IES-A3062GF-SS-SC

Oil&Gas Ind. Managed Switch 2*1000FX SS 6*100TX C1D2 ATEX
  • Manufacturer Oring
  • Category: Oil & Gas (C1D2 Approved)
  • The IES-A3062GF-SS-SC is a rugged, managed industrial Ethernet switch designed for Oil & Gas and other hazardous environments. It belongs to the IES-A3 Series, a family of high-performance managed switches certified for C1D2 and ATEX Class 1 Zone 2 applications. The model features 2×1000Base-X single-mode SC fiber ports and 6×10/100Base-T(X) copper ports, providing reliable, redundant, and secure networking in extreme industrial conditions.
- Industrial-Grade Design: Certified for C1D2 and ATEX Class 1 Zone 2, suitable for hazardous locations.
- High Reliability: Supports O-Ring redundancy with recovery time <10 ms over 250 nodes.
- Flexible Network Redundancy: Supports O-Ring, Open-Ring, O-Chain, STP/RSTP/MSTP, and MRP (IEC 62439-2).
- Advanced Management: Managed via Web GUI, Telnet, Console (CLI), SNMP v1/v2c/v3, and ORing Open-Vision centralized management software.
- Security: 802.1x port-based access control, MAC-based port security, IP security lists, SNMPv3 authentication, and RADIUS integration.
- Quality of Service (QoS): IEEE 802.1p priority queuing, TOS/DSCP, and weighted fair or strict priority scheduling.
- Multicast Optimization: IGMP v2/v3 snooping and multicast filtering for efficient bandwidth utilization.
- Time Synchronization: Supports SNTP and PTP (IEEE 1588) for precise clock synchronization.
- Event Notification: SYSLOG, SNMP traps, and SMTP email alerts for proactive monitoring.
- Wide Temperature Range: Operates from -40°C to +70°C, suitable for extreme environments.
- Triple Power Input: Redundant 12–48 VDC inputs (two terminal blocks + one power jack).
- Compact and Durable: IP-30 metal enclosure, DIN-rail and wall-mountable, vibration and shock resistant.
- Warranty: 5-year manufacturer warranty.

Country of origin: Taiwan R.O.C.

Customs tariff number: 8517 6200 900

Comprehensive Product Summary – ORing IES-A3062GF-SS-SC Industrial Managed Switch




### 1. Product Overview

Product Name: Industrial Managed Ethernet Switch
Model: IES-A3062GF-SS-SC
Series: IES-A3 Series
Article Number: IES-A3062GF-SS-SC
Manufacturer: ORing Industrial Networking Corp.
Manufacturer Website: [www.oring-networking.com](http://www.oring-networking.com)
Contact:
- Tel: +886-2-2218-1066
- Fax: +886-2-2218-1014
- Email: support@oring-networking.com
Headquarters: 3F, 542-2 Zhongzheng Road, Xindian District, New Taipei City 231, Taiwan

The IES-A3062GF-SS-SC is a rugged, managed industrial Ethernet switch designed for Oil & Gas and other hazardous environments. It belongs to the IES-A3 Series, a family of high-performance managed switches certified for C1D2 and ATEX Class 1 Zone 2 applications. The model features 2×1000Base-X single-mode SC fiber ports and 6×10/100Base-T(X) copper ports, providing reliable, redundant, and secure networking in extreme industrial conditions.




### 2. Key Features

- Industrial-Grade Design: Certified for C1D2 and ATEX Class 1 Zone 2, suitable for hazardous locations.
- High Reliability: Supports O-Ring redundancy with recovery time <10 ms over 250 nodes.
- Flexible Network Redundancy: Supports O-Ring, Open-Ring, O-Chain, STP/RSTP/MSTP, and MRP (IEC 62439-2).
- Advanced Management: Managed via Web GUI, Telnet, Console (CLI), SNMP v1/v2c/v3, and ORing Open-Vision centralized management software.
- Security: 802.1x port-based access control, MAC-based port security, IP security lists, SNMPv3 authentication, and RADIUS integration.
- Quality of Service (QoS): IEEE 802.1p priority queuing, TOS/DSCP, and weighted fair or strict priority scheduling.
- Multicast Optimization: IGMP v2/v3 snooping and multicast filtering for efficient bandwidth utilization.
- Time Synchronization: Supports SNTP and PTP (IEEE 1588) for precise clock synchronization.
- Event Notification: SYSLOG, SNMP traps, and SMTP email alerts for proactive monitoring.
- Wide Temperature Range: Operates from -40°C to +70°C, suitable for extreme environments.
- Triple Power Input: Redundant 12–48 VDC inputs (two terminal blocks + one power jack).
- Compact and Durable: IP-30 metal enclosure, DIN-rail and wall-mountable, vibration and shock resistant.
- Warranty: 5-year manufacturer warranty.




