

Mounting Options:
- DIN‑Rail Installation:
1. Attach DIN‑rail clip to rear panel.
2. Hook upper edge onto DIN‑rail and press until it clicks.
- Wall Mounting:
1. Remove DIN‑rail clip.
2. Attach wall‑mount bracket using six screws.
3. Leave ~2 mm clearance for sliding into position.

Wiring Guidelines:
- Use separate routing for power and signal cables.
- Ground the device before connecting power.
- Use 28–12 AWG wires rated ≥ 104 °C.
- Ensure transient disturbances do not exceed 140 % of rated voltage.

Power Connection:
- Connect V+ and V– to terminal block inputs PWR1 and PWR2.
- Tighten wire clamps securely.
- Optional PWR3 via DC jack (non‑hazardous use only).

Network Connections:
- Ethernet: CAT 5e UTP cables up to 100 m.
- Fiber: Multi‑mode SC cables up to 550 m (TX ↔ RX cross‑connection).

Console Access:
- Connect PC via RS‑232 cable (DB‑9 F ↔ RJ‑45).
- Default settings: 9600 bps, 8 data bits, no parity, 1 stop bit.

Default Network Settings:
- IP Address: 192.168.10.1
- Subnet Mask: 255.255.255.0
- Gateway: 192.168.10.254
- Username/Password: admin/admin




### 7. Performance & Capabilities

Redundancy & Recovery:
- O‑Ring: < 10 ms recovery over 250 nodes
- Open‑Ring: interoperability with other vendors’ rings
- O‑Chain: multi‑ring redundancy topology
- Dual Homing: redundant uplinks to RSTP networks
- Coupling Ring: interconnects multiple O‑Rings

Traffic Management:
- QoS (802.1p/TOS/DSCP): 4 priority queues
- Rate Limiting: configurable ingress/egress limits
- Port Trunking: static or LACP (802.3ad) aggregation
- VLAN: 802.1Q tagging, QinQ, GVRP dynamic VLANs
- IGMP Snooping: multicast optimization

Security & Access Control:
- 802.1X authentication with RADIUS
- MAC filtering and port security
- IP security lists for management access
- SNMPv3 encrypted authentication
- Port lock to prevent unauthorized MAC access

Diagnostics & Monitoring:
- System logs, event notifications, port statistics, MAC tables, ping utility
- Syslog/SNMP/Email alerts for power or link events
- Fault relay output for external alarm integration

Limitations:
- Power jack not certified for hazardous use
- Fiber distance limited to 550 m (multi‑mode)




### 8. Standards & Compliance

Electrical & Safety:
- UL 508 (E331061)
- UL/cUL Class I Division 2 Groups A/B/C/D
- ATEX Class I Zone 2 (II 3G Ex nA IIC T4 Gc)
- IEC 60079‑0 Ed.6, IEC 60079‑15 Ed.4
- EN 60079‑0:2012, EN 60079‑15:2010

EMC & Environmental:
- FCC Part 15 Class A
- CISPR (EN 55022) Class A
- EN 61000‑4‑2 (ESD), ‑4‑3 (RS), ‑4‑4 (EFT), ‑4‑5 (Surge), ‑4‑6 (CS), ‑4‑8, ‑4‑11
- IEC 60068‑2‑6 (Vibration), ‑2‑27 (Shock), ‑2‑32 (Free Fall)

Ingress Protection: IP‑30 metal enclosure

Environmental Conditions:
- Pollution degree 2 (IEC 60664‑1)
- Must be installed in ATEX‑certified IP54 enclosure, accessible only by tool

Cable Requirements:
- Cable temperature rating ≥ 104 °C
- Terminal block: Dinkle 5EHDRC‑07P / 5ESDV‑07P, 300 V, 15 A, 105 °C




### 9. Additional Information

Warranty:
- 5‑year limited warranty covering defects in materials and workmanship.
- Excludes misuse, unauthorized modifications, or improper installation.

Support & Maintenance:
- Technical support via email: support@oring-networking.com
- Firmware upgrades available through web interface or TFTP.
- Configuration backup/restore via TFTP or Open‑Vision utility.

Firmware & Software Updates:
- Web‑based firmware upgrade or TFTP upload supported.
- Open‑Vision software provides centralized monitoring, topology mapping, and batch configuration.

Maintenance Recommendations:
- Periodically verify grounding and power connections.
- Keep ventilation unobstructed; avoid exposure to conductive dust.
- Use only certified enclosures in hazardous areas.




### Summary

The ORing IES‑A3062GF‑MM‑SC is a high‑performance, industrial‑grade managed Ethernet switch purpose‑built for Oil & Gas, energy, and process automation sectors. With C1D2/ATEX Zone 2 certification, triple redundant power inputs, and wide‑temperature operation, it ensures continuous network availability in hazardous and extreme environments. Its advanced O‑Ring redundancy, comprehensive Layer 2 management, and robust security make it ideal for mission‑critical applications requiring deterministic performance, reliability, and compliance with stringent industrial standards.

No accessories available.