### 3. Technical Specifications

Ethernet Standards:
IEEE 802.3 (10Base-T), 802.3u (100Base-TX/FX), 802.3z (1000Base-LX/SX), 802.3ab (1000Base-T), 802.3ad (LACP), 802.3x (Flow Control), 802.1D (STP), 802.1p (CoS), 802.1Q (VLAN Tagging), 802.1w (RSTP), 802.1s (MSTP), 802.1x (Authentication), 802.1ad (QinQ), 802.1AB (LLDP).

Ports:
- 6 × 10/100Base-T(X) RJ-45 ports (Auto MDI/MDI-X)
- 2 × 1000Base-X single-mode SC fiber ports

Fiber Optics:
- Type: Single-mode SC
- Wavelength: 1310 nm
- Distance: Up to 10 km
- Optical Power:
- Max Output: -3 dBm
- Min Output: -9.5 dBm
- Sensitivity: 0 dBm
- Saturation: -20 dBm

Performance:
- Switching Bandwidth: 5.2 Gbps
- Switching Latency: 7 µs
- MAC Address Table: 8192 entries
- VLANs Supported: 4096
- IGMP Multicast Groups: 1024
- Priority Queues: 4
- Processing Type: Store-and-Forward

Power Requirements:
- Input Voltage: 12–48 VDC (PWR1/2 via terminal block, PWR3 via power jack)
- Power Consumption: 7 W typical
- Reverse Polarity Protection: Yes
- Overload Current Protection: Yes
- Note: Power jack not for use in hazardous locations.

Environmental:
- Operating Temperature: -40°C to +70°C
- Storage Temperature: -40°C to +85°C
- Humidity: 5–95% non-condensing
- Max Ambient Air Temperature: 70°C

Mechanical:
- Dimensions (W×D×H): 52 × 106 × 144 mm
- Weight: ~740 g
- Enclosure: IP-30 rated metal housing
- Mounting: DIN-rail and wall-mount options

LED Indicators:
- Power (PWR1, PWR2, PWR3): Green
- Ring Master (R.M): Green
- Ring Status: Green (steady/blinking)
- Fault: Amber
- Port Link/Activity: Green
- Full Duplex: Amber




### 4. Functionality

Operation & Management:
The IES-A3062GF-SS-SC is a fully managed switch supporting multiple management interfaces:
- Web-based GUI (HTTP/HTTPS)
- Telnet and CLI (via RS-232 console or network)
- SNMP v1/v2c/v3 for integration with network management systems
- ORing Open-Vision software for centralized monitoring and configuration

Use Cases:
- Oil & Gas field automation
- Hazardous industrial zones (C1D2/ATEX)
- Power substations and energy distribution
- Transportation and rail systems
- Factory automation and SCADA networks

Compatibility:
Interoperable with standard Ethernet devices, supporting IEEE 802.3/802.1 protocols, Modbus/TCP, and SNMP-based monitoring tools.




### 5. Components & Accessories

Included Items:
- IES-A3062GF-SS-SC switch unit
- DIN-rail mounting kit
- Wall-mount kit
- 7-pin terminal block connector
- RS-232 console cable (RJ-45 to DB9-F)
- Dust covers for RJ-45 ports
- Quick Installation Guide (QIG)
- Product CD (manuals, Open-Vision utility)
- Mounting screws (M3×5)

Optional Accessories:
- External power supply (12–48 VDC)
- Fiber patch cords (SC single-mode)
- DIN-rail power adapters

Connectors:
- RJ-45 for Ethernet and console
- SC connectors for fiber ports
- 7-pin terminal block for redundant power inputs




### 6. Installation & Setup

Mounting Options:
- DIN-Rail Installation:
1. Attach DIN-rail kit to the rear panel.
2. Hook the top of the kit onto the DIN-rail.
3. Push until it clicks into place.
- Wall Mounting:
1. Remove DIN-rail kit.
2. Attach wall-mount brackets using provided screws.
3. Mount to wall, leaving 2 mm clearance for sliding fit.

Wiring Guidelines:
- Use separate routing for power and signal cables.
- Ground the device before connecting power.
- Use 28–12 AWG wires rated ≥104°C.
- Ensure transient protection ≤140% of rated voltage.

Power Connection:
- Connect V+ and V– to terminal block inputs (PWR1/PWR2).
- Optional PWR3 via DC jack (non-hazardous use only).
- Supports redundant power for uninterrupted operation.

Network Connection:
- RJ-45 ports: CAT5e or higher UTP cables (max 100 m).
- Fiber ports: Single-mode SC cables (up to 10 km).
- Console: RS-232 (115200, 8, N, 1) for CLI access.




### 7. Performance & Capabilities

Redundancy & Recovery:
- O-Ring: <10 ms recovery over 250 switches.
- Open-Ring: Interoperability with third-party ring systems.
- O-Chain: Multi-ring redundancy topology.
- Dual Homing: Backup uplink to RSTP networks.
- RSTP/MSTP/STP: IEEE 802.1D/w/s compliant redundancy.

Traffic Management:
- QoS: 4 priority queues, 802.1p, TOS/DSCP, port-based priority.
- VLAN: 802.1Q tagging, QinQ, GVRP, up to 4096 VLANs.
- Port Trunking: Static or LACP aggregation for bandwidth scaling.
- Rate Limiting: Configurable ingress/egress limits.

Security:
- 802.1x authentication with RADIUS
- MAC-based port security and blacklist
- IP-based access control
- SNMPv3 encryption and authentication

Diagnostics & Monitoring:
- System event logs, port statistics, MAC address table
- Ping utility for connectivity testing
- Syslog and email alerts for event reporting

Limitations:
- Power jack not certified for hazardous use
- Fiber distance limited to 10 km (single-mode)




### 8. Standards & Compliance

Electrical & Safety:
- UL508 (E331061)
- UL/cUL Class I Division 2, Groups A/B/C/D
- ATEX Class 1 Zone 2 (DEMKO 13 ATEX 1317577X)
- Ex nA IIC T4 Gc (-40°C ≤ Tamb ≤ +70°C)

EMC & Environmental:
- FCC Part 15, CISPR EN55022 Class A
- EN61000-4-2 (ESD), EN61000-4-3 (RS), EN61000-4-4 (EFT), EN61000-4-5 (Surge), EN61000-4-6 (CS), EN61000-4-8, EN61000-4-11
- IEC 60068-2-6 (Vibration), IEC 60068-2-27 (Shock), IEC 60068-2-32 (Free Fall)

ATEX Installation Conditions:
- Must be installed in IP54-rated enclosure
- Accessible only with tools
- Pollution degree ≤2 (IEC 60664-1)
- Cable temperature rating ≥104°C

Applicable Standards:
- IEC 60079-0 Ed.6
- IEC 60079-15 Ed.4
- EN 60079-0:2012
- EN 60079-15:2010




### 9. Additional Information

Warranty:
5 years limited warranty covering defects in materials and workmanship.
Excludes misuse, unauthorized modifications, or improper installation.

Support & Maintenance:
- Firmware upgrades via Web or TFTP
- Configuration backup/restore via TFTP
- Remote management through Open-Vision software
- Technical support via email or phone

Software Utilities:
- Open-Vision: Windows-based centralized management tool for configuration, monitoring, and topology visualization.
- CLI Commands: Full command set for VLAN, QoS, redundancy, SNMP, and security configuration.

Maintenance Recommendations:
- Periodically verify grounding and power connections.
- Keep ventilation unobstructed.
- Update firmware for security and performance improvements.
- Inspect fiber connectors for cleanliness and integrity.




### Summary

The ORing IES-A3062GF-SS-SC is a robust, feature-rich managed Ethernet switch engineered for mission-critical industrial networks in hazardous environments. With dual Gigabit single-mode fiber uplinks, six Fast Ethernet copper ports, and comprehensive redundancy and security features, it ensures continuous, secure, and high-performance communication. Its compliance with C1D2 and ATEX Zone 2 standards, wide temperature tolerance, and redundant power design make it ideal for Oil & Gas, energy, and heavy industrial applications requiring maximum uptime and safety.

No accessories available.